EcoNet UETST800SYS Smart Thermostat User Guide

June 13, 2024
EcoNet

EcoNet Logo Smart Thermostat
User Guide

EcoNet UETST800SYS Smart Thermostat Model: UETST800SYS
TO VIEW THE SMART THERMOSTAT
USER GUIDE IN FRENCH

EcoNet Smart Thermostat User Guide

The EcoNet® Smart Thermostat is an easy-to-use programmable thermostat that provides complete control over your home’s smart air and water comfort systems. It’s smart enough to alert you when an issue is detected, yet it’s designed to be simple to operate with an intuitive touchscreen interface. And it has built-in WiFi so you can monitor your system and adjust temperatures and schedules while on-the-go.
More than a thermostat, it’s part of an intuitive system that maximizes comfort and efficiency while offering complete peace of mind—so you can stay focused on what matters most.

Items Included in the Box

EcoNet Smart Thermostat
Wall Mounting Plate
Ferrite Toroid
Mounting Screws and Drywall Anchors
Quick Start Guide

EcoNet UETST800SYS Smart Thermostat - the Box

Homescreen Overview

EcoNet UETST800SYS Smart Thermostat - Homescreen
Overview

What This Means to Me, The Homeowner:

Weather
Current weather condition and outside temperature; tap to see forecast

Brand Logo
Tap to access contractor information and support help

One-Touch Away
Tap once to enter preset Away settings; tap again to return to previous settings or resume schedule

Indoor Temperature
Shows the current temperature inside your home

Menu
Tap to navigate to the full Menu where you can change basic settings, customize your schedule and more

Alert
Indicates an important reminder, minor alert, or critical alarm; tap for additional details

WiFi
Current WiFi signal strength; tap to start the setup process

Humidity
Current relative humidity in your home; tap to configure to your preference

System Mode
Tap to navigate to Mode selection screen (auto/heat/cool/e-heat/fan/off)

Icons to Become Familiar With

EcoNet UETST800SYS Smart Thermostat - Menu

Standby Screen

If the thermostat has not been touched for 30 seconds, the screen dims and the standby screen activates displaying indoor temperature and outdoor weather conditions. If an alert or alarm is present, the alert / alarm icon will be displayed as well.
The motion sensor will automatically wake the thermostat and activate the home screen as you approach.
Motion Sensor may not be available on all units.

The standby screen can be turned off by disabling the back-light under basic settings (Menu > Settings > Basic)

System Modes

The EcoNet Smart Thermostat will call for heat or cool based on the current settings and temperature. Cooling and heating equipment may have a delay period before operation is enabled. The delay can be up to 5 minutes (if the mode was changed right after equipment turns off). Status screen will show a “Hold-Off Timer” for Equipment State.

Select the mode icon in the bottom right corner of the home screen to quickly change the operating mode.

Select from Auto, Heat, Cool, E-Heat, Fan and Off.

Auto – Activates the heating or cooling system as required to keep your home within the configured range of set point temperatures. Select the desired set point, and then use the large adjustment buttons to set the desired temperature.
To adjust your cooling set point, tap the set point on the right – it will turn blue, then adjust using the plus and minus buttons. The current temperature in the center of the screen will temporarily be replaced by the set point in large font during temperature adjustments.’

Note: The default deadland or separation between the heating and cooling set points is 2 degrees.

Heat – Turns on heating when the current temperature drops below your set point temperature. When there is an active call for heating, the words ‘Heating To’ will appear above the heating set point.

(Heating set point screen)

EcoNet UETST800SYS Smart Thermostat - System Modes Cool – Turns on cooling when the current temperature rises above your set point temperature. When there is an active call for cooling, the words ‘Cooling To’ will appear above the cooling set point.

EcoNet UETST800SYS Smart Thermostat - System Modes 2(Cooling set point screen)

EcoNet UETST800SYS Smart Thermostat - Figure 7 E-Heat (Heat Pump Systems Only) – The emergency heat option is a manual setting, not an automatic function initiated by the heat pump thermostat.
The purpose of the emergency heat setting is to bring the backup heat source online immediately to deliver 100% of the home’s heating demand while simultaneously locking out the heat pump.

