heidolph Findenser Air Condenser for Magnetic Stirrer Instructions
- June 13, 2024
- heidolph
Table of Contents
- heidolph Findenser Air Condenser for Magnetic Stirrer
- Product Information
- Product Usage Instructions
- About this Document
- Versions and variants
- Safety Instructions
- Obligations of the operator
- Device Description
- Start-Up
- Operation
- Cleaning and Maintenance
- Accessories and Spare Parts
- Attachments
- Service
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
heidolph Findenser Air Condenser for Magnetic Stirrer
Product Information
- Product Name: FindenserTM
- Product Type: Air condenser for Magnetic Stirrer
- Features:
- Leading Safety Standards
- Superior Ease of Use
- Reduced Cost of Ownership
Product Usage Instructions
- Installation:
- Choose an appropriate installation site for the Findenser.
- Ensure that there are no modifications made to the Findenser without proper authorization.
- Take necessary precautions for employee safety during the installation process.
- Safety during Use:
- Follow all safety instructions and warnings provided in the operating manual.
- Use the Findenser only for its intended purpose.
- Observe all local regulations at the installation site.
- Cleaning and Maintenance:
- Regularly clean and maintain the Findenser according to the instructions provided in the manual.
- Perform necessary maintenance tasks to ensure optimal performance.
- Troubleshooting:
- Refer to the troubleshooting section in the manual for assistance in case of any issues with the Findenser.
- Assembly: – Follow the assembly instructions provided in the manual when required.
- Disassembly and Storage:
- When disassembling the Findenser, follow the instructions provided in the manual.
- Properly transport and store the Findenser to prevent any damage.
- Accessories and Attachments:
- Refer to the scope of delivery section in the manual for a list of included accessories.
- Follow the instructions for attaching any additional accessories, if applicable.
- Technical Data:
- Refer to the technical data section in the manual for detailed specifications of the Findenser and Findenser Mini.
- Service:
- Contact Heidolph Instruments Germany for any service-related inquiries or assistance.
- Warranty: – Refer to the warranty section in the manual for information regarding warranty coverage.
Please keep this operating manual for future reference and ensure that all users have read and understood it before using the Findenser for the first time.
About this Document
Copyright
- This operating manual is protected by copyright and is exclusively intended for the internal use of the purchaser.
- Handing over this operating manual to third parties, reproducing it in any type or form –in part or in full – and utilizing and/or communicating its contents is prohibited without prior written approval from the manufacturer.
- Any violations will result in an obligation to provide compensation for damages. Other claims remain unaffected.
Versions and variants
Version
This manual describes the function, operation and maintenance of the
Findenser.
- Version 1.0
- Alteration date 01/2023
Variants
The Findenser is available in different variants. Certain features or
functions are only available in specific product variants. These variants are
described in this operating manual.
About this manual
This operating manual is an integral part of the Findenser described here.
- Carefully read through this operating manual and observe all of the safety instructions and warnings notices.
- Ensure that every user has carefully read the operating manual before using the Findenser for the first time.
- Store this operating manual so that it is accessible to all users at all times.
- Pass the operating manual on to any subsequent owner
The current version of this operating manual can also be found at: <https ://heidolph-instruments.com/en/service/downloads/operation- manuals/MagneticStirrers/Findenser>
In addition, also observe the local regulations at the installation site.
Safety Instructions
Symbols and keywords
Standardized symbols and signal words are used in this opera-ting manual to
warn against any dangers and provide important instructions. These
instructions must be strictly observed to avoid accidents and damage.
The following terms and basic symbols are used:
Symbol Additional signal words / explanation
-
Warning signs
The yellow triangle indicates hazardous situations. It is used in combination with the following signal words:-
DANGER:
Indicates a hazardous situation which, if not avoided, will result in serious injury or death. -
WARNING:
Indicates a hazardous situation which, if not avoided, may result in serious injury or death. -
CAUTION:
Indicates a hazardous situation which, if not avoided, may result in property damage and minor or moderate injury.
