AEGISLINK SC-RF200 Interlinked Smoke Carbon Monoxide Detector Combo User Manual

June 14, 2024
Aegislink

AEGISLINK SC-RF200 Interlinked Smoke Carbon Monoxide Detector Combo User Manual
Interlinked Smoke Carbon Monoxide Detector Combo

Introduction

“This AEGISLINK combination smoke and carbon monoxide alarm conforms with UL 217 and UL 2034 Standards and is designed to detect both smoke and carbon monoxide.

Package Contents

  • 1 x Alarm Unit
  • 1 x Mounting Bracket
  • 2 x Screws
  • 2 x Anchor Plugs
  • 1 x Pin
  • 1 x User Manual

Product Profile
Product Profile

Basic Safety Information

IMPORTANT

  1. DANGERS, WARNINGS, AND CAUTIONS ALERT YOU TO IMPORTANT OPERATING INSTRUCTIONS OR TO POTENTIALLY HAZARDOUS SITUATIONS. PAY SPECIAL ATTENTION TO THESE SITUATIONS,
  2. THIS COMBINATION SMOKE & CARBON MONOXIDE ALARM IS ONLY APPROVED FOR HOME USE.
  3. THIS CARBON MONOXIDE ALARM IS DESIGNED TO DETECT CARBON MONOXIDE FROM ANY SOURCE OF COMBUSTION,
  4. CONSTANT EXPOSURES TO HIGH OR LOW HUMIDITY MAY REDUCE BATTERY LIFE.
  5. SMOKE ALARMS ARE NOT TO BE USED WITH DETECTOR GUARDS UNLESS THE COMBINATION HAS BEEN EVALUATED AND FOUND SUITABLE FOR THAT PURPOSE.

CAUTION
THIS SMOKE & CARBON MONOXIDE ALARM HAS TWO SEPARATE ALARMS WHICH WORK INDEPENDENTLY. THE CARBON MONOXIDE ALARM IS NOT DESIGNED TO DETECT FIRE OR ANY OTHER GAS. ITWILL ONLY INDICATE THE PRESENCE OF CARBON MONOXIDE GAS AT THE SENSOR. CARBON MONOXIDE GAS MAY BE PRESENT IN OTHER AREAS. THE SMOKE ALARM WILL ONLY INDICATE THE PRESENCE OF SMOKE THAT REACHES THE SENSOR. THE SMOKE ALARM IS NOT DESIGNED TO DETECT GAS, HEAT OR FLAMES,

WARNING

  1. NEVER IGNORE ANY ALARM. FAILURE TO RESPOND CAN RESULT IN SERIOUS INJURY OR DEATH,
  2. THE SILENCE FEATURE IS ONLY FORYOUR CONVENIENCE AND WILL NOT CORRECT A PROBLEM, ALWAYS CHECK YOUR HOME FOR A POTENTIAL PROBLEM AFTER ANY ALARM. FAILURE TO DO SO CAN RESULT IN INJURY OR DEATH,
  3. TESTTHIS SMOKE/CO ALARM ONCE AWEEK_IF THE ALARM EVER FAILS TOTEST ‘CORRECTLY, REPLACE IT IMMEDIATELY! IF THE ALARM CANNOT WORK PROPERLY, T WILL NOT ALERT YOU TO A PROBLEM.
  4. THIS PRODUCT IS INTENDED FOR USE IN ORDINARY INDOOR LOCATIONS OF FAMILY LIVING UNITS. IT IS NOT DESIGNED TO MEASURE CO LEVELS IN COMPLIANCE WITH OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) COMMERCIAL OR INDUSTRIAL STANDARDS. INDIVIDUALS WITH MEDICAL CONDITIONS THAT MAY MAKE THEM MORE SENSITIVE TO CARBON MONOXIDE MAY CONSIDER USING WARNING DEVICES WHICH PROVIDE AUDIBLE AND VISUAL SIGNALS FOR CARBON MONOXIDE CONCENTRATIONS UNDER 30 PPM. FOR ADDITIONAL INFORMATION ON CARBON MONOXIDE AND YOUR MEDICAL CONDITION CONTACT YOUR PHYSICIAN,
  5. THE REPLACEMENT DATE THAT APPEARS ON THE DEVICE IS THE DATE BEYOND WHICH THE DEVICE MAY NO LONGER DETECT CARBON MONOXIDE ACCURATELY AND SHOULD BE IMMEDIATELY REPLACED.
  6. THIS DEVICE IS DESIGNED TO PROTECT INDIVIDUALS FROM THE ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE. IT MAY NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS. I IN DOUBT, CONSULT A MEDICAL PRACTITIONER.

