Fantini Cosmi CH180RFWIFI Flush Mounting Programmable Instructions

June 13, 2024
Fantini Cosmi

CH180RFWIFI Flush Mounting Programmable

Product Information

The CH180RFWIFI is a wireless touchscreen programmable
thermostat with WiFi connection manufactured by FANTINI COSMI
S.p.A. It is designed to allow users to manage temperature and
humidity levels in different zones within the same home. The
thermostat communicates with other devices installed in the rooms
via radio waves.

The thermostat has a display with various keys and icons to
indicate the day of the week, activation status, messages and daily
programming, room temperature and humidity, operating mode, faults,
and more. The multi-function keys have different functions
depending on the situation and are indicated by symbols on the
display.

Technical features of the thermostat include temperature
adjustment scale, measurement scale for room temperature and
relative humidity, power supply, relay contact range, software,
WiFi connection, transmission and reception frequency, electric
insulation, protection rating, and more.

Product Usage Instructions

  1. Power on the MASTER CH180RFWIFI thermostat.

  2. Include the MASTER CH180RFWIFI in the Intellicomfort+ system
    wireless network. Use the configurator (code 1590880) and follow
    the operating instructions displayed on its screen. Move the tip of
    the configurator towards the point indicated on the device to be
    configured for touch recognition.

  3. Refer to the Intellicomfort+ system installation manual for
    further details on configuring the thermostat.

  4. Once configured, use the touchscreen display to manage
    temperature and humidity levels in different zones within your
    home.

  5. View and adjust the day of the week, activation status,
    messages and daily programming, room temperature and humidity,
    operating mode, faults, and more using the keys and icons on the
    display.

  6. Refer to the symbol displayed near each multi-function key to
    understand its specific function in different situations.

INSTRUCTIONS FOR USE
CH180RFWIFI
WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT
WITH WIFI CONNECTION
FANTINI COSMI S.p.A. Via dell’Osio, 6 20049 Caleppio di Settala, Milano – ITALY Tel. +39 02 956821 | Fax +39 02 95307006 | info@fantinicosmi.it
www.fantinicosmi.it

CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
Thank you for purchasing a FANTINI COSMI S.p.A. product. Read this instructions manual carefully and always keep it handy for any consultation.
This documentation reflects the specific product features; however, due to regulatory or commercial developments, customers are advised to check for the availability of updates to this documentation on the website FANTINI COSMI S.p.A. : pdf.fantinicosmi.it
OPERATION
The CH180RFWIFI is a programmable thermostat with WiFi connection for direct control or control through APP Intelliclima + for Smartphones and Tablets of the wireless multi-zone temperature control system. It monitors the various zones in the home, communicating with the CH120RF room thermostats and the O60RF wireless radiator actuators, with the CH175 boiler actuators or zone solenoid valve. This system uses a program that allows you to set and edit as needed the temperature, humidity and time profiles for each zone. It is equipped with a room temperature and humidity sensor, also performing the function of a zone heating, cooling and humidity control, commanding the O60RF and CH175 actuators. It can also manage an auxiliary electrical device (for example an irrigation, ventilation, curtain, etc. system) with ON/OFF control through an outside CH175. It has an internal configurable relay and users can view the energy consumption of the entire system via the intuitive graphics on its white backlit, positive LCD touchscreen. CH180RFWIFI can communicate directly with 15 wireless devices (thermostats, actuators) and can manage up to 8 zones. In total, the network can be connected to a maximum of 114 devices. NOTE: wireless transmission toward other devices occurs maximum within 2 minutes.
2

CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
MULTI-ZONE SYSTEM
The multi-zone system allows users to manage different temperature and humidity levels within the same home. The values of each zone are set on the master CH180RFWIFI and modified locally by one or more devices installed inside the rooms. Communication between all the devices occurs via radio waves.
Zona 2 Zona 1

O60RF

CH120RF
CH180RFWIFI Master

O60RF Zona 3

CH175

Zona 4…8 CH120RF

O60RF
O60RF

3

CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
Once powered, the “MASTER” CH180RFWIFI must be included in the Intellicomfort+ system wireless network. This operation requires use of the configurator (code 1590880) which provides the operating instructions through its display. When requested by the message on the display, you must move the tip of the configurator toward the point indicated on the device to be configured to perform touch recognition. For further details, please see the Intellicomfort+ system installation manual.

CH180RF

CH120RF

DESCRIPTION OF DISPLAY KEYS

1590880

CH160RF

CH120RF

The first press of any touch button allows you to activate the functions of the buttons themselves and to light up the display.

12

3

8

[ HO LIDA Y ] [ JO LLY ] [ A UTO ] [ MAN ]

DA Y ZO NE
11

23.0 36RH%

9 4
5

[ O FF ]

7

OK

C O PY

M O DE DISP

PRO G ZO NE

O FF

ESC

6

1

Day of the week

2

Activation status: heating, cooling or dehumidification

3

Bar graph for viewing messages and daily programming

4

Measured room temperature (Celsius/Fahrenheit)

5

Measured humidity

6

Multi-function touch icons

7

Zone

8

Operating mode

9

Various faults icon

The function of the multi-function keys varies depending on the situation and is described by the symbol which appears on the display near the key itself.
4

CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION

TECHNICAL FEATURES
Temperature adjustment scale Measurement scale/room T display Relative humidity adjustment scale Measurement scale/room relative humidity display Power supply
Type of output
Relay contact range Type of action Software Minimum adjusting differential Thermal gradient of reference Maximum room temperature Storage temperature WIFI connection Router communication port Transmission and reception frequency Maximum radio frequency power transmitted Electric insulation Protection rating Pollution rating Pulse voltage Wall or Dimensions
Compliant with standards
ErP classification

2 – 40°C, increase 0.1°C – 50 – + 50°C 30 – 70%, increase 0.1°C 0 – 100%, increase 1% 230V 50 Hz 1 relay with potential-free change-over contact (COM/NA/NC) 3 screw terminals (closed + open) 5(3)A 250 Vca 1BU (micro connection) class A 0.3 – 5 K 4 K/h 45°C -10°C – +60°C 2.4 GHz (802.11 b/g/n) 1080 868 MHz < 10 mW Double insulation IP40 2 4000V recessed mounting 127 x 82 x 24 mm EN 60730-1 and second parts Directive 2014/53/EU (RED) ErP Class IV; 2%
[Reg. EU 811/2013 – 813/2013] Class VIII; 5% when used with O60RF actuators to
create three or more heating zones.

