FORTINET FortiAP 231FL Wireless Access Point User Guide
- June 13, 2024
- FORTINET
Table of Contents
Quick Start Guide
Forti AP 231FL
FAP-231FL
FortiAP 231FL Wireless Access Point
Before you begin
Register your device to access FortiGuard updates, cloud management, firmware
upgrades, technical support and warranty coverage.
https://support.fortinet.com
This guide covers: FAP-231 FL August 4, 2023
Copyright© 2022 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®,
FortiCare® and FortiGuard®, and certain other marks are registered trademarks
of Fortinet, Inc., in the U.S. and other jurisdictions, and other Fortinet
names herein may also be registered and/or common law trademarks of Fortinet.
All other product or company names may be trademarks of their respective
owners. Performance and other metrics contained herein were attained in
internal lab tests under ideal conditions, and actual performance and other
results may vary. Network variables, different network environments and other
conditions may affect performance results. Nothing herein represents any
binding commitment by Fortinet, and Fortinet disclaims all warranties, whether
express or implied, except to the extent Fortinet enters a binding written
contract, signed by Fortinet’s General Counsel, with a purchaser that
expressly warrants that the identified product will perform according to
certain expressly-identified performance metrics and, in such event, only the
specific performance metrics expressly identified in such binding written
contract shall be binding on Fortinet. For absolute clarity, any such warranty
will be limited to performance in the same ideal conditions as in Fortinet’s
internal lab tests. In no event does Fortinet make any commitment related to
future deliverables, features or development, and circumstances may change
such that any forward-looking statements herein are not accurate. Fortinet
disclaims in full any covenants, representations, and guarantees pursuant
hereto, whether express or implied. Fortinet reserves the right to change,
modify, transfer, or otherwise revise this publication without notice, and the
most current version of the publication shall be applicable.
For Product License Agreement / EULA and Warranty Terms, visit
https://www.fortinet.com/content/dam/fortinet/assets/leoal/EULA.pdf
The Essentials
Default Logins
| https://192.168.1.2
Username: admin
Password: leave blank
---|---
| http://fortiapcloud.com
Username: user-defined
Password: user-defined
Admin Guide
For a detailed FortiAP setup and configuration information, refer to the Admin
Guide on https://docs.fortinet.com/product/fortiap
Customer Service
For contracts, licensing, product registration and account management, contact
FortiCare Support at https://www.fortinet.com/support/contact
Self-service Resources
Access our knowledge base, forums, videos and technical experts at
https://www.fortinet.com/support/support-services/forticare-support
Thank you for choosing Fortinet
Package Contents
FortiAP 231FL
FAP-231FL
Setup Options
Power the FortiAP device with a 802.3 af/at PoE injector, FortiGate PoE port or the optional (not included) 12V 2.5A power adapter.
FortiAP Cloud
Note: Use your FortiCloud credentials to log in, then click Inventory, Import AP Key and enter the Cloud Key on the device sticker
Direct Connection
Note: To self-configure, preauthorize the FortiAP on your FortiGate Otherwise once connected, wait for the FortiAP to appear on the Managed FortiAP page in FortiOS.
Network Connection
Note: Connect to the FortiAP using 192.168.1.2 with username admin and a blank password. Specify the FortiGate IP using: cfg -a AC_IPADDR=0.0.0.0 cfg -c where 0.0.0.0 is the FortiGate IP.
Bracket Installation
The FortiAP mounts on a ceiling using the provided T-rail mounting brackets which come in two standard sizes: 1.43cm (9/16in) and 2.38cm (15/16in).
-
Select the bracket for the T-rail size: 1.43cm (9/16in) or 2.38cm (15/16in)
-
With the ports facing you, slide the bracket left to right
-
Hold the device against the ceiling T-rail and push until it snaps into place
Interfaces – FAP 231FL
-
System status LED Indicators
-
OPTIONAL POWER (12V DG) Optional 12V DG 2.5A adapter
-
RESET resats the device
-
CONSOLE (RJ-45) LI management compuiter interface
-
LAN2 GE (RU-45) 1 Gbps Ethernet interface
-
LAN1/POE GE (RU-45) 1 Gbps 802.3at PoE Ethernet interface
-
USB 3.0 (Type A) software enabled power through the GPIO, 9A/5V
Cautions and Warnings
Environmental specifications
Ambient operating temperature: 0°C to 45°C.
Refer to specific Product Model Data Sheet for Environmental Specifications
(Operating Temperature, Storage Temperature, Humidity, and Altitude).
Safety
Caution: This equipment is to be used in a Network Environment 0 per
IECTR 62101. This product is connected only to PoE networks without routing to
the outside plant.
This product is intended to be supplied by a Listed Direct Plug-In Power Unit
marked LPS or Class 2 and rated 12 Vdc, 2.5A or by 54 Vdc from PoE source.
Regulatory Notices
Federal Communication Commission (FCC) – USA
This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received; including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in
residential installation. This equipment generates, uses, and can radiate
radio frequency energy, and if it is not installed and used in accordance with
the instruction manual, it may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WARNING: Any changes or modifications to this unit not expressly approved
by the party responsible for compliance could void the user’s authority to
operate the equipment.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator and your body. This transmitter
must not be co-located or operating in conjunction with any other antenna or
transmitter.
Caution: Operation of this device is restricted to indoor use only.
For operation within 5.15 – 5.25GHz frequency range, it is restricted to
indoor environment.
This device meets all the other requirements specified in Part 15E, Section
15.407 of the FCC Rules.
Industry Canada Equipment Standard for Digital Equipment (ICES) – Canada
This Class B digital apparatus complies with Canadian ICES-003.
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Antenna Type
Antenna Connector
Antenna No| 2.4-2.4835GHz 5.180-5.825GHz
---|---
1| ChainO| 5.| 5.
2| Chain1| 4.| 6.
3| Scan| 4.0| 5.
European Conformity (CE) – EU
This is a Class B product. In a domestic environment, this product may cause
radio interference, in which case the user may be required to take adequate
measures.
The product transmits within the frequency ranges and less than or equal to
the power listed below: 2412-2472 MHz less than 20 dBm 2402-2480MHz less than
20dBm 2405-2480MHz less than 20dBm 5180-5240 MHz less than 23 dBm 5260-5320
MHz less than 23 dBm 5500-5700 MHz less than 30 dBm
Note: * Only with DFS bands certification.
This equipment should be installed and operated with minimum distance 20cm
between the radiator and your body.
Simplified EU Declaration of Conformity
This declaration is only valid for Fortinet products (including, combinations
of software, firmware and hardware) provided by Fortinet or Fortinet’s
authorized partners to the end customer directly for use within the EU or
countries that have implemented the EU Directives and/or spectrum regulation.
Any Fortinet products not obtained directly from Fortinet or Fortinet’s
authorized partners may not comply with EU Directives and Fortinet makes no
assurances for such products.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>