MaxLong SEW832 Serial To Ethernet Server User Manual

June 14, 2024
MaxLong

SEW832 Serial to Ethernet Server
User’s Manual MaxLong SEW832 Serial To Ethernet
ServerJerryPeng 0975-365-352
www.maxlong.com.tw

http://www.maxlong.com.tw/product-detail/lora-converter
http://www.maxlong.com.tw

Introduction

This SEW832 Ethernet+WiFi Serial Server provides the ways of connecting serial devices to both Ethernet and Wireless LAN (Wi-Fi 802.11 b/g/n ). It is designed to operate serial ports through Ethernet (10/100Mbps) and wireless (Wi-Fi 802.11 b/g/n) over TCP/IP network. As the data is transmitted via TCP/IP protocol, therefore data acquisition and controlling is available to go through Intranet and Internet.  There are two serial ports as one is a RS-232 and other one is RS-422/485.
Configuration is easy to operate via web page setup.
This WiFi Serial Server is a high performance design composed with carefully selecting qualified components from reliable and certified sources. This operation manual will guide you to configure functions step by step.
This WiFi Serial Server provides TCP Server Mode, TCP Client Mode, and UDP Mode for selection. It also supports manual configuration via web browser and support various protocols including HTTP, DHCP,  ICMP, and ARP. These are the best solution to coordinate your Serial interface devices.

1.1 Product Views

Antenna Side

MaxLong SEW832 Serial To Ethernet Server - Views

Serial Interface

MaxLong SEW832 Serial To Ethernet Server - Views 2

1.2 Wiring Architecture

MaxLong SEW832 Serial To Ethernet Server - Wiring

Configuration

2.1Configuration Via Web
Step1➔ The first thing is to configure the Host PC’s IP address IP :192.168.1.xx
Step2➔ Open a web page of configuration http://192.168.1.100
Step3➔ Default User name: “admin” and Password: “admin”

MaxLong SEW832 Serial To Ethernet Server - Figure 1

Step4➔And now you have successfully connected to this Modbus gateway

MaxLong SEW832 Serial To Ethernet Server - Figure 2

2.2 Configuration Sections
There are 4 pages as per “System”, “Network”, “Serial” and “Over TCP/IP”. MaxLong SEW832 Serial To Ethernet Server - Figure 3

2.2.1 System Setup

  1. System: Where one can change Password, set up Auto Reset time and modify Device Name, Description of device etc.

  2. Appearance of Wireless and Ethernet setup:
    MaxLong SEW832 Serial To Ethernet Server - Figure 5

  3. NTP: Enable / Disable NTP function; Set up NTP server and Time Zone.

  4. Firmware update:
    (1) If necessary, click “Browse” to open file manager
    MaxLong SEW832 Serial To Ethernet Server - Figure 7 (2) Select the file with specified version and click “Confirm” button.
    (3) When the selected file name appears on the input column, click “Update” button.

  5. Up to now, Setup is successfully configured. Please click “Save” this page before “Save and Reboot” for permanent web pages.
    Save| Save and Reboot
    ---|---

2.2.2 Network Setup

MaxLong SEW832 Serial To Ethernet Server - Figure 9

  1. Wireless section:
    (1) Type: to select “INFRASTRUCTURE” or “ACCESS POINT”
    MaxLong SEW832 Serial To Ethernet Server - Figure 10(2) When selected “INFRASTRUCTURE”, go to SSID, click “Scan” wget list of available SSID, select one to link.
    MaxLong SEW832 Serial To Ethernet Server - Figure 11(3) Input password for the AP and assign STATIC IP address
    MaxLong SEW832 Serial To Ethernet Server - Figure 12(4) In NB/PC, choose same SSID to link. NB/PC must close Ethernet in advance
    MaxLong SEW832 Serial To Ethernet Server - Figure 13

  2. When selected “ACCESS POINT”, Converter acts as an Access Point which is allowed to be connected by PC /NB /Smart Phone/ PAD. It supports DHCP server function. Soft AP broadcasts its SSID “CVIoT_XX_XX_XX_XX_XX_XX”. PC /NB /Smart Phone/PAD should connect to this SSID and then open web browser with default IP for Converter setup.
    MaxLong SEW832 Serial To Ethernet Server - Figure 14

  3. Password: Key in selected AP log in password
    MaxLong SEW832 Serial To Ethernet Server - Figure 15

  4. Encrypt
    MaxLong SEW832 Serial To Ethernet Server - Figure 16

  5. Mode: IP Address
    (1) “DHCP”: Let AP to assign IP address to itself
    MaxLong SEW832 Serial To Ethernet Server - Figure 17(2) “STATIC”: To input assigned IP address, Subnet Mask.
    MaxLong SEW832 Serial To Ethernet Server - Figure 18

  6. Ethernet: select STATIC or DHCP to assign IP address.
    MaxLong SEW832 Serial To Ethernet Server - Figure 19

  7. Gateway and DNS: To check with MIS for right IP address.
    ※The Gateway must be set with correct IP enable to connect with Internet.

  8. Up to now, Setup is successfully configured. Please click “Save” this page before permanent change of configuration.

2.2.3 Serial Port Setup
Input each parameters to match with the remote terminal units.

  1. Baud Rate

  2. Parity

  3. Data Bits

  4. Stop Bits

  5. Flow Control

  6. RxDelay(ms)

  7. TxDelay(ms)
    MaxLong SEW832 Serial To Ethernet Server - Figure 22

  8. Click “Save” this page before permanent pages

2.2.4 Serial Port Overt TCP/IP Setup
There are TCP modes for selection: TCP Server / TCP Client / UDP

MaxLong SEW832 Serial To Ethernet Server - Figure 24

  1. Configure as TCP Server
    Configure TCP server port number and message time out period. At this mode, this device will wait for client connection.
    MaxLong SEW832 Serial To Ethernet Server - Figure 25

  2. Configure as TCP Client
    Allow to configure 4 remote destination host IP address, port number.
    At TCP client mode, Serial Server establishes a connection with remote host and sending data to remote host actively.
    MaxLong SEW832 Serial To Ethernet Server - Figure 26

  3. Configure as UDP
    Picture as above TCP client mode. Allow to configure 4 remote destination host IP address, port number. At UDP mode, this Device establishes a connection with remote host and sending data to remote host  actively.

2.2.5 Reset Button
If any chance you forgot the login password or have incorrect settings making this Device inoperable, upon the power is on and the “SYS” LED light on, use a point tip to press this button and hold it for more than 20  seconds the release the point tip. The Device will reboot and all the parameters will be reset to the factory default.