How to Set Up and Interconnect Wireless Alarms

All AEGISLINK wireless interlinked alarms contain a built-in RF module that enables you to wirelessly connect 2 or more interlinked alarms and create an interlinked network, When one unit s triggered, al interconnected alarms willsound. The AEGISLINK series contain ‘wireless interlinked smoke alarms, wireless interlinked carbon monoxide alarms, and wireless interlinked combination smoke and carbon monoxide alarms. This model is designed to be wirelessly interlinked with other AEGISLINK alarms, but is not designed to ‘communicate with wireless interlinked alarms from other manufacturers,

The wireless interlinked alarms in one multi-pack have already been interconnected to each other, so the alarms i each multi-pack have their own independent interlinked network. If you have more than one multi-pack, you will need to connect them all to the same network, but you do not have to disconnect each alarm individually. Choose one multi-pack as your base network and connect the other multi-packs to it.

NOTE! The following instructions regarding wireless interconnection are applicable to AEGISLINK wireless interlinked alarms only.

How to Interconnect

  1. Make sure you only work with 2 units at a time, and that they are both activated to ensure successful connection.
    NOTE: To activate your alarm, remove the back cover from the device and pull out the battery insulating film from the battery compartment. To learn how to turn on different models of wireless interlinked alarms, please refer to their specific user ‘manuals for more details.

  2. Press the pinhole paifing button on the back of one of the 2 units using the included pin. It will beep once and the LED willflash red slowly,indicating it has entered paiing mode and is waiting for a new unit to be added. Hold down the pinhole pairing button on the other unit until it beeps once and its LED flashes red rapidly as it i searching for a unit 1o connect to.

  3. After the search s successful and an interconnected group s created, both units will beep once and automatically exit the interconnection mode. At this point, both units will only flash once every 60 seconds, indicating they are in normal standby mode.

  4. 1f you want to connect a third alarm to this group, firs activate the new device according to1ts operating instructions. Press the pinhole pairing button on either of the 2 previously interconnected units using the included pin, it will beep once and the LED will flash red slowly,indicating it has entered pairing mode and is walting for a new unit to be added. Hold down the pinhole pairing button on the new unit until it beeps once and its LED
    flashes red rapidly as it searches for a network to which it can connect. After the third unit successfully joins the interconnected network, both units will beep once and automatically exit the interconnection mod.

  5. 1f you want to connect more units Simply repeat step 4. Up to 24 alarms can be interconnected this way. To ensure that all alarms enter the same interlinked network, make sure you only work with 2 units at a time—one unit enters the paiting mode and the other unit enters the searching  mode.

  6. Test the alarms according to the steps in the section Alarm Test”

Press the pinhole pairing button

Hold down the pinhole pairing button

Press the pinhole pairing button
Hold down the pinhole Pairing button

Hold down pinhole paifing button the test/silence button

NOTES

  1. The alarm will enter the searching mode or the pairing mode for 60 seconds with the LED flashing red. After 60 seconds, repeat step 2 to connect the alarms. If needed, press the pinhole pairing button once while the alarm s in the searching mode or the pairing mode, and the LED will stop flashing red and the alarm will quit the pairing ‘mode to enter normal status.
  2. Test al wireless alarms to ensure they are interconnected before installation.
  3. Amaximum of 24 wireless alarms can be interconnected on the same network.
  4. The model can only be interconnected with other AEGISLINK wireless interlinked alarms.

