COMMSCOPE TC-1472-IP NOVUX Fiber Optic System Port Valve Instruction Manual
- June 15, 2024
- CommScope
Table of Contents
COMMSCOPE TC-1472-IP NOVUX Fiber Optic System Port Valve
Kit contents
N° | Description | Qty |
---|---|---|
1 | Valve | 1 |
2 | Carrier | 1 |
3 | Metal clip | 1 |
Valve preparation with metal clip
-
Align the valve with the rib on the carrier.
-
Mount the clip on the valve – carrier assembly. The two slots of the metal clip should be positioned in the two tabs on the carrier, then turn the clip towards the valve.
-
Push until the two snap hooks snap in the slots of the metal clip. Pliers are allowed to close the clip properly.
All trademarks identified by ® are registered trademarks in the US and may be registered in other countries. All third party product names, trademarks and registered trademarks are property of their respective owners. This product may be covered by one or more U.S. patents or their foreign equivalents. For patents, see www.cs-pat.com. This document is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. Visit our website or contact your local CommScope® representative for more information. www.commscope.com. For technical assistance, customer service, or to report any missing/damaged parts, visit us at: http://www.commscope.com/SupportCenter.
Install valve
To secure the valve to the organizer, the three hooks on the rear side of the carrier should slide into the three slots on the interface plate on the organizer. The top left slot has a locking lip to keep the valve – carrier assembly in place.
- Slide the carrier with the valve secured into the slots of the organizer. Push the locking lip in the first slot backwards.
Note: For CC150/ CC200 don’t use the two ports adjacent to the front latch.
-
Slide the carrier downwards.
-
The locking lip returns into original position and the carrier is correctly seated. A clicking sound is observed.
Testing the closure seal
The closure can be tested up to 20 kPa / 3 psi.
Note: After flash testing, release the pressure from the closure through the valve.
Remove carrier
-
Position a fiber guidance pen in the little cavity in the locking lip of the first slot and push the locking lip backwards. When the lock is released, lift the carrier up.
-
Move the carrier with cable attached forward.