ELRO FS461011 Smoke Alarm Instruction Manual

June 4, 2024
ELRO

FS461011 Smoke Alarm
Instruction Manual

ELRO FS461011 Smoke Alarm

FS461011 Smoke Alarm

FS4610 19
FS4610 DoP 001
1116 Fire Safety
EN 14604:2005 + AC:2008
Manufacturer:
Sitwell Electronics CO., Limited
No.666 Qingfeng Road, Jiangbei District,
Ningbo, Zhejiang Province, China 315034

Importer
ELRO Europe | www.elro.eu
Postbus 9607 – Box E800
1006 GC Amsterdam The Netherlands

ELRO FS461011 Smoke Alarm - Figure 1

INTENDED USE: FIRE SAFETY ESSENTIAL CHARACTERISTICS: PASSED

INTENDED USE: FIRE SAFETY
ESSENTIAL CHARACTERISTICS: PASSED

Nominal activation conditions/ Sensitivity, Response delay (response time) and Performance under fire conditions – Operational reliability – Tolerance to supply voltage -Durability of operational reliability and response delay, temperature resistance, vibration resistance, humidity resistance, corrosion resistance, electrical stability

| Smoke alarm with opal sensor
---|---
| 10 years, not replaceable
| Mounting: ceiling, wall
| Dimmed led signals in dark rooms
| Alarm silence facility
| Automatic self-test
| Mute battery warning
| Suitable for caravans
| Operating temperature
| Operating humidity
|  Alarm volume
| Capacity
| Warranty: www.elro.eu

This smoke alarm is equipped with a self-test mechanism. At least once a month at a random moment, the device automas the func
sensor and the siren. During a successful test, the detector will beep and blink briefly. If problems are detected, the detector switches to error mode. Replace the device immediately if the error message occurs!

Content

Activate

ELRO FS461011 Smoke Alarm - Figure 3

Testing

Rooms

Ceiling/Wall mounting

ELRO FS461011 Smoke Alarm - Figure 6

Test & clean

Alarm silence

ELRO FS461011 Smoke Alarm - Figure 8

Low battery

ELRO FS461011 Smoke Alarm - Figure 9

Overview LED & acoustic signaling

Operating mode| Visual signal (flash)| Acoustic signal (beep)| Description mode
---|---|---|---
Normal| 1 x per 40 second| None| The device is functioning properly
Self-test| 1 x| 1 x| Device functions correctly
Manual test| 3 x| 3 x| Device functions correctly
Alarm| 1 x per second (3 x) / pause of 1,5 seconds| 1 x per seconds (3 x) / pause of 1,5 seconds| The device is detecting smoke
Alarm silence| 1 x per 8 seconds| None| The smoke alarm signal is muted
Low battery warning| 1 x per 40 seconds| 1 x per 40 seconds| The battery is running low
Low battery warning silence| None| None| Low battery warning is muted
Sensor fault warning| 1 x per 40 seconds| 1 x per 40 seconds| Sensor is not functioning properly
Buzzer fault warning| 2 x per 40 seconds| None| A buzzer is not functioning properly

Symbols:

Recycling and disposal: The WEEE symbol means that this product and batteries must be disposed of separately from other household waste. When it reaches its end of life, take it to a designated waste collection in your area to guarantee safe disposal or recycling. Protect the environment, human health, and natural resources!
Read the manual before use and store it in a safe place for future use and maintenance.
Download Declaration Performance (DoP) at www.elro.eu.

Warnings:

  • To prevent injury, this apparatus must be securely arched to the ceiling in accordance with the installainstruc
  • Batteries shall not be exposed to excessive heat such as sunshine and fire.
  • Battery life shortens without monthly tests.
  • Keep away from air condi/ven
  • Do not paint or cover the device.
  • Consult local regula

Troubleshoot False alarm is one caused by dust or steam. In case of doubt: Leave the building and take acAddimouninstrucCorridor max width 3m: Max 15m between 2 alarms.
Max. 7,5m to front side and alarms at edges/crossings of corridors. Galleries: Length and width >2m and >16m², addialarms below gallery. Parrot slopes: Flat ceiling ≤1m wide,  consider as the roof slope. Flat ceiling >1m wide, consider as flat ceiling.