EcoNet UETST800SYS Smart Thermostat - Figure 8 Fan Only – While in Fan Only mode, the heating/cooling equipment is turned off. Use the plus or minus adjustment buttons to navigate between fan speeds from Low to High. Press Mode again to reactivate a heating or cooling mode. Fan only is a manual override of a set schedule. If a schedule is being followed, the fan speed will return to the scheduled fan speed when you reactivate the heating/ cooling equipment. You can set continuous fan when in Heating, Cooling or Auto mode from the Settings screen.

You can manually adjust the temperature from the Home Screen by touching the plus and minus buttons. When the set point is being changed, the ring will either turn blue or red—depending on the mode of operation—and the new set point is displayed in the center of the screen. If Auto mode is selected, press the lower left set point (red) for heat or lower right set point (blue) for cool.

EcoNet UETST800SYS Smart Thermostat - Figure 10

Connecting to WiFi

Your EcoNet Smart Thermostat supports WiFi 802.11 b/g/n. WiFi is normally configured during initial setup. You may, however, be required to reconfigure the settings if your WiFi network settings change.
Connecting to WiFi will enable you to view the local weather and allow you to remotely manage your comfort and receive critical alarms should something ever go wrong. To save time, we recommend having your home WiFi network password and your Internet-connected smartphone or tablet close to the thermostat before you begin.

  1.  Download the EcoNet App and ensure your smartphone or tablet is already connected to your home WiFi network.
  2. Select ‘Create Account’ and follow the instructions.
  3. On the EcoNet Smart Thermostat, tap the WiFi icon in the top right corner of the home screen (See Fig. 1).
  4. Select ‘Get Started’ (See Fig. 2).
  5. When ‘Ready to Connect’ appears, use the EcoNet App to complete the setup process (See Fig. 3).
  6. Follow the in-app instructions to complete your connection.
  7. You may be required to enter your network password.
  8. Tap ‘Done’ to complete setup (See Fig. 4).

EcoNet UETST800SYS Smart Thermostat - Figure 11

Weather

Tap the weather icon on the home screen to display local weather conditions and view the hourly and daily forecasts. The weather will be based on the current location or ZIP code used when creating your EcoNet account.

EcoNet UETST800SYS Smart Thermostat - Figure 12

EcoNet UETST800SYS Smart Thermostat - Figure 13Tap the Menu icon in the bottom left corner of the home screen to easily view and configure your personal and system settings.

Settings

EcoNet UETST800SYS Smart Thermostat - Figure 14 Settings (Menu > Settings)
Adjust system-level settings and preferences, from customizing your away temperatures to scheduling a vacation. Tap the Menu icon from the home screen and then tap Settings.

EcoNet UETST800SYS Smart Thermostat - Figure 15 Basic (Menu > Settings > Basic)
Adjust thermostat or basic equipment settings and preferences.

Follow Schedule – If a programmed schedule is desired, set to “Yes.”
Alarm   Beep Enable – Sounds an audible alarm tone shall a critical alarm condition occur.
Screen   Lock– To lock the main screen from any changes, enable the lock. To unlock, enter the Basic settings menu again and set Screen Lock to “No.” This locking function prevents any changes except changes made from within the Basic Settings.
Temperature Display – Change your indoor temperature and set points between Fahrenheit and Celsius.
Schedule Override Time – While a schedule is running, if a set temperature change occurs on the main screen, the change will be in effect for this amount of time. The default is 2 hours. You can customize between a minimum override of 1 hour and a maximum  f 8 hours.
Auto Changeover Time – When the system is in Auto mode, this is the amount of time demand must exist in the opposite mode (cooling or heating) in order for the system to switch to that mode. The default is 5 minutes. The setting is configurable between 5 and 60 minutes.

EcoNet UETST800SYS Smart Thermostat - Figure 18

More >
Set Point Deadband – This is the minimum difference between heating and cooling set points in Auto mode. The default is 2 degrees. This setting is configurable between 0 and 6 degrees. A 0 degree deadband means your system will switch between heating and cooling to maintain the specified set point. The smaller the deadband setting the more frequently your system will switch between heating and cooling.

Temperature Offset – This is an offset applied to the displayed room temperature. A negative offset will cause the displayed indoor temperature to be less than the sensed temperature. A positive offset will cause the displayed temperature to be higher than sensed temperature.

Relative Humidity Offset – This is an offset applied to the indoor relative humidity. A negative offset will cause the displayed relative humidity to be less than the sensed relative humidity. A positive offset will cause the displayed relative humidity to be higher than sensed relative humidity.

Note: You should allow the thermostat to calibrate in the conditioned space for 30 minutes before adjusting offsets.