-
-
Mandatory signs
- Must be observed:
The blue circle indicates important information. Please observe this information to avoid any property damage.
- Must be observed:
Other symbols used:
General safety instructions
- The Findenser has been manufactured according to state-of-the-art technology and in compliance with recognized safety regulations. However, risks may still arise during installation, operation and maintenance.
- Please ensure that the operating manual is available at all times.
The Findenser may only be used under the following conditions:
- Only operate the Findenser if it is in a technically perfect condition.
- Only operate the Findenser in accordance with the instructions given in this operating manual.
- If any information is ambiguous or missing, ask your superior or contact the manufacturer.
- Only use the Findenser in accordance with its intended use.
Intended use
- The Findenser may only be operated by authorized personnel.
- The Findenser may only be operated in combination with a magnetic stirrer
The Findenser is suitable for the following uses:
Reflux cooling
The Findenser may be operated in research laboratories, other laboratories
and production facilities in the following sectors:
- Chemistry
- Pharmacy
- Biology
- Environmental analytics
- Basic research
- Similar research laboratories
- Uninteded use/Reasonable foreseeable misuse
- Any use which deviates from the Findenser‘s intended use is considered to be improper. The manufacturer is not liable for damage that occurs as a result. The risk is borne by the operator alone.
- When used in medical and food sectors the operator alone is responsible for compliance with the applicable regulations and standards.
Obligations of the operator
Installation site
- Ensure that the Findenser and all of its components are easily accessible at all times.
- The Findenser is designed for indoor use only.
- If the Findenser is operated in corrosive atmospheres, the service life of the Findenser will decrease based on the concentration, duration and frequency of the exposure to the corrosive atmosphere e.g. concentrated hydrochloric acid (HCL).
Modifications to the Findenser
- It is not permitted to make any unauthorised modifications or changes to the Findenser.
- The manufacturer is not liable for any damage, dangers or injuries that result from unauthorized modifications and changes or due to the non-observance of the instructions in this manual.
Employee safety
Observe the following instructions to avoid any personal injuries and property damage:
- Laboratory regulations
- Accident prevention regulations
- Hazardous Substance Act
- Other generally accepted occupational health and safety regulations
- Local regulations
Safety during use
- Observe the instructions and safety information given in the Safety Instructions chapter of this manual
- Eliminate errors immediately.
- Do not use abrasive material to clean the surface. Only wipe with damp cloth.
Disposal
- Check the Findenser components for hazardous substances and solvents.
- Clean all components before disposal.
- Dispose of the Findenser in accordance with the relevant national regulations.
- Dispose of the packaging material in accordance with the appropriate national regulations.
Device Description
Findenser overview
Findenser & Findenser Mini
Range of application
The Findenser replaces the need for water-cooled condensers in almost all
common chemistry applications. The suitability must be examined by the user
for every individual case.
Variants
There are two variants available:
- Findenser
- Maximum flask size 2 litres, maximum solvent volume 1 litre
- Findenser Mini
- Maximum flask size 250 ml, maximum solvent volume 125 ml.
Special features
- Patented design
- Sealed assembly
- Optimised internal and external surface areas
- Encapsulated thermofluid, for maximised thermal conductivity and heat transfer
- Finned aluminium jacket
- Excellent thermal conductivity
- High performance air cooling
- Chemically resistant anodised surface
- Anti-roll design with contoured edges to prevent damage to aluminium fins and prevent rolling when being stored
- Easy clamping
- Can be held with conventional laboratory clamps
- Ground glass sockets
- Accepts all standard tapered cones
Start-Up
- Ground glass cones
- Findenser available with B19, B24 or B29 cone
- Findenser Mini available with B14, B19 or B24 cone
- Fit all equivalent standard tapered glass sockets
- Where reference is made to Findenser, actions also apply to Findenser Mini unless otherwise stated.
- In addition to this operating manual, refer to the manufacturers operating instructions for your hotplate and heating block before use with Findenser.
Setting up Findenser
- Please observe all instructions, notes and warnings given in this section while setting up the Findenser.
- Label all points where surface temperatures above 50 °C can be reached, using the legally required warnig signs.
- Findenser may be used with a wide range of reaction vessels (round bottomed, pear shaped or florentine).
- Select your hotplate and site on a level surface in your fumehood, ensuring there is adequate working space around it. It is important to maximise airflow around Findenser to allow heat transfer from the fins via air convection.
- If applicable, select an appropriate heating block for your application and position it on the hotplate stirrer.
- Put the vessel into the heating block or position it on the hotplate stirrer.
- Once in the heating block the vessel must be securely clamped around the central neck and attached to a support framework.
- Add all reaction contents and magnetic stirrer bar to the flask. ➜ Place the cone of the Findenser into the socket of the vessel, and check that the connection is fully seated.
➜ Fix the clamp with the aid of a boss to a retort stand or rigid framework, then position the jaws around the Findenser body and tighten.
Caution: Risk of leakage
- Failure to check that the joint between the vessel and Findenser is properly seated and aligned may result in loss of solvent during the reaction process.
- Ensure that the inner surface of the socket on the vessel and the outer surface of the cone on the Findenser are clean and free of any dirt or chemical residue.
Operation
Caution: Risk of breakage
- Failure to check that the joint between the vessel and Findenser is properly seated and aligned may result in the glass cracking in either the flask or the Findenser.
- Check the alignment of the vessel and Findenser assembly, this should be completely vertical. The assembly must not be subjected to any mechanical stress.
- Only use clamps suitable for a diameter up to 85 mm. Other clamps may be used but care should be taken that the jaws of the clamp have a suitable liner (cork or plastic). Failure to observe this will result in damage to the Findenser surface.
- For optimum stability, the clamp should be positioned on the upper half of the Findenser body.
Caution: Risk of deformation
- Excessive tightening of the clamp on the Findenser aluminium body may result in damage to the fins of the Findenser.
- Clamp the Findenser without the use of tools or keys.
- Make sure that the assembly is completely vertical and stable, and check that the all connections are fully seated.
- Additional glassware such as a dropping funnel, may now be attached to the side arms if a multi-neck vessel is being used.
- If an inert gas is required, this should be added through the top joint of the Findenser with the use of a suitable right angled adapter and oil bubbler.
Operation
Please observe all instructions, notes and warnings given in this section
while using the Findenser.
- Always refer to the manufacturers operating instructions for your hotplate and heating block before use with Findenser.
- Operate only in a fumehood with protective safety sash.
- Use of Findenser in ambient temperatures greater than 24°C or in the following conditions may lead to reduced performance:
- extremely low boiling point solvents such as ether where volumes are greater than 100 ml
- heating is more than 10°C above the boiling point
- Findenser is resistant to the majority of solvents and splash-resistant to dilute acids and alkalis at room temperature.
- Extended exposure to acids or alkalis will attack the surface of the Findenser. It is important to clean off any residual chemical spills immediately after they occur.
- Once heating has started it is important to regularly monitor the reactor set up to ensure that excessive heat is not being applied.
- If boiling of solvent, or refluxing appears vigorous, then the temperature of the hotplate controller must be turned down.
Cleaning and Maintenance
Caution: Risk of damage to the Findenser
- The processing of solvents with a boling point above 155 °C may result in damage to the Findenser.
- Findenser can only be used with the full range of organic solvents, with boiling points up to 155 °C.
- If using a heating block, care should be taken to optimise the heating performance. Refer to operating instructions for your heating block.
