YINGJIAO YSL15T LED Power Supply Owner’s Manual
- June 13, 2024
- YINGJIAO
Table of Contents
LED Power Supply
YSL15T SERIES
Input: 100-240VAC 50/60Hz;
200-240VAC 50Hz
Output Voltage: 12V,24V,36V,48VDC
Rated Power: 15W max
Features
- Universal Input: 100-240V AC 50/60Hz; 200-240VAC 50Hz
- RoHS Compliance
- EMI Standard EN55015:2019+A11
- Safety Standard: EN61347-1:2015, EN61347-213:2014+A1:2017, UL8750
- Inrush current<65A AC230V/50Hz
- High efficiency & low power consumption
- Short Circuit, Over Current and Over Voltage Protection
- Over temperature protection
- 100% full load burn-in test
Application
LED strips
LED indoor lighting
LED decorative lighting
LED building lighting
Dimensions and Installation
MODEL DETAIL SPEC.| YSL15T-1201250| YSL15T-2400625|
YSL15T-3600416| YSL15T-4800312
---|---|---|---|---
INPUT| Input Voltage:| 100-240VAC/200-240VAC
Input Frequency:| 50/60Hz
Inrush Current:| 65A/230VAC at full load
AC Current:| 0.17A/115VAC 0.085A/230VAC
Leakage Current:| < 0.25mA/240VAC
Efficiency:| 88%
OUTPUT| OC Voltage:| 12V| 24V| 36V| 48V
Rated Current:| 1250mA| 625mA| 416mA| 312mA
Rated Power:| 15W
Voltage Tolerance:| ±5.0%
Ripple and Noise:| 120mVp-p| I 240mVp-p| I 360mVp-p| I 480mVp-p
Line Regulation:| ±3%
Load Regulation:| ±5%
Setup, Rise, Hold Up time:| 1s, 10ms/60ms 230VAC 1000ms, lms/25ms 115VAC at
full load
ENVIRONMENTAL| Operating Temperature:| -20 — +50 (Refer to “Clerating Curve”)
Storage Temp:| -40°C — 85°C
Storage Humidity:| 20 — 95% RH
Working Humidity:| 20 — 95% RH non-condensing
PROTECTION| Over Load:| Above 105%-130% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is
removed
Over Voltage:| 12V:13.8 — 16.2V 24V : 27.6 — 32.4V 36V:41.4 — 48.6V 48V :
55.2—.64.8V
Protection type: Shut down o/p voltage, re-power on to recover
Over Temperature:| Shut down pip voltage. re-power on to recover
SAFETY & EMC| Safety Regulations:|
EN61347-2-13:2014+A1:2017,EN61347-1:2015;EN62493:2015
Withstand Voltage:| UP-0/P:3.75KVAC
Harmonic| EN61000-3-2 Class C EN61000-3-3
EMI:| Compliance to EN55015
EMS :| compliance to 61547:2009
OTHER| MTBF:| 200,000 Hours Minimum at Full Load at 25°C Ambient
Size:| 1603016mm
Weight:| 150g / pcs
Packaging:| 100PCS/CIN
Deduction curve and temperature
Environment temperature(℃)
Minus output
and input voltage curves
Input voltage(VAC)
Functional Diagram