CARBEST 82282 Sinus Power Inverter User Guide
- June 14, 2024
- CARBEST
Table of Contents
Sinus Power Inverter
Sinus-Wechselrichter · Pure Sine-Wave Inverter
USER’S INSTRUCTION
82282 Sinus Power Inverter
Read this guide before installing or using the inverter and save it for future reference!
INTRO
Thank you for purchasing this Carbest Power Inverter. From the 12 V outlet in
your vehicle or directly from a dedicated 12 V battery, the inverter will
efficiently and reliably power a wide variety of household AC products, such
as TVs, computers, VRs, etc.
FEATURES
- Pure sine wave output (THD <2%)
- Output frequency: 50/60 Hz switch selections.
- Input & output completely isolated design
- High efficiency 84 – 94%
- Capable of driving inductive & capacitive loads at the start moment.
- A LED indicator with twin color displays all operation status.
- Loading and temperature controlled cooling fan.
- Built in advanced microprocessor for an user friendly interface.
- Protection: Input low voltage alarm & shutdown, overload, short circuit, input over voltage, over temperature, reverse polarity
- USB output port 5 V, 2.1 A.
All connection cables included: 2x 2.0 m and in addition 1x 0.4 m cable.
Inverter model | Cable diameter |
---|---|
700 Watt | Ø 16 mm² |
1000 Watt | Ø 25 mm² |
1500 Watt | Ø 50 mm² |
2000 Watt | Ø 50 mm² |
3000 Watt | Ø 50 mm² |
Fuses are not included. We recommend following 12 V fuses:
Inverter Fuse
700 W + 1000 W 100 A
1500 W 150 A
2000 W 200 A
3000 W 300 A
IMPORTANT SAFETY INFORMATION
WARNING
Before installing and using the inverter, you need to read the following
safety information carefully.
General safety precautions
-
Do not expose the inverter to rain, snow, spray, bilge or dust.
To reduce risk of hazard, do not cover or obstruct the ventilation openings.
Do not install the inverter in a zero-clearance compartment, over heating may result. -
Do avoid a risk of fire and electronic shock. Make sure that existing wiring is in good electrical condition; and that wire size is not undersized.
Do not operate the inverter with damaged or substandard wiring. -
This equipment contains components which can produce arcs or sparks.
-
To prevent fire or explosion, do not install in compartments containing batteries or flammable materials or in locations where require ignition protected equipment, this includes any space containing gasoline-powered machinery, fuel tanks, or joints, fittings, or other connection between components of the fuel system.
Precautions when working with batteries -
If battery acid contacts skin or clothing, washes immediately with soap and water.
If acid enters eye, immediately flood eye with running cold water for at least 20 minutes and get medical attention immediately. -
Never smoke or allow a spark or flame in vicinity of battery or engine.
-
Do not drop a metal tool on the battery. The resulting sparks or short-circuits on the battery of other electrical part may cause an explosion.
-
Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a battery.
A battery produces a short-circuit current high enough to weld a ring or metal, causing severe burns.
MECHANICAL DRAWINGS (unit mm)
INSTRUCTION
To get the most out of the power inverter, it must be installed and used
properly.
Please read the instructions in this manual before installation and operation.
- Chassis ground
- Remote control port
- Cooling fan
- Input battery connectors (red + / black -)
Optional: Remote control incl. 5 m cable (Item no.: 81947)
- Main Switch
- USB output port (5 V, 2.1 A)
- Output outlets
- Load level LED
- Status LED
- Dip switch
Dip switch | Settings |
---|---|
S4 | 0: 50 HZ |
S3 | 0: OFF |
S2 | 0: OFF |
S1 | 0: OFF |
LED indicators
Load level| < 20 %| off
between 20 % and 50 %| green
between 50 % and 90 %| orange
90 %| red
Status| Power on| green
Fault/protection| red
Main switchON| Power on the inverter
OFF| Power off the inverter
Remote| Setting the inverter to control by remote controller
NOTES
- Before installing the inverter make sure the main switch must be OFF.
- Before using the remote unit make sure the main switch must be Remote.
- Ensure the remote control setting is off.
DC input terminals
Connect to 12 V battery or the other power sources. (+) is positive, (-) is
negative. Reverse polarity connection will blow internal fuse and may damage
inverter permanently.
Model | DC input voltage |
---|---|
Minimum | Maximum |
12 V | 10,5 V |
Protection features
Modell| DC input (VDC)| Over temperature
protection
---|---|---
Over voltage| Under voltage| |
Shutdown| Restart| Alarm| Shutdown| Restart|
Shutdown| Restart
12 V| 16 V| 13 V| 11 V| <10,5 V| 12,5 V| 55 °C| 45 °C
NOTE
The specifications are subject to change without notice.
INSTALLATION
Please use the provided cables to connect the unit to the battery.
The input terminals on the rear side of the unit are Red (Positive) and Black
(Negative).
Connect the red cable to the red terminal and to the positive pole of the
battery. Connect the black cable to the black terminal and to the negative
pole of the battery.
It is strictly recommended to add a fuse as close as possible to the positive
pole of battery.
Make sure all connections are solid and secured. Poor connections may cause
overheating the cable and shorten the battery backup time.
Ensure that the inverter is OFF before connecting with the battery.
WARNING
The installation of a fuse must be on positive cable. A missing fuse on the
positive cable between the inverter and battery may cause damage to the
inverter and will void warranty.
INVERTER OPERATION
To operate the power inverter, turn the main switch ON, the power inverter is now ready to deliver AC power to your loads. If there are several loads, turn them on separately after the inverter has been ON in order to prevent an electrical overload.
- Set the power switch to the ON position and the buzzer will send out Beep sounds at the moment the inverter will do self-diagnosis. Then the power status LED indicators will also show various colors, finally the buzzer will sound another Beep and the power status LED indicators will turn to green color. The inverter starts working successfully.
- Set the power switch to the OFF position, the inverter stops and all the lights will go off.
TROUBLESHOOTING
WARNING:
Do not open or disassemble the inverter. Attempting to service the unit
yourself may result in a risk of electrical shock or fire.
Problems & Symptoms | Possible cause | Solutions |
---|
No AC power output
and status illuminates
the red LED| Over input voltage (OVP)| Check input voltage, reduce input
voltage.
Low input voltage (UVP)| Recharge battery, check connections and cable.
Thermal shutdown (OTP)| Improve ventilation. Make sure ventilation openings in
inverter are not obstructed. Reduce ambient temperature
Short circuit or wiring error. Over load (OLP)| Check AC wiring for short
circuit. Reduce load.
MAINTENANCE
Very little maintenance is required to keep your inverter operating properly. You should clean the exterior of the unit periodically with a damp cloth to prevent accumulation of dust and dirt. At the same time, tighten the screws on the DC input terminals.
WARRANTY
The warranty period is 36 months. Reimo reserves the right to rectify eventual
defaults. The guarantee is excluded for all damages caused by faulty use or
improper handling. Liability limitations: In no case Reimo will be reliable
for collateral-, secondary- or indirect damages, costs, expenditure, missed
benefits or missed earnings. The indicated sales price of the product is
representing the equivalent value of Reimo’s liability limitations.
DISPOSAL
Environmental Information for Customers in the European Union European
Directive 2002/96/EC requires that the equipment bearing this symbol on the
product and/or its packaging must not be disposed of with unsored municipal
waste. The symbol indicates that this product should be disposed of separately
from regular household waste streams. It is your responsibility to dispose of
this and other electric and electronic equipment via designated collection
facilities appointed by the government or local authorities. Correct disposal
and recycling will help prevent potential negative consequences to the
environment and human health. For more detailed information about the disposal
of your old equipment, please contact your local authorities, waste disposal
service, or the shop where you purchased the product.
REIMO REISEMOBIL-CENTER GMBH 63329 EGELSBACH · BOSCHRING 10
GERMANY ·WWW.REIMO.COM
MADE IN CHINA · © REIMO 06/2023
Documents / Resources
|
CARBEST 82282 Sinus Power
Inverter
[pdf] User Guide
82282 Sinus Power Inverter, 82282, Sinus Power Inverter, Power Inverter
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>