IPGARD SA-UHN-1S-P Secure KVM Isolator
TECHNICAL SPECIFICATIONS
VIDEO
Format| HDMI
Host Interface| (1) HDMI 19-pin F
User Console Interface| (1) HDMI 19-pin F
Max Resolution| 3840 x 2160 @ 60Hz
DDC| 5 volts p-p (TTL)
Input Equalization| Automatic
Input Cable Length| Up to 20 ft.
Output Cable Length| Up to 20 ft.
USB
Signal Type
| USB 1.1 and 1.0 Keyboard and Mouse only.
USB 2.0 for CAC connection.
USB Type B Inputs| (1) Keyboard-Mouse; (1) CAC
User Console Output Interface
| (2) USB Type-A for keyboard and mouse connection only.
(1) USB Type-A for CAC
connection.
AUDIO
Input| (1) Connector Stereo 3.5mm Female
Output| (1) Connector Stereo 3.5mm Female
POWER
Power Requirements| 12V DC, 3A power adapter with center-pin positive polarity
ENVIRONMENT
Operating Temp| 32° to 104° F (0° to 40° C)
Storage Temp| -4° to 140° F (-20° to 60° C)
Humidity| 0-80% RH, non-condensing
CERTIFICATIONS
Security Accreditation
| Common Criteria Validated To NIAP, Protection Profile PSS Ver. 4.0
OTHER
Emulation| USB 1.1 and USB 2.0
Compatible
Control| Front Panel Buttons
WHAT’S IN THE BOX
PART NO. | QTY | DESCRIPTION |
---|---|---|
SA-UHN-1S-P | 1 | 1-port, Secure HDMI KVM Isolator |
PS12VDC3A | 1 | 12VDC, 3A power adapter with center-pin positive polarity. |
1 | Quick Start Guide |
NOTICE
The information contained in this document is subject to change without
notice. regard makes no warranty of any kind with regard to this material,
including but not limited to, implied warranties of merchantability and
fitness for a particular purpose. iPGARD will not be liable for errors
contained herein or for incidental or consequential damages in connection with
the furnishing, performance or use of this material. No part of this document
may be photocopied, reproduced, or translated into another language without
prior written consent from iPGARD, Inc.
20180122
EDIT LEARN
The KVM is designed to learn a connected monitor’s EDID upon power up. In
the event of connecting a new monitor to the KVM, power recycling is required.
The KVM will indicate the unit’s EDID learn process is active by flashing
the front panel’s LED. The LED will flash green for approximately 10 seconds
upon beginning the EDID learn. Once the LED stop flashing, the power will
cycle and the EDID learn will be complete. A monitor must be connected to the
video output port located in the console space at the back of the KVM during
the EDID learning the process. If the read EDID from the connected monitor is
identical to the current stored EDID in the KVM then the EDID learn function
will be skipped. A full Manual can be downloaded from
www.ipgard.com/documentation
HARDWARE INSTALLATION
- Ensure that power is turned off or disconnected from the unit and the computer.
- Use an HDMI cable to connect the HDMI output port from the computer to the corresponding HDMI IN port of the unit.
- Use a USB cable (Type-A to Type-B) to connect a USB port on the computer to the respective USB ports of the unit.
- Optionally, for CAC models, connect a CAC (Common Access Card, Smart Card Reader) to the CAC port in the user console interface.
- Optionally, connect a stereo audio cable (3.5 mm to 3.5 mm) to connect the audio output of the computer(s) to the audio in the ports of the unit.
- Connect a monitor to the HDMI OUT console port of the unit using an HDMI cable.
- Connect a USB keyboard and mouse in the two USB console ports.
- Optionally, connect stereo speakers to the audio out port of the unit
- Finally, power on the KVM by connecting a 12VDC power supply to the power connector, and then turn on the computer.
Note: You can connect 1 computer to the 1 port KVM.