COMMSCOPE L4HM-D Heliax LDF-4 Cables
PRODUCT INFORMATION
MODEL NO.: COMMSCOPE L4HM-D Heliax
REQUIRED TOOLS
L4HM-D, L4HF-D, L4HR-D, L4DM-D Connector Installation for HELIAX® LDF4 Cables HL4RPV-50 and AL4RPV-50
OVERVIEW
CommScope Infrastructure L4HM-D Academy L4HF-D offers . installation L4HR-D training. L4DM-D
Installation Instructions
- Straighten the cable and cut the end square using cable cutter.
- Apply forward pressure until you feel the ball bearings land in a corrugation valley. Reverse tool to remove. End of the prep tool can be used as a guide.
- If all of the outer jacketing wasn’ t removed during initial cabl prep remove at this time. Slide the clamping nut over the cable end. Install pre-lubricated o-ring in the 5th corrugation.
- Push the collet back over the O-ring until it stops, then release it. Verify that the collet has located into the first corrugation. DO NOT TWIST. Clean off face of foam with alcohol wipe.
- To achieve optimum Return Loss, pull outer body to remove coring bit from the tool. Place bit over inner conductor and push forward until bit contacts face of foam. BEFORE turning drill push HARD depressing foam. Maintaining force, turn drill at 1 /4 trigger until tool bottoms out. Clean foam from coring bit and repeat, carefully remove any loose foam with non-metallic tool.
- Remove any foam dielectric and excess adhesive on inner conductor up to the end of outer conductor using provided foam removal tool. Squeeze the tool at the base of inner conductor and pull towards yourself.
- Caution : Do not apply coring/flaring bit until rear collet is in place (step 4).
- To achieve optimum PIM, use included alcohol wipe on the exposed inner, outer and remaining foam on the inner to remove any remaining particles
- WARNING : Do not remove foam from inner. Carefully examine ends of outer and inner conductors. If cuts are not clean or either conductor looks scratched, damaged or distorted, remove components, cut off cable and refit.
- Tip : A bright flashlight can help detect particles and clean pressurized air can be useful to blow out the particles.
- Slide the outer body over the collet and rotate slightly to align socket within the outer body with th hex edge on the collet. Push until fully engaged.
- Slide the clamping nut up to the outer body and tighten by hand by turning the clamping nut and holding the front body stationary. Complete the installation by tightening with torque and open ended wrenches.
- Tighten coupling nut to the proper torque specification.
CommScope
1100 CommScope Place SE P.O. Box 339, Hickory, NC 28603-0339
828-324-2200
800-982-1708
www.commscope.com
Customer Service 24 hours
- North America: + 1-800-255-1479 (toll free)
- Any country :+ 1-779-435-6500
- email : acicustomersupportcenter@commscope.com
Notice : CommScope disclaims any liability or responsibility for the
results of improper or unsafe installation, inspection, maintenance, or
removal practices.