AEGISLINK SC-WF240 Wi-Fi Combination Smoke and Carbon Monoxide Detector User Manual

June 14, 2024
Aegislink

Wi-Fi Combination
Smoke and Carbon Monoxide Alarm
USER MANUAL

AEGISLINK SC-WF240 Wi-Fi Combination Smoke and Carbon Monoxide
Detector Model: SC-WF240

Thank you for purchasing this AEGISLINK SC240-WT Wi-Fi combination smoke and carbon monoxide alma. This user manual contains important information on installing and operating this AEGISLINK Wi-Fi alarm. Please read this user manual before installation or operation, and save i for future reference.

Package Contents

1 Alarm Unit 1x Mounting Bracket
2% Screws 2 Anchor Plugs
1% User Manual 1xPin

Product Profile

AEGISLINK SC-WF240 Wi-Fi Combination Smoke and Carbon Monoxide Detector -
Product Profile| AEGISLINK SC-WF240 Wi-Fi Combination Smoke and Carbon Monoxide
Detector - Product Profile1
---|---

Test/Silence Button
The test/silence button is used to test the unit’s electronics and to silence the unit during an alarm. When testing the alarm weekly, press the test button until you hear a short beep, indicating that the alarm has entered the test mode. Please refer to the ‘Alarm Test” section for further information. The alarm goes back to the standby mode after testing, Note: After a test has begun, the alarm will sound and the LED will lash red. This does nonindicated that smoke/CO is present.
Buzzer
‘The alarm will sound when there is smoke o CO present, when testing the alarm, and when there is a fault.
LED Indicator
The LED indicator will flash in conjunction with the buzzer, Therefore, it will flash during the following states: when powering on, in standby mode, during smoke or CO alarm states, when exiting an alarm state, during test mode, when there is low battery, in silence mode, when there is 2 fault and when the unit s at the end of its Ife.
Low Battery
The LED indicator will lash yellow together with one beep every 60 seconds. (IF you press the test button when there i low battery, the low battery signal will temporarily cease for 10 hours)
End of Life
Once the maximum lifetime (10 years) is reached, the alarm will deliver 3 beeps and the LED indicator will lash yellow 3 times every 60 seconds. This end-of-life signal can be temporarily silenced for 22 hours by pressing the test button.
The end-of-ife silence feature can only be used for a total of 30 days. After 30 days, the end-of-life signal cannot be silenced.
CO Alarm Levels
This combination smoke & carbon monoxide alarm is programmed to sound an alarm at the following CO concentrations within the time periods lasted:
70 ppm for 60-240 minutes,
150 ppm for 10-50 minutes,
and 400 ppm for 4-15 minutes.
CO Concentration and Symptoms
“The table below shows the effects of different levels of CO poisoning on the body:

Parts per Million (PPM) Effects on Adults
100 Slight headache, naoses, fatigue (ulcer symptoms).
200 Dizziness and headache within 2-3 hours,
400 Nausea, rental headache, drowsiness, confusion and rapid heart fate. Risk

1o fee after over 3 hours of exposure.
800| Severe headaches, convulsions, vital organ failures. Death possible within 2-3 hours.

WARNING: Trl5 DEVICE I5 DESIGNED TO PROTECT INDIVIDUALS FROM ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE. IT MAY NOT FULLY SAFEGUARD INDVIDUALS WITH SPECIFIC MEDICAL CONDITIONS. IF IN DOUBT, CONSULT A MEDICAL PRACTITIONER.

Basic Safety Information

DANGERS, WARNINGS, AND CAUTIONS ALERT YOU TO IMPORTANT INSTALLATION AND OPERATING INSTRUCTIONS, OR POTENTIAL HAZARDS. PLEASE PAY ATTENTION TO THE SITUATIONS,
IMPORTANT

  1. DANGERS, WARNINGS, AND CAUTIONS ALERT YOU TO IMPORTANT OPERATING INSTRUCTIONS ORTO POTENTIALLY HAZARDOUS SITUATIONS. PAY SPECIAL ATTENTION TO THESE SITUATIONS,
  2. THIS COMBINATION SMOKE & CARBON MONOXIDE ALARM IS ONLY APPROVED FOR HOME USE.
  3. HIS CARBON MONOXIDE ALARM IS DESIGNED TO DETECT CARBON MONOXIDE FROM ANY SOURCE OF COMBUSTION.
  4. CONSTANT EXPOSURES TO HIGH OR LOW HUMIDITY MAY REDUCE BATTERY LIFE.
  5. SMOKE ALARMS ARE NOT TO BE USED WITH DETECTOR GUARDS UNLESS THE COMBINATION HAS BEEN EVALUATED AND FOUND SUITABLE FOR THAT PURPOSE.