PACKAGE CONTENTS
1 programmable thermostat 2 screws for fixing on recessed mounting box 503 with American pipe thread 6/32UNC (approx. Ø 3.5mm) 1 quick guide
5

CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION

Summary

OPERATION …………………………………………………………… 2
MULTI-ZONE SYSTEM……………………………………………… 3
DESCRIPTION OF DISPLAY KEYS ……………………………… 4
TECHNICAL FEATURES …………………………………………… 5
PACKAGE CONTENTS ……………………………………………… 5
1 – INSTALLATION ………………………………………………….. 7
2 – ELECTRICAL CONNECTION…………………………………. 9
3 – QUICK GUIDE FOR PROGRAMMING (PROG) …………. 10
3.1 – DATE AND TIME SETTING …………………………………………..10 3.2 – WINTER/SUMMER SETTING ……………………………………….11 3.3 – HOURLY PROGRAMMING SETTING (PROFILE)………………11 3.4 – AUX1 SETTING …………………………………………………………..13 3.5 – SETTING KEYBOARD LOCK WITH PASSWORD ………………13
4 – OPERATION (MODE) …………………………………………. 15
4.1 – OPERATING PROGRAMS …………………………………………….15 4.2 – SELECTING THE OPERATING PROGRAM………………………16 4.3 – SETTING “AUTO” PROGRAM ……………………………………….17 4.4 – SETTING GENERAL “JOLLY” PROGRAM ……………………….18 4.5 – SETTING ZONE “JOLLY” PROGRAM ……………………………..18 4.6 – SETTING “AUTO” and “HOLIDAY” PROGRAM TEMPERATURE …………………………………………………………………19 4.7 – SETTING “MANUAL” and “JOLLY” PROGRAM TEMPERATURE ..19
5 – DISPLAYING PARAMETERS (DISP)……………………… 20
5.1 – SET TEMPERATURE MODE …………………………………………20 5.2 – SEASON ……………………………………………………………………20 5.3 – EXTERNAL PROBE …………………………………………………….21 5.4 – DEW POINT ……………………………………………………………….22 5.5 – HOURS OF USE………………………………………………………….22 5.6 – WIFI STATUS ……………………………………………………………..23 5.7 – RSSI …………………………………………………………………………24 5.8 – SERIAL NUMBER……………………………………………………….24 5.9 – FAULTS …………………………………………………………………….25

7.2 – DISPLAY INTENSITY …………………………………………………..26 7.3 – DAYLIGHT SAVINGS TIME……………………………………………27 7.4 – ANTIFREEZE TEMPERATURE ……………………………………..27 7.5 – RELATIVE HUMIDITY…………………………………………………..28 7.6 – RELAY FUNCTION………………………………………………………28 7.7 – ZONE NAMES…………………………………………………………….29 7.8 – OFFSET …………………………………………………………………….30 7.9 – DIFFERENTIAL MANAGEMENT……………………………………30 7.10 -OPTIMIZATION ………………………………………………………….31 7.11 – INTEGRATION ………………………………………………………….31 7.12 – CELSIUS / FAHRENHEIT……………………………………………32 7.13 – LANGUAGE ……………………………………………………………..32 7.14 – EXTERNAL PROBE …………………………………………………..33 7.15 – COOL OFF ……………………………………………………………….34 7.16 – AUX1……………………………………………………………………….35 7.17 – ZONE DEU……………………………………………………………….36 7.18 – ZONE INT ………………………………………………………………..37 7.19 – WIFI ………………………………………………………………………..38 7.20 – SLEEP …………………………………………………………………….38 7.21 – INFORMATION …………………………………………………………39 7.22 – RESETTING DEFAULT PARAMETERS………………………….39
8 – REMOTE PROGRAMMING VIA APP ……………………… 40
8.1 – WIFI ACTIVATION ……………………………………………………….40 8.2 – INSTALLATION PROCEDURE ………………………………………41
8.3 – CONNECTION PROBLEMS ………………………………………….42
9 – DISPOSAL……………………………………………………….. 43
10 – GENERAL WARRANTY CONDITIONS ………………… 43

6 – LOCK FOR SCREEN CLEANING (ESC) …………………. 25

7 – ADVANCED FUNCTIONS (PROG) ………………………… 26

7.1 – DISPLAY ON TIME………………………………………………………26

6

CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
1 – INSTALLATION
ATTENTION! Installation must be carried out by qualified personnel in compliance with the requirements concerning installation of electrical devices.
ATTENTION! Make sure that the power supply is disconnected before performing installation.
The CH180RFWIFI programmable thermostat must be wall or recess mounted, with 3 modules or round box, at a height of about 1.5 m from the floor, in a position suitable to correctly detect the room temperature.

mm

mm

mm

OK
1.5 m

NO

NO

7

CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
Pry the back panel off the body by applying pressure to the specific groove at the bottom.

1

2

Remove the insulating protection by unscrewing the specific waterproof screw.

3
LN 21 4 230V~
5(3)A 250v~

4
LN 21 4 230V~
5(3)A 250v~

Make the electrical connections (refer to the “Electrical connections” paragraph) and secure the panel to the wall with the supplied screws.

