SEALEVEL SeaPORT+2 DB9 Serial Interface Adapter User Manual
- June 4, 2024
- SEALEVEL
Table of Contents
- Introduction
- Before You Get Started
- Installation Instructions
- Configuration
- Technical Description
- Specifications
- Appendix A – Troubleshooting
- Appendix B – How To Get Assistance
- Appendix C – Electrical Interface
- Appendix D – Asynchronous Communications
- Appendix E – Compliance Notices
- Caution
- Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SEALEVEL SeaPORT+2 DB9 Serial Interface Adapter
Introduction
The Sealevel Systems SeaPORT+2 equips the PC with 2 USB to RS-232/422/485 Asynchronous serial ports providing a versatile interface for common serial needs. The advantage of this product over more traditional approaches is that it does not require opening the computer case, nor does it require resources such as I/O ports or IRQ’s. It does require a system that supports USB both in terms of hardware and operating system.
Before You Get Started
What’s Included
The SeaPORT+2 is shipped with the following items. If any of these items is missing or damaged, contact the supplier.
- SeaPORT+2 USB to RS-232/422/485 Serial I/O Adapter
- USB Cable Part Number CA179 for Connecting to Upstream Host/Hub
Advisory Conventions
| Warning
The highest level of importance used to stress a condition where damage could
result to the product or the user could suffer serious injury
---|---
| Important
The middle level of importance used to highlight information that might not
seem obvious or a situation that could cause the product to fail.
| Note
The lowest level of importance used to provide background information,
additional tips, or other non-critical facts that will not affect the use of
the product.
Installation Instructions
Windows 98/ME/2000/XP/Vista™ Operating Systems
| Do not connect the device to a USB port until the software is installed.
---|---
- Begin by locating, selecting and installing the correct software from the Sealevel software driver database.
- Select the Part Number for your device from the listing.
- The setup file will automatically detect the operating environment and install the proper components. Follow the information presented on the installation screens that follow.
- A screen may appear with the declaration: “The publisher cannot be determined due to the problems below: Authenticode signature not found.” Please select the ‘Yes’ button and proceed with the installation. This declaration simply means that the Operating System is not aware of the driver being loaded. It will not cause any harm to your system.
- During setup, you may specify installation directories and other preferred configurations. This program also adds entries to the system registry that are necessary for specifying the operating parameters for each driver. An uninstall option is included to remove the driver and all registry/INI file entries from your system.
- Proceed with the physical installation of your SeaLINK USB serial adapter.
| Windows NT is not USB aware and thus cannot support this device.
---|---
Physical Installation
The screen captures below are taken from a Windows 98 installation. Your particular operating system may differ slightly from what is shown based on your version of Windows.
The SeaPORT+2 can be connected to any upstream type “A” port either at the PC host or an upstream hub. The SeaPORT+2 is hot pluggable, meaning there is no need to power down your computer prior to installation.
Connect the SeaPORT+2 to an upstream host or hub.
The New Hardware Found wizard will now proceed to locate the appropriate drivers. These drivers were installed during the SeaCOM software setup procedure. Once the drivers are found a new window will pop up indicating the installation of each of the four new ports.
If you view the system’s Device Manager, you should have new “COM” ports in
the Ports (COM & LPT) Device Class.
You can access your new COM: ports by using the assigned COM: identifiers as
shown above. In this case, it is COM 3 and 4. However, this assignment will
vary from system to system. At this point, the hardware is recognized and
ready to use.
Configuration
Original Configuration
This device ships from Sealevel Systems with the following configuration.
422 mode,
120 ohm termination,
1K ohm pull up on RX+
1K ohm pull down on RX
In order to change this configuration, the box must be opened. Do this by removing the four screws located on the bottom. When reassembling please note that the top and bottom are keyed to fit in only one direction.
Electrical Interface Selection
Each of the two ports on the SeaPORT+2 can be individually configured as an RS-232, RS-422, or RS-485 interface. This is selectable via the DIP switches and DIP shunts. Each of the switch positions is described on the following page
Switch Descriptions
**L**
| 485 option, OFF for 422.
OFF: No effect
ON : Connects TX+ to RX+ for two-wire operation
---|---
**L**
| 485 option, OFF for 422.
OFF: No effect
ON : Connects TX- to RX- for two-wire operation
**PU**
| 485 option, OFF for 422.
OFF: No effect
ON : Adds a 1 K ohm pull-up resistor to RX+
**PD**
| 485 option,
OFF for 422. OFF: No effect
ON : Adds a 1 K ohm pull-down resistor to RX
**T**
| 422 and 485 option.