- If attempting to work under reflux conditions it is usually necessary to set the hotplate stirrer to a temperature above the boiling point of the solvent in use. Care should be taken to minimise this temperature, such that a gentle reflux is achieved. This would typically be 5 °C to 10 °C above boiling point of the solvent in use. Failure to observe this will result in excessive heating, resulting in vigorous refluxing and a loss of solvent from the reaction mixture.
Caution: Risk of damage to the Findenser
There is a risk of escaping of solvent vapor in overloading conditions.
Please observe the following limits:
- Findenser is designed to be used with flasks up to 2 litres and a maximum solvent volume of 1 litre.
- Findenser Mini is designed to be used with flasks up to 250 ml and a maximum solvent volume of 125 ml.
Once the reaction has finished, the heat source should be switched off and the system allowed to cool to ambient temperature.
Warning: Risk of burning
- There is a risk of accidental burns caused by coming into contact with hot surfaces.
- The Findenser can get very hot during operation. Avoid skin contact and allow the Findenser to cool to ambient before dismantling.
Cleaning
Please observe all instructions, notes and warnings given in this section
while setting up the Findenser.
- Before cleaning, allow the Findenser to cool to ambient temperature and dismantle the assembly as described in section Disassembly and Storage.
- Flush the internal glass surfaces with a suitable cleaning solvent such as acetone. This is best achieved with a wash bottle.
- External exposed glass surfaces may also be cleaned with a suitable solvent.
Warning: Risk of injury
- Cleaning solution may cause skin and eye irritation.
- Use requiered personal protective equipment and observe the applicable general and safety instructions of the manufacturer.
Caution: Risk of environmental damage
- Cleaning solution may cause environmental damage.
- Always use cleaning solution with due care. Allow washing solvent to drain into a suitable receptacle. Spilled chemicals and solvents must be removed immediately.
- Wash the whole Findenser assembly in warm soapy water, using a soft brush to clean fins.
- Rinse with warm water both internally and externally.
- Allow to air dry.
- Findenser may be dried in an oven provided the over temperature does not exceed 60 °C.
Caution: Risk of failure of the product
- Drying of Findenser in a vacuum oven, or at temperatures exceeding 60 ˚C may result in damage to internal components and lead to failure.
If necessary, Findenser may be cleaned in a dishwasher. However care must be taken to limit the temperature of the wash cycle to50 °C.
Caution: Risk of failure of the product
Cleaning of Findenser in a dishwasher above 50 ˚C may result in damage to
internal components and failure of the product.
Continual exposure to dishwasher cleaning at 50 ˚C or below may result in the discolouration of the surface finish of the metal component. This will not affect the performance of the product.
Caution: Risk of failure of the product
Findenser is not suitable for cleaning in an autoclave, this will result in
damage to internal components and failure of the product.
Maintenance
The Findenser is maintenance-free.
Troubleshooting
If you experience a malfunction which can not be resolved, please contact your
authorized Heidolph Instruments distributor immediately.
Assembly
For detailed information on how to mount the Findenser, see chapter Setting up
Findenser.
Accessories and Spare Parts
Dismantling, transportation and storage
Dismantling
- Warning: Risk of scalding!
- Hot surfaces and fluids may result in scalding.
- Ensure that all parts have cooled down to room temperature prior to dismantling
The magnetic stirrer is switched off.
- Loosen the clamp on the Findenser body.
- Gently lift the Findenser vertically upwards to separate the joint between the Findenser and flask. A careful twisting motion may help to separate the joint.
- The Findenser may now be fully removed and rested on a level surface.
Transportation and storage
- Store and transport the Findenser in the original packing material or alternatively in an adequate container to prevent damage.
- Seal the package carefully against unauthorized or accidental opening.
- Store the Findenser in a dry and frost-free place.
Improper storage and transportation may result in damages to the Findenser. Avoid any kind of shocks during transportation.