5

6

Tighten the screw shown and hook the body onto the panel on the wall.

LN 21 4 230V~
5(3)A 250v~ T45

7

8

LN 21 4 230V~

5(3)A 250v~ T45

8

CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
2 – ELECTRICAL CONNECTION
ATTENTION! Electrical connections must be made by qualified personnel.
ATTENTION! Electrical connection operations must be done with the system’s power disconnected. Electrical connections must be made referencing the following diagram.

Power supply L-N 230V
LN 230V~

Heat pump Thermoactuators

9

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

3 – QUICK GUIDE FOR PROGRAMMING (PROG)

The first time any touch key is pressed has no effect, but only activates the functions of the buttons themselves and lights up the display.
After 30 seconds of no interaction, the display goes back to the main screen.

= allows you to CONFIRM and ESC EXIT from the current screen

PROG = allows you to PROGRAM

3.1 – DATE AND TIME SETTING

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

USER PROGR

2

DATE AND TIME

WINTER

PROFILE

AUX1: ON

LOCK NO

DATE AND TIME
2s
OK ESC

DAY
3

9

MONTH

PRESS

ESC

11

YEAR

PRESS

ESC

HOUR

12:02

MIN

PRESS

ESC

12:02
PRESS ESC
ESC

Note: ESC always allows you to go back to the previous page.

2018
PRESS
ESC

10

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

3.2 – WINTER/SUMMER SETTING

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

USER PROGR

2

DATE AND TIME

WINTER

PROFILE

AUX1: ON

LOCK NO

DATE AND TIME
2s
OK ESC

WINTER

PRESS

WINTER

x1

SUMMER

PRESS ESC
ESC

3.3 – HOURLY PROGRAMMING SETTING (PROFILE)
The profiles are set based on whether WINTER or SUMMER mode was previously selected.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

USER PROGR

2

DATE AND TIME

WINTER

PROFILE

AUX1: ON

LOCK NO

DATE AND TIME
2s
OK ESC

PROFILE
PRESS
x2 OK

PRESS

3

18.0 DAY ZONE
11

OK

C O PY

Note: pressing or allows you to move within the hours.

PRESS OK
ESC

11

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

4

18.0 DAY ZONE
11

OK

C O PY

Pressing or allows you to select the profile depending on the time. SETTABLE PROFILES:
tC (comfort) = SUMMER, WINTER tE (economy) = SUMMER, WINTER tA (antifreeze) = for WINTER only OFF = for SUMMER only In winter tE < tC; in summer tC < tE.

Note: Pressing OK allows you to go to the next day.

18.0 DAY ZONE
11

OK

C O PY

18.0 DAY ZONE
21

OK

C O PY

Pressing COPY allows you to copy the temperature profile being displayed to the following day.

18.0 DAY ZONE
31

OK

C O PY

18.0 DAY ZONE
41

OK

C O PY

Pressing and holding OK allows you to go to the next zone.

ZN1 -> ZN2

ZN1 -> ZN3
PRESS OK

OK

C O PY

OK

C O PY

3s

Once you have reached DAY H (HOLIDAY), pressing OK allows you to copy the profile of the whole zone set to the next one.

18.0 DAY ZONE
H2

OK

C O PY

ZN1 -> ZN2

OK

C O PY

ZN1 -> ZN3

OK

C O PY

12

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

3.4 – AUX1 SETTING
It is possible within the multi-zone system to autonomously manage an additional ON/OFF device (for example irrigation, shutter darkening, outside lights, fan, air conditioner, etc. systems). You must have a CH175 connected to this device and it must be configured as an auxiliary AUX1 actuator.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

USER PROGR

2

DATE AND TIME

WINTER

PROFILE

AUX1: ON

LOCK NO

DATE AND TIME
2s
OK ESC

AUX1: ON

PRESS

AUX1: ON

x3

AUX1: OFF

PRESS ESC
ESC

Note: if the symbol ! appears on the screen, it means that the command was set with the hourly profile and
therefore cannot be edited on this page. To edit it, follow the instructions in paragraph 7.

3.5 – SETTING KEYBOARD LOCK WITH PASSWORD
Lets you lock the CH180RFWIFI keyboard and any CH120RF included in the network through a 3-digit numerical code. It works only once, then it must be enabled again.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

USER PROGR

DATE AND TIME

LOCK NO

2

DATE AND TIME

2s

WINTER

PROFILE

OK

AUX1: ON

LOCK NO

PRESS

LOCK NO

x4 LOCK YES

ESC

ESC

Note: selecting LOCK YES displays the OK key. Then follow the procedure described in points 3 and 4.

13

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
LOCK YES
3
OK ESC

PASSWORD

PASSWORD

PASSWORD

4

100 PRESS

110 PRESS

111 PRESS OK

OK

OK

OK

ESC

ESC

ESC

12:01 01-01-18

5

DAY

[ MAN ]

1

23.0 36RH%

OK

When the keyboard is locked, you can only press the OK key. Pressing OK allows you to enter the set password and unlock the keyboard.

Note: with the KEYBOARD LOCK WITH PASSWORD function running, the CH120RF keys connected to the MASTER CH180RFWIFI will also be locked. A blackout does not reset the password.

14

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

4 – OPERATION (MODE)
On CH180RFWIFI, it is possible to activate and display the main operating modes either for the whole system or for a single zone. To select a zone, exit from STAND-BY mode and press the ZONES key until the selected zone number is displayed. To exit from the zone, press the ESC key, or else the CH180RFWIFI will go back to the main screen after 30 seconds.

