MaxLong Technology SLC485-S Lora Converter Instruction Manual

June 14, 2024
MaxLong Technology

MaxLong Technology SLC485-S Lora Converter

Product Information

Specifications

  • Communication technology: LoRa 862~932 MHz pass through mode or Modbus (non-LoRa WAN protocol)
  • Transmission mode: Multi-end points form a broadcast network according to the frequency band, and only one end point can send signals at a time (similar to the traditional Walkie-talkie design), only suitable for one Master+n Slaves applications.
  • Communication Flow: Maximum load 255 bytes per packet data.
  • Converter conversion Interface: RS232/485.
  • Measured communication distance: height 100cm measured 2 km at both ends, transmission success rate is about 90%.

Main Chip

LoRa

Serial Port

RS232/485:

  • Half Duplex of RS232 Baud Rate to 9600-19200bps
  • Half Duplex of RS485 Baud Rate to 9600-19200bps

Configurations and Management

Firmware: Com port support system firmware upgrade

Power Source

  • Supply Voltage: +5~24VDC Terminal Block +5V Micro USB (alternative)

Power Consumption

  • Standby:
    • 5V, 16.63mA
    • 12V, 6.97mA
    • 24V, 4.03mA
  • Transmission:
    • 5V, 17.35mA
    • 12V, 41.95mA
    • 24V, 21.73mA

Environment

Operating Temperature: 0~50°C

Product Usage Instructions

Installation

  1. Choose a suitable location for the SLC485-S converter.
  2. Ensure that the power supply is within the specified voltage range (+5~24VDC).
  3. Connect the RS232/RS485 devices to the appropriate interfaces on the converter.
  4. If using the Micro USB power source, connect the Micro USB cable to the converter.
  5. Securely mount the SLC485-S converter in its designated location.

Configuration

  1. Ensure that the power supply is connected and turned on.
  2. Access the SLC485-S configuration interface through a web browser on a connected device.
  3. Follow the on-screen instructions to configure the desired settings, such as communication mode and baud rate.
  4. Save the configuration changes and restart the converter if prompted.

Operation

The SLC485-S converter operates automatically once it is installed and configured.

Maintenance

To maintain the SLC485-S converter, follow these steps:

  1. Regularly inspect the converter for any physical damage or loose connections.
  2. Clean the converter using a soft, dry cloth to remove any dust or debris.
  3. If any issues arise, refer to the user manual for troubleshooting steps or contact technical support for assistance.

Antenna

The SLC485-S converter is available in both indoor and outdoor models. Complete indoor and outdoor antennas are provided with the converter.

Communication Flow

The SLC485-S converter supports a maximum load of 255 bytes per packet data. It converts the communication interface from RS232 to RS485 or vice versa.

Communication Technology

The SLC485-S converter supports LoRa 862~932 MHz pass-through mode or Modbus (non-LoRa WAN protocol) communication technology.

FAQ

Q: What is the maximum communication distance of the SLC485-S converter?

A: The SLC485-S converter can achieve a communication distance of up to 2 km at both ends when the height is 100cm. However, the transmission success rate is approximately 90%.

Q: Can the SLC485-S converter be used for multiple endpoints?

A: Yes, the SLC485-S converter can form a broadcast network with multiple endpoints. However, only one endpoint can send signals at a time, making it suitable for one Master+n Slaves applications.

Provide customized hardware and software services
The Best choice for loT city

SLC485-S

  • Plug and play
  • Easy to set up
  • Provides RS232/485 flexible use
  • Broadcast mode pairing not required
  • Simple construction maintenance and operation
  • Instant return (NO waiting time)
  • Indoor/Outdoor models are complete
  • Complete indoor and outdoor antenna available

Communication technology : LoRa 862~932 MHz pass through mode or Modbus. (non-LoRa WAN protocol)
Transmission mode : Multi-end points form a broadcast network according to the frequency band, and only one end point can send signals at a time (similar to the traditional Walkie-talkie design),only suitable for one Master+n Slaves applications.
Communication Flow : Maximum load 255 bytes per packet data.
Converter conversion Interface : RS232/485.
Measured communication distance: height 100cm measured 2 km at both ends, transmission success rate is about 90%

Industrial IoT LoRa Converter SLC485-S Specifications

  • Main Chip

    • LoRa Transmission : Semtech SX1276 Soc : Cortex® -M0
    • Memory: Flash 128K
  • LoRa

    • Frequency: 862~932MHz
    • Frequency Accuracy: ±10KHz Modulation: LoRa
    • Transmit Power: 2~+20dBm
    • Data Rate: 0.244~18.2Kbps(LoRa) High Sensitivity: down to -137dBm Communication Distance: 2~5Km Antenna Impedance: 50ohm
  • Serial Port
    RS232/485:

    • Half Duplex of RS232
      Baud Rate to 9600、19200bps

    • Half Duplex of RS485
      Baud Rate to 9600、19200bps

  • Configurations and Management

    • Firmware: Com port support system firmware upgrade
  • Power Source
    Supply Voltage: +5~24VDC Terminal Block +5V Micro USB (alternative)

  • Power Consumption

    • Standby: 5V,16.63mA 12V, 6.97mA 24V, 4.03mA
    • Transmission: 5V,17.35mA
      12V,41.95mA 24V,21.73mA
  • Environment
    Operating Temperature: 0℃~50℃

  • Mechanism

Dimensions

MaxLong-Technology-SLC485-S-Lora-Converter-FIG-1

Interface

MaxLong-Technology-SLC485-S-Lora-Converter-FIG-2

www.maxlong.com.tw