How to Disconnect

Press the pinhole pairing button 4 times using the pin and the unit will beep once. Then, hold down the pairing button until the unit beeps once more to disconnect. After disconnecting, it can be reconnected to the same network, or added to a new network.

Alarm Test

Be sure 10 test your alarms when you tur them on for the first time, or when the group configuration has changed. In addition to the weekly tests you should perform, itis recommended to test the alarm after returning from a long trip or vacation.

If your AEGISLINK SC-RF200/SC-RF220 is interconnected to other wireless alarms, we recommend that every individual alarm is tested during the weekly test.

| Test a Single Alarm| Test All Interconnected Alarms
---|---|---
Action| Press the test/silence button.| Hold down the test/silence button.
Indication|

  • The alarm will emit 2 sets of 3 long beeps followed by 2 sets of 4 quick beeps
  • The LED will flash red during the aud ible signal.
  • After testing, the alarm will automatically enter stand by mode.

|

  • The initiating unit will beep continuouslywith the LED flashing red.·
  • Other interconnected units in the networkwill receive the signal after 5 seconds, thenthey will beep continuously with the LEDflashing red and green successively. Releasethe test/silence button and all the units willstop testing.·
  • The testing of the units should be completedwithin 3 minutes.·
  • After testing, the units will automatically enter standby mode.

NOTE: The test function accurately tests the alarmscircuits without the need to test with smoke and CO. I your alarm fails to give an audible test signal, please immediately refer to the troubleshooting guide at the end of this manual. Never use an open flame to test this device.

Installation Positioning

Installation Positioning 

  • SMOKE ALARMS
  • CARBON MONOXIDE ALARMS
  • SMOKE & CARBON MONOXIDE ALARMS
  • FIRE EXTINGUISHERS

NOTE: If an alarm is installed in a kitchen, ensure it has an accessible silence button, and install itas far away from the stove and sink as possible to avoid false alarms.

  1. Prioritize the installation of an alarm in the bedroom and walkways, and make sure you can hear the alarm from all sleeping areas. In a home with several bedrooms, install an alarm in every bedroom, If you install only one smoke alarm in your home, install the alarm near to all bedrooms where possible, and not in a basement or furnace room.
  2. Install an alarm above the stairway and on every floor of the house.
  3. Smoke, heat and anything burning will spread horizontally after rising to the ceiling, so install the alarm in the middle of the ceiling where possible. Ensure that the alarm is installed at the minimum distance away from corner.
  4. If an alarm cannot be installed in the middle of a ceiling, install it at a distance of 20 in (50 cm) away from the corners of the room.
  5. If an alarm is installed onto a wall, a distance of 4-12 in (10-30 cm) should be kept below the ceiling.
  6. If the length of a room or hall is beyond 30 ft (900 cm), several alarms should be installed in the same room.
  7. When the wall or ceiling is angled, the alarm needs to be installed within 3 ft (90 cm) of the highest wall or ceiling point (measured horizontally) in the room,
  8. In multi-level houses or apartments, install at least one wireless alarm on each level and keep them installed in a straight vertical line (see diagram) with as few obstacles between each of the interconnected alarms as possible to ensure optimal signal transmission,
    Dimension

Locations to Avoid:

  1. Near large metal surfaces and/or bundles of wire.
  2. Near fluorescent lights, amateur radios, electrical equipment, or other devices that may transmit an RF signal, as electronic ‘noise” may cause nuisance alarms.

