YINGJIAO YSL40 Factory Wholesale Constant Current LED Power Supply User Guide
- June 3, 2024
- YINGJIAO
Table of Contents
YINGJIAO YSL40 Factory Wholesale Constant Current LED Power Supply
Features
- Universal Input: 100-240V/200-240VAC50-60Hz
- RoHS Compliance
- EMI Standard EN55015
- Safety Standard: EN61347-1, EN61347-2-13, UL8750
- Inrush current<65A AC230V/50Hz
- High efficiency & low power consumption
- Short Circuit, Over Current and Over Voltage Protection
- Over temperature protection
- 100% full load burn-in test
Application
- LED strips
- LED indoor lighting
- LED decorative lighting
- LED building lighting
Dimensions and Installation
MODEL DETAIL SPEC. | YSL40 1203300 | YSL40 2401660 | YSL40 3601100 | YSL40 4800830 |
---|---|---|---|---|
INPUT | Input Voltage: | 100-240VAC/ 200-240VAC | ||
Input Frequency: | 50-60Hz | |||
Inrush Current: | 65 Amps max. at 230VAC/50Hz,full load | |||
AC Current: | 0.17A/230VAC | |||
Leakage Current: | <0.25mA/240VAC | |||
Efficiency: | 88% | 88% | 88% | 88% |
OUTPUT | DC Voltage: | 12V | 24V | 36V |
Rated Current: | 3.3A | 1660mA | 1100mA | 830mA |
Rated Power: | 40W | 40W | 40W | 40W |
Voltage Tolerance: | ±5.0% | ±5.0% | ±5.0% | ±5.0% |
Ripple and Noise: | 120mVp-p | 240mVp-p | 360mVp-p | 480mVp-p |
Line Regulation: | ±3% | |||
Load Regulation: | ±5% | |||
Setup, Rise, Hold Up time: | 1s, 10ms/60ms 230VAC 1000ms, 1ms/25ms 115VAC at |
full load
ENVIRONMENTAL| Operating Temperature:| -20 ~ +50 (Refer to “Derating Curve”)
Storage Temp:| -40℃ ~ 85℃
Storage Humidity:| 20 ~ 95% RH
Working Humidity:| 20 ~ 95% RH non-condensing
PROTECTION| ****
Over Load:
| Above 105%-130% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is
removed
Over Voltage:| 12V:13.8 ~ 16.2V 24V:27.6 ~ 32.4V 36V:41.4~48.6V 48V:55.2~64.8V
Protection type: Shut down o/p voltage, re-power on to recover
Over Temperature:| Shut down o/p voltage, re-power on to recover
SAFETY & EMC| Safety Regulations:|
EN61347-2-13:2014+A1:2017,EN61347-1:2015;EN62493:2015
Withstand Voltage:| I/P-O/P:3750KVAC
Harmonic| EN61000-3-2 Class C EN61000-3-3
EMI:| Compliance to EN55015
EMS:| compliance to 61547:2009
OTHER| MTBF:| 200,000 Hours Minimum at Full Load at 25℃ Ambient
Size:| 1605820mm
Weight:| 200g / pcs
Packaging:| 100PCS/CTN,37.528.524cm
Deduction curve and temperature
Environment temperature(℃)
Minus output and input voltage curves
Input voltage(VAC)
Functional Diagram
Read User Manual Online (PDF format)