Room Sensor Selection – You can wire a remote 10K temperature sensor to the EcoNet Smart Thermostat. If a remote temperature sensor is connected, you can choose to use the remote sensor, internal sensor on the Smart Thermostat or an average between the two for current indoor temperature.
Optimized for use with an April Aire 8051 indoor temperature sensor.

Proximity Sensing** – Selecting ‘No’ will disable the motion sensor. To activate the thermostat, you will need to tap the screen.
Motion Sensor may not be available on all units.

Smooth Arrival – The thermostat will start recovery at the optimum time to ensure the set point is reached at the scheduled time. If a setback in temperature is scheduled, for either cooling or heating, the set temperature is ramped to the next scheduled set temperature 60 minutes before the next time period.

Backlight Enabled – When the thermostat is not being used it will enter standby mode. The default screen brightness in standby is 1%. You can turn off the Backlight when in standby by selecting “No.”

Time & Date (Menu > Settings > Time)
Set the current time and date. Your schedule times, vacation events and weather forecast will be based off the time entered on this screen. It is important to ensure the correct date and time are programmed before setting your schedule.

DST – At the bottom of this screen you can elect to enable or disable daylight savings time.

Humidity Settings (Menu > Settings > Humidity)
Control your home’s humidity settings for more ideal comfort.

Dehumidification (Menu > Settings > Humidity)
Enable Dehumidification – The system will attempt to reduce humidity in cooling mode by reducing fan speed and over-cooling the space (when allowed by the Over-Cooling setting). The system will only reduce airflow if the room temperature is within one degree of set point, otherwise, full cooling airflow will be performed. Dehumidify Set Point – The indoor relative humidity to be controlled to while in cooling mode.

Over-Cooling Amount – The system will activate cooling, and possibly overcool the space by the desired number of degrees to improve dehumidification performance in an effort to reach the dehumidify set point. The factory setting for over-cooling is zero  no
over-cooling) and can be adjusted up to 5 degrees of over-cooling.

Dehumidify Drain Timer – At the end of a cooling cycle, if set, the continuous fan setting will be turned off for the selected amount of time in order to drain water from the indoor coil.

Humidification (Menu > Settings > Humidity > Humidification)
Enable Humidification – The system can control a humidifier attached to the furnace or air handler to increase humidity in the space. It is important to note you cannot humidify above the dehumidification set point.
Humidification Set Point – This setting allows you to choose the indoor relative humidity desired, under which humidification will activate. The default is humidification set point is 30% and is configurable between 15 and 45%.
Humidify During – Select the modes in which humidification will be performed. Humidification can occur during heating, continuous fan and/or cooling mode.

  • Heat – Humidifier will operate with equipment during Heat if a humidification demand is present.
  • Heat/Fan – Humidifier will operate with equipment during these modes if a humidification demand is present.
  • Heat/Fan/Cool – Humidifier will operate with equipment during these modes if a humidification demand is present.

Smart Control – Smart Control is used to reduce or prevent water condensation on the inside of windows while humidifying in the winter season. The control monitors indoor and outdoor temperatures and reduces the humidification percentage according to the Smart Control level chosen by the user. Start out with the Low setting. If objectionable condensation occurs on windows, choose the Medium or High setting.

Humidify With Fa n – If there is a call to humidify and the fan and heating/ cooling are off, the fan will be forced on to humidify. Select the desired fan speed from Low to High.

Note: Humidification is only available if a humidifier is installed.

How to test a humidifier
Adjust the humidify set point up to ‘TEST’, select Humidify during “Heat/Fan”, then turn on a continuous fan speed on the Fan screen under Settings. This should force the humidifier to run. This setting will last for 30 minutes, where the maximum setting will return to 4% below the dehumidification set point.

Away Settings (Menu > Settings > Away)
Your system will follow the customized heating, cooling and fan settings when you place your system into ‘Away’ mode. The system can be placed into Away by selecting the Home icon (closed door) on the home screen. Once the system is placed into Away mode it will remain until canceled. Simply tap the Away icon (open door) to exit Away mode. The system will resume the schedule or return to the previous settings if a schedule is not being followed. You can also exit Away by increasing or decreasing the temperature.

Note: If your system is in Cool or Heat when placed into Away mode your system will only manage to the respective Away set point.

