COMMSCOPE SRC100-12 Splices Novux Fiber Optic System Instruction Manual

June 13, 2024
CommScope

NOVUX™ Fiber Optic System
SRC100 – Patch Application
Installation Instructions

About this manual

This installation instruction document describes the installation of the SRC100 (repair closure). The document starts with providing an overview of the tools required to perform the installation. Also warnings and cautions are indicated, which should be observed before starting the product installation.
Following installation steps are covered in this document: closure preparation, drop cable installation, routing and patching; closing the closure and mounting the closure.
Images in this manual are for reference only and are subject to change.
General product information
1.2 Dimensions

1.3 Cable diameter range

Position Cable diameter
mm inches
Drop cable ≤ 8 (flat cable: 8 x 4.5)

1.4 Fiber type compatibility

Fiber Type| SRC100 – 12 Splices| SRC100 – 24 Splices| SRC100 – 48 Splices| SRC100 – Splice/Patch
---|---|---|---|---
ITU-T G.652D| Yes*| N/A| N/A| N/A
ITU-T G.657| Yes| Yes| Yes| Yes

Note: * Gator application

Abbreviations

SRC100: Repair Closure

Tools

From left to right:

  • Flat screw driver
  • Phillips screw driver
  • Small side cutter
  • Scissors
  • Fiber splice equipment and fiber cleaning tools

Warnings and Cautions

  • Follow the installation instruction steps to ensure the performance of the closure. It is necessary to take precautions and keep the working space clean to protect the closure sealing materials and splices.
  • Exposure to laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not assume the laser power is turned off or that the fiber is disconnected at the other end. Looking into the ends of any optical fiber is entirely at your own risk. A protective cap or hood MUST be immediately placed over any radiating adapter or optical fiber connector to avoid the potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles from entering the connector and adapter.
  • Fiber optic cables may be damaged if bent or curved to a radius that is less than the recommended minimum bend radius. Always observe the recommended bend radius limit when installing fiber optic cables, subunits and patch cords.

Kit contents

Description Qty
1 SRC100 Repair Closure 1
2 Octopus™  gel blocks 2

Closure preparation

6.1 Open the closure

  1. To open the closure, open the 4 latches.
  2. Use a screwdriver to open the metal latch.
  3. Push the 2 levers to the inside and open the closure.
  4. Move the cover and hinges to the back of the closure.
  5. Remove the cover.
  6. Verify the long seal remains correctly seated within the closure cavity.

Note: In case the hinges are not installed yet, please check chapter Install the hinges before closing the closure.
6.2 Install the Octopus™ Gel Blocks
One Octopus ™ gel block must be installed in the cover, another in the base.

  1. Install the Octopus ™ gel block with the plastic support of the gel block down. Push on the gel block until it is secured by the attachment points on the housing.

Install drop cable

7.1 Using jacket strain relief
The instruction for the jacket strain relief is a separate document: TC-1468-IP Cable retention: jacket strain relief (Mclip)
7.2 Prepare drop cable

Description Preparation
1 Jacket Remove the jacket with a distance of 90 cm +/- 2 cm (35.4 +/- 0.8

inches).
2| Tube| Use the target line to indicate the transition zone from tube to fiber.
3| Fiber| Route the fiber.

Patch application

8.1 Patch installation

  1. Install the drop cable (blue) and splice it to the pigtail cable (red).

  2. Install the cover plate over the splice area
    Note: The connectorized pigtail cable (red) length should be 90 +/-2 cm (35.4 +/- 0.8 inches).
    Attention: Make sure all fibers are properly positioned under the lips and avoid bulging of the fiber.

  3. Hinge the adapter 45 degrees upward. Remove the dust caps of the adapter port and the connector and clean per standard practice. Install the connector into the adapter.

  4. Route the cable (follow the arrow direction molded into the cover plate). The cable length should be 45 cm (17.7 inches).

Install the hinges

  1. Install the hinges at the cover.
  2. Install the cover with hinges at the closure base.
  3. Close the cover.

Close the closure

  1. Verify the long seal remains correctly seated within the closure cavity. The seal should be clean and dust free.
  2. Use a screwdriver to close the metal latch.
  3. Close the 4 metal latches.

Mount the closure

11.1 Wall- and Pole mounting with screws

Note: Wall- and Pole mounting hardware not included.
11.2 Pole mounting with straps

Note: Pole mounting hardware not included.

Lock the closure

12.1 Using a security wire

  1. There are 4 locations to secure the closure with a security wire. Push the wire through the holes on the top and bottom cover and seal the wire per local practice.

Disclaimer

All trademarks identified by ® are registered trademarks in the US and may be registered in other countries. All third party product names, trademarks and registered trademarks are property of their respective owners.
This product may be covered by one or more U.S. patents or their foreign equivalents. For patents, see www.cs-pat.com.
This document is not intended to modify or supplement any specifications or warranties relating to CommScope products or services.

Contact information

Visit our website or contact your local CommScope representative for more information. www.commscope.com
For technical assistance, customer service, or to report any missing/damaged parts, visit us at: http://www.commscope.com/SupportCenter

© 2022 CommScope, Inc. All Rights Reserved
TC-1524-IP
Rev. B, May 2022
http://www.commscope.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CommScope User Manuals

Related Manuals