Introducing the APC EPDU1016B Power Distribution Unit (PDU): Your Reliable Solution for Efficient Power Distribution. The APC EPDU1016B is a Basic Rack Power Distribution Unit designed to efficiently distribute electrical power to multiple devices in your rack or enclosure. With its robust features and compatibility with international voltage standards, this PDU ensures reliable and safe power distribution for data centers, server rooms, and rack-mounted equipment setups. In this introduction, we’ll explore the key benefits and functionalities of the APC EPDU1016B, making it an essential component for your power management needs.

Easy PDU

Basic Rack Power Distribution Unit

The APC by Schneider Electric Easy PDU, Basic Rack Power Distribution Unit EPDU1016B distributes power to devices in the rack.

  • Outlets: The Rack PDU has eight (8) IEC 320 C13, 10A outlets.
  • Power cord: The power cord is 2.5 m (8.2 ft) in length, with IEC-320 C19 to C20 (16A) connectors.
  • Mounting: Two brackets and mounting hardware are provided with the Rack PDU. The Rack PDU can be mounted in a 19-inch NetShelter™ rack or other EIA-310-D standard 19-inch rack.

Features

  • Efficient Power Distribution: The APC EPDU1016B is designed to efficiently distribute power to devices in your rack or enclosure, ensuring consistent and reliable power supply.
  • Ample Outlets: This Rack PDU comes equipped with eight (8) IEC 320 C13 outlets, providing sufficient connections for your equipment.
  • Robust Construction: Built with high-quality materials, the APC EPDU1016B is durable and reliable, ensuring long-lasting performance.
  • Compatibility: The PDU is compatible with a wide range of equipment and can be mounted in a 19-inch NetShelter™ rack or any EIA-310-D standard 19-inch rack.
  • Nominal Input Voltage: Supports a nominal input voltage range of 200-240 VAC, suitable for various power environments.
  • Maximum Output Current: Offers a maximum output current of 10A per outlet and 16A per phase, providing ample power for connected devices.
  • Safety and Compliance: The PDU complies with safety and environmental standards, including CE, TUV, UKCA, and RoHS.
  • Environmental Conditions: Designed to operate in a wide range of environmental conditions, including temperatures from -5 to 45°C and humidity levels from 5% to 95% RH (non-condensing).
  • Compact Design: The unit’s compact dimensions (44.4 x 482 x 44.4 mm) allow for easy installation in tight spaces.

Specifications

Electrical

Nominal Input Voltage| 200 – 240 VAC
Maximum Input Current (Phase)| 16A
Input Frequency| 50/60Hz
Input Connection| IEC-320 C20 (16A)
Output Voltage| 200 – 240 VAC
Maximum Output Current (Outlet)| 10A
Maximum Output Current (Phase)| 16A
Output Connections| IEC 320 C13 (10A)
Output Quantities| Eight (8)
Physical
Dimensions (H x W x D)| 44.4 x 482 x 44.4 mm (1.75 x 19 x 1.75 in)
Input power cord length| 2.5 m (8.2 ft)
Shipping dimensions (H x W x D)| 150 x 560 x 80 mm (3.8 x 22.8 x 3.15 in)
Weight/Shipping weight| 0.58 kg (1.27 lb) / 1.18kg (2.60 lb)
Environmental
Maximum elevation (above MSL) Operating/Storage| ****

0–3000 m (0–10,000 ft) / 0–15000 m (0–50,000 ft)

Temperature: Operating/Storage| –5 to 45°C (23 to 113°F) / –25 to 65°C (–13 to 149°F)
Humidity: Operating/Storage| 5–95% RH, non-condensing
Compliance
EMC verification| CE EN55035, EN55032, EN55024
Safety verification| CE, TUV, UKCA, EN/IEC62368-1
CE EU Contact Address| Schneider Electric, 35 rue Joseph Monier 92500 Rueil Malmaison France
Environmental| RoHS & Reach

Customer support and warranty information are available on the APC by Schneider Electric website, www.apc.com.

© 2021 APC by Schneider Electric. APC and the APC logo are owned by Schneider Electric S.E. All other trademarks are property of their respective owners.

990-91336A

11/2021

Frequently Asked Questions

What is the APC EPDU1016B Power Distribution Unit used for?

The APC EPDU1016B is a Basic Rack Power Distribution Unit designed to distribute power to devices in a rack. It provides electrical outlets for connecting equipment in data centers, server rooms, and rack-mounted setups.

How many outlets does the APC EPDU1016B have?

The APC EPDU1016B Power Distribution Unit has eight (8) IEC 320 C13 outlets with a maximum current rating of 10A.

What is the length of the power cord for this unit?

The power cord included with the APC EPDU1016B is 2.5 meters (8.2 feet) long and features IEC-320 C19 to C20 (16A) connectors.

Can I mount the APC EPDU1016B in a rack, and if so, what type of racks is it compatible with?

Yes, the APC EPDU1016B can be mounted in a 19-inch NetShelter™ rack or any EIA-310-D standard 19-inch rack. It comes with two brackets and mounting hardware for installation.

What is the nominal input voltage and frequency for this power distribution unit?

The APC EPDU1016B operates with a nominal input voltage of 200 - 240 VAC and supports an input frequency of 50/60Hz.

What is the maximum input current (phase) supported by this unit?

The maximum input current for this unit is 16A per phase.

What are the environmental specifications for this power distribution unit?

The APC EPDU1016B is designed to operate in an environment with a maximum elevation (above MSL) of 0–3000 meters (0–10,000 feet) and can be stored at elevations of 0–15000 meters (0–50,000 feet). The operating temperature range is from -5 to 45°C (23 to 113°F), and the storage temperature range is from -25 to 65°C (-13 to 149°F). It operates in a humidity range of 5–95% RH (non- condensing).

Is the APC EPDU1016B compliant with any safety and EMC standards?

Yes, the unit complies with various safety and EMC (Electromagnetic Compatibility) standards, including CE EN55035, EN55032, EN55024, CE, TUV, UKCA, and EN/IEC62368-1.

Who is the manufacturer of the APC EPDU1016B?

The APC EPDU1016B Power Distribution Unit is manufactured by Schneider Electric, with the contact address at 35 rue Joseph Monier 92500 Rueil Malmaison, France.

Are there any environmental compliance certifications for this unit?

Yes, the APC EPDU1016B is compliant with RoHS and Reach environmental standards.

What is the purpose of a Power Distribution Unit (PDU)?

A Power Distribution Unit (PDU) is designed to distribute electrical power to multiple devices or equipment within a rack. The APC EPDU1016B is a Basic Rack PDU used for this purpose.

What is the maximum load capacity of the APC EPDU1016B?

The APC EPDU1016B has a maximum output current of 16A per phase and provides eight (8) IEC 320 C13 outlets with a maximum load capacity of 10A each.

Reference: APC EPDU1016B Power Distribution Unit Specification and Datasheet- Device.Report

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

APC User Manuals

Related Manuals