Specifications:

  • Material: Grade 304 stainless steel
  • Protection Level: IP66
  • Control: 8-bit microcontroller
  • LED Lifetime: Over 50,000 hours
  • Operating Temperature: Below 25 Degree Celsius

Product Usage Instructions:

Installation:

  1. Securely mount the unit on the wall using the provided screws
    to prevent accidents.

  2. Open the front cover by releasing the locking clips.

Operation:

  1. Press and hold the ON switch for about 3 seconds to turn on the
    unit.

  2. Observe the LED status indicator to ensure the unit is
    working.

  3. Close and lock the front cover after operation.

Testing:

  1. To initiate a 30-minute test, press the 30 mins button. The
    unit will return to normal operation afterward.

  2. To perform a 60-minute test, press the 60 mins button. The unit
    will resume normal operation post-testing.

  3. To cancel a test, press the OFF button.

Maintenance:

  1. Ensure to turn off the unit using the OFF switch when not in
    use.

  2. Store the unit in temperatures below 25 Degree Celsius.

  3. Charge the battery every 3 months to maintain operational
    life.

FAQ:

Q: How often should I charge the battery?

A: The battery should be charged every 3 months to ensure
operational efficiency and longevity.

Q: What should I do if the battery checker emits an audible

warning?

A: An audible warning indicates extreme battery depletion.
Recharge the battery promptly to avoid complete drainage.

Q: How can I activate testing remotely?

A: Use the infrared remote to remotely activate testing on the
unit.

USER MANUAL
Self-Contained Emergency Light CU – IP66 Series

Remote Testing
5 30 60 secs mins mins

LED AC. LED Charge/Full LED On LED 5 sec LED 30 mins LED 60 mins
Switch On Switch Off
IR receiver

Indicate that the unit is receiving power. Indicate information on battery charging. Indicate the unit is ready for operation. Indicate the unit is performing a 5 second test. Indicate the unit is performing a 30-minute test. Indicate the unit is performing a 60-minute test. Press to turn on the lamp (while the unit is not plugged in). Press to turn off the lamp (while the unit is not plugged in). Infrared signal sensor used to receive signal from the Infrared remote.

Note : All 3 LEDs flash 5sec, 30mins, 60mins at the same time. Displays the battery failure alarm situation.

Status Indicators and Testing Buttons

Remote Testing

Features

1. The hosing is made from Grade 304 stainless steel protected against jets of water and dust tight certified by Electrical and Electronics Institute for IP 66 standard.
2. Controlled by a highly intelligent 8-bit micro controller. 3. Automatically self-test every 30 days and discharges the battery for 30 minutes to
help extend the life of the battery. 4. Testing can be activated remotely using the infrared remote. 5. Using high quality LEDs with a lifetime of over 50,000 hours, providing bright and
constant illimitation throughout its operation. 6. The battery monitoring circuit will give an audible warning when the battery’s charge
is about to be depleted, giving the user time to recharge it before draining completely. This will help to extend the life of the battery.

Installation and Operation
1. Install the unit on the wall by using the screws on the ear to fix the unit firmly to prevent
dropping that will cause accidents to the user or the product. 2. Open the front cover of the unit to turn on the device by releasing both locking clips
and opening the front cover. 3. Press the ON switch (hold about 3 seconds) to turn on the device, both emergency
lamps will illuminate. 4. Notice the LED will show the status as follows.
4.1 “LED ON” indicates that the unit is working. 5. Close the front cover and lock the front cover with both locking clips. (Before closing
the front cover, keep the power cable inside the unit in order to prevent the power cable from pressing on the rubber seal or causing the front cover to not lock tightly, which may cause water and dust to enter the unit.) 6. Plug the unit into a power socket with a 220-240VAC power supply. The unit will remain on for about 5 seconds before turning off. 7. The LED AC will turn on indicating that the unit is receiving power. The LED Charge/Full will be on when the battery is charging and will turn off when the battery is fully charged. 8. When the unit is operational, tests can be performed using the Test button on the unit or remotely using the remote with the following options. – Press the 5 sec button to perform a 5 second test, after which the unit will return
to normal operation. – Press the 30 mins button to perform a 30-minute test, after which the unit will return
to normal operation. – Press the 60 mins button to perform a 60-minute test, after which the unit will return
to normal operation. – To cancel the test, press the OFF button. 9. An audible warning will sound from the battery checker in the following scenarios. – The unit has been stored for a long time causing the battery’s charge to fall extremely low. – The emergency light has drained the battery until it is almost completely exhausted.

