CH180RFWIFI Flush Mounting Programmable
Product Information
The CH180RFWIFI is a wireless touchscreen programmable
thermostat with WiFi connection manufactured by FANTINI COSMI
S.p.A. It is designed to allow users to manage temperature and
humidity levels in different zones within the same home. The
thermostat communicates with other devices installed in the rooms
via radio waves.
The thermostat has a display with various keys and icons to
indicate the day of the week, activation status, messages and daily
programming, room temperature and humidity, operating mode, faults,
and more. The multi-function keys have different functions
depending on the situation and are indicated by symbols on the
display.
Technical features of the thermostat include temperature
adjustment scale, measurement scale for room temperature and
relative humidity, power supply, relay contact range, software,
WiFi connection, transmission and reception frequency, electric
insulation, protection rating, and more.
Product Usage Instructions
-
Power on the MASTER CH180RFWIFI thermostat.
-
Include the MASTER CH180RFWIFI in the Intellicomfort+ system
wireless network. Use the configurator (code 1590880) and follow
the operating instructions displayed on its screen. Move the tip of
the configurator towards the point indicated on the device to be
configured for touch recognition. -
Refer to the Intellicomfort+ system installation manual for
further details on configuring the thermostat. -
Once configured, use the touchscreen display to manage
temperature and humidity levels in different zones within your
home. -
View and adjust the day of the week, activation status,
messages and daily programming, room temperature and humidity,
operating mode, faults, and more using the keys and icons on the
display. -
Refer to the symbol displayed near each multi-function key to
understand its specific function in different situations.
INSTRUCTIONS FOR USE
CH180RFWIFI
WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT
WITH WIFI CONNECTION
FANTINI COSMI S.p.A. Via dell’Osio, 6 20049 Caleppio di Settala, Milano –
ITALY Tel. +39 02 956821 | Fax +39 02 95307006 | info@fantinicosmi.it
www.fantinicosmi.it
CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
Thank you for purchasing a FANTINI COSMI S.p.A. product. Read this
instructions manual carefully and always keep it handy for any consultation.
This documentation reflects the specific product features; however, due to
regulatory or commercial developments, customers are advised to check for the
availability of updates to this documentation on the website FANTINI COSMI
S.p.A. : pdf.fantinicosmi.it
OPERATION
The CH180RFWIFI is a programmable thermostat with WiFi connection for direct
control or control through APP Intelliclima + for Smartphones and Tablets of
the wireless multi-zone temperature control system. It monitors the various
zones in the home, communicating with the CH120RF room thermostats and the
O60RF wireless radiator actuators, with the CH175 boiler actuators or zone
solenoid valve. This system uses a program that allows you to set and edit as
needed the temperature, humidity and time profiles for each zone. It is
equipped with a room temperature and humidity sensor, also performing the
function of a zone heating, cooling and humidity control, commanding the O60RF
and CH175 actuators. It can also manage an auxiliary electrical device (for
example an irrigation, ventilation, curtain, etc. system) with ON/OFF control
through an outside CH175. It has an internal configurable relay and users can
view the energy consumption of the entire system via the intuitive graphics on
its white backlit, positive LCD touchscreen. CH180RFWIFI can communicate
directly with 15 wireless devices (thermostats, actuators) and can manage up
to 8 zones. In total, the network can be connected to a maximum of 114
devices. NOTE: wireless transmission toward other devices occurs maximum
within 2 minutes.
2
CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
MULTI-ZONE SYSTEM
The multi-zone system allows users to manage different temperature and
humidity levels within the same home. The values of each zone are set on the
master CH180RFWIFI and modified locally by one or more devices installed
inside the rooms. Communication between all the devices occurs via radio
waves.
Zona 2 Zona 1
O60RF
CH120RF
CH180RFWIFI Master
O60RF Zona 3
CH175
Zona 4…8 CH120RF
O60RF
O60RF
3
CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
Once powered, the “MASTER” CH180RFWIFI must be included in the Intellicomfort+
system wireless network. This operation requires use of the configurator (code
1590880) which provides the operating instructions through its display. When
requested by the message on the display, you must move the tip of the
configurator toward the point indicated on the device to be configured to
perform touch recognition. For further details, please see the Intellicomfort+
system installation manual.
CH180RF
CH120RF
DESCRIPTION OF DISPLAY KEYS
1590880
CH160RF
CH120RF
The first press of any touch button allows you to activate the functions of the buttons themselves and to light up the display.
12
3
8
[ HO LIDA Y ] [ JO LLY ] [ A UTO ] [ MAN ]
DA Y ZO NE
11
23.0 36RH%
9 4
5
[ O FF ]
7
OK
C O PY
M O DE DISP
PRO G ZO NE
O FF
ESC
6
1
Day of the week
2
Activation status: heating, cooling or dehumidification
3
Bar graph for viewing messages and daily programming
4
Measured room temperature (Celsius/Fahrenheit)
5
Measured humidity
6
Multi-function touch icons
7
Zone
8
Operating mode
9
Various faults icon
The function of the multi-function keys varies depending on the situation and
is described by the symbol which appears on the display near the key itself.
4
CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
TECHNICAL FEATURES
Temperature adjustment scale Measurement scale/room T display Relative
humidity adjustment scale Measurement scale/room relative humidity display
Power supply
Type of output
Relay contact range Type of action Software Minimum adjusting differential
Thermal gradient of reference Maximum room temperature Storage temperature
WIFI connection Router communication port Transmission and reception frequency
Maximum radio frequency power transmitted Electric insulation Protection
rating Pollution rating Pulse voltage Wall or Dimensions
Compliant with standards
ErP classification
2 – 40°C, increase 0.1°C – 50 – + 50°C 30 – 70%, increase 0.1°C 0 – 100%,
increase 1% 230V 50 Hz 1 relay with potential-free change-over contact
(COM/NA/NC) 3 screw terminals (closed + open) 5(3)A 250 Vca 1BU (micro
connection) class A 0.3 – 5 K 4 K/h 45°C -10°C – +60°C 2.4 GHz (802.11 b/g/n)
1080 868 MHz < 10 mW Double insulation IP40 2 4000V recessed mounting 127 x 82
x 24 mm EN 60730-1 and second parts Directive 2014/53/EU (RED) ErP Class IV;
2%
[Reg. EU 811/2013 – 813/2013] Class VIII; 5% when used with O60RF actuators to
create three or more heating zones.
