COMMSCOPE TC-96353-IP EPX Splice Panel User Guide

June 15, 2024
CommScope

COMMSCOPE Logo TC-96353-IP · Rev A · January 2023
Quick Start

EPX SPLICE PANEL

Product Description

The EPX Splice panel
(760254513 | EPX-3U-SPL-ENC) is a 3RU, 19-inch rack-mount panel that holds and protects splices when mating two blunt cables. Each panel accommodates up to 336 single fibers in 7 AGL splice trays (760241378 | AGL Splice-48). Each splice trays holds 48 fibers, each providing stackable, 48-fiber capacity per tray for a total of 336 single fiber splices. Accessories listed at right must be ordered separately.

PARTS LIST

DESCRIPTION QUANTITY
EPX SPLICE PANEL 1
RACK SCREW 4

TOOLS REQUIRED

DESCRIPTION QUANTITY
PHILLIPS #2 SCREWDRIVER 1
SNIPS 1

ACCESSORIES

CABLE CLAMP
MESH TUBING
AGL SPLICE TRAY (760241378/AGL-Splice-48)

  1. Install Panel as follows: (a) mount panel on frame; (b) remove 1x transportation screw from panel (it holds the ALERT label); (c) mount input and output cables on frame at adjacent location using cable clamp of customer choice (order separately;work with your Commscope technical resource or the Technical Assistance Center (TAC) for breakout kit options); see Step 2 breakout diagram. COMMSCOPE TC 96353 IP EPX Splice Panel 
  2. Break Out Input and Output Cables . Break out the cables per the diagram below, fitting the sub-units with mesh tubing as indicated. Route each sub-unit “bundle” into either back corner of the panel as shown in Step 3. Secure the mesh tubing with tie wraps and felt tape in the location shown.COMMSCOPE TC 96353 IP EPX Splice Panel - Cables
  3. Install Cable as follows: (a) remove back cover (unscrew knob to release it); (b) route cable bundles to the rear of the panel; secure on cable mount using cable tie and felt tape; (c) bring bundles forward to the panel front; (d) unpack splice tray and identify components; (e) route bundles to splice tray for splicing on nearby table; (f) splice as shown; see Note below.COMMSCOPE TC 96353 IP EPX Splice Panel - Cables
  4. Press on the red latch (a) to release the work tray and pull it out toward the front of the panel as shown, until the red latch click into position at (b).COMMSCOPE TC 96353 IP EPX Splice Panel - Install Cable 1
  5. After loading a splice tray per the instructions in the splice tray kit, wind the splice tray and attached bundles back into the panel, looping the bundles within the panel as shown.COMMSCOPE TC 96353 IP EPX Splice Panel - After loading
  6. Install the first splice tray into the panel as follows:COMMSCOPE TC 96353 IP EPX Splice Panel - After loading 1
  7. Install additional trays as follows:COMMSCOPE TC 96353 IP EPX Splice Panel - additional trays
  8. Release red latch and slide work tray with splice trays back into panel. Dress cables in an orderly manner. Close panel doors.

COMMSCOPE Logo PRODUCT INFORMATION AND TECHNICAL SUPPORT
http://www.commscope.com\SupportCenter
PRODUCT PATENTShttps://www.cs-pat.com
28004-A
© 2023, CommScope, Inc. All Rights Reserved.

Documents / Resources

| COMMSCOPE TC-96353-IP EPX Splice Panel [pdf] User Guide
EPX-3U-SPL-ENC, 760254513, TC-96353-IP, TC-96353-IP EPX Splice Panel, EPX Splice Panel, Splice Panel, Panel
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CommScope User Manuals

Related Manuals