Input: 100-240VAC 50/60Hz; 200-240VAC 50Hz Output Voltage: 12V,24V,36V,48VDCRated Power: 30Wmax

Features

  • Universal Input:
    100-240V AC 50/60Hz; 200-240VAC50Hz

  • RoHS Compliance

  • EMI Standard EN55015:2019+A11

  • Safety Standard: EN61347-1:2015, EN61347-2-13:2014+A1:2017, UL8750

  • Inrush current<65A AC230V/50Hz

  • High efficiency & low power consumption- Short Circuit, Over Current and Over Voltage Protection

  • Over temperature protection

  • 100% full load burn-in test

Application

LED strips
LED indoor lighting
LED decorative lighting
LED building lighting

Symbols

Dimensions and Installation

MODEL DETAIL SPEC.| YSL30T-1202500| YSL30T-2401250| YSL30T-3600833| YSL30T-4800625
---|---|---|---|---
INPUT| Input Voltage:| 100-240VAC/200-240VAC
Input Frequency:| 50/60Hz
Inrush Current:| 65A/230VAC at full load
AC Current:| 0.34A/115VAC 0.17A/230VAC
Leakage Current:| <0.25mA/240VAC
Efficiency:| 88%
OUTPUT| DC Voltage:| 12V| 24V| 36V| 48V
Rated Current:| 2500mA| 1250mA| 833mA| 625mA
Rated Power:| 30W
Voltage Tolerance:| ±5.0%
Ripple and Noise:| 120mVp-p| 240mVp-p| 360mVp-p| 480mVp-p
Line Regulation:| ±3%
Load Regulation:| ±5%
Setup, Rise, Hold Up time:| 1s, 10ms/60ms 230VAC  1000ms, 1ms/25ms 115VAC at full load
ENVIRONMENTAL| Operating Temperature:| -20 ~ +50 (Refer to “Derating Curve”)
Storage Temp:| -40℃ ~ 85℃
Storage Humidity:| 20 ~ 95% RH
Working Humidity:| 20 ~ 95% RH non-condensing
PROTECTION| Over Load:| Above 105%-130% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over Voltage:| 12V:13.8 ~ 16.2V 24V : 27.6 ~ 32.4V

36V:41.4 ~ 48.6V 48V:55.2~64.8V

Protection type: Shut down o/p voltage, re-power on to recover
Over Temperature:| Shut down o/p voltage, re-power on to recover
SAFETY & EMC| Safety Regulations:| EN61347-2-13:2014+A1:2017,EN61347-1:2015;EN62493:2015
Withstand Voltage:| I/P-O/P:3.75KVAC
Harmonic| EN61000-3-2 Class C EN61000-3-3
EMI:| Compliance to EN55015
EMS:| compliance to 61547:2009
OTHER| MTBF:| 200,000 Hours Minimum at Full Load at 25℃ Ambient
Size:| 2513017mm
Weight:| 150g / pcs
Packaging:| 100PCS/CTN

  • Deduction curve and temperature
    Deduction curve and temperature

  • Minus output and input voltage curves
    Minus output and input voltage curves

Functional Diagram

Functional Diagram

Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals