ELRO CBFS58R Smoke Alarm Device Instruction Manual
- June 4, 2024
- ELRO
Table of Contents
ELRO CBFS58R Smoke Alarm Device
Wireless connected
Ground floor
First floor
Attic
INTENDED USE: FIRE SAFETY
ESSENTIAL CHARACTERISTICS: PASSED
Firstly
Follow instructions to ensure proper installaon. Intended use: Fire detection and fire warning for household or similar residenal applications. Local regulations shall be consulted.
Content
Activate
Test not okay, replace alarm
5a
Press for approximately 15 seconds un l the bu Aon lights up completely. The
30 seconds of pairing mode starts. As long as the led is ON pairing mode is ac
ve.
Follow process according alarm fB or adding for more smoke alarms.
5b
IMPORTANT – Ater connecting waits 20 minutes before testing.
Rooms
Low battery alert? Replace battery and test! (see 2 and 3). Mute warning for 8 hours: press the test button.
ALARM PATTERN – ALARMBILDUNG – ALARM PATROON – PATTERN D’ALARME Smoke – Rauch
– Rook – Fumée
Bi 0,5s – Pause 0,5s – Bi 0,5s Pause 0,5s – Bi 0,5s Pause 1,5s + Led
ALARM PATTERN – ALARMBILDUNG – ALARM PATROON – PATTERN D’ALARME Heat – Hi e –
Hitze – Chaleur
Bi 0,2s – Pause 0,1s + Led
ALARM PATTERN – ALARMBILDUNG – ALARM PATROON – PATTERN D’ALARME Wireless alarm
– Drahtoser Alarm – Draadloos alarm – Alarme sans fil
Bi – Bi 0,2s – Pause 1,2s + Led
| LED signal (flash)| Acous c signal (Bip)| Descrip on mode
---|---|---|---
Normal| 1 x per 40 seconds| None| Device is functioning properly
Test| 1 x per second (3 x), pause of 1,5 seconds| 1 x per second (3 x), pause
of 1,5 seconds| Device is being tested
Alarm| 1 x per second (3 x), pause of 1,5 seconds| 1 x per seconds (3 x),
pause of 1,5 seconds| Device has detected smoke
Low battery| 1 x per 40 seconds (simultaneously with beep)| 1 x per 40 seconds
(simultaneously with flash)| Battery is running low
Fault warning| None| 1 x per 40 seconds| Device is not functioning properly
Symbols:
Recycling and disposal: The WEEE symbol means that this product and ba eries
must be disposed separately from other household waste. When it reaches its
end of life, take it to a designated waste collec on point in your area to
guarantee a safe disposal or recycling. Protect the environment, human health
and natural resources!
Read the manual before use and store it in a safe place for future use and
maintenance. Download Declara on of Performance (DoP) at
www.elro.eu.
Warnings:
- Replace smoke alarm device 10 years aerial ac va on.
- To prevent injury, this apparatus must be securely attached to the ceiling in accordance with the installa on instruc ons.
- Batteries shall not be exposed to excessive heat such as sunshine and fire.
- Battery life me shortens without monthly test.
- Keep away from air conditioning/ven la on.
- Do not paint or cover device.
- Consult local regulaions.
Troubleshooting: False alarm is one caused by dust or steam. In case of doubt: Leave the building and take ac on! Additional mounting instructions: Corridor max width 3m: Max 15m between 2 alarms. Max. 7,5m to front side and alarms at edges/crossings of corridors. Galleries: Length and width >2m and >16m², additional alarms below gallery. Par al roof slopes: Flat ceiling ≤1m wide, consider as roof slope. Flat ceiling >1m wide, consider as flat ceiling.
0905
DoP: CBFS58R-01 21 CBFS58R
Manufacturer
Siterwell Electronics CO., Limited
No.666 Qingfeng Road, Jiangbei District, Ningbo, Zhejiang Province, China
315034
Importer:
ELRO Europe | www.elro.eu Postbus 9607 – Box E800
1006 GC Amsterdam The Netherlands