WARNING

  1. NEVER IGNORE ANY ALARM. FAILURE TO RESPOND CAN RESULT IN SERIOUS INJURY OR DEATH
  2. THE SILENCE FEATURE IS ONLY FOR YOUR CONVENIENCE AND WILL NOT CORRECT A PROBLEM. ALWAYS CHECK YOUR HOME FOR A POTENTIAL PROBLEM AFTER ANY ALARM. FAILURE TO DO SO CAN RESULT IN INJURY OR  DEATH
  3. TEST THIS SMOKE/CO ALARM ONCE A WEEK. IF THE ALARM EVER FAILS TOTEST CORRECTLY, REPLACE IT IMMEDIATELY! IF THE ALARM CANNOT WORK PROPERLY, IT WILL NOT ALERT YOU TO A PROBLEM.
  4. THIS PRODUCT IS INTENDED FOR USE IN ORDINARY INDOOR LOCATIONS OF FAMILY LIVING UNITS. T 15 NOT DESIGNED TO MEASURE CO LEVELS IN COMPLIANCE WITH OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) COMMERCIAL OR INDUSTRIAL STANDARDS. INDIVIDUALS WITH MEDICAL CONDITIONS THAT MAY MAKE THEM MORE SENSITIVE TO CARBON MONOXIDE MAY CONSIDER USING WARNING DEVICES WHICH PROVIDE AUDIBLE AND VISUAL SIGNALS FOR CARBON MONOXIDE CONCENTRATIONS UNDER 30 PPM. FOR ADDITIONAL INFORMATION ON CARBON MONOXIDE AND YOUR MEDICAL CONDITION CONTACT YOUR PHYSICIAN.
  5. THE REPLACEMENT DATE THAT APPEARS ON THE DEVICE IS THE DATE BEYONDWHICH THE DEVICE MAY NO LONGER DETECT CARBON MONOXIDE ACCURATELY AND SHOULD. BE IMMEDIATELY REPLACED.
  6. THIS DEVICE 1S DESIGNED TO PROTECT INDIVIDUALS FROM THE ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE. IT MAY NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS. IF IN DOUBT, CONSULT A MEDICAL PRACTITIONER.

Set Up and Connect Combination Smoke and Carbon Monoxide Alarms to Wi-Fi

Before connecting combination smoke and carbon monoxide alarms, make sure that:

  1. Make sure you only work with 2 units at a time, and that they are both activated to ensure successful connection.
  2. Make sure you are connecting alarms to a 2.4 GHz Wi-Fi network (incompatible with 5 GHz Wi-Fi network).

NOTES:

  • Make sure you turn on some permissions in the mobile phone settings. Otherwise, the app cannot add devices or will fail to receive push notifications.
  • Some contents shown in the App user interface might slightly differ from those in the user manual due to later software upgrades.

How to connect using EZ mode (Default mode)

  1. Before installing the alarm to a wall or ceiling, download the Tuya Smart/Smart Life app and connect the alarm to your Wi-Fi via the app. Search for Tuya Smart/Smart Life in the App Store or Google Play, or simply scan the included QR code to install the Tuya Smart/Smart Life app. You will also need to register an account.
    |
    ---|---
    https://smartapp.tuya.com/tuyasmart| https://smartapp.tuya.com/smartlife

  2. Remove the insulating film from the battery compartment to turn on the alarm The LED indicator will flash red and then continuously flash green, indicating that the alarm has been activated.

  3. 0pen the Tuya Smart/Smart Life app, tap the +icon in the top right comer of the “Home” page, or directly tapAdd Device” to add your first device.

  4. Go to “Sensors’ – > “Sensor/Alarm’- > “Sensor/Alarm (Wi-Fi)” on the *Add Manually” page to enter the Wi-Fi connecting page.

  5. Enter the Wi-Fi password.
    NOTE: If your home Wi-Fi router is a 2.4 and 5 GHz dual-band that works with a single SSID name, please refer to your Wi-Fi router manual to create separate SSIDs for the
    2.4 and 5 GHz channels. You can also select “Common router setting method” on the Tuya Smart/Smart Life App in the network configuration process to learn about the corresponding setting method.