Vacation (Menu > Settings > Vacation)
The Vacation screen allows you to preschedule desired heating, cooling and fan settings when you are going to be away for an extended time.
To schedule your vacation, select the time, month, day and year and then use the up and down arrows to set desired start and end dates.

Note: You will need to set the vacation end time and date before you can set its start.

Select each set point and fan speed and then use the up down arrows to set to your desired vacation conditions. We recommend setting the fan speed to Auto.

Vacation Activated – A Vacation will be indicated by the word ‘Vacation’ above the current temperature on the home screen and an active Away button.
Tap Vacation on the home screen to cancel and resume schedule or return to previous settings.
Your HVAC equipment will automatically follow a vacation event. If you have a connected water heater, you have the option to have your water heater follow the vacation event; simply toggle the button to Yes.

EcoNet UETST800SYS Smart Thermostat - Figure 31 Fan (Menu > Settings > Fan)
Continuous Fan – Chose from one of 5 speeds to run continuous fan. This setting allows the fan to continue circulating air in between calls for heating or cooling. If the system is following a schedule the fan speed presented will match the speed set in your schedule. You can temporarily override the scheduled fan speed here. You will notice the copy on screen changes to ‘Fan Speed Override’.
The override will follow the ‘Schedule Override Time’ set in Basic Settings.

Schedules

Tapping Menu > Schedule will present your current schedule. First, please ensure the correct date and time settings have been entered under Settings. To edit the schedule for a day, tap the day of the week you want to edit. Tap the day part (morning, day, evening or night) time and use the up and down arrows to set the desired start time. Next tap the heat set point, cool set point and/or fan speed for each day part and use the up and down arrows to change to your desired settings. Your system will follow your preferred settings until the next day part start time is reached. If Smooth Arrival is enabled under Basic Settings, your system will start recovery up to 60 minutes early to ensure the set points for the next scheduled day part are reached at the scheduled time.

To copy a day’s schedule to another day, tap “Copy Day”, then select the day(s) you wish to copy to, then tap “Paste Day.” You can select “Cancel” to cancel the paste day operation.

When a schedule is being followed and a manual adjustment is made overriding the schedule, a Resume Schedule option will be displayed above the current temperature on the home screen. The schedule will be temporarily overridden according to the schedule override time under Basic Settings. The default schedule override time is two hours. Your schedule will automatically resume once the override expires. You can also resume the schedule by tapping ‘Resume Schedule’ on the home screen.

Status

Tapping Menu > Status will display the connected communicating equipment, thermostat mode and the equipment operating status.

Selecting Furnace, Air Handler or AC/HP on the Status screen will display each piece of equipment’s current operating status and historical cycles and run times.

Furnace Status – Displays detailed furnace operation information including two week and lifetime cycles, as well as run time hours.

AC/HP Status – Displays detailed AC/HP operation information including two week and lifetime cycles, as well as run time hours.

EcoNet UETST800SYS Smart Thermostat - Figure 39 Air Handler Status – Displays detailed air handler operation information including two week and lifetime cycles, as well as run time hours.

Service

Selecting Menu > Service from the home screen will display current alarms, alarm history, service alerts, contact info and equipment info.

Current – Shows any alerts or alarms that are currently active. When an equipment alert/alarm is present, an alert/alarm icon will appear in the upper right corner of the home screen, and the alarm beep will sound if enabled. Select the alert/alarm icon on the home screen to quickly view the alert/alarm and a brief description.

EcoNet UETST800SYS Smart Thermostat - Figure 42History – Shows a list of the past eight alerts/alarms with the time and date stamp.

Alerts – Allows you to set time-based maintenance reminders for a service call, humidifier pad and UV light replacement. Toggle to ‘No’ to disable service reminders. You can also change the time for the alert. If a Service Alert is present, the item will have a “reset” label next to it. Tapping “reset” will clear the alert and start the maintenance timer over.

  • Service Call – Generates an alert telling the homeowner that regularly scheduled maintenance is due.

  • Air Filter – If a common ‘media’ filter is used, our EcoNet system is smart enough to detect and alert you when it is time to replace the air filter. You can easily see how much life your air filter has left by checking the percent used. If no alert is sent in a 12 month period the system will automatically remind you it is time to replace the air filter.
    If an Electronic Air Cleaner (EAC) filter is used the reminder will revert back to a time based reminder. The default is set to 6 months.

  • Humidifier Pad – Reminds you to clean or replace the humidifier pad based on your chosen interval.

  • UV Lights – Generates an alert indicating that it is time to clean or replace the lamp if the HVAC system uses a UV lamp for air purification.

Support – Allows you to input your contact information for your preferred contractor or install professional (company name, phone number and email address), so that it’s always available should you run into any issues. Simply use the on-screen keyboard to enter the appropriate contact information. Any contact information you enter will also be available in the EcoNet App.
Note: You should always contact your preferred contractor or install professional regarding alerts/ alarms, performance issues or other questions specific to your equipment.

Additionally, the WiFi and App Support phone number is permanently stored for easy access. EcoNet Support is available for help with WiFi connectivity, App issues and basic operation of the EcoNet Smart thermostat.

EcoNet UETST800SYS Smart Thermostat - Figure 47 Equip. – Displays the model, serial number and software version of all your connected equipment

Water Heating

If an EcoNet Enabled water heater is connected to the system, you will see a Water Heating icon under Menu.

EcoNet UETST800SYS Smart Thermostat - Figure 49When a water heater is connected you can:

  • View current state of operation
  • View and change the set point
  • Elect to have the water heater follow a Vacation event (water heater set point is lowered to 72°F).
  • Receive a notification on the thermostat if a water heater alarm is active

EcoNet Smart Thermostat Installation Instructions

The EcoNet System consists of several intelligent, communicating components. Commands, operating conditions, and other data are passed continuously between components. All system components are controlled through the wall mounted EcoNet Smart Thermostat, which replaces the conventional thermostat and provides the homeowner with a single wall control for all features of the system.

Note: Read the entire instruction manual before starting the installation

Safety Considerations

Failure to read and follow all instructions carefully before installing or operating this control and system could cause personal injury and/or property damage.

WARNING: Power off your Heating, Ventilation and Air Conditioning system by using the master switch or circuit breaker box
Note: All wiring must comply with national, local and state codes ‘

Thermostat Location

The EcoNet Smart Thermostat is the command center for the EcoNet System, as well as the control for the heating and cooling equipment. It should be located where it is easily accessible and visible to the homeowner or end user. For accurate zone temperature and humidity measurement, the following guidelines should be followed:

The EcoNet Smart Thermostat should be mounted:

  • Approximately 5 feet (1.5 m) from the floor
  • Close to or in a frequently used room, preferably on an inside wall

Decide if you want to use the adapter plate with your new EcoNet Smart Thermostat. The adapter plate is useful if you want to hide marks or holes left by your previous thermostat.

Note: The adapter plate is sold separately. Adapter Plate – RETSTWPL700.

The EcoNet Smart Thermostat should NOT be mounted:

  • Close to a window, on an outside wall, or next to a door leading to the outside.
  • Exposed to direct light or heat from a lamp, sun, fireplace, or other temperature-radiating objects which could cause a false reading
  • Close to or in direct airflow from supply registers or returns
  • In areas with poor air circulation, such as behind a door or in an alcove
  • On a section of wall with pipes or ductwork

If you are installing with a remote temperature sensor, place your remote sensor at a height of approx. 5 feet (1.5 m) on an interior wall, away from direct heat/cool sources (e.g. fireplace, air vents, etc.)

Wiring Considerations

Ordinary thermostat wire is recommended. Use 18 AWG or larger for normal wiring applications. Wire should be free from defects such as wear, cracks or anything that would hinder the conductivity of the wire within the circuit.
Note: Wiring only requires four wires. However, it is good practice to run thermostat cable having more than four wires in the event of a damaged or broken wire during installation.
The units should be wired in a “daisy chain” and not in a “star” configuration. To “daisy chain” the units on the network, each unit should have a set of wires coming into it and one set going out of it except the two communicating devices that are at the ends of the network. The devices on the ends should have only one set of wires to it. The order of the devices in the network is not specified except the EcoNet Smart Thermostat should be at one end of the network. The EcoNet Smart Thermostat has a six-terminal connector labeled R, C, E1, E2, S1 and S2.

Terminal Function
R Power – 24 VAC
C Common / Ground – 24 VAC
E1 EcoNet Communications Bus Wire 1
E2 EcoNet Communications Bus Wire 2
S1 (optional) Analog Remote Temperature Sensor Input
S2 (optional) Common/Ground – 24 VAC

EcoNet UETST800SYS Smart Thermostat - Terminal

Example of Smart Thermostat connection with HVAC and Water Heater unit. Please note this is an example only, and the ordering network can change as long as it is daisy chained.

Electrical Specifications

  • Input Voltage ………… 22 VAC to 26 VAC (24 VAC typical)
  • AC Line Frequency … 50/60 Hz
  • WiFi……………………802.11 b/g/n 2.4 GHz

(OPTIONAL) Shielded Wire
If the thermostat wiring will be located near or in parallel with high voltage wiring, cable TV, Ethernet wiring or radiofrequency equipment, then shielded thermostat wire can be used to reduce or eliminate potential interference.
The shield wire should be connected to the C terminal, or ground, at the indoor unit only. The shield wire from all of the thermostat runs should be attached together and only grounded at the indoor unit.
The shield wire should NOT be connected to any terminal at the smart thermostat. Connecting the shield to ground at  more than one location can cause current loops in the shield, reducing shield effectiveness.

Mounting EcoNet Smart Thermostat

  1. Turn off all power to equipment (e.g. furnace or air handler and outdoor unit).

  2. If an existing thermostat or control is being replaced:
    a Remove existing control from wall.
    b Disconnect wires from existing control.

  3. Place the provided ferrite toroid around the thermostat wires and nest in the drywall. It is suggested to place a zip tie on the thermostat wire to prevent the ferrite toroid from sliding too far back. (See Fig. 1)
    Note: A ferrite toroid is a magnetic core made of ferromagnetic material. It is used for its properties of high magnetic permeability coupled with low electrical conductivity to help reduce radio frequency emissions that can interfere with other devices.

  4. Position the back plate of your EcoNet Smart Thermostat on your wall, using the built-in level to make sure it’s straight. Mark the mounting holes on your wall in pencil.

  5. Drill mounting holes for the drywall anchors and insert.
    Note: It is recommended you fill the hole around the thermostat wires with light insulation to prevent draft.

  6. Route wires through hole in wall plate plastic. Use the screws provided to secure the back plate to the wall. (See Fig. 2)

  7. Match and connect thermostat wires to proper terminals on back plate. (See Fig. 3)
    Note the wire color used for each terminal, as it is good practice to use the same wire color on identical termination points on the indoor and outdoor units.

  8. The wires from the wall should plug easily into the terminal blocks. To release a wire, press down on the lever.
    When installed correctly, the release lever of the terminal block will lower to indicate engagement.

  9. Push any excess wire back into the wall. Seal hole in wall to prevent any air leaks. Leaks can affect operation.

  10. Attach EcoNet Smart Thermostat to the secured wall plate using alignment guides. (See Fig. 4)

  11. Perform installation of all other system equipment.

  12. Turn power to equipment back on.
    Note: To avoid nuisance alarms, power outdoor unit prior to indoor unit.

EcoNet UETST800SYS Smart Thermostat - equipment

Wiring Remote Temperature Sensor

The EcoNet Smart Thermostat is optimized to work with the April Aire 8051 Temperature Sensor (10K thermistor).
Use the S1 and S2 terminals on the wall plate terminal block. Only one remote temperature sensor can be supported.

Go to Menu > Settings > Basic > Room Sensor Selection. You can choose to have the system function based on the temperatures measured by the internal sensor of the thermostat, the remote sensor or the average between the two sensors.

The following table shows the correct resistance at various ambient temperatures without the sensor wires attached to the thermostat.

Temperature (°F Resistance (kΩ)
30 34.6
40 26.1
50 19.9
60 15.3
70 11.9
80 9.4
90 7. 4
100 5.9

Installer Settings

EcoNet UETST800SYS Smart Thermostat - Temperature 2To enter the Installer Settings menu, select Menu > Settings, then tap and hold on “Installer” on the bottom right of the screen for five seconds.

Furnace Settings

Go to Menu > Settings > Installer (tap and hold) > Furnace.

LED Display Orientation – Flips the furnace’s LED diagnostic display so it is readable in the upflow or downflow position.
Furnace Blower Off Delay – 90 (default), 120, 150, 180 seconds. Amount of time the blower will run after a furnace heating call has ended.
Hi Heat Airflow Adjust – This setting will adjust the heat gain of the second stage or high stage of the two-stage furnace. There are five optional settings to choose from. The default is ‘None’.