WARNING

  1. THIS ALARM SHOULD BE INSTALLED BY A COMPETENT PERSON.
  2. ALARMS SHOULD NOT BE USED AS A SUBSTITUTE FOR PROPER INSTALLATION, USE AND MAINTENANCE OF FUEL BURNING APPLIANCES INCLUDING APPROPRIATE VENTILATION AND EXHAUST SYSTEMS.
  3. TO PREVENT INJURY, THIS DEVICE SHOULD BE SECURELY ATTACHED TO THE CEILING OR WALL IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS.
  4. BATTERIES SHOULD NOT BE EXPOSED TO EXCESSIVE HEAT SUCH AS DIRECT SUNLIGHT, FIRE, ETC

Installation Method

NOTE : Before installation, it is recommended to test the interconnected alarms in the rooms where you intend to install them to ensure that they are within transmission range and that nothing will interfere with their communication.

  1. Use the mounting bracket to mark the screw holes on the ceiling or the wall.

  2. Drill holes at the 2 marks using an appropriately-sized drill bit. Insert the anchor plugs and screw the mounting bracket using the screws provided.

  3. Attach the alarm to the mounting bracket and turn clockwise to lock the alarm.

  4. Test the alarm according to the steps in the section “Alarm Test”.

Battery Replacement

  1. To replace the battery, detach the alarm from the mounting bracket by twisting counterclockwise
  2. Pull the battery removal tab to remove the battery, and then install a new battery. matching the correct polarity markings.
  3. Test the alarm, and then mount the alarm onto the mounting bracket by  twistingclockwise to lock the alarm,
    Battery Replacement

LCD Indicator and Audible Alarm

| Mode| LCD Display| LED Indicator| Audible Alarm| Remarks
---|---|---|---|---|---
| Powering On| | Runs through 8 cycles (yellow/green /red) in sequence.| 1 quick beep.| Make sure the battery is installed correctly and the device is turned on.
| Standby Mode| | Flashes green once every 60 seconds| None.| None.
Alarm Mode| Unit detects CO and initiates an alarm.| | Flashes red 3 times every 4 seconds| 3 long beeps every 4 seconds| Dangerous smoke concentration is detected. Open nearby windows and doors, and immediately move to fresh air.
| Unit detects CO and initiates an alarm.| | A CO concentration ranging from 30 to 999 ppm has been present for a certain time period. The LED indicator flashes red 4 times every 5.8 seconds.| 4 quick beeps repeating every 5.8 seconds.| Dangerous CO concentration is detected, and has reached the alarm status. Open nearby windows and doors, and immediately move to fresh air.
| All other interconnected units in the network| | The LED flashes red and green 3 times sequentially every 4 seconds| 3 long beeps every 4 seconds.| Dangerous smoke concentration is detected by the Initiating unit in the network. Please find the initiating unit and take action.
| | The LED flashes red 4 times, then the LED flashes green once every 5.8 seconds.| 4 quick beeps repeating every 5.8 seconds.| Dangerous CO concentration is detected by the initiating unit, and has reached the alarm status.Please find the Initiating unit and take action.
| Unit detectsCO (alarm notinitiatedi.| | A CO concentration level ranging from 30 to 999 ppm has been detected, but for less than the allotted detection period. The LED Indicator flashes green once every 60 seconds.| None| Dangerous CO concentration is detected, but has not reached the alarm status. Potentially dangerous CO conditions existPlease search for the CO source first. Open nearby windows and doors, and immediately move to fresh air.
| Unit detected smoke and initiated an alarm.| | The LED indicator flashes green once every second for 5 seconds.| None.| Alarm cancellation: when the smoke concentration level drops below the alarm threshold, the alarm signal will stop. Then, the alarm goes back to the standby mode.
| Unit detected CO and initiated an alarm.| | The LED indicator flashes green once every second for 5 seconds.| None| Alarm cancellation: when the CO concentration level drops below the alarm threshold, the alarm signal will stop. Then, the alarm goes back to the standby mode.
| Test Mode| Test a single unit| | 2 sets of 3 red flashes followed by 2 sets of 4 red flashes| 2 sets of 3 long beeps followed by 2 sets of 4 quick beeps.| Press the test/silence button.
| Test allinterconnected units.| | The LED indicator flashes red rapidly| Continuous beeping until you release the test/silence button| Initiating alarm.Hold down the test/silence button on one unit in the network
| | | The LED flashes red and green sequentially,| Other interconnected alarms in the network
| Silence Mode| | Flashes red 3 times every 4 seconds.| None .| Smoke silence mode: After 9 minutes, the unit will exit silence mode.
| | Flashes red 4 times every 5.8 seconds| None| CO silence mode: After 9 minutes, the unit will exit silence mode
| | Flashes yellow once every 60  seconds.| None| Silence mode during low battery: After 10 hours, the unit will exit silence mode
| | Flashes yellow 3 times every 60 seconds.| None.| Silence mode during the end of cycle: After 22 hours, the unit will exit silence mode
| | Flashes green 3 times.| None| Exiting silence mode.
| Low Battery| | Flashes yellow once every 60 seconds| One beep every 60 seconds.| Replace the unit immediately.
| Fault| | Flashes yellow 2 times every 60 seconds.| beeps every 60 seconds.| Please clean your alarm and see if it is working normally. If “Err continues to display, the unit has malfunctioned and must be replaced immediately.
| End of Life| | Flashes yellow 3 times every 60 seconds.| 3 beeps every 60 seconds.| Replace the unit immediately.