  6. To enable the alarm to enter the Wi-Fi connection mode, hold down the test/silence  button for 3 seconds. The alarm will beep once, and the LED indicator will rapidly flash green.

  7. After a successful connection, the LED indicator will stop flashing green. At this time, click the button “+ beside the device to successfully add the device. Then, select” Done’ The added device will now be displayed on the Home page in the app.
    NOTE: If you select “Done” without clicking “+”, you will be reminded to choose to add advice in the app.
    NOTES
    • The LED indicator will flash green rapidly for up to 2 minutes during configuration. If connection is unsuccessful, the alarm will need to be reconnected. Remove the battery for assort period and start again from step 2.
    • Unsuccessful connection may be because your router, mobile phone, and alarm are not as close to each other as possible, or that you have incorrectly entered your Wi-Fi Password!.

  8. 0nce you have successfully connected your device to the app, you can continue to the “Settings’ section to set up push notifications and change various settings for the 2pp and device. However, if the device still cannot connect to the app, you can try to set up the device using the following AP mode.

How to connect using AP mode (Alternative mode)
Some mobile phones and devices are not compatible with the EZ mode, so you will need 1o switch to the AP mode.

  1. Insert a pin into the device pinhole on the back of the alarm and press down the inside button. The alarm will beep once and the LED indicator will flash green slowly, indicating that the alarm has entered the AP mode.
  2. Go’t0 the WiFi setup page in the phone, and then select the device’s hotspot with the default name “SmartLED-XXXX or “SL-XXXX” After successfully connecting to the Wi-Fi return to the app and start network configuration.
  3. After successful connection, the LED indicator will stop flashing arena and the added device will be displayed on the *Home” page in the 2pp.
    NOTE: When using the EZ (default) mode for network configuration, the LED indicator flashes quickly, on average 4 times per second; when using AP mode for network configuration, the LED indicator flashes slowly, on average once per second.

App Settings

Notifications Settings
Under Settings (the gear wheel on the unit’s home screen) you can adjust the type of notifications you want the combination smoke and carbon monoxide alarm to send. This can apply to both what i displayed on the screen and what s stored in the log.
One thing to keep in mind is that if you turn on many notifications, it may seem as if the device ‘alerts” about something constantly. For example, if you turn on “Device Self-Check Notification’ you will receive a notification every time the unit performs a test after the test/silence button is pressed. The more information you activate, the more power the device will consume, as it creates more need for the device to transmit information, which means that the intervals for battery replacement will become shorter than the advertised one year.
CO Concentration Value
When a CO alarm occurs, the real-time CO concentration level will be displayed in the app.
Apish notification will be sent to your mobile phone via the app.
Offline Notification
If you have an unstable network, it may be good to know how often the alarm loses  connection and to perhaps improve the placement of your Wi-Fi router or change Internet provider. Alternatively, you may wonder why the SC-WF240 loses contact with the Wi-Fi
router or cloud server and flashes green from time to time. Therefore, it is recommend to turn on the “Offline Notification “so that you will receive a push notification if your device cannot connect to the app.
Tur on “Offline Notification’ and a text will appear describing that if the device is battery powered, updates are made every & hours. This information will then be sent from the cloud server due to the device not having made contact within a specified time span. This does not mean that the device or your W-Fi router does not work properly, but for some reason the alarm cannot reach the cloud server at regular intervals and then the warning is sent out.
Alarm Test

  1. Always make sure to test your combination smoke and carbon monoxide alarm when it is turned on for the first time, or whenever you change the battery or reconfigure the device. You should also test the device weekly, or whenever you have been away from home for a long time.
  2. Briefly press the test/silence button. NOTE: if you hold down the button for more than three seconds, the alarm will enter a reconnecting mode in the app and the previous settings will be cleared
  3. The alarm will emit 2 sets of 3 long beeps followed by 2 sets of 4 quick beeps.
  4. your device has successfully connected to router the LED indicator will lash red and then flash green rapidly for several seconds, indicating it has been connected
  5. When the test is finished, the alarm will automatically enter standby mode.

NOTES:

  1. The test function accurately tests the alarm’s circuits without the need to test with smoke and CO. If your alarm fails to give an audible test signal, please immediately refer to the troubleshooting guide at the end of this manual. Never use an open flame to test this device.
  2. If the LED indicator flashes green for 2 minutes during the test, then the connection was not successful and the alarm needs to be reconnected (repeat the steps in the section “Set Up and Connect Combination Smoke and Carbon Monoxide Alarms to Wi-Fi”).

