Product Information
The product is the CFR5CCT luminaire. It is an energy-efficient light source that falls under energy efficiency class C according to Regulation (EU) No. 2019/2015 and (UK) 2021 No. 1095. The luminaire contains a non-replaceable light source and a non-replaceable control gear. It operates on 230V at 50Hz.
Usage Instructions
- Before installation, read the instructions carefully and keep them for future reference and maintenance.
- If using the luminaire with an external PIR or sensor, ensure compatibility with LED luminaires by confirming with the sensor manufacturer.
- Avoid installing the luminaire near joists, gas/water pipes, or electrical cables for safety reasons.
- For loop-in/loop-out wiring, you can insert two cables into the push-fit terminal block.
- Disconnect the luminaire from the circuit before subjecting it to high voltage or insulation resistance testing to prevent irreparable damage.
- Clean the luminaire with a soft dry cloth only. Do not use aggressive cleaning products or solvents that may damage the product.
- The luminaire is dimmable using trailing-edge dimmers. Check compatibility before installation.
- When the luminaire reaches the end of its life, dismantle it following the instructions provided on the website.
- Correctly dispose of the luminaire by recycling it. Check with local authorities for recycling facilities.
Warranty
The product is supplied by ML Accessories Ltd, located at Unit E Chiltern Park, Boscombe Road, Dunstable LU5 4LT, UK. The authorized representative for the European Union is SLV Lighting Group. For warranty inquiries, please contact the respective suppliers.
GENERAL INSTRUCTIONS
These instructions should be read carefully and retained after installation by the end user for future reference and maintenance. These instructions should be used to aid installation of the following product: CFR5CCT
SAFETY
- This product must be installed by the latest edition of the IEE Wiring Regulations (BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
- Please isolate mains prior to installation or maintenance
- Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the circuit cable, fuse or circuit breaker
- Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
- If used under insulation, the insulation should be laid unbroken over the luminaire (not packed around it). Only mineral wool style insulation may be used
- This product is for indoor use only
- This product is Class II double insulated
- This product is IP65 rated (IP20 from above)
INSTALLATION
Note – If this luminaire is being used in conjunction with an external PIR or sensor, please confirm with the manufacturer of the sensors that they are compatible with LED luminaires.
- Provide power to the required point of installation
- Cut a suitable hole in the mounting surface as per the cut-out details (see Fig. 1) ensuring not to infringe with any joists, gas/water pipes or electrical cables
- Connect the luminaire to the mains supply ensuring the correct polarity is observed (see Fig. 2): L – Live (brown), E – Earth (green/yellow), N – Neutral (blue). The earth terminal is non-functional and only provided for convenience. Two cables can be inserted into the push-fit terminal block in order to achieve loop-in/loop-out wiring
- Select the required colour temperature via the three-position switch on the rear of the luminaire
- Lift both spring clips on the sides of the fitting and push into the ceiling ensuring the terminal block enclosure is not resting against the luminaire
- Switch on and check for correct operation
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance testing. Irreparable damage will occur if this instruction is not followed.
GENERAL
- This product contains a light source of energy efficiency class C to Regulation (EU) No. 2019/2015 and (UK) 2021 No. 1095.
- This product contains a non-replaceable light source and a non-replaceable control gear
- Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents that may damage the product.
- This product is dimmable using trailing-edge dimmers, please check compatibility before installation.
- This product should be dismantled for disposal when it reaches the end of its life. Please see the website for dismantling instructions.
- This product should be recycled correctly when it reaches the end of its life. Check local authorities for where facilities exist.
FEATURES
WARRANTY
This product has a warranty of 3 years from date of purchase. Failure to install this product by the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch code will invalidate the warranty. If this product should fail within its warranty period, it should be returned to the place of purchase for a free of charge replacement. ML Accessories does not accept responsibility for any installation costs associated with the replacement product. Your statutory rights are not affected. ML Accessories reserve the right to alter product specification without prior notice
SUPPLIED BY:
(UK) MANUFACTURER
ML ACCESSORIES LTD, UNIT E CHILTERN PARK, BOSCOMBE ROAD, DUNSTABLE LU5 4LT,
WWW.MLACCESSORIES.CO.UK
(EU) AUTHORISED REPRESENTATIVE SLV LIGHTING GROUP,
DAIMLERSTRASSE 21-23,52531 ÜBACH-PALENBERG, GERMANY
EMAIL: EPREL@GROUP.SLV.COM
MADE IN CHINA
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>