MAIN SCREEN

12:01 01-01-18

DAY

[ A UTO ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

SINGLE ZONE SCREEN

12:01 01-01-18

[ A UTO ]

23.0 DAY ZONE
12

36 RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

Note: If the LOCAL SET message appears in a zone, it means that the set-point has been changed for a finite time for the CH120RF of the indicated zone (see TEMPORARY MODIFICATION in the CH120RF manual). If WAIT appears in a zone, this means that no data relating to the selected zone has arrived after the creation of the network. Any function set from the MAIN SCREEN affects the entire multi-zone system, while any function set in a SINGLE ZONE only affects the related area.

4.1 – OPERATING PROGRAMS
The CH180RFWIFI programmable thermostat has different operating modes, called programs.

12:01 01-01-18

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

[ MAN ] MANUAL PROGRAM The device regulates room temperature using a set temperature specified on a case-by-case basis, for an unlimited amount of time until another program is selected.

12:01 01-01-18

DAY

[ A UTO ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

12:01 01-01-18

[ JO LLY ]

DAY

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

[ AUTO ] WEEKLY PROGRAM
The device manages the temperatures set based on the hourly programs on a weekly profile. You can set the following temperature levels: tC, tE, tA/ OFF (every half hour).
[ JOLLY ] TEMPORARY PROGRAM
The device manages the system using a temperature that can be set over a variable amount of time (you set the hour and the day up to when you wish to keep the set temperature).

12:01 01-01-18

[ HO LIDA Y ]

DAY
1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

[ HOLIDAY ] HOLIDAY PROGRAM The device manages the system through an extra daily profile (in the event you stay home for a holiday). You can set two temperature levels: tC, tE, tA, OFF (every half hour).

15

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

12:01 01-01-18

DAY
1
[ O FF ]

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

SYSTEM OFF or ANTIFREEZE PROGRAM Press the OFF key to switch off the system. The antifreeze temperature is maintained during WINTER mode. If the OFF key is pressed again in SYSTEM OFF mode, the system will return to the previously set operating mode.

4.2 – SELECTING THE OPERATING PROGRAM
The programs are selected in cyclical order.

12:01 01-01-18

1

DAY

[ A UTO ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

12:01 01-01-18

12:01 01-01-18

2

DAY

[ MAN ]

1

23.0 36RH%

2s

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

M O DE DISP

PRO G

ZO NE

O FF

ESC

Note: press the MODE key to select from the [MAN] – [AUTO] – [JOLLY] – [HOLIDAY] operating modes in cyclical order. If MODE is pressed from the main screen, all zones will be in the mode selected.

12:01 01-01-18

3

[ A UTO ]

DAY
1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

12:01 01-01-18

[ A UTO ]

23.0 DAY ZONE
12

36 RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

Note: press ZONE and then press MODE to set the operating mode for every single associated zone. The name of the operating mode is displayed in square brackets (e.g. [AUTO]).
Pressing the DISP key allows the user to view some parameters set based on the active operating program.

16

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

4.3 – SETTING “AUTO” PROGRAM

12:01 01-01-18

DAY

[ A UTO ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

The device manages the temperatures set based on the hourly programs on a weekly profile. You can set the following temperature levels: tC, tE, tA/ OFF (every half hour).
The CH180RFWIFI has weekly pre-set profiles in both winter and summer, but the user can edit them. See par. 3.3, page 10.

17

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

4.4 – SETTING GENERAL “JOLLY” PROGRAM
The device manages the system using a temperature that can be set over a variable amount of time (you set the hour and the day up to when you wish to keep the set temperature).
From the main screen, press MODE until JOLLY appears. The JOLLY TOT screen is displayed. Press OK and use the and arrows to set the time (with 30 min. resolution) and the day until which you want to maintain the set temperature.

JOLLY TOT

PRESS

1

OK

OK ESC

12:01 01-01-18

12:01 01-01-18

TJ = 20.0

2

PRESS

PRESS

24.2

PRESS ESC

ESC

ESC

ESC

Set the time and day until you which you want to maintain the set temperature. At the end of JOLLY mode, the programmable thermostat will return to the previously set operating status.

4.5 – SETTING ZONE “JOLLY” PROGRAM
Press ZONE to select the desired zone and then press MODE until JOLLY appears. The JOLLY screen is displayed. Press OK and use the and arrows to set the time (with 30 min. resolution) and the day until which you want to maintain the set temperature.

1
OK

JOLLY

PRESS OK
ESC

12:01 01-01-18

12:01 01-01-18

TJ = 20.0

2

ZO NE
1

PRESS
ZO NE
1

PRESS

24.2

PRESS ESC

ESC

ESC

ESC

Set the time and day until you which you want to maintain the set temperature.

18

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

4.6 – SETTING “AUTO” and “HOLIDAY” PROGRAM TEMPERATURE
If the device is in AUTO or in HOLIDAY, you can set a tCOMF (comfort temperature) and tECO (economy temperature) temperature value between 2° and 40°C.

12:01 01-01-18

1

DAY

[ A UTO ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

TCOMF = 20.1

TECO = 20.1

2

24.4

PRESS

24.4

PRESS ESC

ESC

ESC

TCOMF =T2E0C.O1(=WIN2TE0R.) 1 TCOMF =T2E0C.O1(=SUM2M0E.R)1

Note: the same procedure applies to single zones.

4.7 – SETTING “MANUAL” and “JOLLY” PROGRAM TEMPERATURE
If the device is in MAN or in JOLLY, you can set a TMAN and TJ temperature value between 2° and 40°C.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

TMAN = 20.1

2

24.4

PRESS ESC

ESC

Note: the same procedure applies to single zones.

19

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

5 – DISPLAYING PARAMETERS (DISP)
Press the DISP key to view the most significant parameters cyclically.
5.2 – SET TEMPERATURE MODE

12:01 01-01-18

1

DAY

[ A UTO ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

TCOMF = 20.1

2

24.4

ESC

Note: according to the active operating mode, the set temperature will be displayed and it will be possible to change it : · TECO ( Economi temperature ) · TCOMF ( Comfort temperature) · TA ( Antifreeze temperature) · TMAN ( Manual temperature)

5.1 – SEASON

12:01 01-01-18

1

DAY

[ A UTO ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

TCOMF = 20.1

2

24.4 TCOMF
TECO WINTER

EXT = —

HOURS OF USE ESC WIFI STATUS

RSSI

SN 00000010

FAULTS

WINTER
PRESS
x2

PRESS ESC
ESC

20

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

5.3 – EXTERNAL PROBE

12:01 01-01-18

1

DAY

[ A UTO ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

TCOMF = 20.1

EXT = —

2

24.4 TCOMF
TECO WINTER

PRESS

EXT = —

x3

HOURS OF USE ESC

WIFI STATUS

RSSI

SN 00000010

FAULTS

Note: “—” will be displayed if no external probe is present.

PRESS ESC
ESC

5.4 – DEW POINT

12:01 01-01-18

1

DAY

[ A UTO ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

TCOMF = 20.1

DEW POINT = 1 6 .2

2

24.4 TCOMF
WITH YOU TA

PRESS

WINTER EXT = —

x4
ESC

DEW POINT

HOURS OF USE

WIFI STATUS

RSSI

SN 00000010

ANOMALIES

PRESS ESC
ESC

21

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

5.5 – HOURS OF USE
The programmable thermostat records the total consumption of the heating and cooling hours.

12:01 01-01-18

1

DAY

[ A UTO ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

TCOMF = 20.1

2

24.4 TCOMF
TECO WINTER

EXT = —

HOURS OF USE ESC WIFI STATUS

RSSI

SN 00000010

FAULTS

HOURS OF USE
PRESS

x5

OK

ESC

PREVIOUS DAY
PRESS OK
ESC

Note: it is possible to vary the use statistics by PREVIOUS DAY = total operating hours on the previous day CURRENT MONTH = total operating hours in the current month PREVIOUS MONTH = total operating hours on the previous month CURRENT YEAR = total operating hours in the current year TMAX = maximum room temperature measured from the previous day TMIN = minimum room temperature measured from the previous day RESET
Press OK on the CURRENT MONTH, PREVIOUS MONTH and CURRENT YEAR screws to view a chart with the details of use (shown below).

hours of use

024 01
ESC
display day or month or year

Press or to move and view the day of the month (or month or year, depending on the page displayed) and hours of use.

22

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

5.6 – WIFI STATUS
Allows you to view the WiFi signal quality.

12:01 01-01-18

1

DAY

[ A UTO ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

TCOMF = 20.1

WIFI STATUS

2

24.4 TCOMF
TECO WINTER

PRESS

EXT = –HOURS OF USE ESC

x6

WIFI STATUS

RSSI

SN 00000010

FAULTS

080

PRESS ESC

ESC

90
EXCELLENT signal

50 – 90
GOOD signal

30 – 50
LOW signal

<30
POOR signal

Example:
WIFI STATUS = 80 = Good Signal

If the icon is: STEADY ON = status is OK FLASHING ON = device cannot find the server OFF = the device is not connected to the router (OFF will appear on the display)

23

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

5.8 – RSSI
Displays the quality of the signal received from the devices connected directly to the programmable thermostat.

12:01 01-01-18

1

DAY

[ A UTO ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

TCOMF = 20.1

2

24.4 TCOMF
TECO WINTER

EXT = —

HOURS OF USE ESC WIFI STATUS

RSSI

SN 00000010

FAULTS

RSSI
PRESS

x7

OK

THERMOSTAT

PRESS OK

220 ZONE

PRESS

1

03

ESC

ESC

ESC

THERMOSTAT

220 ZONE

1

03

zone

ESC
RSSI value

Type of associated device
Displayed device counter

THERMOSTAT = CH120RF ATT-01 = O60RF, CH175 and zone identification num. NO DEVICE = no device

5.7 – SERIAL NUMBER
Allows you to view the device serial number.

12:01 01-01-18

1

DAY

[ A UTO ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

TCOMF = 20.1

SN 00000010

2

24.4 TCOMF
TECO WINTER

PRESS

EXT = —

x8

HOURS OF USE ESC

WIFI STATUS

RSSI

SN 00000010

FAULTS

PRESS ESC
ESC

Note: this number identifies the single device and is used for WiFi activation via the “Intelliclima+” app.

24

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

5.9 – FAULTS

Allows you to view the presence of any faults on the programmable thermostat.

The flashing

icon on the display indicates that a fault is present on one of the devices making up the multi-zone

system.

12:01 01-01-18

1

DAY

[ A UTO ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

TCOMF = 20.1

2

24.4 TCOMF
TECO WINTER

EXT = —

HOURS OF USE ESC WIFI STATUS

RSSI

SN 00000010

NO FAULTS

FAULTS
PRESS

x9

OK

ERROR
020
010/ 021/ 030 022 040 001 006 050
050

DEVICE
O60RF
O60RF O60RF O60RF CH120RF CH120RF O60RF
CH175

FAULT
Incorrect assembly
Mechanical / electronic error Temperature reading error Low battery Low battery No radio communication No radio communication
No radio communication

NO FAULTS

PRESS OK

– – –

PRESS

ESC

ESC

ESC

ACTION Make sure that the head is mounted properly on the valve; contact technical support if the problem persists. Contact technical support. Contact technical support. Replace the batteries. Replace the batteries. Replace the batteries; contact technical support if the problem persists. Replace the batteries; contact technical support if the problem persists. Check the mains power supply; contact technical support if the problem persists.

6 – LOCK FOR SCREEN CLEANING (ESC)
Press ESC for 5 seconds. The message LOCKED will appear on the display for 30 seconds.

12:01 01-01-18

1

DAY

[ A UTO ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

5s

– LOCKED –

2

029

25

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7 – ADVANCED FUNCTIONS (PROG)
Press and hold the PROG key for a few seconds to access ADVANCED PROGRAMMING.
7.1 – DISPLAY ON TIME
Allows you to adjust the display backlight time (with white light) from 5 to 30 seconds (default = 5s).

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

LIGHT ON 30S

PRESS

2s

ESC

ESC

7.2 – DISPLAY INTENSITY
Allows you to modify the luminous intensity of the display on 10 levels + 0 Off (default = 5s).

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

LIGHT ON 30S

INT LIGHT 5

PRESS

PRESS

2s

ESC

x1

ESC

ESC

26

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

7.3 – DAYLIGHT SAVINGS TIME
Automatically selects the daylight saving time, applicable in European and some other countries. This allows you to automatically update the time at the time change (March and October) (default = YES).

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS

INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

LIGHT ON 30S

DAY SVNGS YES

PRESS

PRESS

2s

ESC

x2

DAY SVNGS YES

ESC

DAY SVNGS NO

ESC

7.4 – ANTIFREEZE TEMPERATURE

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS

INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

LIGHT ON 30S

TA = 5.0

2s

PRESS

23.0

PRESS ESC

x3

ESC

ESC

Note: The tA can be set from a range between 2.0 and 7.0 °C and an OFF value (default = 5.0°C). This function cannot be activated in SUMMER.

27

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

7.5 – RELATIVE HUMIDITY
This parameter allows you to set the relative humidity limit above which make a dehumidifier starts to operate.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

LIGHT ON 30S

RH = 57%

PRESS

23.0 PRESS

2s

ESC

x4

ESC

ESC

Note: this set-point value can be adjusted from 30% to 70%, or “—” not present (default = —). This function cannot be activated in WINTER.
7.6 RELAY FUNCTION
This parameter allows you to set the relay inside the programmable thermostat for various uses. The available functions are: OFF = always off because unused INT.Z.B = activation of an integration device in zone B only; INT.Z.A = activation of an integration device in zone A only; INT.Z. = activation of an integration device in zone 1 only; DEU.Z. = activation of a dehumidification unit only in zone 1 RAF.Z = activation of a cooling unit only in zone 1 RIS.Z = activation of a heating unit only in zone 1 R.R.Z. = activation of a heating and/or cooling unit only in zone 1 INT.G = activation of a general integration device; DEU.G. = activation of a general dehumidification unit RAF.G. = activation of a general cooling unit RIS.G. = activation of a general heating unit R.R.G. = activation of a general heating and/or cooling unit

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

2s

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

Note: the default setting is OFF.

LIGHT ON 30S
ESC

RELAY: OFF
PRESS
x5

PRESS ESC
ESC
28

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

7.7 – ZONE NAMES
Allows you to assign a name to each zone of the system.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

LIGHT ON 30S
2s
ESC

ZONE NAMES
PRESS

x6

OK

PRESS OK
ESC

MASTER BEDROOM 1

Press or to select the zone name. Press or to assign a number to the selected name.

3

ZO NE

1

PRESS
ESC Example: Zone 1 = MASTER BEDROOM 1

The names of the zones range between:
ESC

Master Bedroom

Guest Room

Bedroom

Foyer

Living Room

Cellar

Kitchen

Garage

Bathroom

Laundry Room

Entrance

Boiler Room

Hallway

Day-time area

Attic

Night-time area

Family Room

Floor

Closet

Zone

29

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

7.8 – OFFSET
Allows to modify the temperature measured by CH180RFWIFI and by the heads O60RF which act as zone. Due to an incorrect wall installation or assembly of the heads on radiators located in non-ideal positions (behind walls, curtains or in crannies), the sensors might not indicate the correct temperature perceived by the devices. This function corrects the measured temperature for the selected zone by ± 5.0 °C (default = 0.0 °C).

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

LIGHT ON 30S
2s
ESC

OFFSET
PRESS

x7

OK

PRESS OK
ESC

CORRECTION

3

23.0 ZONE
1

PRESS ESC

ESC

7.9 – DIFFERENTIAL MANAGEMENT
Allows you to manage the temperature difference between the OFF and ON status.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

3s

ADVAN PROGR

LIGHT ON 30S

DIFF: STD

2

LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

2s

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

PRESS
x8
ESC

Note: the differential value can be set between 0.3 and 5.0, or STD standard (default = STD).

PRESS ESC
ESC

30

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.10 – OPTIMIZATION
This function optimizes the energy consumption of the heating and / or cooling system by acting on its on and off times. Depending on the type of system installed and the differential set, the required set point temperature can be reached, minimizing energy consumption.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS

INT LIGHT 5

ITALIAN

NOW LEG SI

EXT IN: —

TA = 5.0

COOL OFF NO

UR = —

AUX1: MAN

RELE: OFF

DEU ZONES

ZONE NAMES

INT ZONES

OFFSET

WIFI: A.P.

DIFF: STD

CH180RW V1.0

ECO : OFF

RESET NO

INT. DIFF:—

LIGHT ON 30S
2s
ESC

ECO : OFF

PRESS

ECO : ON ECO : OFF

x9

PRESS ESC
ESC

7.11 – INTEGRATION
This function integrates the heating / cooling of the main system with the VMC of Fantini Cosmi (ASPIRCOMFORT PROxx models), to reach the required temperature set point more quickly. For more information read the CH193VMC manual for ASPIRCOMFORT PROxx machines. When the integration is in operation on the CH180RFWIFI the symbol of the unit of measurement used “° C” or “° F” flashes. Set AUX1 (page 35) for the activation relay.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS

INT LIGHT 5

ITALIAN

NOW LEG SI

EXT IN: —

TA = 5.0

COOL OFF NO

UR = —

AUX1: MAN

RELE: OFF

DEU ZONES

ZONE NAMES

INT ZONES

OFFSET

WIFI: A.P.

DIFF: STD

CH180RW V1.0

ECO : OFF

RESET NO

INT. DIFF:—

LIGHT ON 30S
2s
ESC

INT DIFF: —
PRESS
x10

Note: the value of the integration differential that can be set is between 0.3 and 5.0,

or standard STD (default = —).

PRESS ESC
ESC
31

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

7.12 – CELSIUS / FAHRENHEIT
Allows you to choose the set the temperature display scale between degrees Celsius and degrees Fahrenheit.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

LIGHT ON 30S

CELSIUS

2s

PRESS

CELSIUS

26.0

PRESS ESC

FAHRENHEIT

x11

ESC

ESC

Note: the default setting is Celsius.

7.13 – LANGUAGE
Allows you to choose which language to use during programming.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

2s

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

Note: the default setting is Italian.

LIGHT ON 30S
ESC

ENGLISH

PRESS
x12

ITALIANO ENGLISH PYCCK FRANCAIS ESPANOL DEUTSCH

PRESS ESC
ESC

32

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.14 – EXTERNAL PROBE
The CH180RFWIFI does not have an auxiliary input but, inside a multi-one system with at least one CH120RF, it can manage the auxiliary input of the CH120RF itself, if correctly configured (see “ANTI-CONDENSATE ADJUSTMENT” and “EXTERNAL PROBE” in the CH120RF manual). Note: in a multi-zone system only CH120RF associated to zone 2 can be configured with external probe set as remote probe for CH180RFWIFI.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

LIGHT ON 30S

EXT IN: —

PRESS

PRESS

2s

DEW

ESC

CHG 0

x13

ALR 0

ESC

ALR C

ESC

LOW

HIGH

— = action disabled
Connecting to CH120RF you can use the following functions after connecting an EC18-EC19-EC20 temperature probe: DEW = floor system condensate formation control in summer through control of the dew point (a floor probe is required). Note: with the control active, when a zone switches the cooling system off, the symbol flashes in the corresponding zone. LOW = minimum safety temperature exceeded alarm. This is a safety threshold, only active in the SUMMER season and disables the system. To activate, press OK and set the desired minimum threshold using the or keys. HIGH = maximum safety temperature exceeded alarm. This is a safety threshold, only active in the WINTER season and disables the system. To activate, press OK and set the desired minimum threshold using the or keys.
Connecting to CH120RF a voltage-free contact allows you to use the following functions: CHG O = switch-over to SUMMER mode with closed contact and WINTER mode with open contact ALR O = display of alarm message in presence of open contact ALR C = display of alarm message in presence of closed contact

33

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

7.15 – COOL OFF
Allows you to control floor system condensate formation in SUMMER without having a floor probe.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

LIGHT ON 30S

COLL OFF NO

PRESS

PRESS

2s

NO

ESC

x14

YES

ESC

ESC

If COOL OFF = YES, the CH180RFWIFI controls cooling system shut-down at the same time as dehumidifier activation (it is necessary to set a RH% threshold and the DEW function must be disabled).

Note: with the control active, when a zone switches the cooling system off, the symbol corresponding zone.

flashes in the

34

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.16 – AUX1
This parameter allows to operate the relay of CH175 associated to the programmable thermostat in different modes. The following functions are available:
PROG = sets the on/off time profile of an external utility (e.g. irrigation, yard light, etc.) in a 24-hour span; MAN = sets relay2 in manual/ ON-OFF mode, activated locally by USER PROG (see paragraph 3.4).

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

3s

ADVAN PROGR

LIGHT ON 30S

AUX1 : MAN
PRESS

2

LIGHT ON 30S CELSIUS

INT LIGHT 5 ENGLISH

2s

DAY SVNGS YES EXT IN: —

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

PROG
MAN x15
ESC ESC

AUX1 : PROG

PRESS

3

OK

OK ESC

Off
ESOCN OFF

Pressing or allows you to scroll the different time bands. Press the or arrows to switch AUX1 relay on/off.
Note: CH175 in AUX 1 mode can only be associated to the programmable thermostat CH180RFWIFI and must be configured as auxiliary actuator AUX 1.

35

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.17 – ZONE DEU
Allows to associate the zone groups (consisting of CH180RFWIFI and CH120RF) to a dehumidifier/VMC connected to a CH175. There can be 2 groups:
DEU A GROUP; DEU B GROUP

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

3s

ADVAN PROGR

LIGHT ON 30S

2

LIGHT ON 30S CELSIUS

INT LIGHT 5 ENGLISH DAY SVNGS YES EXT IN: —

2s

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

ESC

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

ZONE DEU
PRESS
x16 OK

PRESS OK
ESC

ZONE: A

3

ZO NE

1

ESC

The keys or allow you to scroll the zones in CH180RFWIFI. The or arrows associate the DEU A, DEU B group or—for each zone displayed.
Note: Only the zones with CH180RFWIFI and CH120RF are displayed. CH175 in DEU ZONE A or in DEU ZONE B can only be associated with programmable thermostat CH180RFWIFI and must be configured as auxiliary actuator DEU ZONE A or DEU ZONE B.

36

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.18 – ZONE INT
It allows you to associate groups of zones (formed by CH180RFWIFI and CH120RF) to a VMC connected to a CH175. Groups can be 2
INT GROUP A; INT GROUP B.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G

ZO NE

O FF

ESC

3s

ADVAN PROGR

2 LIGHT ON 30S CELSIUS

INT LIGHT 5

ITALIAN

NOW LEG SI

EXT IN: —

TA = 5.0

COOL OFF NO

UR = —

AUX1: MAN

RELE: OFF

DEU ZONES

ZONE NAMES

INT ZONES

OFFSET

WIFI: A.P.

DIFF: STD

CH180RW V1.0

ECO : OFF

RESET NO

INT. DIFF:—

LIGHT ON 30S
2s
ESC

ZONE INT
PRESS

x17

OK

PRESS OK
ESC

ZONA: A

3

ZO NE

1

ESC

The keys o the zones on the CH180RFWIFI scroll. The arrows o they associate the INT A, INT B or — group for each displayed zone. Note: Only the zones with CH180RFWIFI and CH120RF are displayed. CH175 in INT ZONE A or INT ZONE B mode can only be associated with the chronothermostat CH180RFWIFI and the INT ZONE A or INT ZONE B auxiliary actuator must be configured.

37

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

7.19 – WIFI
Displays device WiFi connection status.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

3s

ADVAN PROGR

LIGHT ON 30S

WIFI: A.P.

2

LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

2s

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

PRESS

x18 NORM.

ESC

A.P.

— = off NORM. = normal A.P. = access point (allows you to connect a smartphone)

PRESS ESC
ESC

7.20 – SLEEP
It allows to set the entire heating system in the “energy saving” mode. This function is displayed with [OFF] both in the main screen and in all zones. NOTE: to restart the system it is compulsory to set a new functioning mode ONLY from the main screen or from the Intelliclima+ APP. To allow the system functioning completely, it could be necessary to wait up to 8 hours maximum.

12:01 01-01-18

LIGHT ON 30S

1

DAY

[ MAN ]

1

23.0 36RH%

2s

M O DE DISP

PRO G ZO NE

O FF

ESC

ESC

3s

SLEEP : OFF
PRESS
OFF ON x19

ADVAN PROGR

2

LIGHT ON 30S CELSIUS

INT LIGHT 5

ITALIAN

NOW LEG SI

EXT IN: —

TA = 5.0

COOL OFF NO

UR = —

AUX1: MAN

RELE: OFF

DEU ZONES

ZONE NAMES

INT ZONES

OFFSET

WIFI: A.P.

DIFF: STD

SLEEP : OFF

ECO : OFF

CH180RW V1.0

INT. DIFF:—

RESET NO

PRESS ESC
ESC

38

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT

7.21 – INFORMATION
Displays the software version of the programmable thermostat.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

LIGHT ON 30S

CH180RW V1.0

PRESS

PRESS

2s

ESC

x20

ESC

ESC

7.22 – RESETTING DEFAULT PARAMETERS
Allows you to reset all parameters (except the date and time) to the factory settings.

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

3s

ADVAN PROGR

2

LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

LIGHT ON 30S
2s
ESC

RESET NO
PRESS
NO YES x21

RESET YES
3
OK

PRESS OK
ESC

PRESS ESC
ESC

39

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
8 – REMOTE PROGRAMMING VIA APP
The WiFi signal on the programmable thermostat allows you to remotely control the device via the Intelliclima+ app, available free of charge from the Google Play Store and Apple App Store.
8.1 – WIFI ACTIVATION
The programmable thermostat WiFi connection is off upon first start-up. To activate it, go to ADVANCED PROGRAMMING and follow the instructions.

Intelliclima+

12:01 01-01-18

1

DAY

[ MAN ]

1

23.0 36RH%

M O DE DISP

PRO G ZO NE

O FF

ESC

3s

ADVAN PROGR

LIGHT ON 30S

WIFI: A.P.

2

LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH

DAY SVNGS YES EXT IN: —

2s

TA = 5.0

COOL OFF NO

RH = —

AUX1: MAN

RELAY: OFF

ZONE DEU

ZONE NAMES WIFI: A.P.

OFFSET

CH180RW V1.0

DIFF: STD

RESET NO

PRESS

NORM.

x15

A.P.

ESC

PRESS ESC
ESC

— = off NORM. = normal A.P. = access point (allows you to connect a smartphone)

Select A.P. and press ESC. Start up the guided installation procedure on the app as described in the “INSTALLATION PROCEDURE” paragraph.

40

CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT 8.2 – INSTALLATION PROCEDURE

Install the app and, upon first

1

activation, create an account by

entering a user name and password.

Create a new house by pressing the

2

key. Enter the desired name and

press

.

Add the programmable thermostat

3

by pressing the key and select

CH180RFWIFI.

At the end of this procedure, the new

4

programmable thermostat will be

displayed inside the home.

41

CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION 8.3 – CONNECTION PROBLEMS
If the router does not connect to the server: 1. Check that the router password is correct, repeating the steps in paragraphs 8.1 and 8.2; 2. Check that the router supports standard 802.11 b/g/n; 3. Contact your Internet provider and have port 1080 opened at the IP address of the server: 92.48.107.8
42

CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION 9 – DISPOSAL
The symbol of the crossed-out wheeled bin indicates that the products must be collected and disposed of separately from household waste. The batteries and integrated accumulators may be disposed of together with the product. They will be separated at the recycling facilities. A black bar indicates that the product was placed on the market after August 13th, 2005. Participating in the separate collection of products and batteries contributes to the correct disposal of these materials and therefore avoids possible negative consequences for the environment and human health. For more detailed information on the collection and recycling programmes available in your country, contact the local authorities or the sales point where you purchased the product.
10 – GENERAL WARRANTY CONDITIONS
The conventional warranty lasts 24 months, starting from the date the equipment is installed. The warranty covers all parts of the equipment, with the exception of those subjected to normal wear.
43

EN79898C- 04/2022

FANTINI COSMI S.p.A. Via dell’Osio, 6 20049 Caleppio di Settala, Milano – ITALY Tel. +39 02 956821 | Fax +39 02 95307006 | info@fantinicosmi.it
www.fantinicosmi.it

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals