WALFRONT WZ3605E Digital Control Power Supply User Guide

June 13, 2024
WALFRONT

WALFRONT WZ3605E Digital Control Power Supply User Guide
WALFRONT WZ3605E Digital Control Power Supply

  • There is no communication version of this product
  • This product is adjustable power supply of DC voltage rise and fall. Please read the instructions before use. Do not con- nect AC or exceed the allowable input voltage range.

HD Color screen display

It adopts 1.44 inch high-definition color screen display and multi screen display. The output voltage is adjustable from 0.6 V to 36.00V, and the output current is adjustable from 0 to 5.000A. Small size, high precision, widely used.
HD Color screen display

Functional features

  1. Input reverse connection protection
  2. 10 data storage
  3. CV/CC
  4. Over voltage protection
  5. Over power protection
  6. Over current protection

Output multiple protections

Professional equipment calibration

Using high precision sampling chip, low tempeature drift ref- erence power supply and advanced over sampling and filterin- gAlgorithm, optimize calibration process, hang up aging test,et- c., to ensure the accuracy and stability of the productSet!
Professional equipment calibration

Multi interface display

Multi interface display

Display and operation of main interface

Display and operation of main interface

Output on/off setting

In the off state, short press ),turn on output, shour press in open state, close output.

Set output voltage/current

In the main interface, short press VI, enter the voltage setting state (reverse red display), press encoder, move and cycle the selected number one by one, rotate the rotary encoder to change the number to be large small.after adjustment, press VIA save the current data and exit.30 seconds no operation will be automat- icsign out. The passage of the same principle (A set the current quickly.

M1/M2 Data group quick call out

In the main interface, long press (VIA, data group 1 can be called out, and the lower part of the screen is displayed the column displays the data group number that has been called up. under data group 1, long press VA to return data group MO.Same as long press AM3-M9 data group in the required number call up and set according to group setting interface. Please refer to the corresponding interface setting instructions.

System zero out

In the main interface, there is a small current. Long press the rotary encoder to calibrate the output small current drift.

Interface switching

No settings are selected, and the rotary encoder switches menus.

Statistical interface display and operation

Statistical interface display and operation

Statistics run/pause

In the statistics interface, in the running state, short press the rotary encoder to pause the statistics. In pause, press the rotary encoder for a short time under the state, and the opera- tion will be counted.

Clear statistics

In the statistics interface, press and hold the rotary encoder to clear the statistical information.

Voltage current curve interface

Voltage current curve interface

Each grid represents: 0.1V/0.01A Sampling time: 1S

System setting interface

System setting interface

Enter system settings

Long press rotary encoder or short press (A) to enter system setting. The selected item will be displayed in reverse, short press VIA or A/V switch the selected entry, and then rotate the encoder to adjust the set-
ting. Set up after setting, press and hold the rotary encoder to save the exit system settings.

Data group setting interface

Data group setting interface

M-PRE: 1.Select data group MO-M9; 2. Set call out output.
U-SET: Set the output voltage value.
I-SET: Set the output current value.
S-OVP: Set the overvoltage protection value.
S-OCP: Set the overcurrent protection value.
S-OPP: Set the over power protection value.
S-OHP: Set the maximum run time (parameter is 0,closed by default)
S-OAP: Set the maximum capacity (parameter is 0,closed by default)
S-OWH: Set the maximum energy(parameter is 0,off by de- fault)

Data group setting method

Long press rotary encoder or short press (A to enter data group setting. The selected item will be reversed, short press VIA or A to switch the selected items, and then rotate the encoder to adjust the settingsSet.After setting, press and hold the rotary encoder to save and exit the set- ting.

Product information

Model:WZ3605E Display:1.44 inch Color screen
Input voltage range:6 00-36.00V Input voltage resolution:0.1V
Output voltage range:0.60-36.00V Output voltage resolution:0.01V
Output current range:0-5.000A Output current resolution:0.001A
Output power range:0-80.000W Intput voltage accuracy:±(1%+5)
Output voltage accuracy:±(0.3%+3) Output current accuracy:±(0.5%+5)
Output ripple:150mV Temperature 101C-60t
Time range:0-10000 hour(unit:S) Energy range:0-99999.999WH
Capacity range:0-99999.999AH Capacity energy error:±2%
Screen brightness:0-6 7 levels Product Size:794348mm

Including package weight: about 135g

Product mix

Product mix

Product Size

Product Size

Opening Size

Opening Size

For embedded installation, panel opening size is 75mm*39mm

Card slot size

Net weight: about 95g Height of the slot 3.34mm

Product packaging

Paper shell independent packaging

Paper shell independent packaging

Weight: about 135g (including package)

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>