OFF: No effect
ON : Adds a 120 ohm termination resistor between RX+ and RX-
Switch Examples
**485**
| Mode Selection
OFF : 422 Mode
The transmitter lines TX+ and TX- are always driven.
ON : 485 Mode
The transmitter lines TX+ and TX- are switched to high impedance when the
device is not actively transmitting data
---|---
**NE**
| 485 option, OFF for 422
OFF : The receiver is always enabled. In a two-wire setup the receiver will
echo back all transmitted data.
ON : The receiver is disabled when the transmitter is enabled. In a two-wire
setup the receiver will not echo back transmitted data.
| Switch positions 1 and 2 are for port 1 and switch positions 3 and 4 for
port 2
---|---
Switch Examples Continued
**Port:**
| RS-232 The corresponding shunt is in the 232 position. The switches will
have no effect.
---|---
**Port 2:**
| RS-485 two wire communication with no echo. The corresponding shunt is in the 422/485 position. Switches 485 2, NE 2, and Port 2 L, L, T, PU, and PD are all in the ON position.
Technical Description
The SeaPORT+2 utilizes two USB UARTs. These chips feature programmable baud rate, data format, 128 byte Dual Port TX Buffer, and 384 byte Dual Port RX Buffer. The RS-232/422/485 transceiver supports data rates up to 921.6K baud for RS-422/485 and up to 460.8K baud for RS 232.
Features
- Hot pluggable device that does not require opening the case
- No system resources are required (i.e. I/O ports or IRQ’s)
- LED status indicators for USB Enabled and port activity
Connector Pin Assignments
RS-422/485 (DB 9 Male)
Signal
| Name| Pin#| Mode
---|---|---|---
GND| Ground| 5|
TX+
| Transmit Data Positive| 4| Output
TX-| Transmit Data Negative| 3|
Output
RTS+
| Request To Send Positive| 6| Output
RTS-| Request To Send Negative| 7|
Output
RX+
| Receive Data Positive| 1| Input
RX-| Receive Data Negative| 2|
Input
CTS+
| Clear To Send Positive| 9| Input
CTS-| Clear To Send Negative| 8|
Input
RS-232 (DB-9 Male)
Signal
| Name| Pin#| Mode
---|---|---|---
GND| Ground| 5|
TX
| Transmit Data| 3| Output
RTS| Request To Send| 7|
Output
DTR
| Data Terminal Ready| 4| Output
RX| Receive Data| 2|
Input
CTS
| Clear To Send| 8| Input
DSR| Data Set Ready| 6|
Input
DCD
| Data Carrier Detect| 1| Input
RI| Ring Indicator| 9|
Input
Specifications
Environmental Specifications
Specification
| Operating| Storage
---|---|---
Temperature Range| 0º to 50º C (32º to 122º F)|
-20º to 70º C (-4º to 158º F)
Humidity Range
| 10 to 90% R.H. Non-Condensing|
10 to 90% R.H. Non-Condensing
Physical Dimensions
Package Length
|
7.06 inches (17.93 cm)
---|---
Package Width
| 5.32 inches (13.51 cm)
Package Height|
1.50 inches (3.81 cm)
Mean Time Between Failures (MTBF)
Greater than 150,000 hours. (Calculated)
Manufacturing
All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and
are 100% electrically tested.
These printed circuit boards are solder mask over bare copper or solder mask
over tin nickel.
Power Consumption
This device is a high-power USB device. It must be plugged into the USB root hub or a self-powered hub capable of supplying 500 mA per port.
Appendix A – Troubleshooting
Serial Utility test software is supplied with the Sealevel Systems adapter and will be used in the troubleshooting procedures. Using this software and following these simple steps, most common problems can be eliminated without the need to call Technical Support.
- If your adapter isn’t working, first check to make sure that USB support is enabled in the System BIOS and it is functioning properly in the operating system. This can be done by using either the Windows 98/ME or Windows 2000 Device Manager.
- Ensure that the Sealevel Systems software has been installed on the machine so that the necessary files are in place to complete the installation.
- When the SeaPORT+2 is configured properly, the USB Enabled LED (E) will be lit. This should allow you to use Sealevel’s WinSSD utility and the supplied loopback plug to check communications. The supplied loopback plug connects TD to RD. If you decide to test the Modem Control Signals, a full pin loopback plug will be required. Details on loopback plugs are included on WinSSD. Contact Sealevel Systems if you need further assistance.
- When testing the SeaPORT+2 in loopback mode, you should see the port LED’s flashing as well as seeing echoed data on the screen. The loopback test first transmits a HEX pattern, 55AA, and then a ASCII string of data. If this test passes, then the SeaPORT+2 is ready for use in your application.
- Please note that if the adapter is configured for 2 wire RS-485 with no echo a loopback test is not possible. The receiver in this case will be turned off and the test will fail. If you plan on using this device in two wire mode test the adapter in RS-422 mode first. Then configure the adapter for your application.
Appendix B – How To Get Assistance
Please refer to:
Appendix A – Troubleshooting prior to calling Technical Support.
-
Read this manual thoroughly before attempting to install the adapter in your system.
-
When calling for technical assistance, please have your user manual and current adapter settings.
If possible, please have the adapter connected in a computer ready to run diagnostics. -
Sealevel Systems maintains a home page on the Internet. Our home page address is www.sealevel.com. The latest software updates, and newest manuals are available via our FTP site that can be accessed from our home page.
-
Technical support is available Monday thru Friday from 8:00 a.m. to 5:00 p.m. Eastern time.
Technical support can be reached at 864-843-4343.
RETURN AUTHORIZATION MUST BE OBTAINED FROM SEALEVEL SYSTEMS BEFORE RETURNED MERCHANDISE WILL BE ACCEPTED. AUTHORIZATION CAN BE OBTAINED BY CALLING SEALEVEL SYSTEMS AND REQUESTING A RETURN MERCHANDISE AUTHORIZATION (RMA) NUMBER
Appendix C – Electrical Interface
RS-232
Quite possibly the most widely used communication standard is RS-232. This
implementation has been defined and revised several times and is often
referred to as RS-232 or EIA/TIA-232. The IBM PC computer defined the RS-232
port on a 9 pin D sub connector and subsequently the EIA/TIA approved this
implementation as the EIA/TIA-574 standard. This standard is defined as the
9-Position Non-Synchronous Interface between Data Terminal Equipment and Data
Circuit-Terminating Equipment Employing Serial Binary Data Interchange. Both
implementations are in wide spread use and will be referred to as RS-232 in
this document. RS-232 is capable of operating at data rates up to 20 Kbps
atdistances less than 50 ft.
The absolute maximum data rate may vary due to line conditions and cable
lengths. RS-232 is a single ended or unbalanced interface, meaning that a
single electrical signal is compared to a common signal (ground) to determine
binary logic states. The RS-232 and the EIA/TIA-574 specification define two
types of interface circuits, Data Terminal Equipment (DTE) and Data Circuit-
Terminating Equipment (DCE). The SeaPORT+2 is a DTE device.
RS-422
The RS-422 specification defines the electrical characteristics of balanced voltage digital interface circuits. RS-422 is a differential interface that defines voltage levels and driver/receiver electrical specifications. On a differential interface, logic levels are defined by the difference in voltage between a pair of outputs or inputs. In contrast, a single ended interface, for example RS-232, defines the logic levels as the difference in voltage between a single signal and a common ground connection. Differential interfaces are typically more immune to noise or voltage spikes that may occur on the communication lines. Differential interfaces also have greater drive capabilities that allow for longer cable lengths. RS422 is rated up to 10 Megabits per second and can have cabling 4000 feet long. RS-422 also defines driver and receiver electrical characteristics that will allow 1 driver and up to 32 receivers on the line at once. RS-422 signal levels range from 0 to +5 volts. RS-422 does not define a physical connector.
RS-485
RS-485 is backwardly compatible with RS-422; however, it is optimized for
partyline or multi-drop applications. The output of the RS-422/485 driver is
capable of being Active (enabled) or Tri-State (disabled). This capability
allows multiple ports to be connected in a multi-drop bus and selectively
polled.
RS-485 allows cable lengths up to 4000 feet and data rates up to 10 Megabits
per second. The signal levels for RS-485 are the same as those defined by
RS-422. RS-485 has electrical characteristics that allow for 32 drivers and 32
receivers to be connected to one line. This interface is ideal for multi-drop
or network environments. RS-485 tri-state driver (not dual-state) will allow
the electrical presence of the driver to be removed from the line. Only one
driver may be active at a time and the other driver(s) must be tri-stated.
RS-485 can be cabled in two ways, two wire and four wire mode. Two wire mode
does not allow for full duplex communication and requires that data be
transferred in only one direction at a time. For half-duplex operation, the
two transmit pins should be connected to the two receive pins (Tx+ to Rx+ and
Tx- to Rx-). Four wire mode allows full duplex data transfers. RS-485 does not
define a connector pin-out or a set of modem control signals. RS-485 does not
define a physical connector.
Appendix D – Asynchronous Communications
Serial data communications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character. Data rate, error checking, handshaking, and character framing (start/stop bits) are pre-defined and must correspond at both the transmitting and receiving ends.
Asynchronous communications is the standard means of serial data communication
for PC compatibles and PS/2 computers. The original PC was equipped with a
communication or COM: port that was designed around an 8250 Universal
Asynchronous Receiver Transmitter (UART). This device allows asynchronous
serial data to be transferred through a simple and straightforward programming
interface. Character boundaries for asynchronous communications are defined by
a starting bit followed by a predefined number of data bits (5, 6, 7, or 8).
The end of the character is defined by the transmission of a predefined number
of stop bits (usually 1, 1.5 or 2). An extra bit used for error detection is
often appended before the stop bits.
This special bit is called the parity bit. Parity is a simple method of determining if a data bit has been lost or corrupted during transmission. There are several methods for implementing a parity check to guard against data corruption. Common methods are called (E)ven Parity or (O)dd Parity. Sometimes parity is not used to detect errors on the data stream. This is referred to as (N)o parity. Because each bit in asynchronous communications is sent consecutively, it is easy to generalize asynchronous communications by stating that each character is wrapped (framed) by pre defined bits to mark the beginning and end of the serial transmission of the character. The data rate and communication parameters for asynchronous communications have to be the same at both the transmitting and receiving ends. The communication parameters are baud rate, parity, number of data bits per character, and stop bits (i.e. 9600,N,8,1).
Appendix E – Compliance Notices
Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the limits for Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
EMC Directive Statement
Products bearing the CE Label fulfill the requirements of the EMC directive (89/336/EEC) and of the low-voltage directive (73/23/EEC) issued by the European Commission. To obey these directives, the following European standards must be met:
- EN55022 Class B – “Limits and methods of measurement of radio interference characteristics of information technology equipment”
- EN55024 – “Information technology equipment Immunity characteristics Limits and methods of measurement”.
| Switch positions 1 and 2 are for port 1 and switch positions 3 and 4 for
port 2
---|---
Caution
Sealevel Systems, Inc. is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution of attachment of connecting cables and equipment other than those specified by Sealevel Systems. Such unauthorized modifications, substitutions, or attachments may void the user’s authority to operate the equipment. The correction of interference caused by such unauthorized modifications, substitutions, or attachments will be the responsibility of the user.
Always use cabling provided with this product if possible. If no cable is provided or if an alternate cable is required, use high quality shielded cabling to maintain compliance with FCC directives.
Canadian Radio Interference Regulations
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet Appareil numérique de la classe B respecte toutes les exigences de Règlement sur le matériel du Canada.
Warranty
Sealevel’s commitment to providing the best I/O solutions is reflected in the Lifetime Warranty that is standard on all Sealevel manufactured I/O products. We are able to offer this warranty due to our control of manufacturing quality and the historically high reliability of our products in the field. Sealevel products are designed and manufactured at its Liberty, South Carolina facility, allowing direct control over product development, production, burn- in and testing. Sealevel achieved ISO 9001:2015 certification in 2018.
Warranty Policy
Sealevel Systems, Inc. (hereafter “Sealevel”) warrants that the Product shall conform to and perform in accordance with published technical specifications and shall be free of defects in materials and workmanship for the warranty period. In the event of failure, Sealevel will repair or replace the product at Sealevel’s sole discretion. Failures resulting from misapplication or misuse of the Product, failure to adhere to any specifications or instructions, or failure resulting from neglect, abuse, accidents, or acts of nature are not covered under this warranty.
Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase. Customer agrees to insure the Product or assume the risk of loss or damage in transit, to prepay shipping charges to Sealevel, and to use the original shipping container or equivalent. Warranty is valid only for original purchaser and is not transferable.
This warranty applies to Sealevel manufactured Product. Product purchased through Sealevel but manufactured by a third party will retain the original manufacturer’s warranty.
Non-Warranty Repair/Retest
Products returned due to damage or misuse and Products retested with no problem found are subject to repair/retest charges. A purchase order or credit card number and authorization must be provided in order to obtain an RMA (Return Merchandise Authorization) number prior to returning Product.
How to obtain an RMA (Return Merchandise Authorization)
If you need to return a product for warranty or non-warranty repair, you must
first obtain an RMA number.
Please contact Sealevel Systems, Inc. Technical Support for assistance:
Available Monday – Friday, 8:00AM to 5:00PM EST
Phone 864-843-4343
Email support@sealevel.com
Trademarks
Sealevel Systems, Incorporated acknowledges that all trademarks referenced in this manual are the service mark, trademark, or registered trademark of the respective company.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>