SEALEVEL Ultra-SIO 3089 2-Port Serial Interface
Introduction
The Sealevel Systems Ultra-SIO provides the PC with two additional ground isolated RS-422/485 (P/N 3189) or two non-isolated RS-422/485 (P/N 3089) serial ports for terminals, modems, printers, etc. Isolation is important in installations where the equipment being connected to the PC is either far from the PC, or on a different power transformer circuit. Ground loop current is a commonly neglected and misunderstood phenomenon that leads to data loss and the possible destruction of communications interfaces. The isolated Ultra-SIO provides up to 500 volts DC of isolation.
Before You Get Started
What’s Included
The Ultra-SIO is shipped with the following items. If any of these items are
missing or damaged, contact the supplier.
- Ultra-SIO Serial I/O Adapter (P/N 3189 with isolation or P/N 3089 without isolation)
Advisory Conventions
-
Warning
The highest level of importance used to stress a condition where damage could result to the product, or the user could suffer serious injury. -
Important
The middle level of importance used to highlight information that might not seem obvious or a situation that could cause the product to fail. -
Note
The lowest level of importance used to provide background information, additional tips, or other non-critical facts that will not affect the use of the product.
Factory Default Settings
The Ultra-SIO factory default settings are as follows:
Port #| Base Address| IRQ| Electrical
Specification
---|---|---|---
Port 1| 3E8| 5| RS-422
Port 2| 2E8| 10| RS-422
To install the Ultra-SIO using factory default settings, refer to Installation
on page Error! Bookmark not defined.
For your reference, record installed Ultra-SIO settings below:
Port #| Base Address| IRQ| Electrical
Specification
---|---|---|---
| | |
| | |
Card Setup
The Ultra-SIO contains several jumper straps that must be set for proper operation.
Address Selection
Each port on the Ultra-SIO occupies eight consecutive I/O locations. A DIP-
switch is used to set the base address for these locations. SW1 sets the I/O
address for port 1 and SW2 sets port 2. The following table shows the
addressing options available. If different address options are required,
please contact Sealevel Systems Technical Support about a custom PAL option.
1 | 2 | 3 | 4 | |
---|---|---|---|---|
3F8 | On | On | On | On |
2F8 | On | On | Off | On |
3E8 | On | Off | On | On |
2E8 | On | Off | Off | On |
2A0 | Off | On | On | On |
300 | Off | On | Off | On |
328 | Off | Off | On | On |
Disabled | Off | Off | Off | Off |
Refer to Appendix A for common address contentions.
Port Enable / Disable
Each port on the Ultra-SIO can be enabled or disabled with switch position 4
on the DIP-switch. The port is enabled with the switch ‘On’ and disabled when
‘Off’. If any port is disabled, be sure to disable the interrupt request for
that port by removing the IRQ jumper.
IRQ Selection
Headers E11 and E12 select the interrupt request for each serial port. If
COM1: is selected, the corresponding jumper must be on the IRQ4 setting. If
COM2: is selected, the corresponding jumper must be on IRQ3.
Most communications software applications default COM3: to IRQ4 and COM4: to IRQ3. This requires the sharing of interrupts between COM1: and COM3:, and between COM2: and COM4:. While this is the default, it is not always the preferred setting. Check your software configuration instructions to determine the most appropriate IRQ selection.
Any two or more ports can share a common IRQ by placing the jumpers on the same IRQ setting at header E11 and E12 and setting the appropriate selections at E5 and E6. Note that a polling type driver is needed to share interrupts in this fashion. Windows does not supply a polling type driver. Consult your software for IRQ selection. If no interrupt is desired, remove the jumper.
Interrupt Modes
Header E5 and E6 selects the interrupt mode for each port. Each port must be
set in the correct mode to insure proper operation.
‘N’ indicates the (N)ormal, single interrupt per port mode. ‘S’ Indicates the
(S)hared interrupt mode, which allows more than one port to access a single
IRQ. Any two or more ports can share a common IRQ by placing the jumpers on
the same IRQ setting and setting the appropriate selections at E1. Consult
your particular software for IRQ selection. If no interrupt is desired, remove
the jumper. ‘M’ indicates the inclusion of a 1K ohm pull-down resistor
required on one port when sharing interrupts.
Set the jumpers to ‘S’ for shared interrupt mode on all blocks sharing an IRQ except one. Set that port block for ‘M’. This provides the pull-down resistor circuit that makes sharing IRQs possible. If you are using more than one Ultra-SIO or a compatible adapter in a bus, you should only have one port set to ‘M’. The following example shows both ports sharing a single IRQ.
Set the jumper to ‘S’ if you are using more than one Ultra-SIO in a bus or to completely remove the pull-down resistor for hardware compatibility. Setting the adapter in this configuration when it is not accompanied by a pull-down resistor will prevent the ports from triggering an interrupt.
RS-485 Enable Modes
RS-485 is ideal for multi-drop or network environments. RS-485 requires a tri-
state driver (not dual-state) that will allow the electrical presence of the
driver to be removed from the line. The driver is in a tri-state or high-
impedance condition when this occurs. Only one driver may be active at a time
and the other driver(s) must be tri-stated. The output modem control signal
Request To Send (RTS) is typically used to control the state of the driver.
Some communication software packages refer to RS-485 as RTS enable or RTS
block mode transfer.
One of the unique features of the Ultra-SIO is the ability to be RS-485
compatible without the need for special software or drivers. This ability is
especially useful in Windows, Windows NT, and OS/2 environments where the
lower level I/O control is abstracted from the application program. This
ability means that the user can effectively use the Ultra-SIO in a RS-485
application with existing (i.e., standard RS-232) software drivers.
Headers E8 (Port 1) and E10 (Port 2) are used to control the RS-485 mode
functions for the driver circuit. The two selections are ‘RTS’ enable or
‘Auto’ enable. The ‘Auto’ enable feature automatically enables/disables the
RS-485 interface. The ‘RTS’ mode uses the ‘RTS’ modem control signal to enable
the RS-485 interface and provides backward compatibility with existing
software products. If you have E3 and E9 in the RS-422 mode and wish to have
the RTS signal present at the DB connector place a jumper over the RTS pins at
E8 and E10. Otherwise, the RTS control signal will not be present at the DB
connector.
Headers E3 (Port 1) and E9 (Port 2) are used to control the RS-485 enable/disable functions for the receiver circuit and determine the state of the RS-422/485 driver. The RS-485 ‘Echo’ is the result of connecting the receiver inputs to the transmitter outputs. Every time a character is transmitted; it is also received. This can be beneficial if the software can handle echoing (i.e., using received characters to throttle the transmitter) or it can confuse the system if the software does not. These header blocks are described in the illustration and table that follow:
Position 1 ‘Echo’| Echoes the data that is transmitted. All characters
transmitted are received. (Only relevant in the two wire RS-485 Mode)
---|---
Position 2 ‘No Echo’| Inhibits the data that has been transmitted. Receiver is
off when transmitter is on. (Only relevant in the two wire RS-485 Mode)
Position 3 ‘422’| RS-422/485 Driver always enabled (RS-422 Mode). RTS modem
control signal available on DB-9 connector.
Position 4 ‘485’| RS-422/485 Driver enabled by RTS or ‘Auto’ enabled. Modem
control signal not available on DB-9 connector.
Interface Mode Examples
Line Termination
Typically, each end of the RS-485 bus must have line terminating resistors
(RS-422 terminates at the receive end only). A 120-ohm resistor is across each
RS-530/422/485 input in addition to a 1K ohm pull-up/pull-down combination
that bias the receiver inputs. Headers E1 and E4 allow the user to customize
this interface to their specific requirements. Each jumper position
corresponds to a specific portion of the interface. If multiple Ultra-SIO
adapters are configured in a RS-485 network, only the boards on each end
should have jumpers T, P & P ON. Refer to the following table for each
position’s operation:
Name | Function |
---|---|
L | Connects the TX+ to RX+ for RS-485 two wire operation. |
T | Adds or removes the 120-ohm termination. |
L | Connects the TX- to RX- for RS-485 two wire operation. |
P | Adds or removes the 1K ohm pull-down resistor in the RS-422/RS- 485 |
receiver circuit (Receive data only).
P| Adds or removes the 1K ohm pull-up resistor in the RS-422/RS-485 receiver
circuit (Receive data only).
Installation
Software Installation
Windows Installation
Do not install the Adapter in the machine until the software has been fully
installed.
Only users running Windows 7 or newer should utilize these instructions for
accessing and installing the appropriate driver via Sealevel’s website. If you
are utilizing an operating system prior to Windows 7, please contact Sealevel
by calling 864.843.4343 or emailing
support@sealevel.com to receive access to the
proper driver download and installation instructions.
- Begin by locating, selecting, and installing the correct software from the Sealevel software driver database.
- Select the Part Number (3189) for your device from the listing.
- Click the ‘Install Drivers’ button.
- The setup file will automatically detect the operating environment and install the proper components.
To confirm that the SeaCOM driver has been successfully installed, click on
the ‘Start’ button, and then select ‘All Programs’. You should see the
‘SeaCOM’ program folder listed.
You are now ready to proceed with connecting the 3189 to your system. Refer to
the Hardware Installation section for details.
Linux Installation
- You MUST have “root” privileges to install the software and drivers.
- The syntax is case sensitive.
SeaCOM for Linux can be downloaded here: https://www.sealevel.com/support /software-seacom-linux/. It includes the README and the Serial-HOWTO help files (located at seacom/dox/howto). This series of files both explains typical Linux serial implementations and informs the user about Linux syntax and preferred practices.
- User can use a program such as 7-Zip to extract the tar.gz file.
In addition, the software selectable interface settings can be accessed by
referencing seacom/utilities/3189mode.
For additional software support, including QNX, please call Sealevel Systems’
Technical Support, 864-843-4343. Our
technical support is free and available from 8:00 AM – 5:00 PM Eastern Time,
Monday through Friday. For email support contact:
support@sealevel.com.
Technical Description
The Sealevel Systems Ultra-SIO provides the PC with two additional ground
isolated RS-422/485 (P/N 3189) or two non-isolated RS-422/485 (P/N 3089)
serial ports for terminals, modems, printers, etc. Isolation is important in
installations where the equipment being connected to the PC is either far from
the PC, or on a different power transformer circuit. Ground loop current is a
commonly neglected and misunderstood phenomena that leads to data loss and the
destruction of communications interfaces. The Ultra-SIO isolated boards
provide up to 500 volts DC of isolation.
The Ultra-SIO utilizes the 16550 UART. This chip features programmable baud
rate, data format, interrupt control and a 16-byte input and output FIFO. A
full array of UART upgrades is also available offering larger FIFO’s. Contact
technical support for details.
Features
- Automatic RS-485 driver enable/disable allows card to appear to be RS-232 requiring no additional drivers
- ‘PAL’ option allows for unique OEM address selection
- ‘Shareable’ IRQs allow more than one port to share a single IRQ providing a polling type driver is used.
- IRQs 2/9-7, 10, 11, 12, 14, 15 supported
- 16550 buffered UARTs Standard
- 16 Bit address decode allows for easier integration
Connector Pin Assignments (DB 9 MALE)
Signal | Name | Pin # | Mode |
---|---|---|---|
GND | Ground | 5 | |
TX + | Transmit Data Positive | 4 | Output |
TX- | Transmit Data Negative | 3 | Output |
RTS+ | Request To Send Positive | 6 | Output |
RTS- | Request To Send Negative | 7 | Output |
RX+ | Receive Data Positive | 1 | Input |
RX- | Receive Data Negative | 2 | Input |
CTS+ | Clear To Send Positive | 9 | Input |
CTS- | Clear To Send Negative | 8 | Input |
Specifications
Environmental Specifications
Specification | Operating | Storage |
---|---|---|
Temperature Range | 0º to 70º C (32º to 158º F) | -50º to 105º C (-58º |
to 221º F)
Humidity Range| 10 to 90% R.H. Non-Condensing| 10 to 90% R.H. Non-
Condensing
Manufacturing
All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and
are 100% electrically tested. These printed circuit boards are solder mask
over bare copper or solder mask over tin nickel.
Power Consumption
Supply line | +5 VDC |
---|---|
Rating | 600 mA |
Physical Dimensions
Board length | 7.35 inches (18.67 cm) |
---|---|
Board height including Goldfingers | 4.2 inches (10.66 cm) |
Board height excluding Goldfingers | 3.9 inches (9.91 cm) |
Appendix
Appendix A – Troubleshooting
The adapter should provide years of trouble-free service. However, in the
event that device appears to not be functioning incorrectly, the following
tips can eliminate most common problems without the need to call Technical
Support.
-
Identify all I/O adapters currently installed in your system. This includes your on-board serial ports, controller cards, sound cards etc. The I/O addresses used by these adapters, as well as the IRQ (if any) should be identified.
-
Configure your Sealevel Systems adapter so that there is no conflict with currently installed adapters. No two adapters can occupy the same I/O address.
-
Make sure the Sealevel Systems adapter is using a unique IRQ The IRQ is typically selected via an on-board header block. Refer to the section on Card Setup for help in choosing an I/O address and IRQ.
-
Make sure the Sealevel Systems adapter is securely installed in a motherboard slot.
-
If you are utilizing an operating system prior to Windows 7, please contact Sealevel by calling (864)
843- 4343 or emailing support@sealevel.com to receive more information in regard to the utility software which will determine if your product is functioning properly. -
Only users running Windows 7 or newer should utilize the diagnostic tool ‘WinSSD’ installed in the SeaCOM folder on the Start Menu during the setup process. First find the ports using the Device Manager, then use ‘WinSSD’ to verify that the ports are functional.
-
Always use the Sealevel Systems diagnostic software when troubleshooting a problem. This will help eliminate any software issues and identify any hardware conflicts.
If these steps do not solve your problem, please call Sealevel Systems’ Technical Support, 864-843-4343. Our technical support is free and available from 8:00 A.M.- 5:00 P.M. Eastern Time Monday through Friday. For email support contact support@sealevel.com.
Appendix B – How To Get Assistance
Please refer to Troubleshooting Guide prior to calling Technical Support.
- Begin by reading through the Trouble Shooting Guide in Appendix A. If assistance is still needed please see below.
- When calling for technical assistance, please have your user manual and current adapter settings. If possible, please have the adapter installed in a computer ready to run diagnostics.
- Sealevel Systems provides an FAQ section on its web site. Please refer to this to answer many common questions. This section can be found at http://www.sealevel.com/faq.asp.
- Sealevel Systems maintains a web page on the Internet. Our home page address is www.sealevel.com. The latest software updates, and newest manuals are available via our web site.
- Technical support is available Monday to Friday from 8:00 A.M. to 5:00 P.M. Eastern Time. Technical support can be reached at 864-843-4343. For email support contact support@sealevel.com.
RETURN AUTHORIZATION MUST BE OBTAINED FROM SEALEVEL SYSTEMS BEFORE RETURNED MERCHANDISE WILL BE ACCEPTED. AUTHORIZATION CAN BE OBTAINED BY CALLING SEALEVEL SYSTEMS AND REQUESTING A RETURN MERCHANDISE AUTHORIZATION (RMA) NUMBER.
Appendix C – Electrical Interface
RS-422
The RS-422 specification defines the electrical characteristics of balanced
voltage digital interface circuits. RS-422 is a differential interface that
defines voltage levels and driver/receiver electrical specifications. On a
differential interface, logic levels are defined by the difference in voltage
between a pair of outputs or inputs. In contrast, a single ended interface,
for example RS-232, defines the logic levels as the difference in voltage
between a single signal and a common ground connection. Differential
interfaces are typically more immune to noise or voltage spikes that may occur
on the communication lines. Differential interfaces also have greater drive
capabilities that allow for longer cable lengths. RS-422 is rated up to 10
Megabits per second and can have cabling 4000 feet long. RS-422 also defines
driver and receiver electrical characteristics that will allow 1 driver and up
to 32 receivers on the line at once. RS-422 signal levels range from 0 to +5
volts. RS-422 does not define a physical connector.
RS-485
RS-485 is backwardly compatible with RS-422; however, it is optimized for
party line or multi-drop applications. The output of the RS-422/485 driver is
capable of being Active (enabled) or Tri-State (disabled). This capability
allows multiple ports to be connected in a multi-drop bus and selectively
polled. RS-485 allows cable lengths up to 4000 feet and data rates up to 10
Megabits per second. The signal levels for RS-485 are the same as those
defined by RS-422. RS-485 has electrical characteristics that allow for 32
drivers and 32 receivers to be connected to one line. This interface is ideal
for multi-drop or network environments. RS-485 tri-state driver (not dual-
state) will allow the electrical presence of the driver to be removed from the
line. Only one driver may be active at a time and the other driver(s) must be
tri-stated. RS-485 can be cabled in two ways, two wire and four wire mode. Two
wire mode does not allow for full duplex communication and requires that data
be transferred in only one direction at a time. For half-duplex operation, the
two transmit pins should be connected to the two receive pins (Tx+ to Rx+ and
Tx- to Rx-). Four wire mode allows full duplex data transfers. RS-485 does not
define a connector pin-out or a set of modem control signals. RS-485 does not
define a physical connector.
Appendix D – Ground Loop Phenomenon
What is Ground Loop?
Ground loop Phenomenon occurs when two (or more) pieces of equipment are
connected together with a common ground and a different ground potential
exists at each location. This current can cause the connected equipment to
experience noise that in turn causes data transmission errors. In the extreme
this ground current can cause equipment malfunction or even destruction.
Cabling Recommendations
When connecting the Ultra-SIO in a RS-485 network, care should be taken that
both ends of the network are not isolated from ground (see Figure 12). This
“floating” ground condition could cause the capacitive or inductive coupling
of voltages that will cause a break down in the DC to DC converter circuit or
in the opto-isolator circuit. This condition will cause data errors and
possibly destruction of the receiver circuit.
Appendix E – Asynchronous Communications
Serial data communications implies that individual bits of a character are
transmitted consecutively to a receiver that assembles the bits back into a
character. Data rate, error checking, handshaking, and character framing
(start/stop bits) are pre-defined and must correspond at both the transmitting
and receiving ends.
Asynchronous communications is the standard means of serial data communication
for PC compatibles and PS/2 computers. The original PC was equipped with a
communication or COM: port that was designed around an 8250 Universal
Asynchronous Receiver Transmitter (UART). This device allows asynchronous
serial data to be transferred through a simple and straightforward programming
interface. A start bit, followed by a pre-defined number of data bits (5, 6,
7, or 8) defines character boundaries for asynchronous communications. The end
of the character is defined by the transmission of a pre-defined number of
stop bits (usually 1, 1.5 or 2). An extra bit used for error detection is
often appended before the stop bits.
This special bit is called the parity bit. Parity is a simple method of determining if a data bit has been lost or corrupted during transmission. There are several methods for implementing a parity check to guard against data corruption. Common methods are called (E)ven Parity or (O)dd Parity. Sometimes parity is not used to detect errors on the data stream. This is referred to as (N)o parity. Because each bit in asynchronous communications is sent consecutively, it is easy to generalize asynchronous communications by stating that each character is wrapped (framed) by pre-defined bits to mark the beginning and end of the serial transmission of the character. The data rate and communication parameters for asynchronous communications have to be the same at both the transmitting and receiving ends. The communication parameters are baud rate, parity, number of data bits per character, and stop bits (i.e.,9600,N,8,1).
Appendix F – Silk Screen
Appendix G – Compliance Notices
Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the limits for
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in such case the user
will be required to correct the interference at the user’s expense.
EMC Directive Statement
Products bearing the CE Label fulfill the requirements of the EMC directive
(89/336/EEC) and of the low-voltage directive (73/23/EEC) issued by the
European Commission. To obey these directives, the following European
standards must be met:
- EN55022 Class A – “Limits and methods of measurement of radio interference characteristics of information technology equipment”
- EN55024 – “Information technology equipment Immunity characteristics Limits and methods of measurement”.
This is a Class A Product. In a domestic environment, this product may cause
radio interference in which case the user may be required to take adequate
measures to prevent or correct the interference.
Always use cabling provided with this product if possible. If no cable is
provided or if an alternate cable is required, use high quality shielded
cabling to maintain compliance with FCC/EMC directives.
Warranty
Sealevel’s commitment to providing the best I/O solutions is reflected in the Lifetime Warranty that is standard on all Sealevel manufactured I/O products. We are able to offer this warranty due to our control of manufacturing quality and the historically high reliability of our products in the field. Sealevel products are designed and manufactured at its Liberty, South Carolina facility, allowing direct control over product development, production, burn- in and testing. Sealevel achieved ISO-9001:2015 certification in 2018.
Warranty Policy
Sealevel Systems, Inc. (hereafter “Sealevel”) warrants that the Product shall
conform to and perform in accordance with published technical specifications
and shall be free of defects in materials and workmanship for the warranty
period. In the event of failure, Sealevel will repair or replace the product
at Sealevel’s sole discretion. Failures resulting from misapplication or
misuse of the Product, failure to adhere to any specifications or
instructions, or failure resulting from neglect, abuse, accidents, or acts of
nature are not covered under this warranty.
Warranty service may be obtained by delivering the Product to Sealevel and
providing proof of purchase. Customer agrees to ensure the Product or assume
the risk of loss or damage in transit, to prepay shipping charges to Sealevel,
and to use the original shipping container or equivalent. Warranty is valid
only for original purchaser and is not transferable.
This warranty applies to Sealevel manufactured Product. Product purchased
through Sealevel but manufactured by a third party will retain the original
manufacturer’s warranty.
Non-Warranty Repair/Retest
Products returned due to damage or misuse and Products retested with no
problem found are subject to repair/retest charges. A purchase order or credit
card number and authorization must be provided in order to obtain an RMA
(Return Merchandise Authorization) number prior to returning Product.
How to obtain an RMA (Return Merchandise Authorization)
If you need to return a product for warranty or non-warranty repair, you must
first obtain an RMA number. Please contact Sealevel Systems, Inc. Technical
Support for assistance:
- Available Monday – Friday, 8:00AM to 5:00PM EST
- Phone 864-843-4343
- Email support@sealevel.com
Trademarks
Sealevel Systems, Incorporated acknowledges that all trademarks referenced in
this manual are the service mark, trademark, or registered trademark of the
respective company.
© Sealevel Systems, Inc. 3089 & 3189 Manual
SL9143 9/2022