Alarm Mode

The AEGISLINK wireless interlinked alarms can be interconnected such that any unit that senses danger will cause all other units in the interconnected network to alarm.

  1. If the Initiating Unit Is Triggered by Smoke:
    When one smoke alarm is triggered in the interconnected network, the unit will beep 3 times, paired with the LED that flashes red every 4 seconds. Any other interlinked units will follow suit-they will beep 3 times every 4 seconds, paired with the LED flashing red and green in succession.

  2. If the Initiating Unit Is Triggered by CO:
    When one CO alarm is triggered in the interconnected network, the unit will beep 4 times every 5.8 seconds, paired with the LED flashing red. Any other interlinked units in the network will follow suit-they will beep 4 times every 5.8 seconds, paired with the LED that flashes red 4 times first, followed by the LED that flashes green once with every beep. When the CO concentration level drops below the alarm threshold, the alarm will cease

NOTES

  • When one unit is triggered, other interconnected units will sound. If the smoke alarm and CO alarm are triggered in the network at the same time, the alarm signal of the smoke alarm will take priority over that of the CO alarm.
  • This alarm has a relay function that extends the wireless interconnected network for wide detection coverage

Silence Mode

Smoke Silence Mode: Press the test button during an alarm to have the unit enter silence mode for 9 minutes. If the smoke concentration has reached an alarm level, after the silence time has expired, this unit will continue to alarm until the smoke concentration decreases to a safe, low level. Otherwise, the alarm will enter the normal mode after 9 minutes.

CO Silence Mode: Press the test button during an alarm to have the unit enter silence mode. If the CO density still exceeds the alarm threshold, the unit will re-enter alarm state. Otherwise, the unit will exit the silence mode after 9 minutes and resume normal operation.

Note

  • You can silence all interconnected units by pressing the test/silence button on one of the units. If one unit is still alarming, it is the initiating unit (the unit that detected danger); to silence all interlinked units, you must also press the test/silence button on the initiating unit.
  • While interconnected, the initiating unit cannot be triggered again during the 9-minute silence duration. However, all other interconnected units can be triggered again if they detect danger during the silence mode.

CO Alarm Levels

his combination smoke & carbon monoxide alarm is programmed to sound an alarm at the following CO concentrations within the time periods listed

70 ppm for 60-240 minutes,
150 ppm for 10-50 minutes,
and 400 ppm for 4-15 minutes. 

CO Concentration and Symptoms
The table below shows the effects of different levels of CO poisoning on the body:

Parts per Million (PPM) Effects on Adults
100 Slight headache, nausea, fatigue (flu-like symptoms).
200 Dizziness and headache within 2-3 hours.
400 Nausea, frontal headache, drowsiness, confusion and rapid heart rate.