PACKAGE CONTENTS
1 programmable thermostat 2 screws for fixing on recessed mounting box 503
with American pipe thread 6/32UNC (approx. Ø 3.5mm) 1 quick guide
5
CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
Summary
OPERATION …………………………………………………………… 2
MULTI-ZONE SYSTEM……………………………………………… 3
DESCRIPTION OF DISPLAY KEYS ……………………………… 4
TECHNICAL FEATURES …………………………………………… 5
PACKAGE CONTENTS ……………………………………………… 5
1 – INSTALLATION ………………………………………………….. 7
2 – ELECTRICAL CONNECTION…………………………………. 9
3 – QUICK GUIDE FOR PROGRAMMING (PROG) …………. 10
3.1 – DATE AND TIME SETTING …………………………………………..10 3.2 – WINTER/SUMMER SETTING
……………………………………….11 3.3 – HOURLY PROGRAMMING SETTING (PROFILE)………………11 3.4 –
AUX1 SETTING …………………………………………………………..13 3.5 – SETTING KEYBOARD LOCK WITH
PASSWORD ………………13
4 – OPERATION (MODE) …………………………………………. 15
4.1 – OPERATING PROGRAMS …………………………………………….15 4.2 – SELECTING THE OPERATING
PROGRAM………………………16 4.3 – SETTING “AUTO” PROGRAM ……………………………………….17 4.4 –
SETTING GENERAL “JOLLY” PROGRAM ……………………….18 4.5 – SETTING ZONE “JOLLY”
PROGRAM ……………………………..18 4.6 – SETTING “AUTO” and “HOLIDAY” PROGRAM TEMPERATURE
…………………………………………………………………19 4.7 – SETTING “MANUAL” and “JOLLY” PROGRAM
TEMPERATURE ..19
5 – DISPLAYING PARAMETERS (DISP)……………………… 20
5.1 – SET TEMPERATURE MODE …………………………………………20 5.2 – SEASON
……………………………………………………………………20 5.3 – EXTERNAL PROBE …………………………………………………….21 5.4
– DEW POINT ……………………………………………………………….22 5.5 – HOURS OF
USE………………………………………………………….22 5.6 – WIFI STATUS ……………………………………………………………..23 5.7
– RSSI …………………………………………………………………………24 5.8 – SERIAL
NUMBER……………………………………………………….24 5.9 – FAULTS …………………………………………………………………….25
7.2 – DISPLAY INTENSITY …………………………………………………..26 7.3 – DAYLIGHT SAVINGS
TIME……………………………………………27 7.4 – ANTIFREEZE TEMPERATURE ……………………………………..27 7.5 –
RELATIVE HUMIDITY…………………………………………………..28 7.6 – RELAY
FUNCTION………………………………………………………28 7.7 – ZONE NAMES…………………………………………………………….29 7.8
– OFFSET …………………………………………………………………….30 7.9 – DIFFERENTIAL
MANAGEMENT……………………………………30 7.10 -OPTIMIZATION ………………………………………………………….31 7.11 –
INTEGRATION ………………………………………………………….31 7.12 – CELSIUS /
FAHRENHEIT……………………………………………32 7.13 – LANGUAGE ……………………………………………………………..32 7.14
– EXTERNAL PROBE …………………………………………………..33 7.15 – COOL OFF
……………………………………………………………….34 7.16 – AUX1……………………………………………………………………….35 7.17 –
ZONE DEU……………………………………………………………….36 7.18 – ZONE INT
………………………………………………………………..37 7.19 – WIFI ………………………………………………………………………..38 7.20
– SLEEP …………………………………………………………………….38 7.21 – INFORMATION
…………………………………………………………39 7.22 – RESETTING DEFAULT PARAMETERS………………………….39
8 – REMOTE PROGRAMMING VIA APP ……………………… 40
8.1 – WIFI ACTIVATION ……………………………………………………….40 8.2 – INSTALLATION PROCEDURE
………………………………………41
8.3 – CONNECTION PROBLEMS ………………………………………….42
9 – DISPOSAL……………………………………………………….. 43
10 – GENERAL WARRANTY CONDITIONS ………………… 43
6 – LOCK FOR SCREEN CLEANING (ESC) …………………. 25
7 – ADVANCED FUNCTIONS (PROG) ………………………… 26
7.1 – DISPLAY ON TIME………………………………………………………26
6
CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
1 – INSTALLATION
ATTENTION! Installation must be carried out by qualified personnel in
compliance with the requirements concerning installation of electrical
devices.
ATTENTION! Make sure that the power supply is disconnected before performing
installation.
The CH180RFWIFI programmable thermostat must be wall or recess mounted, with 3
modules or round box, at a height of about 1.5 m from the floor, in a position
suitable to correctly detect the room temperature.
mm
mm
mm
OK
1.5 m
NO
NO
7
CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
Pry the back panel off the body by applying pressure to the specific groove at
the bottom.
1
2
Remove the insulating protection by unscrewing the specific waterproof screw.
3
LN 21 4 230V~
5(3)A 250v~
4
LN 21 4 230V~
5(3)A 250v~
Make the electrical connections (refer to the “Electrical connections” paragraph) and secure the panel to the wall with the supplied screws.