Installation Positioning

AEGISLINK SC-WF240 Wi-Fi Combination Smoke and Carbon Monoxide Detector -
Fig1

NOTE: If a smoke alarm s installed in a kitchen, ensure it has an accessible silence button, and install it as far away from the stove and sink as possible to avoid false alarms.

  1. Prioritize the installation of a smoke alarm in the bedroom and walkways, and make sure you can hear the alarm from all sleeping areas, In @ hoer with several bedrooms, install an alarm in every bedroom. If you install only one smoke alarm in your home, install the alarm near to all bedrooms where possible, and not in a basement or furnace room.
  2. Install an alarm above the stairway and on every floor of the house.
  3. 5moke, heat and anything burning will spread horizontally after rising to the ceiling, o install the alarm in the middle of the ceiling where possible. Ensure that the alarm is installed at the minimum distance away from corner.
  4. Irfan alarm cannot be installed in the middle of a ceiling, install it at a distance of 201in (50 cm) away from the corers of the room.
  5. If an alarm i installed onto a wall, a distance of 4-12n (10-30 cm) should be kept below the ceiling
  6. If the length of a room or hall s beyond 30 ft (900 cm), several alarms should be installed in the same room.
  7. When the wall or ceiling is angled, the alarm needs to be installed within 3 ft (90 cm) of the highest wall or ceiling point (measured horizontally) in the room.
  8. In multi-level houses or apartments, install at least one wireless alarm o each level and keep them installed in a straight vertical line (see diagram) with as few obstacles between each of the interconnected alarms as possible to ensure optimal signal transmission.

AEGISLINK SC-WF240 Wi-Fi Combination Smoke and Carbon Monoxide Detector -
Fig2

WARNING

  1. THIS ALARM SHOULD BE INSTALLED BY A COMPETENT PERSON.
  2.  ALARMS SHOULD NOT BE USED AS A SUBSTITUTE FOR PROPER INSTALLATION, USE AND MAINTENANCE OF FUEL BURNING APPLIANCES INCLUDING APPROPRIATE VENTILATION AND EXHAUST SYSTEMS.
  3. TO PREVENT INJURY, THIS DEVICE SHOULD BE SECURELY ATTACHED WALL IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS, TO THE CEILING OR
  4. BATTERIES SHOULD NOT BE EXPOSED TO EXCESSIVE HEAT SUCH AS DIRECT SUNLIGHT, FIRE, ETC.

Locations to Avoid
WARNING- THIS PRODUCT I5 INTENDED FOR USE IN ORDINARY INDOOR LOCATIONS OF FAMILY LIVING UNITS. T 15 NOT DESIGNED TO MEASURE CO LEVELS IN COMPLIANCE WITH OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) COMMERCIAL OR INDUSTRIAL STANDARDS.

  1. Do not install in garages, kitchens, furnace rooms or bathrooms! Do not install within 5ft (1.5 m) of cooking appliances.
  2. D0 noinstall within 3 t (09 m) of the following: The door to a kitchen, or a bathroom that contains a tub or shower, forced air supply ducts used for heating or cooling, ceiling or whole house ventilating fans, or other high air flow areas. Avoid excessively dusty, dirty or greasy areas. Dust, grease or household chemicals can contaminate the alarms sensors, causing the alarm to not operate properly.
  3. Place the alarm where drapes or other objects will not block the sensors. Smoke and CO must be able o reach the sensors to accurately detect these conditions. Do not install in peaks of vaulted ceilings, A” frame ceilings or gabled roofs. Keep out of damp and humid areas.
  4. Install at least one (1) foot away from fluorescent lights, as electronic noise may cause nuisance alarms,
  5. D0 not place in direct sunlight and keep out of insect-infested areas. Extreme temperatures will affect the sensitivity of the smoke/CO alarm.
  6. D0 not installing areas where the temperature is colder than 40°F (44°C) o hotter than 100°F (37.8°C), such as garages and unfinished attics
  7. Do notinstalled areas where the relative humidity (RH) is above 85% or lower than 10%. Place away from doors and windows that open to the outside.
  8. Smoke alarms are not to be used with detector guards unless the combination (alarm and guard) has been evaluated and found suitable for that purpose.

Installation Method
NOTE: Before installation, we recommend you test the Wi-Fi alarms in the rooms you wish to install them in to ensure they are within range of the Wi-Fi router that nothing i interfering with their communication.