Risk to life after over 3 hours of exposure.
800| Severe headaches, convulsions, vital organ failures. Death possible within 2-3 hours.

WARNING THIS DEVICE IS DESIGNED TO PROTECT INDIVIDUALS FROM ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE. T MAY NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS. IF IN DOUBT, CONSULT A MEDICAL PRACTITIONER.

Technical Specifications

Power Supply. Replaceable 3/ CR123A lthium battery
Operating Life 10years
Battery Life 5 years
Sensor Type Smoke: Photoelectric

CO: Electrochemical
Safety Standards| UL 217 and UL 2034
CO sensitivity| 70 ppm: 60-240 minutes
150 ppm: 10-50 minutes
400 ppm: 4-15 minutes.
Operating Temperature| 40-100°F (44-378°C)
Operating Relative Humidity| 10%-85% RH (non-condensing)
Alarm Loudness| ≥ 85 dB at 10 ft (3 m) @ 3.2 ± 0.3 kHz pulsing alarm
Silence Duration| About 9 minutes
Operating Frequency| 915 MHz
Maximum Number of Interconnected Units| 24 wireless units (only compatible with AEGISLINK wireless alarms)
Transmission Range| Over 820 ft (250 m) in open air

NOTES

  • Battery life is calculated on the current ratings in the standby mode with weekly testings. If its
    operation mode changes to an alarming condition, the battery life will be decreased accordingly.

  • The alarm functions between 40 and 100°F (4.4 and 37.8°C). Prolonged exposure to temperatures outside of this range can reduce battery life and affect accuracy. We do not recommend operating the device outside of this range.

Maintenance

To keep your smoke/CO alarm in good working order, follow these simple steps:

  1. Verify the unit’s alarm sound and indicator are working properly by testing the unit once a week
  2. As a minimum your alarm should be cleaned once every 3 months: Remove the unit from the ceiling and clean the alarm cover and vents with your vacuum cleaner fitted with the soft brush attachment to remove dust and dirt.
  3. Never use detergents or other solvents to clean the unit.
  4. Avoid spraying air fresheners, hair spray or other aerosols near the alarm..
  5. Do not paint the unit. Paint will seal the vents and interfere with the sensor’s ability to detect fire or CO
  6. Never attempt to disassemble the unit or clean inside. Doing so will void your warranty.
  7. When removed, place the alarm back in its proper location as soon as possible, to assure continuous protection from fire.
  8. When household cleaning supplies or similar contaminants are used, the area should be ventilated.

Troubleshooting

PROBLEM SOLUTION
Your combination smoke and carbon monoxide does not sound during testing
  • Please ensure the battery is properly installed in the alarm
  • .Make sure you push the test/silence button firmly.
  • Check the installation positioning. The wireless signal might be blocked or out of range.

False alarms tiggered intermittently or when residents are cooking ,taking showers, elc|

  • Check the location of your alarm (see “Installation Positioning”).
  • Clean the alarm (see “Maintenance”).

LED flashes yellow and the a| The battery islow. Replace the battery immediately.
LED flashes yellow 2 times every 60 seconds with 2 beeps.| The alarm is malfunctioning. Please clean your alarm or push the test/hush button once to attempt to reset the unit I the problem still occurs,replace the alarm immediately.
LED flashes yellow 3 times every 60 seconds with 3 beeps.| LED flashes yellow 3 times every 60 seconds with 3 beeps.
LED flashes yellow 3 times every 60 seconds with 3 beeps.| The maximu ifetime (10 years) is reached. Push the testhush button once to slence for 22 hours Replace the alarm immediately.

Environmental Protection
Waste electrical products should not be disposed of with household waste. Please recycle ‘where facilities exist. Check with Local Authority or retaler for recycling advice.

Manufacturer and Service Information

Smartie International LLC
Address: 160 Greentree Dr, Dover, DE 19904, USA
Email:support@aegislink.co.uk

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals