COMMSCOPE NVX-GRND-CC-NN-C15 NOVUX Fiber Optic System Grounding kit Instruction Manual
- June 15, 2024
- CommScope
Table of Contents
Installation Instructions
TC-1539-IP Rev. B, June 2023
NOVUX™ Fiber Optic System
NVX-GRND-CC-NN-C15: Grounding kit for CC 150/200
Applicable for CC 150/200
Compatibility
This grounding kit is compatible to use with the following cable retention modules:
Cable retention module| Cable diameter range (mm)| Cable diameter range
(Inches)
---|---|---
NVX-CR-SA-LA-NN: Cable retention – Large| 18-Jun| 0.24- 0.71
Tools
Note: Wear protective safety gloves when handling the metal shield.
Kit contents
N° | Description | Qty |
---|---|---|
1 | Grounding bar | 1 |
2 | Grounding cable | 4 |
3 | Screws | 4 |
Prepare feeder cable
-
If the diameter is smaller than 9 mm / 0.35 Inches or if the jacket is a thin jacket, add 5 wraps of silicon tape (width 2,5 cm / 1 Inch).
-
Stretch the tape minimum 50% while wrapping the tape around the cable. Make sure the tape is wrapped where the hose clamp will be positioned.
-
Prepare the cable per standard practice. Leave 2,5 cm / 1 Inch of the shield.
-
Carefully peel the shield open with a pair of pliers until maximum 1/2 of the circumference stays in place.
-
Cut of the excess shield.
-
Bend the remaining part of the shield downwards.
Note: Make sure to not crack the shield. -
Remove the plastic coating on the shield with a cutter knife.
-
Bend the shield further downwards until it touches the cable jacket or the silicone tape.
Install the armored cable on the bracket
- Position the cable on the bracket as shown and install the strength member (rigid strength member or aramid yarn) per practice as explained in the basic installation instruction or TC-1538-IP: Cable retention large.
- Open the hose clamp and tighten the hose clamp with the hex 7 socket wrench.
- Push the grounding wire with the clip over the stud on the metal bracket. A pair of pliers can be used to push it properly over the stud.
Install the grounding bar and bond the cables
-
Install the bracket into the organizer at the rear side as explained in the basic installation instructions.
-
Install the grounding bar in the middle of the organizer (rear side), between the entrance ports.
-
The grounding bar snaps into the organizer by sliding it downwards.
-
Bond the armored cable to the grounding bar by connecting the grounding wire to the grounding bar with one of the screws.
-
Example of 4 cables bond to the grounding bar.
Earthing
-
A grounding wire should be attached to the grounding bar. The hole at the end of the grounding bar can be used.
Note: This grounding wire is not included in the kit content. -
Connect the grounding wire to an object outside the closure per local practice.
© 2023 CommScope, Inc. All Rights Reserved
All trademarks identified by ® are registered trademarks in the US and may be
registered in other countries. All third party product names, trademarks and
registered trademarks are property of their respective owners. This product
may be covered by one or more U.S. patents or their foreign equivalents. For
patents, see www.cs-pat.com. This document is not
intended to modify or supplement any specifications or warranties relating to
CommScope products or
services. Visit our website or contact your local CommScope® representative
for more information. www.commscope.com.
For technical assistance, customer service, or to report any missing/damaged
parts, visit us at: http://www.commscope.com/SupportCenter.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>