  1. Use the mounting bracket to mark the screw holes on the celling or the wall,
  2. Drill holes at the 2 marks using an appropriately-sized drill bit. Insert the anchor plugs and screw the mounting bracket using the screws provided.
  3. Attach the alarm to the mounting bracket and turn clockwise to lock the alarm
  4. Test the alarm according to the steps in the section “Alarm Test”

AEGISLINK SC-WF240 Wi-Fi Combination Smoke and Carbon Monoxide Detector -
Fig3

Silence Function

If there is a false alarm, you can temporarily silence it by pressing the Mute Switch button on the app or by pressing the test/silence button on the device. The LED indicator will flash red with the same frequency when it s triggered by smoke or CO, and you will receive an instant notification from the app, telling you that the device has been temporarily silenced
Smoke Silence Mode
If the smoke concentration has reached an alarm level, after the silence time has expired, this unit will continue to alarm until the smoke concentration decreases 1o a safe, low level. Otherwise, the alarm will enter the normal mode after 9 minutes,
CO Silence Mode
If the CO density still exceeds the alarm threshold the unit will re-enter alarm state. Otherwise, the unit will exit the silence mode after 9 minutes and resume normal operation.
Note that the silence function will oy silence the alarm for a short period. It will NOT correct any problems

AEGISLINK SC-WF240 Wi-Fi Combination Smoke and Carbon Monoxide Detector -
APP

Device Status Checklist

Mode LCD Display LED Indicator Audible Alarm Remarks
Powering On Runs through 8 cycles (yellow/green/ red) in
sequence. 1 quick beep. Make sure the battery is installed correctly and the

device is turned on.
Wi-Fi Connecting| | The LED indicator flashes rapidly.| 1 beep.| EZ Mode (Default mode).
The LED indicator flashes slowly.| 1 beep.| AP Mode (Alternative mode).
Standby Mode| | Flashes green once every 60 seconds.| None.| None.
Alarm Mode

| Unit detects Smoke and initiates an alarm.| –| Flashes red 3 times every 4 seconds.| 3 long beeps every
4 seconds.| The app will immediately notify you of dangerous smoke/CO near the alarm.
Unit detects CO and initiates an alarm.| | A CO concentration ranging from 30 to 999 ppm has been present for a certain time period. The LED indicator
flashes red 4 times every 5.8 seconds.| 4 quick beeps repeating every 5.8 seconds.
Unit detects CO (alarm not initiated).| | A CO concentration level ranging from 30 to 999 ppm has been detected, but for less than the allotted detection period. The LED indicator flashes green once every 60 seconds.| None.| Dangerous CO concentration is detected, but has not reached the alarm status. Potentially dangerous CO conditions exist.
Please search for the CO source first. Open nearby windows and doors, and immediately move to fresh air.
Unit detected smoke and initiated an alarm.| –| The LED indicator flashes green once every second for 5 seconds.| None.| Alarm cancellation: when the smoke concentration level drops below the alarm threshold, the alarm signal will stop. Then, the alarm goes back to the standby mode.
Unit detects CO and initiates an alarm.| –| The LED indicator flashes green once every second for 5 seconds.| None.| Alarm cancellation: when the CO concentration level drops below the alarm threshold, the alarm signal will stop. Then, the alarm goes back to the standby mode.
Test Mode

| | 2 sets of 3 red flashes followed by 2 sets of 4 red flashes.| 2 sets of 3 long beeps followed by 2 sets of 4 quick beeps.| Press the test/silence button.
Silence Mode

| –| Flashes red 3 times every 4 seconds.| None.| The app will send a
silence notification.
| Flashes red 4 times every 5.8 seconds.| None.|
| Flashes yellow once every 60 seconds.| None.| Silence mode during low battery: After 10 hours, the unit will exit silence mode.
| Flashes yellow 3 times every 60 seconds.| None.| Silence mode during the end of cycle: After 22 hours, the unit will exit silence mode.
–| Flashes green 3 times.| None.| Exiting silence mode.
Low Battery| | Flashes yellow once every 60 seconds.| One beep every 60 seconds.| The app will send a low battery
notification.
Fault| | Flashes yellow 2 times every 60 seconds.| 2 beeps every 60 seconds.| The app will send a fault notification.
End of Life| | Flashes yellow 3 times every 60 seconds.| 3 beeps every 60 seconds.| Replace the unit immediately.

Technical Specifications

Power Supply Replaceable 3 V CR123A lithium battery
Operating Life 10 years
Battery Life 1 year
Sensor Type Smoke: Photoelectric

CO: Electrochemical
Safety Standards| UL 217 and UL 2034
CO Sensitivity| 70 ppm: 60-240 minutes
150 ppm: 10-50 minutes
400 ppm:4-15 minutes
Coverage Area| 215-430 sq. ft (20-40 m2)
Operating Temperature| 40-100°F (4.4-37.8°C)
Operating Relative Humidity| 10%-85% RH (non-condensing)
Alarm Loudness| 85 dB at 10 ft (3 m) @ 3.2 ± 0.3 kHz pulsing alarm
Silence Duration| About 9 minutes
App| Tuya Smart/Smart Life (Android and iOS supported)
Wireless Frequency| 2.4 GHz (Incompatible with 5 GHz Wi-Fi network)
Wireless Protocol| IEEE 802.11 b/g/n

NOTES

  1. Battery life s calculated on current ratings i the weekly test mode and standby mode. lf the ‘operation mode changes to an alarming condition, the battery life will be decreased accordingly.
  2. This alarm functions between 40 and 100°F (4.4 and 37.8°C). Prolonged exposure to lower or higher temperatures can reduce battery life and affect device performance. We do not recommend operating the device outside of this temperature range.

Maintenance

General Maintenance
Follow the steps listed below for optimum long-term performance:

  1. Test the device once a week by pressing the test/silence button, ensuring the device functions properly. Note that this only tests the electronics in your alarm rather than smoke/CO,
  2. Clean the alarm every three months. Remove the device from the ceiling or wall and clean the cover and vents with a soft, damp cloth. Be sure to properly reinstall the device after cleaning.
  3. Do not clean the device with detergents or solvents, or spray air fresheners or hair spray near the device, as these may lead to a malfunction.
  4. Do not paint the device, as it will seal the vents and reduce the sensitivity of the sensors.
  5. Do not tamper with this device, as this may lead to electrical shock or malfunction.
  6. Do not disassemble the device to clean the interior. Doing so will void your warranty.

Weekly Test
Test the alarm once a week, when you turn on the device for the first time, and every time you replace the battery or reconfigure the device.
To test the alarm, press the test/silence button – the device will emit 2 sets of 3 long beeps followed by 2 sets of 4 quick beeps. If you hold down the test/silence button for longer than 3 seconds, the combination smoke and carbon monoxide alarm will re-enter the pairing process, and all previous settings will be erased.
Note that this will only test the electronics. If the device fails to deliver an audible test signal, please refer to the Troubleshooting section.

Battery Replacement

  1. Remove the alarm from the mounting bracket by twisting counterclockwise.
  2. Take out the old battery and install a new one, making sure to match the battery’s polarities.
  3. Test the alarm by pressing the test/silence button on the device.
  4.  Attach the alarm onto the mounting bracket by twisting clockwise until it is firmly secured.

NOTE: When you replace the battery, the LED indicator on the alarm will flash red once and green for a few seconds, indicating the alarm is back online. If the LED indicator flashes green for longer than 2 minutes, you will need to re-add the alarm to the system by repeating the steps above.

Troubleshooting

DESCRIPTION PROBLEM SOLUTION
The device does not alarm during a test. Dead batteries or improper
operation. • Check the battery.

• Firmly press the test/silence button.
False alarms are triggered when cooking or taking a shower.| Improper installation location or maintenance,| • Avoid placing alarms near cooking appliances, dusty areas, showers, or any areas where the temperature drops below 40°F (4.4°C) or rises above 100°F (37.8°C). See the “Installation Positioning” section.
• Clean the alarm every three months to avoid unwanted alarms caused by dust and dirt. See the “Maintenances section.
The LED indicator flashes yellow once every 60 seconds with 1 beep.| Low battery warning.| Replace the battery immediately.
The LED indicator flashes yellow every 40 seconds with 2 beeps.| Malfunction.| Clean your alarm to see if it is functioning properly. If not, replace the device immediately.
The LED indicator flashes green during a test, or the app shows the alarm as being “Offline”.| Wi-Fi disconnection.| Make sure the alarm is installed within the router range and that there are no obstructions between the device and the router.

Environmental Protection
**** Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with Local Authority or retailer for recycling advice.

Manufacturer and Service Information
Smartie International LLC
/Address: 160 Greentree Dr, Dover, DE 19904, USA
Email: support@aegislinkco.uk

Smartie International LLC
Email: support@aegislink.co.uk

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals