AquaOne HW-302 Outside Filter Instruction Manual
- June 14, 2024
- AquaOne
Table of Contents
AquaOne HW-302 Outside Filter
Thank you for purchasing an AquaOne HW Series outside filter. Read the user manual carefully before use to ensure you use the device properly.
Guarantee
The warranty term is 2 years, valid from the date ofthe sales invoice (also
the date of purchase). Quick-ware parts of the pump are beyond the scope of
guarantee. The damage caused by incorrect use or the contrive damage will be
exempted.
Operation guide
-
To set your filter up, the buckles (1) and (2) should be unclipped from the main body of filter head this will then separate the head from the base of the filter. (PIC 1)
-
Add the filter materials as you like, install all draining skeps in order. Then fasten the barrel head to mian body, close the buckle (1) and (2). (PIC 2)
-
Push the inlet and outlet taps into the filter head and fasten using the small handle in between the taps this is also the shut of valve, After this attach your hose to each tap and secure using the screw caps,(PIC 3)
-
Install the inlet assembly according to the parts list. install the tube to the inlet and tighten the bolt. Fix the whole inlet assembly tot he tank according to (PIC 6), and tighten the screws on the fixing base. And fix the pipe
to the overflow pipe for intake. -
Install the Outlet assembly according to the parts list. lnstall the tube to the inlet and tighten the bolt. Fix the outlet assembly to the tank according to (PIC 6), and tighten the screws on the fixing base. And fix the pipe to the overflow pipe for return.
-
According to the diagram then press down the blue primer button on top of the filter head this will prime the filter drawing water in through the hose. Repeat this if necessary until all pipework is full with water,(PIC 4)
-
Things under the transparent cover are control switch of UV light and indicator of the UV, When the electrical source switch on, you can see the indicator light is shine which means the UV light works normally; lf the indicator light is off which means the UV light tubes have broken, it is necessary to change the UV light tube.(PIC 5)
The method of replacing the uv light tube
- Open the filter head from the main body careffully, turn the head upside down. Loosen the two screws around the quartz sleeve (PIC 1). Then gently turn the quartz to release it fro, the filter head (PIC 2).
- Pull the UV bulb out from the filter head to then replace (PIC3).
- Finally install a new UV bulb, and assemblythe filter.
HW-304B diagram of replacement
- According to the diagrammatic presentation, please open the lid from the mail body carefully. Put the lid in inversion, then hold the quartz tube and circumgyrate in lightly, just as the left picture shows. When the gap of the quartz tube and the gap of the connection of the light tubes are accordant, pull out the quartz tube.
- According to the diagrammatic representation, pulling out the bad light tube.
- Installing the new light tube and the quartzose tube.
Product Specifications
Model| Voltage| Power| H- Max| Output| UV
Power
---|---|---|---|---|---
HW-302| ****
AC 220- 240V/50H
z
| 18W| 1,4m| 1000 L/h| –
HW-303A| 35W| 2,0m| 1400 L/h| –
HW-303B| 35W| 2,0m| 1400 L/h| 5W/7W/9W
HW-304A| 55W| 2,5m| 2000 L/h| –
HW-304B| 55W| 2,5m| 2000 L/h| 5W/7W/9W
Filter Management
Problem | Cause | Solution |
---|---|---|
Pressing the inhale Buckle (blue buckle), the fitter has no response | The | |
wrang join of input and output bar | Join input and output bar again | |
Tue power is off | Turn on the power | |
Tue shaft is broken | Replace the shafl |
The motor is not operation
| Tue impeller is missing or the molar is clogged with loreign materials such
as pebbles and shells.| Set the impeller or clean out the drive system
lnhibited water flow (inhibited functioning)| ****
Hose adaptor un is excessively dirty
| Detach the hose adaptor uni! and clean the inside with a brush
Hose have been incorrectly connected| Check whether the hose entangled or
crimped
Excessive dirt build-up in the hoses| Periodically clean the inside of the
hoses and the intake an drainage pipes
Filtermedia is clogged| Remove the filter media and wash with tank water
Abnormal sound emitted when staring the filter| Air is entering from the hose
connection.| Check whether the hoses are connected properly.
Air is remaining in the filer case.| Leaving the power on, shake the uni! to
help remove remaining air.
Abnormal sound emitted when operating the filter
| lnsullicient application of Vaseline.| Apply ample Vaseline to all of the
0-rings.
Damaged impeller/drive magnet or spindle.| Replace parts (consult place of
purchase)
Decrease ire water flow die to water staning or dirt or the impeller/drive|
Set the impeller or clean out the drive system
Components
Regulations for waste disposal
The Waste Electrical and Electronic Equipment Directive (WEEE Directive,
2012/19/EU) of the EU was implemented in the German law related to electrical
and electronic equipment and appliances.
All AquaOne electric devices that fall under the WEEE directive are labelled
with the symbol of a crossed- out wheeled rubbish bin. This symbol indicates
that this electric device must not be disposed of with the domestic waste.
Disposal of used electrical and electronic devices (intended for use in the
countries of the European Union and other European countries with a separate
waste collection system for these devices).
The symbol on the packaging or the product itself indicates that this product
must not be treated as normal domestic waste but must be disposed of at a
recycling collection station for electrical and electronic waste.
By disposing of this product correctly, you contribute to the protection of
the environment and the health of your fellow people. Inappropriate disposal
threatens the environment and health.
Material recycling helps to reduce the consumption of raw materials.
Additional information about the recycling of this product can be provided by
your local commune, the municipal waste disposal facilities, or the store
where you purchased the product.