5
6
Tighten the screw shown and hook the body onto the panel on the wall.
LN 21 4 230V~
5(3)A 250v~ T45
7
8
LN 21 4 230V~
5(3)A 250v~ T45
8
CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
2 – ELECTRICAL CONNECTION
ATTENTION! Electrical connections must be made by qualified personnel.
ATTENTION! Electrical connection operations must be done with the system’s
power disconnected. Electrical connections must be made referencing the
following diagram.
Power supply L-N 230V
LN 230V~
Heat pump Thermoactuators
9
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
3 – QUICK GUIDE FOR PROGRAMMING (PROG)
The first time any touch key is pressed has no effect, but only activates the
functions of the buttons themselves and lights up the display.
After 30 seconds of no interaction, the display goes back to the main screen.
= allows you to CONFIRM and ESC EXIT from the current screen
PROG = allows you to PROGRAM
3.1 – DATE AND TIME SETTING
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
USER PROGR
2
DATE AND TIME
WINTER
PROFILE
AUX1: ON
LOCK NO
DATE AND TIME
2s
OK ESC
DAY
3
9
MONTH
PRESS
ESC
11
YEAR
PRESS
ESC
HOUR
12:02
MIN
PRESS
ESC
12:02
PRESS ESC
ESC
Note: ESC always allows you to go back to the previous page.
2018
PRESS
ESC
10
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
3.2 – WINTER/SUMMER SETTING
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
USER PROGR
2
DATE AND TIME
WINTER
PROFILE
AUX1: ON
LOCK NO
DATE AND TIME
2s
OK ESC
WINTER
PRESS
WINTER
x1
SUMMER
PRESS ESC
ESC
3.3 – HOURLY PROGRAMMING SETTING (PROFILE)
The profiles are set based on whether WINTER or SUMMER mode was previously
selected.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
USER PROGR
2
DATE AND TIME
WINTER
PROFILE
AUX1: ON
LOCK NO
DATE AND TIME
2s
OK ESC
PROFILE
PRESS
x2 OK
PRESS
3
18.0 DAY ZONE
11
OK
C O PY
Note: pressing or allows you to move within the hours.
PRESS OK
ESC
11
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
4
18.0 DAY ZONE
11
OK
C O PY
Pressing or allows you to select the profile depending on the time. SETTABLE
PROFILES:
tC (comfort) = SUMMER, WINTER tE (economy) = SUMMER, WINTER tA (antifreeze) =
for WINTER only OFF = for SUMMER only In winter tE < tC; in summer tC < tE.
Note: Pressing OK allows you to go to the next day.
18.0 DAY ZONE
11
OK
C O PY
18.0 DAY ZONE
21
OK
C O PY
Pressing COPY allows you to copy the temperature profile being displayed to the following day.
18.0 DAY ZONE
31
OK
C O PY
18.0 DAY ZONE
41
OK
C O PY
Pressing and holding OK allows you to go to the next zone.
ZN1 -> ZN2
ZN1 -> ZN3
PRESS OK
OK
C O PY
OK
C O PY
3s
Once you have reached DAY H (HOLIDAY), pressing OK allows you to copy the profile of the whole zone set to the next one.
18.0 DAY ZONE
H2
OK
C O PY
ZN1 -> ZN2
OK
C O PY
ZN1 -> ZN3
OK
C O PY
12
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
3.4 – AUX1 SETTING
It is possible within the multi-zone system to autonomously manage an
additional ON/OFF device (for example irrigation, shutter darkening, outside
lights, fan, air conditioner, etc. systems). You must have a CH175 connected
to this device and it must be configured as an auxiliary AUX1 actuator.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
USER PROGR
2
DATE AND TIME
WINTER
PROFILE
AUX1: ON
LOCK NO
DATE AND TIME
2s
OK ESC
AUX1: ON
PRESS
AUX1: ON
x3
AUX1: OFF
PRESS ESC
ESC
Note: if the symbol ! appears on the screen, it means that the command was set
with the hourly profile and
therefore cannot be edited on this page. To edit it, follow the instructions
in paragraph 7.
3.5 – SETTING KEYBOARD LOCK WITH PASSWORD
Lets you lock the CH180RFWIFI keyboard and any CH120RF included in the network
through a 3-digit numerical code. It works only once, then it must be enabled
again.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
USER PROGR
DATE AND TIME
LOCK NO
2
DATE AND TIME
2s
WINTER
PROFILE
OK
AUX1: ON
LOCK NO
PRESS
LOCK NO
x4 LOCK YES
ESC
ESC
Note: selecting LOCK YES displays the OK key. Then follow the procedure described in points 3 and 4.
13
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
LOCK YES
3
OK ESC
PASSWORD
PASSWORD
PASSWORD
4
100 PRESS
110 PRESS
111 PRESS OK
OK
OK
OK
ESC
ESC
ESC
12:01 01-01-18
5
DAY
[ MAN ]
1
23.0 36RH%
OK
When the keyboard is locked, you can only press the OK key. Pressing OK allows you to enter the set password and unlock the keyboard.
Note: with the KEYBOARD LOCK WITH PASSWORD function running, the CH120RF keys connected to the MASTER CH180RFWIFI will also be locked. A blackout does not reset the password.
14
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
4 – OPERATION (MODE)
On CH180RFWIFI, it is possible to activate and display the main operating
modes either for the whole system or for a single zone. To select a zone, exit
from STAND-BY mode and press the ZONES key until the selected zone number is
displayed. To exit from the zone, press the ESC key, or else the CH180RFWIFI
will go back to the main screen after 30 seconds.
MAIN SCREEN
12:01 01-01-18
DAY
[ A UTO ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
SINGLE ZONE SCREEN
12:01 01-01-18
[ A UTO ]
23.0 DAY ZONE
12
36 RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
Note: If the LOCAL SET message appears in a zone, it means that the set-point has been changed for a finite time for the CH120RF of the indicated zone (see TEMPORARY MODIFICATION in the CH120RF manual). If WAIT appears in a zone, this means that no data relating to the selected zone has arrived after the creation of the network. Any function set from the MAIN SCREEN affects the entire multi-zone system, while any function set in a SINGLE ZONE only affects the related area.
4.1 – OPERATING PROGRAMS
The CH180RFWIFI programmable thermostat has different operating modes, called
programs.
12:01 01-01-18
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
[ MAN ] MANUAL PROGRAM The device regulates room temperature using a set temperature specified on a case-by-case basis, for an unlimited amount of time until another program is selected.
12:01 01-01-18
DAY
[ A UTO ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
12:01 01-01-18
[ JO LLY ]
DAY
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
[ AUTO ] WEEKLY PROGRAM
The device manages the temperatures set based on the hourly programs on a
weekly profile. You can set the following temperature levels: tC, tE, tA/ OFF
(every half hour).
[ JOLLY ] TEMPORARY PROGRAM
The device manages the system using a temperature that can be set over a
variable amount of time (you set the hour and the day up to when you wish to
keep the set temperature).
12:01 01-01-18
[ HO LIDA Y ]
DAY
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
[ HOLIDAY ] HOLIDAY PROGRAM The device manages the system through an extra daily profile (in the event you stay home for a holiday). You can set two temperature levels: tC, tE, tA, OFF (every half hour).
15
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
12:01 01-01-18
DAY
1
[ O FF ]
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
SYSTEM OFF or ANTIFREEZE PROGRAM Press the OFF key to switch off the system. The antifreeze temperature is maintained during WINTER mode. If the OFF key is pressed again in SYSTEM OFF mode, the system will return to the previously set operating mode.
4.2 – SELECTING THE OPERATING PROGRAM
The programs are selected in cyclical order.
12:01 01-01-18
1
DAY
[ A UTO ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
12:01 01-01-18
12:01 01-01-18
2
DAY
[ MAN ]
1
23.0 36RH%
2s
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
M O DE DISP
PRO G
ZO NE
O FF
ESC
Note: press the MODE key to select from the [MAN] – [AUTO] – [JOLLY] – [HOLIDAY] operating modes in cyclical order. If MODE is pressed from the main screen, all zones will be in the mode selected.
12:01 01-01-18
3
[ A UTO ]
DAY
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
12:01 01-01-18
[ A UTO ]
23.0 DAY ZONE
12
36 RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
Note: press ZONE and then press MODE to set the operating mode for every
single associated zone. The name of the operating mode is displayed in square
brackets (e.g. [AUTO]).
Pressing the DISP key allows the user to view some parameters set based on the
active operating program.
16
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
4.3 – SETTING “AUTO” PROGRAM
12:01 01-01-18
DAY
[ A UTO ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
The device manages the temperatures set based on the hourly programs on a
weekly profile. You can set the following temperature levels: tC, tE, tA/ OFF
(every half hour).
The CH180RFWIFI has weekly pre-set profiles in both winter and summer, but the
user can edit them. See par. 3.3, page 10.
17
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
4.4 – SETTING GENERAL “JOLLY” PROGRAM
The device manages the system using a temperature that can be set over a
variable amount of time (you set the hour and the day up to when you wish to
keep the set temperature).
From the main screen, press MODE until JOLLY appears. The JOLLY TOT screen is
displayed. Press OK and use the and arrows to set the time (with 30 min.
resolution) and the day until which you want to maintain the set temperature.
JOLLY TOT
PRESS
1
OK
OK ESC
12:01 01-01-18
12:01 01-01-18
TJ = 20.0
2
PRESS
PRESS
24.2
PRESS ESC
ESC
ESC
ESC
Set the time and day until you which you want to maintain the set temperature. At the end of JOLLY mode, the programmable thermostat will return to the previously set operating status.
4.5 – SETTING ZONE “JOLLY” PROGRAM
Press ZONE to select the desired zone and then press MODE until JOLLY appears.
The JOLLY screen is displayed. Press OK and use the and arrows to set the time
(with 30 min. resolution) and the day until which you want to maintain the set
temperature.
1
OK
JOLLY
PRESS OK
ESC
12:01 01-01-18
12:01 01-01-18
TJ = 20.0
2
ZO NE
1
PRESS
ZO NE
1
PRESS
24.2
PRESS ESC
ESC
ESC
ESC
Set the time and day until you which you want to maintain the set temperature.
18
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
4.6 – SETTING “AUTO” and “HOLIDAY” PROGRAM TEMPERATURE
If the device is in AUTO or in HOLIDAY, you can set a tCOMF (comfort
temperature) and tECO (economy temperature) temperature value between 2° and
40°C.
12:01 01-01-18
1
DAY
[ A UTO ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
TCOMF = 20.1
TECO = 20.1
2
24.4
PRESS
24.4
PRESS ESC
ESC
ESC
TCOMF =T2E0C.O1(=WIN2TE0R.) 1 TCOMF =T2E0C.O1(=SUM2M0E.R)1
Note: the same procedure applies to single zones.
4.7 – SETTING “MANUAL” and “JOLLY” PROGRAM TEMPERATURE
If the device is in MAN or in JOLLY, you can set a TMAN and TJ temperature
value between 2° and 40°C.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
TMAN = 20.1
2
24.4
PRESS ESC
ESC
Note: the same procedure applies to single zones.
19
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
5 – DISPLAYING PARAMETERS (DISP)
Press the DISP key to view the most significant parameters cyclically.
5.2 – SET TEMPERATURE MODE
12:01 01-01-18
1
DAY
[ A UTO ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
TCOMF = 20.1
2
24.4
ESC
Note: according to the active operating mode, the set temperature will be displayed and it will be possible to change it : · TECO ( Economi temperature ) · TCOMF ( Comfort temperature) · TA ( Antifreeze temperature) · TMAN ( Manual temperature)
5.1 – SEASON
12:01 01-01-18
1
DAY
[ A UTO ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
TCOMF = 20.1
2
24.4 TCOMF
TECO WINTER
EXT = —
HOURS OF USE ESC WIFI STATUS
RSSI
SN 00000010
FAULTS
WINTER
PRESS
x2
PRESS ESC
ESC
20
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
5.3 – EXTERNAL PROBE
12:01 01-01-18
1
DAY
[ A UTO ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
TCOMF = 20.1
EXT = —
2
24.4 TCOMF
TECO WINTER
PRESS
EXT = —
x3
HOURS OF USE ESC
WIFI STATUS
RSSI
SN 00000010
FAULTS
Note: “—” will be displayed if no external probe is present.
PRESS ESC
ESC
5.4 – DEW POINT
12:01 01-01-18
1
DAY
[ A UTO ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
TCOMF = 20.1
DEW POINT = 1 6 .2
2
24.4 TCOMF
WITH YOU TA
PRESS
WINTER EXT = —
x4
ESC
DEW POINT
HOURS OF USE
WIFI STATUS
RSSI
SN 00000010
ANOMALIES
PRESS ESC
ESC
21
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
5.5 – HOURS OF USE
The programmable thermostat records the total consumption of the heating and
cooling hours.
12:01 01-01-18
1
DAY
[ A UTO ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
TCOMF = 20.1
2
24.4 TCOMF
TECO WINTER
EXT = —
HOURS OF USE ESC WIFI STATUS
RSSI
SN 00000010
FAULTS
HOURS OF USE
PRESS
x5
OK
ESC
PREVIOUS DAY
PRESS OK
ESC
Note: it is possible to vary the use statistics by PREVIOUS DAY = total
operating hours on the previous day CURRENT MONTH = total operating hours in
the current month PREVIOUS MONTH = total operating hours on the previous month
CURRENT YEAR = total operating hours in the current year TMAX = maximum room
temperature measured from the previous day TMIN = minimum room temperature
measured from the previous day RESET
Press OK on the CURRENT MONTH, PREVIOUS MONTH and CURRENT YEAR screws to view
a chart with the details of use (shown below).
hours of use
024 01
ESC
display day or month or year
Press or to move and view the day of the month (or month or year, depending on the page displayed) and hours of use.
22
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
5.6 – WIFI STATUS
Allows you to view the WiFi signal quality.
12:01 01-01-18
1
DAY
[ A UTO ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
TCOMF = 20.1
WIFI STATUS
2
24.4 TCOMF
TECO WINTER
PRESS
EXT = –HOURS OF USE ESC
x6
WIFI STATUS
RSSI
SN 00000010
FAULTS
080
PRESS ESC
ESC
90
EXCELLENT signal
50 – 90
GOOD signal
30 – 50
LOW signal
<30
POOR signal
Example:
WIFI STATUS = 80 = Good Signal
If the icon is: STEADY ON = status is OK FLASHING ON = device cannot find the server OFF = the device is not connected to the router (OFF will appear on the display)
23
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
5.8 – RSSI
Displays the quality of the signal received from the devices connected
directly to the programmable thermostat.
12:01 01-01-18
1
DAY
[ A UTO ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
TCOMF = 20.1
2
24.4 TCOMF
TECO WINTER
EXT = —
HOURS OF USE ESC WIFI STATUS
RSSI
SN 00000010
FAULTS
RSSI
PRESS
x7
OK
THERMOSTAT
PRESS OK
220 ZONE
PRESS
1
03
ESC
ESC
ESC
THERMOSTAT
220 ZONE
1
03
zone
ESC
RSSI value
Type of associated device
Displayed device counter
THERMOSTAT = CH120RF ATT-01 = O60RF, CH175 and zone identification num. NO DEVICE = no device
5.7 – SERIAL NUMBER
Allows you to view the device serial number.
12:01 01-01-18
1
DAY
[ A UTO ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
TCOMF = 20.1
SN 00000010
2
24.4 TCOMF
TECO WINTER
PRESS
EXT = —
x8
HOURS OF USE ESC
WIFI STATUS
RSSI
SN 00000010
FAULTS
PRESS ESC
ESC
Note: this number identifies the single device and is used for WiFi activation via the “Intelliclima+” app.
24
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
5.9 – FAULTS
Allows you to view the presence of any faults on the programmable thermostat.
The flashing
icon on the display indicates that a fault is present on one of the devices making up the multi-zone
system.
12:01 01-01-18
1
DAY
[ A UTO ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
TCOMF = 20.1
2
24.4 TCOMF
TECO WINTER
EXT = —
HOURS OF USE ESC WIFI STATUS
RSSI
SN 00000010
NO FAULTS
FAULTS
PRESS
x9
OK
ERROR
020
010/ 021/ 030 022 040 001 006 050
050
DEVICE
O60RF
O60RF O60RF O60RF CH120RF CH120RF O60RF
CH175
FAULT
Incorrect assembly
Mechanical / electronic error Temperature reading error Low battery Low
battery No radio communication No radio communication
No radio communication
NO FAULTS
PRESS OK
– – –
PRESS
ESC
ESC
ESC
ACTION Make sure that the head is mounted properly on the valve; contact technical support if the problem persists. Contact technical support. Contact technical support. Replace the batteries. Replace the batteries. Replace the batteries; contact technical support if the problem persists. Replace the batteries; contact technical support if the problem persists. Check the mains power supply; contact technical support if the problem persists.
6 – LOCK FOR SCREEN CLEANING (ESC)
Press ESC for 5 seconds. The message LOCKED will appear on the display for 30
seconds.
12:01 01-01-18
1
DAY
[ A UTO ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
5s
– LOCKED –
2
029
25
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7 – ADVANCED FUNCTIONS (PROG)
Press and hold the PROG key for a few seconds to access ADVANCED PROGRAMMING.
7.1 – DISPLAY ON TIME
Allows you to adjust the display backlight time (with white light) from 5 to
30 seconds (default = 5s).
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
LIGHT ON 30S
PRESS
2s
ESC
ESC
7.2 – DISPLAY INTENSITY
Allows you to modify the luminous intensity of the display on 10 levels + 0
Off (default = 5s).
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
LIGHT ON 30S
INT LIGHT 5
PRESS
PRESS
2s
ESC
x1
ESC
ESC
26
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.3 – DAYLIGHT SAVINGS TIME
Automatically selects the daylight saving time, applicable in European and
some other countries. This allows you to automatically update the time at the
time change (March and October) (default = YES).
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS
INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
LIGHT ON 30S
DAY SVNGS YES
PRESS
PRESS
2s
ESC
x2
DAY SVNGS YES
ESC
DAY SVNGS NO
ESC
7.4 – ANTIFREEZE TEMPERATURE
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS
INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
LIGHT ON 30S
TA = 5.0
2s
PRESS
23.0
PRESS ESC
x3
ESC
ESC
Note: The tA can be set from a range between 2.0 and 7.0 °C and an OFF value (default = 5.0°C). This function cannot be activated in SUMMER.
27
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.5 – RELATIVE HUMIDITY
This parameter allows you to set the relative humidity limit above which make
a dehumidifier starts to operate.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
LIGHT ON 30S
RH = 57%
PRESS
23.0 PRESS
2s
ESC
x4
ESC
ESC
Note: this set-point value can be adjusted from 30% to 70%, or “—” not present
(default = —). This function cannot be activated in WINTER.
7.6 RELAY FUNCTION
This parameter allows you to set the relay inside the programmable thermostat
for various uses. The available functions are: OFF = always off because unused
INT.Z.B = activation of an integration device in zone B only; INT.Z.A =
activation of an integration device in zone A only; INT.Z. = activation of an
integration device in zone 1 only; DEU.Z. = activation of a dehumidification
unit only in zone 1 RAF.Z = activation of a cooling unit only in zone 1 RIS.Z
= activation of a heating unit only in zone 1 R.R.Z. = activation of a heating
and/or cooling unit only in zone 1 INT.G = activation of a general integration
device; DEU.G. = activation of a general dehumidification unit RAF.G. =
activation of a general cooling unit RIS.G. = activation of a general heating
unit R.R.G. = activation of a general heating and/or cooling unit
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
2s
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
Note: the default setting is OFF.
LIGHT ON 30S
ESC
RELAY: OFF
PRESS
x5
PRESS ESC
ESC
28
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.7 – ZONE NAMES
Allows you to assign a name to each zone of the system.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
LIGHT ON 30S
2s
ESC
ZONE NAMES
PRESS
x6
OK
PRESS OK
ESC
MASTER BEDROOM 1
Press or to select the zone name. Press or to assign a number to the selected name.
3
ZO NE
1
PRESS
ESC Example: Zone 1 = MASTER BEDROOM 1
The names of the zones range between:
ESC
Master Bedroom
Guest Room
Bedroom
Foyer
Living Room
Cellar
Kitchen
Garage
Bathroom
Laundry Room
Entrance
Boiler Room
Hallway
Day-time area
Attic
Night-time area
Family Room
Floor
Closet
Zone
29
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.8 – OFFSET
Allows to modify the temperature measured by CH180RFWIFI and by the heads
O60RF which act as zone. Due to an incorrect wall installation or assembly of
the heads on radiators located in non-ideal positions (behind walls, curtains
or in crannies), the sensors might not indicate the correct temperature
perceived by the devices. This function corrects the measured temperature for
the selected zone by ± 5.0 °C (default = 0.0 °C).
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
LIGHT ON 30S
2s
ESC
OFFSET
PRESS
x7
OK
PRESS OK
ESC
CORRECTION
3
23.0 ZONE
1
PRESS ESC
ESC
7.9 – DIFFERENTIAL MANAGEMENT
Allows you to manage the temperature difference between the OFF and ON status.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
3s
ADVAN PROGR
LIGHT ON 30S
DIFF: STD
2
LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
2s
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
PRESS
x8
ESC
Note: the differential value can be set between 0.3 and 5.0, or STD standard (default = STD).
PRESS ESC
ESC
30
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.10 – OPTIMIZATION
This function optimizes the energy consumption of the heating and / or cooling
system by acting on its on and off times. Depending on the type of system
installed and the differential set, the required set point temperature can be
reached, minimizing energy consumption.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS
INT LIGHT 5
ITALIAN
NOW LEG SI
EXT IN: —
TA = 5.0
COOL OFF NO
UR = —
AUX1: MAN
RELE: OFF
DEU ZONES
ZONE NAMES
INT ZONES
OFFSET
WIFI: A.P.
DIFF: STD
CH180RW V1.0
ECO : OFF
RESET NO
INT. DIFF:—
LIGHT ON 30S
2s
ESC
ECO : OFF
PRESS
ECO : ON ECO : OFF
x9
PRESS ESC
ESC
7.11 – INTEGRATION
This function integrates the heating / cooling of the main system with the VMC
of Fantini Cosmi (ASPIRCOMFORT PROxx models), to reach the required
temperature set point more quickly. For more information read the CH193VMC
manual for ASPIRCOMFORT PROxx machines. When the integration is in operation
on the CH180RFWIFI the symbol of the unit of measurement used “° C” or “° F”
flashes. Set AUX1 (page 35) for the activation relay.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS
INT LIGHT 5
ITALIAN
NOW LEG SI
EXT IN: —
TA = 5.0
COOL OFF NO
UR = —
AUX1: MAN
RELE: OFF
DEU ZONES
ZONE NAMES
INT ZONES
OFFSET
WIFI: A.P.
DIFF: STD
CH180RW V1.0
ECO : OFF
RESET NO
INT. DIFF:—
LIGHT ON 30S
2s
ESC
INT DIFF: —
PRESS
x10
Note: the value of the integration differential that can be set is between 0.3 and 5.0,
or standard STD (default = —).
PRESS ESC
ESC
31
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.12 – CELSIUS / FAHRENHEIT
Allows you to choose the set the temperature display scale between degrees
Celsius and degrees Fahrenheit.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
LIGHT ON 30S
CELSIUS
2s
PRESS
CELSIUS
26.0
PRESS ESC
FAHRENHEIT
x11
ESC
ESC
Note: the default setting is Celsius.
7.13 – LANGUAGE
Allows you to choose which language to use during programming.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
2s
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
Note: the default setting is Italian.
LIGHT ON 30S
ESC
ENGLISH
PRESS
x12
ITALIANO ENGLISH PYCCK FRANCAIS ESPANOL DEUTSCH
PRESS ESC
ESC
32
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.14 – EXTERNAL PROBE
The CH180RFWIFI does not have an auxiliary input but, inside a multi-one
system with at least one CH120RF, it can manage the auxiliary input of the
CH120RF itself, if correctly configured (see “ANTI-CONDENSATE ADJUSTMENT” and
“EXTERNAL PROBE” in the CH120RF manual). Note: in a multi-zone system only
CH120RF associated to zone 2 can be configured with external probe set as
remote probe for CH180RFWIFI.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
LIGHT ON 30S
EXT IN: —
PRESS
PRESS
—
2s
DEW
ESC
CHG 0
x13
ALR 0
ESC
ALR C
ESC
LOW
HIGH
— = action disabled
Connecting to CH120RF you can use the following functions after connecting an
EC18-EC19-EC20 temperature probe: DEW = floor system condensate formation
control in summer through control of the dew point (a floor probe is
required). Note: with the control active, when a zone switches the cooling
system off, the symbol flashes in the corresponding zone. LOW = minimum safety
temperature exceeded alarm. This is a safety threshold, only active in the
SUMMER season and disables the system. To activate, press OK and set the
desired minimum threshold using the or keys. HIGH = maximum safety temperature
exceeded alarm. This is a safety threshold, only active in the WINTER season
and disables the system. To activate, press OK and set the desired minimum
threshold using the or keys.
Connecting to CH120RF a voltage-free contact allows you to use the following
functions: CHG O = switch-over to SUMMER mode with closed contact and WINTER
mode with open contact ALR O = display of alarm message in presence of open
contact ALR C = display of alarm message in presence of closed contact
33
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.15 – COOL OFF
Allows you to control floor system condensate formation in SUMMER without
having a floor probe.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
LIGHT ON 30S
COLL OFF NO
PRESS
PRESS
2s
NO
ESC
x14
YES
ESC
ESC
If COOL OFF = YES, the CH180RFWIFI controls cooling system shut-down at the same time as dehumidifier activation (it is necessary to set a RH% threshold and the DEW function must be disabled).
Note: with the control active, when a zone switches the cooling system off, the symbol corresponding zone.
flashes in the
34
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.16 – AUX1
This parameter allows to operate the relay of CH175 associated to the
programmable thermostat in different modes. The following functions are
available:
PROG = sets the on/off time profile of an external utility (e.g. irrigation,
yard light, etc.) in a 24-hour span; MAN = sets relay2 in manual/ ON-OFF mode,
activated locally by USER PROG (see paragraph 3.4).
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
3s
ADVAN PROGR
LIGHT ON 30S
AUX1 : MAN
PRESS
2
LIGHT ON 30S CELSIUS
INT LIGHT 5 ENGLISH
2s
DAY SVNGS YES EXT IN: —
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
PROG
MAN x15
ESC ESC
AUX1 : PROG
PRESS
3
OK
OK ESC
Off
ESOCN OFF
Pressing or allows you to scroll the different time bands. Press the or arrows
to switch AUX1 relay on/off.
Note: CH175 in AUX 1 mode can only be associated to the programmable
thermostat CH180RFWIFI and must be configured as auxiliary actuator AUX 1.
35
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.17 – ZONE DEU
Allows to associate the zone groups (consisting of CH180RFWIFI and CH120RF) to
a dehumidifier/VMC connected to a CH175. There can be 2 groups:
DEU A GROUP; DEU B GROUP
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
3s
ADVAN PROGR
LIGHT ON 30S
2
LIGHT ON 30S CELSIUS
INT LIGHT 5 ENGLISH DAY SVNGS YES EXT IN: —
2s
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
ESC
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
ZONE DEU
PRESS
x16 OK
PRESS OK
ESC
ZONE: A
3
ZO NE
1
ESC
The keys or allow you to scroll the zones in CH180RFWIFI. The or arrows
associate the DEU A, DEU B group or—for each zone displayed.
Note: Only the zones with CH180RFWIFI and CH120RF are displayed. CH175 in DEU
ZONE A or in DEU ZONE B can only be associated with programmable thermostat
CH180RFWIFI and must be configured as auxiliary actuator DEU ZONE A or DEU
ZONE B.
36
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.18 – ZONE INT
It allows you to associate groups of zones (formed by CH180RFWIFI and CH120RF)
to a VMC connected to a CH175. Groups can be 2
INT GROUP A; INT GROUP B.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G
ZO NE
O FF
ESC
3s
ADVAN PROGR
2 LIGHT ON 30S CELSIUS
INT LIGHT 5
ITALIAN
NOW LEG SI
EXT IN: —
TA = 5.0
COOL OFF NO
UR = —
AUX1: MAN
RELE: OFF
DEU ZONES
ZONE NAMES
INT ZONES
OFFSET
WIFI: A.P.
DIFF: STD
CH180RW V1.0
ECO : OFF
RESET NO
INT. DIFF:—
LIGHT ON 30S
2s
ESC
ZONE INT
PRESS
x17
OK
PRESS OK
ESC
ZONA: A
3
ZO NE
1
ESC
The keys o the zones on the CH180RFWIFI scroll. The arrows o they associate the INT A, INT B or — group for each displayed zone. Note: Only the zones with CH180RFWIFI and CH120RF are displayed. CH175 in INT ZONE A or INT ZONE B mode can only be associated with the chronothermostat CH180RFWIFI and the INT ZONE A or INT ZONE B auxiliary actuator must be configured.
37
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.19 – WIFI
Displays device WiFi connection status.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
3s
ADVAN PROGR
LIGHT ON 30S
WIFI: A.P.
2
LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
2s
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
PRESS
—
x18 NORM.
ESC
A.P.
— = off NORM. = normal A.P. = access point (allows you to connect a smartphone)
PRESS ESC
ESC
7.20 – SLEEP
It allows to set the entire heating system in the “energy saving” mode. This
function is displayed with [OFF] both in the main screen and in all zones.
NOTE: to restart the system it is compulsory to set a new functioning mode
ONLY from the main screen or from the Intelliclima+ APP. To allow the system
functioning completely, it could be necessary to wait up to 8 hours maximum.
12:01 01-01-18
LIGHT ON 30S
1
DAY
[ MAN ]
1
23.0 36RH%
2s
M O DE DISP
PRO G ZO NE
O FF
ESC
ESC
3s
SLEEP : OFF
PRESS
OFF ON x19
ADVAN PROGR
2
LIGHT ON 30S CELSIUS
INT LIGHT 5
ITALIAN
NOW LEG SI
EXT IN: —
TA = 5.0
COOL OFF NO
UR = —
AUX1: MAN
RELE: OFF
DEU ZONES
ZONE NAMES
INT ZONES
OFFSET
WIFI: A.P.
DIFF: STD
SLEEP : OFF
ECO : OFF
CH180RW V1.0
INT. DIFF:—
RESET NO
PRESS ESC
ESC
38
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
7.21 – INFORMATION
Displays the software version of the programmable thermostat.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
LIGHT ON 30S
CH180RW V1.0
PRESS
PRESS
2s
ESC
x20
ESC
ESC
7.22 – RESETTING DEFAULT PARAMETERS
Allows you to reset all parameters (except the date and time) to the factory
settings.
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
3s
ADVAN PROGR
2
LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
LIGHT ON 30S
2s
ESC
RESET NO
PRESS
NO YES x21
RESET YES
3
OK
PRESS OK
ESC
PRESS ESC
ESC
39
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT
8 – REMOTE PROGRAMMING VIA APP
The WiFi signal on the programmable thermostat allows you to remotely control
the device via the Intelliclima+ app, available free of charge from the Google
Play Store and Apple App Store.
8.1 – WIFI ACTIVATION
The programmable thermostat WiFi connection is off upon first start-up. To
activate it, go to ADVANCED PROGRAMMING and follow the instructions.
Intelliclima+
12:01 01-01-18
1
DAY
[ MAN ]
1
23.0 36RH%
M O DE DISP
PRO G ZO NE
O FF
ESC
3s
ADVAN PROGR
LIGHT ON 30S
WIFI: A.P.
2
LIGHT ON 30S CELSIUS INT LIGHT 5 ENGLISH
DAY SVNGS YES EXT IN: —
2s
TA = 5.0
COOL OFF NO
RH = —
AUX1: MAN
RELAY: OFF
ZONE DEU
ZONE NAMES WIFI: A.P.
OFFSET
CH180RW V1.0
DIFF: STD
RESET NO
PRESS
—
NORM.
x15
A.P.
ESC
PRESS ESC
ESC
— = off NORM. = normal A.P. = access point (allows you to connect a smartphone)
Select A.P. and press ESC. Start up the guided installation procedure on the app as described in the “INSTALLATION PROCEDURE” paragraph.
40
CH180RFWIFI TOUCHSCREEN WIRELESS WEEKLY PROGRAMMABLE THERMOSTAT 8.2 – INSTALLATION PROCEDURE
Install the app and, upon first
1
activation, create an account by
entering a user name and password.
Create a new house by pressing the
2
key. Enter the desired name and
press
.
Add the programmable thermostat
3
by pressing the key and select
CH180RFWIFI.
At the end of this procedure, the new
4
programmable thermostat will be
displayed inside the home.
41
CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
8.3 – CONNECTION PROBLEMS
If the router does not connect to the server: 1. Check that the router
password is correct, repeating the steps in paragraphs 8.1 and 8.2; 2. Check
that the router supports standard 802.11 b/g/n; 3. Contact your Internet
provider and have port 1080 opened at the IP address of the server:
92.48.107.8
42
CH180RFWIFI WIRELESS TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION
9 – DISPOSAL
The symbol of the crossed-out wheeled bin indicates that the products must be
collected and disposed of separately from household waste. The batteries and
integrated accumulators may be disposed of together with the product. They
will be separated at the recycling facilities. A black bar indicates that the
product was placed on the market after August 13th, 2005. Participating in the
separate collection of products and batteries contributes to the correct
disposal of these materials and therefore avoids possible negative
consequences for the environment and human health. For more detailed
information on the collection and recycling programmes available in your
country, contact the local authorities or the sales point where you purchased
the product.
10 – GENERAL WARRANTY CONDITIONS
The conventional warranty lasts 24 months, starting from the date the
equipment is installed. The warranty covers all parts of the equipment, with
the exception of those subjected to normal wear.
43
EN79898C- 04/2022