DECATHLON Scale 700 Connected Scales with Impedance Meter User Manual
- June 6, 2024
- DECATHLON
Table of Contents
Scale
700
Overview
LED SCREEN
| Results of body fat percentage analysis|
%
| Percentage
---|---|---|---
| Results of muscle mass percentage analysis| | Men
| Results of body water percentage analysis| | Sportsman
| The bone mass analysis result| | Women
Age
| Age| | Sportswoman
ft
| Feet| | User Profile
St
lb
| Stone| | Bluetooth® connection
lb
| Pounds| | Data transmission/Waiting to transmit to the smartphone
Cm
| Centimeter
kg
| Kilogram| | Low battery
PRECAUTIONS FOR USE
Using this impedance analysis scale is not recommended for people fitted with
pacemakers or any other kind of implanted medical device. If you are not sure,
ask your doctor for advice.
To ensure an accurate measurement, you must observe the following instructions
:
- Place the scale on a hard, flat surface. Soft surfaces such as carpets could affect the measurements.
- Do not repeat measurements several times throughout the day as they are not comparable.
- Do not move the scale between measurements.
- It is best if you weigh yourself before having eaten anything and if you do not weigh yourself directly after sports.
- Always weigh yourself at the same time of day in order to ensure consistency when monitoring your body parameters.
USAGE INSTRUCTIONS
Installing the batteries
-
Open the battery compartment on the back of the scale
-
Insert the batteries (4 x 1.5V AAA) in accordance with the marked polarity (+/-)
• A welcome message will be displayed. -
Close the compartment and place your scale on the floor. After 30 seconds, your scale will turn off automatically.
WARNING :
When the symbol appears, the device will shut down. You must then replace all
four batteries at the same time. Do not combine used batteries and new
batteries. Used batteries are hazardous waste. Do not dispose of them in
household waste. Refer to local regulations and to recycling instructions for
how to dispose of used batteries.
Choosing the unit of measurement
Press the «Unit/Pairing» button underneath the scale to select the unit of measurement. The default unit of measurement is the «kilogram». You can also choose to use «pounds» or «stone».
First use
- Download the Decathlon Connect app.
- Activate Bluetooth® on your phone
- Launch the Decathlon Connect app and follow the instructions. When asked to put your scale into detection mode, press and hold the «Pairing» button located on its underside for 2 seconds. An on-screen animation indicates that the scale is in «Pairing» mode.
- When the scale is correctly paired to your account, the following will appear on the screen:
Your scale configures itself automatically by collecting the information from your Decathlon Connect account (age, height, gender).
Multi-user operation
If the scale is used by several users, each user must follow these steps with
their own Decathlon Connect account. This allows each Decathlon Connect
account to be linked to a unique user profile. In this way, only your personal
measurements will be transferred to your account.
DAILY USE
WEIGHING
Stand barefoot on your scale with your feet placed centrally upon it. Your scale will turn on automatically.
Once your weight is stabilized, remain still until the analysis of your body composition is complete. An animation indicates that the analysis is in progress.
Your scale can recognize up to 8 users. If your identity is not clear, it will
ask you to choose your profile number.
Select it using the left and right buttons:
If no user is recognized, only the weight will be displayed.
When the analysis is finished, the results of your measurements are displayed one after the other:
TRANSFERRING MEASUREMENTS TO YOUR SMARTPHONE
Activate Bluetooth® on your smartphone and launch the Decathlon Connect app.
Your measurements will be sent to your smartphone automatically.
Your scale turns off automatically after weighing.
Multi-user operation
Ensure that you are logged into your Decathlon Connect account on your
smartphone in order to receive the measurements linked to your profile.
BODY MEASUREMENTS
Body fat
The bar at the top of the screen indicates your body fat level.
Standard values for men
Assessment | Age |
---|---|
20 – 29 | 30 – 39 |
Low | 13 |
Normal | 14-20 |
High | 21-23 |
Very High | >23 |
Standard values for women
Assessment | Age |
---|---|
20 – 29 | 30 – 39 |
Low | 19 |
Normal | 20-28 |
High | 29-31 |
Very High | >31 |
BODY WATER
| Body fat percentage| Optimal body water percentage
---|---|---
Men| 4 to 14%| 70 to 63%
15 to 21°/0| 63 to 57%
22 to 24%| 57 to 55%
25% and above| 55 to 37%
Women| 4 to 20%| 70 to 58%
21 to 29%| 58 to 52%
30 to 32%| 52 to 49%
33% and above| 49 to 37%
Muscle mass: Men: around 40% of total weight. Women: around 30% of total
weight.
Bone mass: For both men and women, average bone mass accounts for around
4-5% of body weight.
TECHNICAL SPECIFICATIONS
Product name | Scale 700 |
---|---|
Dimensions | 310 x 310 x 28.5 mm |
Weight | Approximately 1.75 kg (without batteries) |
Units of measurement | Kilogram/Pound/Stone |
Measurement range | 5 kg to 180 kg/0 st: 11 lb to 28 st: 5 lb/11 lb to 397 lb |
Graduation | 0.1 kg/0.2 lb |
Accuracy | 50 kg: ± 0.3 kg 100 kg: ± 0.4 kg 150 kg: ± 0.5 kg 180 kg: ± 0.7 kg |
Operating conditions | Temperature: 10°C to 40°C / Humidity: 15% – 90% RH |
Storage conditions | Temperature: -20 °C to 55 °C / Humidity: 5 90% RH |
Power supply : | 6V (four AAA batteries) |
EU DECLARATION OF CONFORMITY
This product complies with the RED Directive 2014/53/EU. The EU declaration of conformity is available via the following link: https://support.decathlon.fr/scale700DOC
CONTACT US
We would like to hear your feedback on the quality, features, and use of our products at: https://www.supportdecathlon.com/. We will reply as soon as possible.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.
«This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: 1 This device may not c use harmful
interference, and (2) this device must accept any interference received,
including interference that May cause .undesired operation.»
CAUTION: Chames or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits
tor a Class B digital device, pursuant to Part 15 of the I-CC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and if not installed and used in accordance
with the instructions, Ho may cause harmful interference to radio
communications. however, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
User is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Industry Canada licence-exempt RSS standards. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2 this device must accept any interference. including interference that may cause undesired operation of the device.
DECATHLON – 4 BOULEVARD DE MONS
– BP 299 – 59650 VILLENEUVE D’ASCQ
CEDEX – FRANCE
Made in China
Read User Manual Online (PDF format)