Introduction
This SEW832 Ethernet+WiFi Serial Server provides the ways of connecting serial
devices to both Ethernet and Wireless LAN (Wi-Fi 802.11 b/g/n ). It is
designed to operate serial ports through Ethernet (10/100Mbps) and wireless
(Wi-Fi 802.11 b/g/n) over TCP/IP network. As the data is transmitted via
TCP/IP protocol, therefore data acquisition and controlling is available to go
through Intranet and Internet. There are two serial ports as one is a RS-232
and other one is RS-422/485.
Configuration is easy to operate via web page setup.
This WiFi Serial Server is a high performance design composed with carefully
selecting qualified components from reliable and certified sources. This
operation manual will guide you to configure functions step by step.
This WiFi Serial Server provides TCP Server Mode, TCP Client Mode, and UDP
Mode for selection. It also supports manual configuration via web browser and
support various protocols including HTTP, DHCP, ICMP, and ARP. These are the
best solution to coordinate your Serial interface devices.
1.1 Product Views
Antenna Side
Serial Interface
1.2 Wiring Architecture
Configuration
2.1Configuration Via Web
Step1➔ The first thing is to configure the Host PC’s IP address IP
:192.168.1.xx
Step2➔ Open a web page of configuration http://192.168.1.100
Step3➔ Default User name: “admin” and Password: “admin”
Step4➔And now you have successfully connected to this Modbus gateway
2.2 Configuration Sections
There are 4 pages as per “System”, “Network”, “Serial” and “Over TCP/IP”.
2.2.1 System Setup
-
System: Where one can change Password, set up Auto Reset time and modify Device Name, Description of device etc.
-
Appearance of Wireless and Ethernet setup:
-
NTP: Enable / Disable NTP function; Set up NTP server and Time Zone.
-
Firmware update:
(1) If necessary, click “Browse” to open file manager
(2) Select the file with specified version and click “Confirm” button.
(3) When the selected file name appears on the input column, click “Update” button. -
Up to now, Setup is successfully configured. Please click “Save” this page before “Save and Reboot” for permanent web pages.
Save| Save and Reboot
---|---
2.2.2 Network Setup
-
Wireless section:
(1) Type: to select “INFRASTRUCTURE” or “ACCESS POINT”
(2) When selected “INFRASTRUCTURE”, go to SSID, click “Scan” wget list of available SSID, select one to link.
(3) Input password for the AP and assign STATIC IP address
(4) In NB/PC, choose same SSID to link. NB/PC must close Ethernet in advance
-
When selected “ACCESS POINT”, Converter acts as an Access Point which is allowed to be connected by PC /NB /Smart Phone/ PAD. It supports DHCP server function. Soft AP broadcasts its SSID “CVIoT_XX_XX_XX_XX_XX_XX”. PC /NB /Smart Phone/PAD should connect to this SSID and then open web browser with default IP for Converter setup.
-
Password: Key in selected AP log in password
-
Encrypt
-
Mode: IP Address
(1) “DHCP”: Let AP to assign IP address to itself
(2) “STATIC”: To input assigned IP address, Subnet Mask.
-
Ethernet: select STATIC or DHCP to assign IP address.
-
Gateway and DNS: To check with MIS for right IP address.
※The Gateway must be set with correct IP enable to connect with Internet. -
Up to now, Setup is successfully configured. Please click “Save” this page before permanent change of configuration.
2.2.3 Serial Port Setup
Input each parameters to match with the remote terminal units.
-
Baud Rate
-
Parity
-
Data Bits
-
Stop Bits
-
Flow Control
-
RxDelay(ms)
-
TxDelay(ms)
-
Click “Save” this page before permanent pages
2.2.4 Serial Port Overt TCP/IP Setup
There are TCP modes for selection: TCP Server / TCP Client / UDP
-
Configure as TCP Server
Configure TCP server port number and message time out period. At this mode, this device will wait for client connection.
-
Configure as TCP Client
Allow to configure 4 remote destination host IP address, port number.
At TCP client mode, Serial Server establishes a connection with remote host and sending data to remote host actively.
-
Configure as UDP
Picture as above TCP client mode. Allow to configure 4 remote destination host IP address, port number. At UDP mode, this Device establishes a connection with remote host and sending data to remote host actively.
2.2.5 Reset Button
If any chance you forgot the login password or have incorrect settings making
this Device inoperable, upon the power is on and the “SYS” LED light on, use a
point tip to press this button and hold it for more than 20 seconds the
release the point tip. The Device will reboot and all the parameters will be
reset to the factory default.