Scope of delivery
Air condenser for Magnetic Stirrer
Component Product number
-
Findenser B24 Cone, B24 Socket – 400 mm
505-81700-00-0 -
Findenser B29 Cone, B24 Socket – 400 mm
505-81710-00-0 -
Findenser B19 Cone, B19 Socket – 400 mm
505-81720-00-0 -
Findenser Mini B24 Cone, B24 Socket – 275 mm
505-81800-00-0 -
Findenser Mini B19 Cone, B19 Socket – 275 mm
505-81810-00-0 -
Findenser Mini B14 Cone, B14 Socket – 275 mm
505-81820-00-0 -
Operating manual English / German
01-005-006-04-0
Accessories
Component Product number
- Findenser attachment kit (stay bar, 2 × boss head, 2 × retort clamp)
11-300-008-23-0
Additional accessories are shown in the general catalog or on our website at www.heidolph-instruments.com .
Attachments
Technical data
Technical data Findenser
- Length × Diameter 400 mm × 72 mm
- Joints B19, B24, B29
- Weight 1200 g
- Inner or wetted parts Borosilicate glass
- Finned jacket Anodised aluminium
- Plug & Seal Acetal & FKM
- Thermofluid Water
- Max solvent bpt 155 °C
- Oven drying Max Temp. 60 °C
- Dishwasher Max Temp. 50 °C
- Autoclaving Do Not Autoclave
- Ambient operating temp. 0 °C to 24 °C
Technical data Findenser Mini
- Length × Diameter 275 mm × 72 mm
- Joints B14, B19, B24
- Weight 670 g
- Inner or wetted parts Borosilicate glass
- Finned jacket Anodised aluminium
- Plug & Seal Acetal & FKM
- Thermofluid Water
- Max solvent bpt 155 °C
- Oven drying Max Temp. 60 °C
- Dishwasher Max Temp. 50 °C
- Autoclaving Do Not Autoclave
- Ambient operating temp. 0 °C to 24 °C
Contact / Technical Service
If any aspect of installation, operation or maintenance remains unanswered in
the present manual, please get in touch with the following address.
Contact details
- Heidolph Instruments Germany
- Heidolph Instruments GmbH & Co. KG
- Technical Service
- Walpersdorfer Str. 12
- D-91126 Schwabach / Germany
- Tel.: +49 – 9122 – 9920-74
- Fax: +49 – 9122 – 9920-84
- E-Mail: service@heidolph.de
- www.heidolph.com
- H eidolph Instruments North America
- Phone: 1-866-650-9604
- E-mail: service@heidolph.com
- www.heidolphNA.com
- Heidolph Instruments United Kingdom
- Phone: 01799 – 5133-20
- E-mail: service@radleys.co.uk
- www.heidolph-instruments.co.uk
- All other countries
- You will find contact details of your local Heidolph distributor at www.heidolph.com
Service
Warranty
- Heidolph Instruments provides a 3 year warranty for the products described here (excluding glass and wearing parts) if you register using the warranty card enclosed or online (www.heidolph.com).
- The warranty period begins with the date of purchase. The serial number is also valid without registration.
- This warranty covers material and manufacturing defects.
- In the event of a material or manufacturing defect, the Findenser shall be replaced free of charge under the terms of the warranty.
- Heidolph Instruments shall not assume liability for any damage incurred as a result of improper handling or transport.
Warranty claim?
Please notify Heidolph Instruments or your local Heidolph distributor if
you wish to make a warranty claim.
© Heidolph Instruments GmbH & Co. KG
Doc-ID: 01-005-006-04-1 – Ed.: 2023-01-30
Subject to change without notice. This documentation is not subject to
revision; the latest version of this documentation can be found on our
homepage. The copyright for all texts and images is held by Heidolph
Instruments GmbH & Co. KG.
References
- Heidolph EMEA - research made easy
- Heidolph Instruments : Start
- Heidolph NA - research made easy
- Heidolph NA - research made easy
- Heidolph Instruments : Service
- Heidolph Instruments : Service