Important Note on Using the Unit
1. Always press the “ON” switch every time after installation to turn on the unit. 2. When the unit is not in use always turn it off by pressing the “OFF” switch. 3. The unit should be stored in temperatures under 25 Degree Celsius and the battery
should be charged every 3 months to maintain its operational life. 4. Every time the front cover of the machine is opened for any purpose. When finished,
the power cable should be stored before closing the front cover and the locking clip must be securely locked on the front cover to prevent water and dust.

Initial Trouble Shooting

Problem
– Power not getting to the unit after plugging in. The LED AC light does not turn on.

Cause

What to do

– The power socket might not have any power.
– The plug or socket is loose. – The AC. fuse is blown.

– Check the 220-240VAC power supply.
– Check the plug and socket. – Contact customer service.

– Emergency light does not turn on after the power went out.

– The unit is not plugged in.

– Check that the unit is plugged in.

– The lamp holder or connector is loose. – Check whether the lamp holders and

connectors are properly attached.

– The lamp is faulty. – The DC fuse is blown.

– Contact customer service. – Contact customer service.

– Emergency light only turns on for a short time after the power went out.

– The battery is not fully charged. – The battery has degraded.

– Fully charge the battery.
– Contact customer service to replace the battery

– There is dust or water inside the device.

– Locking clip Is not tight. – The rubber seal is not completely
closed or there is a cable over it.

– Check the lock clip by locking it firmly. – Check the rubber seal if there is a
cable over it or not, keep the cable inside the unit neatly.

Dimension (mm)

H 250 H 250 H 250

L 270
FRONT VIEW

235 L 270
BACK VIEW

W 90
SIDE VIEW

How to use the remote

Remote Testing
5 30 60 secs mins mins

Perform a 5 second test.
Perform a 30 minute test.
Perform a 60 minute test.
Increase the lamp’s brightness
(only available with the HZ lamp type)
Decrease the lamp’s brightness
(only available with the HZ lamp type)
Turn on/off the emergency lamp or cancel any test in progress.

Terms for Warranty and Service
1. The Warranty will only be covered if the customer fills in the “warranty registration form” and
mail the return part back to the company within 7 days from the day of purchase. If this is not
carried out the warranty will be considered void.
2. The warranty only covers the unit’s internal parts. The conditions and durations for the warranty of each part is as specified and the duration of the warranty is calculated from the date of purchase.
3. Please show your warranty card every time you contact our service center or the dealer you
purchased the product from. 4. Products that fall into the following category are considered not covered by the warranty.
The product was used in a way not specified in the manual. The product was used with accessories not meeting the required specifications specified in
the manual. The product seems to have been damaged from being dropped or from strong impact, for example, the parts are loose, dented, scrapped or misshapen. The product has been repaired or modified by personnel not authorized by our company.
The Warranty Void sticker is torn or removed. The product is damaged from careless use or incorrect maintenance, for example, the battery is swollen from overcharging, quick charging was used on the battery, the battery terminals have been short-circuited, the unit was used until the battery was completely discharged and not recharged immediately, the product was stored for long periods until the Battery Checker warning activates and still it is not plugged-in to charge or taking the battery to normal temperature conditions and not recharging it every 1 month. The product was stored in an unsuitable environment, for example, a location with moisture
or water vapor. The product was supplied with a faulty AC power supply such as electrical overvoltage, electrical current surges, or lightning strikes entering the AC power line. Damages from natural causes such as fire, being summered in fluids, humidity, chemicals or
force majeure. Damages from insects or animals.
Note : Please read the manual carefully before installation and operation to understand how to
properly operate the unit.

For any further questions about your product please feel free to contact SUNNY’s customer service department. Tel. (+66) 02-948-4450-2 E-mail: service@sunnyemergencylight.com

IsOn Import-Export Co., Ltd.
2915-2917 Ladprao Road, Klongjan, Bangkapi, Bangkok 10240

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Sunny User Manuals

Related Manuals