steinel RS LED D2 S LED Ceiling Lamp Instruction Manual

June 13, 2024
STEINEL

steinel RS LED D2 S LED Ceiling Lamp

steinel-RS-LED-D2-S-LED-Ceiling-Lamp-FIG-1

Product Information

  • The product is a sensor-switched indoor light with an active motion detector. It is designed for installation indoors and is equipped with a high-frequency (HF) sensor that emits electromagnetic waves at a frequency of 5.8 GHz. The sensor detects any movement within the light’s detection zone by analyzing the change in echo caused by the movement. A microprocessor then issues a switch command to turn the light on.
  • The package includes the following components:
    • Shade
    • Electronics enclosure
    • HF sensor
    • Connecting terminal
    • Night light
    • Time setting
    • Reach adjustment
    • Twilight setting
  • The product dimensions are as follows:
    • Length: 300 mm
    • Width: 300 mm
    • Height: 52 mm

Product Usage Instructions

Electrical Installation

  • Before starting the electrical installation, make sure to disconnect the power supply. The mains power supply lead consists of a 3-core cable with the following conductors:
    • L = phase conductor (usually black, brown, or grey)
    • N = neutral conductor (usually blue)
    • PE = protective-earth conductor (green/yellow)
  • If you are unsure about the conductors, use a voltage tester to identify them. Once identified, connect the phase conductor (L) and neutral conductor (N) to the terminal block. Incorrectly wired connections may cause a short circuit, so double-check the wiring to ensure it is correct. You can also install a mains power switch in the supply lead for easy ON/OFF control of the unit.

Mounting
Choose a suitable location for mounting the sensor-switched indoor light. Ensure that there is at least 3 meters of distance between the light and any Wi-Fi routers or access points. This distance is necessary to avoid interference with the HF sensor.

Function

  • The sensor-switched indoor light has various adjustable functions:
    • Time setting: The factory default is 5 seconds.
    • Reach adjustment: The factory default is 8 meters.
    • Twilight setting: The factory default is 10% brightness.
  • The night light is activated when the brightness falls below the set threshold. If the daylight function is enabled, the night light will always be active.

Disposal
Follow the local regulations for the proper disposal of the product. Do not dispose of it with regular household waste.

Manufacturer Warranty
The product is covered by a manufacturer’s warranty. Refer to the warranty documentation provided for more information.

Technical Specifications

Here are the technical specifications of the product:

  • Input voltage: 50-250V~
  • Power consumption: 100-150W
    Please consult the complete user manual for detailed instructions and safety information.

About this document

Please read carefully and keep in a safe place.

  • Under copyright. Reproduction either in whole or in part only with our consent.
  • Subject to change in the interest of technical progress.

Symbols

General safety precautions

Disconnect the power supply before attempt-ing any work on the unit.

  • During installation, the electric power cable being con-nected must not be live. Therefore, switch off the power first and use a voltage tester to make sure the wiring is off-circuit.
  • Installing the sensor-switched light involves work on the mains supply voltage. This work must therefore be car-ried out professionally in accordance with national wiring regulations and electrical operating conditions. ( e.g. DE- VDE 0100, AT- ÖVE / ÖNORM E8001-1, CH- SEV 1000 )
  • Only use genuine replacement parts.
  • Repairs may only be made by specialist workshops.

RS LED D2 S

Proper use
Sensor-switched indoor light with active motion detector for installing indoors

  • Note:
    • When installing, please always allow a distance of at least 3 m to Wi-Fi routers or access points.
    • The integrated HF sensor emits high-frequency electromag-netic waves ( 5.8 GHz ) and receives their echo. The change in echo caused by the slightest movement within the light’s detection zone is detected by the sensor. A microprocessor then issues the switch command “switch light ON”. Detec-tion is possible through doors, panes of glass or thin walls.
  • Note:
    The high-frequency power of the HF sensor is approximate-ly 1 mW – 1000 times less than the transmission power of a mobile phone or microwave oven.

Package contents ( Fig. 3.1 )

Product dimensions ( Fig. 3.2 )

Product components ( Fig. 3.3 )

steinel-RS-LED-D2-S-LED-Ceiling-Lamp-FIG-4

  • A Shade
  • B Electronics enclosure
  • C HF sensor
  • D Connecting terminal
  • E Night light
  • F Time setting
  • G Reach adjustment
  • H Twilight setting

Detection zones for ceiling mounting
3-8 m ( Fig. 3.4 )

Detection zones for wall mounting
2.50 m ( Fig. 3.5 )

Electrical installation

  • Wiring diagram ( Fig. 4.1 )
  • The mains power supply lead is a 3-core cable:
    • L = phase conductor ( usually black, brown or grey )
    • N = neutral conductor ( usually blue )
    • PE = protective-earth conductor ( green/yellow )
  • If you are in any doubt, identify the conductors using a voltage tester; then disconnect from the power supply again.
  • Connect the phase conductor ( L ) and neutral conductor ( N ) to the terminal block.

Important:

  • Incorrectly wired connections will produce a short circuit later on in the product or your fuse box. In this case, you must identify the individual conductors once again and reconnect them. A mains power switch for turning the unit ON and OFF may of course be installed in the mains supply lead.

  • The light source of this luminaire cannot be replaced. If the light source needs to be replaced ( e.g. at the end of its service life ), the complete luminaire must be replaced.

  • Connection to a dimmer will result in damage to the sensor- switched light.

Mounting

  • Check all components for damage.
  • Do not use the product if it is damaged.
  • When installing the sensor-switched light, make sure the installation site is not exposed to vibration.
  • Select an appropriate mounting location, taking the reach and motion detection into consideration.

