DYNATRAP DT1260SR Mosquito and Flying Insect Trap with Pole Mount Owner’s Manual

June 14, 2024
DynaTrap

DYNATRAP DT1260SR Mosquito and Flying Insect Trap with Pole Mount

DYNATRAP-DT1260SR-Mosquito-and-Flying-Insect-Trap-with-Pole-Mount-
product

Product Information

Specifications:

  • Model: DT1260
  • Product Name: Flying Insect Trap
  • Patents: Covered by one or more U.S. patents or pending patent applications
  • Website: www.DynaTrap.com/patents

Description:

The DT1260 Flying Insect Trap is a device designed to attract and trap flying insects using UV light and CO2 generated by the photo-catalysis between UV lamps and a special TiO2 coating. The insects are pulled into the screened base by a fan and trapped until they dehydrate and die. The trapped insects can be periodically emptied into the trash by removing the base.

Features:

  • UV light and CO2 attract flying insects
  • The fan pulls insects into the screened base
  • Special TiO2 coating enhances insect attraction
  • Retaining the cage allows monitoring of trapped insects
  • Easy cleaning and maintenance
  • Replaceable light bulb for optimal UV effectiveness

Product Usage Instructions

Installation:

  1. Unpack the unit and save the carton for off-season storage if needed.
  2. Assemble the stand by pulling the cord tight through the pole stand. Turn the base on its side and provide for more efficient operation.

Cleaning:

Regular cleaning of the unit is recommended to maintain its effectiveness. Follow the steps below for weekly and major cleaning:

Weekly Cleaning:

  1. Hold the switch on the revolving rotation door and turn it to the POWER OFF position. Unplug the unit.
  2. Twist the cage clockwise to remove any buildup from the inside of the retaining cage and fan using the included cleaning brush.

Major Cleaning:

  1. Remove the screw securing the fan housing to the light housing (A), and gently twist to separate. Do not disconnect wires.
  2. Use the cleaning brush to remove dirt and debris from the fan housing.
  3. Tuck the wires into the channel of the fan housing (D).
  4. Align the screw holes and place the light housing on top of the fan housing. Secure with a click and tighten the screw to the base of the light housing.

Replacing the Light Bulb:

The light bulb should be replaced regularly to ensure optimal UV effectiveness. Follow the steps below:

  1. Hold the switch on the revolving rotation door and turn it to the POWER OFF position. Unplug the unit and allow the bulb to cool before replacing.
  2. Remove the screw securing the fan housing to the light housing0 (A), and gently twist to separate. Do not disconnect wires.
  3. Loosen the screw securing the metal bracket securing the light bulb (B) and remove the metal bracket.
  4. Cover the bulb with a cloth to protect your fingers and hand. Grasp the bulb (with your hand and fingers protected by the cloth) and gently pull it from the socket (C).
  5. Remove any debris from the lamp socket with the cleaning brush.
  6. Insert the new bulb and reposition the metal bracket over the base of the bulb. Tighten the screw.
  7. Tuck the wires into the channel of the light housing (D).
  8. Align the screw holes and place the light housing on top of the fan housing. Secure with a click and tighten the screw to the base of the light housing.

FAQ (Frequently Asked Questions)

  • Q: How often should I clean the unit?
    A: It is recommended to clean the unit once per week to maintain its effectiveness.

  • Q: How often should I replace the light bulb?
    A: The light bulb should be replaced regularly, approximately every 4 months or after approximately 3,000 hours of use, to ensure optimal UV effectiveness.

  • Q: Can I press or push against the screen windows?
    A: No, do not press or push against the screen windows as it may damage the unit.

Thank you for purchasing the DYNATRAP® flying insect trap!
This product may be covered by one or more U.S. patents or pending patent applications. See www.DynaTrap.com/patents

IMPORTANT, RETAIN  FOR FUTURE REFERENCE:  READ CAREFULLY

WARNING: When using electric appliances, basic precautions should always be followed, including the following:

  • To disconnect, turn all controls to the off (“O”) position, then remove plug from outlet.
  • Unplug from outlet when not in use and before servicing or cleaning.
  • To reduce the risk of electrical shock, do not put the appliance in water or other liquid.
  • This appliance is provided with double insulation. Use only identical replacement parts.

IMPORTANT SAFETY INSTRUCTIONS

Please read these instructions before using the DynaTrap® Insect trap and keep for future reference.

  1. Always turn unit off and disconnect plug before servicing or cleaning.
  2. Do not position the unit near heat, gas, oil or other flammable materials.
  3. Mount out of reach from children.
  4. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or if it has been dropped into water.
  5. The electrical adapter provided with this product is equipped with a 2-conductor cord and a 2-prong plug as a  safety feature. If the plug does not fully fit in the outlet, contact a qualified electrician. To reduce the risk of electrical shock, only plug into a properly installed outlet. Do not attempt to defeat this safety feature.
  6. Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
  7. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
  8. Do not clean this product with water spray. Do not place where it can fall into water, or near flammable materials.
  9. Do not touch fan while in motion.
  10. Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from the receptacle. Keep cord away from sharp edges.
  11. If using outdoors, use only extension cords with a tag stating “Suitable for Use with Outdoor Appliances.”
  12. Use only extension cords that have plug and receptacles that match the product plug. Replace or repair damaged cords.
  13. Only use attachments recommended or sold by the manufacturer.
  14. SERVICING OF DOUBLE-INSULATED APPLIANCES – In a double-insulated appliance, two systems of insulation are provided instead of grounding. No grounding means is provided on a double insulated appliance, nor should a means for grounding be added to the appliance. Servicing of a double-insulated appliance requires extreme care and knowledge of the system, and should be done only by qualified service personnel. Replacement parts for a double-insulated appliance must be identical to those parts in the appliance. A double-insulated appliance is marked with the words “DOUBLE INSULATION”, “DOUBLE INSULATED” or the symbol .

INSTALLATION & OPERATING INSTRUCTIONS

  1. Unpack unit. Save cartons for off-season storage (if needed).
  2. Assemble Stand: Pull the cord tight through the pole stand. Turn base on its side and insert bottom threaded plastic piece into base, connecting to the threaded plastic cap. Twist threaded plastic cap clockwise to tighten.
  3. Complete installation by aligning the upper and lower support tube and inserting the bar sections. For more detailed instructions, please refer to assembly guide.
  4. Hold the Power switch on the side of the revolving rotation door. Twist the unit to the “POWER ON” position. When you hear a “click,” the machine is turned on.
  5. For best catch results leave unit on at all times, except when cleaning or servicing.
  6. Catch rate activity will be higher at night. For best catch results it is recommended  to keep the unit away from competing light sources.
  7. It is recommended to place the unit at least 20 to 40 feet away from where people will be sitting.
  8. This unit is all-weather resistant – designed for outdoor use including rainy conditions. Intended for household and commercial, indoor and outdoor use.
  9. To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.

CLEANING

Frequent cleaning will prolong the life of the unit, ensure fire prevention and provide for more efficient operation.

  1. Be sure to clean the unit once per week.
  2. To clean, hold the switch on the revolving rotation door and turn it to the “POWER OFF” position. After hearing the “click,” the machine is turned off. Unplug the unit.
  3. For weekly cleaning, twist the cage clockwise and remove any  buildup from the inside of the retaining cage and fan with the included cleaning brush.
  4. For major cleaning, remove the screw securing the fan housing to the light housing (A), and gently twist to separate. Do not disconnect wires. Using the cleaning brush, remove dirt and debris from the fan housing. Once the cleaning process has been completed, tuck the wires into the channel of the fan housing (D). Align the screw holes and place the light housing on top of fan housing. Secure with a click and tighten the screw to the base of the light housing.
    IMPORTANT : When replacing the retaining cage.
    DO NOT press/push against the screen windows.

REPLACING BULB

Replace with DynaTrap® bulb #41050 (or equivalent G24 Type – 56V/7W bulb)

The lightbulb life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced regularly to ensure optimal UV effectiveness. Even though the bulb’s light may be visible to you, its ability to attract mosquitoes diminishes over time.

  1. Hold the switch on the revolving rotation door and turn it to the “POWER OFF” position. UNPLUG UNIT, and allow bulb to cool before replacing.
  2. Remove the screw securing the fan housing to the light housing (A), and gently twist to separate carefully, do not disconnect wires. Loosen the screw securing the metal bracket securing the light bulb (B) and remove the metal bracket. Cover the bulb with a cloth to protect your fingers and hand. Grasp the bulb (with your hand and fingers protected by the  cloth) and gently pull the bulb from the socket (C).
  3. Remove any debris from the lamp socket with cleaning brush. Insert new bulb. Reposition the metal bracket over the base of the bulb and tighten the screw. Make sure to tuck the wires into the channel of the light housing so the wires do not get pinched or cut by the fan (D). Align the screw holes and place the light housing on top of fan housing. Secure with a “click” and tighten the screw to the base of the light housing.

HOW THE DYNATRAP® INSECT TRAP WORKS

Flying insects are attracted to the unit by the UV light and CO2 that is generated by the photo-catalysis between the UV lamps and the special TiO2 coating. The fan then pulls the insects into the screened base, trapping them until they dehydrate and die. The base can be removed, allowing the  contents to be periodically emptied into the trash. Monitor the insects trapped in the retaining cage, through the see-through screen, and empty when compartment becomes full.

TROUBLESHOOTING

DYNATRAP-DT1260SR-Mosquito-and-Flying-Insect-Trap-with-
Pole-Mount-fig- \(5\)

LIMITED WARRANTY

DYNAMIC guarantees to the original purchaser that this product is free from defective materials and workmanship. This warranty is limited to remedy any defective part for a period of one year from date of original date of purchase. Retain your original receipt as proof of purchase. This warranty does not apply to the light bulb, nor to, in our judgment, misuse or abuse. If this unit has been altered, no warranty is in force. This warranty does not apply if this unit is purchased outside the United States, excluding Canada and Mexico. In no case shall DYNAMIC be liable for any accidental, punitive, consequential, or any other damages of any kind for breach of this or any other warranty, expressed or implied, whatsoever. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

REPLACEMENT PARTS
41050 7-Watt Replacement UV Fluorescent Bulb (1 piece)
To see all replacement and accessory parts available for your DynaTrap, including UV-bulbs, fans, retaining cages, and more, visit www.DynaTrap.com.

SAVE THESE INSTRUCTIONS
FOR HOUSEHOLD AND COMMERCIAL, INDOOR AND OUTDOOR USE

Dynamic Solutions Worldwide, LLC 12247 W. Fairview Ave. Milwaukee, WI 53226 1-877-403-TRAP (8727)
[email protected]
www.DynaTrap.com
This device complies with Performance Standards for Light-Emitting Products, 21 DFR, Part 1040, Chapter 1, Subchapter J, Radiological health.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

DynaTrap User Manuals

Related Manuals