APC AP6015A Power Distribution Unit Specification and Datasheet

June 13, 2024
APC

APC AP6015A Power Distribution Unit

Introduction

The APC AP6015A Power Distribution Unit, or PDU, is a reliable and essential component for efficiently distributing power to various devices within a data center or server rack. Designed by American Power Conversion (APC), this PDU ensures safe and organized power delivery, making it a crucial element for businesses and organizations seeking to manage their IT infrastructure effectively. With features like cord retention trays and flexible mounting options, it simplifies installation and maintenance, while its robust warranty and service options provide peace of mind for users.

Basic Rack PDU AP6015A

Overview

The APC Basic Rack Power Distribution Unit (PDU) distributes power to devices in the rack.

  • Outlets: The Rack PDU has eight (8) C13 outlets.
  • Power cord: The Rack PDU has an IEC-320 C14 inlet and can be used with a detached power cord (not provided).

Features

The APC AP6015A Power Distribution Unit (PDU) offers several key features to enhance power distribution and management in data centers and server racks:

  • Ensures that the product arrives intact, with all components, and provides a process for reporting any shipping damage or missing items.
  • These trays help keep power cords organized and secured, preventing accidental disconnections and ensuring reliable power distribution.
  • The PDU can be installed vertically or horizontally, using toolless mounting pegs or brackets, offering versatility in rack placement.
  • The PDU is not recommended for use in life-support applications where product failure could impact safety or effectiveness. APC provides guidelines for the appropriate use of their products in various settings.
  • APC offers customer support through various channels, including phone and email, to assist with troubleshooting and product issues.
  • The PDU complies with safety standards such as cULus-EU, CE, IRAM, EAC, KTC, and UKCA, ensuring it meets established safety and quality requirements.

These features collectively make the APC AP6015A PDU a reliable and flexible solution for efficient power distribution and management in critical IT environments.

Specifications

Electrical

Input connection| IEC-320 C14 inlet|
---|---|---
Acceptable input voltage| 100–240 VAC (cULus)| 200–240 VAC (IEC)
Maximum input current (phase)| 15 A (12 A cULus)| 10 A (IEC)
Input frequency| 50/60 Hz|
Output voltage| 100–240 VAC (cULus)| 200–240 VAC (IEC)
Output connections (8)| C13|
Maximum output current (outlet)| C13; 12 A (cULus)| C13; 10 A (IEC)
Maximum output current (phase)| 12 A (cULus)| 10 A (IEC)

Physical
Dimensions (H x W x D) 23.97 x 4.36 x 9.29 cm (9.44 x 1.72 x 3.66 in)
Shipping dimensions (H x W x D) 28.60 x 21.03 x 13.00 cm (11.26 x 8.28

x 5.12 in)
Weight| 0.90 kg (2.00 lb)|
Shipping weight| 1.37 kg (3.01 lb)|

Environmental

Maximum elevation (above MSL)| Operating: 0 to 3000 m (0 to 10,000 ft)| Storage: 0 to 15,000 m (0 to 50,000 ft)
---|---|---
Temperature| Operating: 0 to 50°C (32 to 122°F)| Storage: -15 to 60°C (5 to 140°F)
Humidity| Operating: 5 to 95%, non-condensing| Storage: 5 to 95%, non- condensing

Compliance
Safety approvals cULus-EU, CE, IRAM, EAC, KTC, UKCA

Contact Information

  • APC 70 Mechanic Street 02035 Foxboro, MA USA
  • Website: www.apc.com
  • Disclaimer: As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this publication.
  • Copyright: © 2021 Schneider Electric. APC, the APC logo, and EcoStruxure are trademarks of Schneider Electric SE or its subsidiaries. All other brands may be trademarks of their respective owners.

Frequently Asked Questions

What is the APC AP6015A Power Distribution Unit, and what is its purpose?

The APC AP6015A Power Distribution Unit (PDU) is a crucial component designed for efficiently distributing power to various devices within a data center or server rack. It ensures safe and organized power delivery, making it essential for businesses managing their IT infrastructure.

How many outlets does the APC AP6015A PDU have?

The APC AP6015A PDU features eight (8) C13 outlets, providing ample power distribution capabilities.

What type of input connection does the PDU have, and what voltage does it support?

The PDU has an IEC-320 C14 inlet and accepts input voltage ranging from 100–240 VAC (cULus) to 200–240 VAC (IEC).

Can you describe the maximum input and output current for this PDU?

Certainly, the maximum input current for this PDU is 15 A (12 A cULus) and 10 A (IEC). The maximum output current for outlets is C13; 12 A (cULus) and C13; 10 A (IEC).

What are the environmental operating conditions for the APC AP6015A PDU?

The PDU can operate at an elevation of 0 to 3000 m (0 to 10,000 ft) above mean sea level and has an operating temperature range of 0 to 50°C (32 to 122°F). For storage, it can be stored at elevations of 0 to 15,000 m (0 to 50,000 ft) and at temperatures ranging from -15 to 60°C (5 to 140°F).

Does this PDU comply with safety standards?

Yes, the APC AP6015A PDU complies with various safety approvals, including cULus-EU, CE, IRAM, EAC, KTC, and UKCA, ensuring it meets established safety and quality requirements.

How can I obtain customer support for this product?

You can contact APC Customer Support through various channels, including phone or email, for assistance with troubleshooting and product-related issues. Contact information is available on the APC website.

What is the warranty for the APC AP6015A PDU?

APC typically provides a limited warranty, covering two years from the date of purchase. This warranty covers repair or replacement of defective products and applies to the original purchaser. Additional details can be obtained through customer support.

What are the features that make the APC AP6015A PDU stand out as a power distribution solution?

The APC AP6015A PDU offers several key features, including cord retention trays for organized power cord management, flexible vertical and horizontal mounting options, and compliance with safety standards. These features collectively enhance power distribution and management in data centers and server racks.

Can you explain the benefits of using cord retention trays in the APC AP6015A PDU?

Cord retention trays help keep power cords organized and securely attached to the PDU. This prevents accidental disconnections and ensures a reliable and uninterrupted power supply to connected devices.

What are the advantages of the flexible mounting options for the APC AP6015A PDU?

The PDU can be installed vertically or horizontally, offering versatility in rack placement. You can use toolless mounting pegs or brackets, depending on your preference and the specific requirements of your rack or enclosure.

Are there any restrictions on the use of the APC AP6015A PDU in specific applications?

Yes, the APC AP6015A PDU is not recommended for use in life-support applications where product failure could impact safety or effectiveness. It's important to follow APC's guidelines for the appropriate use of their products in various settings.