Mounting procedure

  • Switch OFF power supply ( Fig. 4.1 )

  • Mark drill holes ( Fig. 5.1 )

  • Drill holes and insert wall plugs ( Fig. 5.2 )

  • Installation with concealed power supply lead ( Fig. 5.3 )

  • Installation with surface-mounted power supply lead ( Fig. 5.4 )

  • Connect conductors ( Fig. 5.5 )

steinel-RS-LED-D2-S-LED-Ceiling-Lamp-FIG-12

  • Make settings ➔ “6. Functions” ( Fig. 5.6 )

  • Fit shade ( Fig. 5.7 )

  • Switch ON power supply ( Fig. 5.7 )

Function

The sensor-switched light can be put into service after mounting the enclosure and connecting to the mains power supply. When putting the light into operation manually at the light switch, the light will switch OFF after 10 seconds for the calibration phase and is then activated for sensor mode. It is not necessary to operate the light switch a second time.

Function – control dials ( Fig. 6.1 )

Factory settings:

  • Time setting: 5 seconds
  • Reach setting: 8 m
  • Twilight level: 2000 lux
  • Basic brightness: 10%

Time setting ( stay-ON time ) ( Fig. 6.1/F )
The light’s ON time can be set to any period from approx. 5 seconds to a maximum of 15 minutes. Any movement detected before this time elapses will restart the timer.
Note:
After the light switches OFF, it takes approx. 1 second before it is able to start detecting movement again. The light will only switch ON in response to movement once this period has elapsed.
The shortest time setting is recommended when adjusting the detection zone and performing the functional test.

Reach setting ( sensitivity ) ( Fig. 6.1/G )
Reach is the term used to describe the diameter of the more or less circular detection zone produced on the floor after mounting the sensor-switched light at a height of 2.50 m.

  • Control dial set to maximum = max. reach ( 8 m )
  • Control dial set to minimum = min. reach ( 2.50 m )

Twilight setting / response threshold ( Fig. 6.1/H )

  • The light’s chosen response threshold can be infinitely varied from approximately 2 to 2000 lux.
    • Control dial set to = daylight mode ( depending on ambient brightness )
    • Control dial set to = twilight mode ( approx. 2 lux )
  • The control dial must be turned to when adjusting the detection zone and performing the functional test in daylight.

Night light ( Fig. 6.1/E )

  • The night light provides illumination at approx. 10% of full light output. The light only switches to maximum output ( 100% ) in response to movement in the detection zone ( see Time setting ). The light then switches to the activated night light level.
    • Control dial set to = night light activated
    • Control dial set to 0 = night light deactivated
  • Night light is ON when the level of light falls below the brightness threshold. Night light is always ON when daylight mode is activated.

Manual override function
If a mains switch is installed in the mains supply lead, the following functions are available in addition to simply switching light ON and OFF:

Manual override ( Fig. 6.2 )

  1. Activate manual override:
    Switch OFF and ON twice. Light is set to manual override for 4 hours. Then it returns automatically to sensor mode.

  2. Deactivate manual override:
    Switch OFF and ON once. Light goes out or switches to sensor mode.
    Important:
    The switch should be actuated in rapid succession ( in the 0.2 to 1 second range ).

Disposal

  • Electrical and electronic equipment, accessories and packaging must be recycled in an environmentally compatible manner.
  • Do not dispose of electrical and electronic equipment as domestic waste.

EU countries only
Under the current European Directive on Waste Electrical and Electronic Equipment and its implementation in national law, electrical and electronic equipment no longer suitable for use must be collected separately and recycled in an environmentally compatible manner.
Important note: the control gear cannot be replaced.

Declaration of Conformity

Hereby, STEINEL Vertrieb GmbH declares that the radio equipment type RS LED D2 S is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.steinel.de

Manufacturer’s warranty

  • This Steinel product has been manufactured with utmost care, tested for proper operation and safety and then subjected to random sample inspection. Steinel guarantees that it is in perfect condition and proper working order. The warranty period is 36 months and starts on the date of sale to the consumer. We will remedy defects caused by material flaws or manufacturing faults. The warranty will be met by repair or replacement of defective parts at our own discretion. The warranty shall not cover damage to wear parts, damage or defects caused by improper treatment or maintenance. Further consequential damage to other objects shall be excluded.
  • Claims under the warranty will only be accepted if the unit is sent fully assembled and well-packed with a brief description of the fault, a receipt or invoice ( date of purchase and dealer’s stamp ) to the appropriate Service Centre.

Repair service:
If defects occur outside the warranty period or are not covered by warranty, ask your nearest service station for the possibility of repair.

Technical specifications

  • Dimensions W x H × D 300 × 300 × 65.5 mm

  • Supply voltage 220 – 240 V, 50/60 Hz

  • Power consumption (Pon) 8.80 W

  • Luminous flux 886 lm

  • Efficiency 101 lm/W

  • Standby sensor (Psb) 0.39 W

  • Colour temperature 3,000 K (warm white)

  • Colour rendering index Ra = 82

  • Average rated life expectancy L70B50 at 25°C: > 60,000 hours

  • Colour consistency SDCM Starting value: 3

  • Luminous intensity distribution

  • Material plastic

  • HF technology 5.8 GHz

  • Angle of coverage 360° with 160° angle of aperture

  • Time setting 15 s to 15 min

  • Twilight setting 2 – 2,000

  • IP rating IP20

  • Protection class II

  • Power consumption 630 mW

  • Ambient temperature -10°C to +40°C

  • Transmitter power ≤ 2.5 mW

Troubleshooting

steinel-RS-LED-D2-S-LED-Ceiling-Lamp-FIG-23

ABOUT COMPANY

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

STEINEL User Manuals

Related Manuals