  • Highest Airflow: Will decrease the second stage Midpoint heat rise -12˚F by increasing the CFM even higher
  • Higher Airflow: Will decrease the second stage Midpoint heat rise -7˚F by increasing the CFM
  • None: Nominal CFM and heat rise across the furnace
  • Lower Airflow: Will increase the second stage Midpoint heat rise +7˚ by lowering the CFM
  • Lowest Airflow: Will increase the second stage Midpoint heat rise +12˚ by lowering the CFM even lower

Lo Heat Airflow Adjust – This setting will adjust the heat gain of the first stage or the low stage of the two-stage furnace. There are five optional settings to choose from. The default is ‘None’.

  • Highest Airflow: Will decrease the first stage Midpoint heat rise -12˚F by increasing the CFM even higher
  • Higher   Airflow: Will decrease the first stage Midpoint heat rise by -7˚F by increasing the CFM
  • None: Nominal CFM and mid heat rise across the furnace
  • Low   Airflow: Will increase the first stage Midpoint heat rise +7˚ by lowering the CFM
  • Lowest Airflow: Will increase the first stage Midpoint heat rise +12˚ by lowering the CFM

G Input Fan Control – Off (default), Low, Medium Lo, Medium, Medium High, High: airflow to run if the G terminal is activated. To be used for add-on accessories (like ventilators) that are wired to the furnace G terminal and wish to run the blower.

Two auxiliary inputs (AUX1 and AUX2) are provided on the communicating gas furnace control for external control of the system (see the furnace installation instructions for additional details). These inputs can be configured as normally closed or normally open when used in conjunction with the AUX Common. These inputs can be used for field accessories such as smoke detectors, freeze stats, etc. The inputs are configured by the installer as follows:

AUX Input #1 or 2 Configured – N.O. (Normally Open) or N.C. (Normally Closed): setting to activate the input to the furnace control IFC (see the furnace installation instructions).

  • If Normally Open is selected, when the AUX #1 or 2 input is connected to AUX Com by a closed switch (e.g. drain switch, freeze switch, etc.) the user selected actions will occur.
  • If Normally Closed is selected, when the AUX #1 or 2 input is disconnected to AUX Com by an open switch the user selected actions will occur.

User Selected Action:

  • Off (This is the default setting. These inputs are turned off)
  • Float Switch Alarm (shutdown cooling with an active alarm)
  • Shutdown (This shuts indoor and outdoor units down, no alarm)
  • Shutdown Cool (In cooling mode this shuts down the outdoor unit, no alarm)
  • HP Heat Lockout (In heating mode this shuts down the outdoor unit, no alarm)
  • Furnace Heat Lockout (In heating mode this shuts down the gas furnace, no alarm)

EcoNet UETST800SYS Smart Thermostat - Figure 52

Filter Type – Media, Electronic Air Cleaner (EAC) or both. The filter type selected will drive the air filter service reminder experience.
Fuel Type – Natural gas or propane.

Note: This only adjusts the EcoNet Smart Thermostat’s control settings and does not convert the actual Gas Furnace to operate with Propane. You must use the proper orifice kit for the model Furnace installed.

Elevation – This is the elevation at or above sea level.

AC/HP Settings

Go to Menu > Settings > Installer (tap and hold) > AC/HP.

Outside Unit Selection – Chooses outdoor unit type:

  • Non-communicating – Allows you to manually enter settings for your outdoor unit. If “non-communicating” outdoor unit is selected, change the type (AC or HP), number of stages (1 or 2) and size (Tons) to match the Outdoor Unit information.
  • EcoNet (locked) – Displays “EcoNet” if a communicating EcoNet Enabled outdoor unit is discovered. The selection cannot be changed (locked).
  • None – Lets the system know that there is no outdoor unit present.

Note: Outside Unit Selection is only applicable for furnace installations.
Var-Speed RPM Clamp – Allows reduction of the maximum compressor speed. Can be used to reduce outdoor unit operating noise or indoor blower airflow. This will also reduce the operating capacity.
Cool/Heat Airflow Adjust – Controls airflow adjustment in cooling and heat pump heating, None (default), High (+10%), Low (-10%).
Utility Input Enabled? – If the system is using a “load shedding” device provided by the utility company set to ‘Yes’. The device must be connected to terminal U2 & U on the VSODU. Once the dry contacts are connected (non- powered) between U2 and U, hange the setting to ‘Yes’. When set to ‘Yes’ the system will not start the condenser when the connection from U2 to U is open.
Heat Source – Allows selection of using just the furnace, or heat pump, as the sole heat source in a dual-fuel installation. If “Both” is selected, the system will stage up and down normally using the heat pump for initial heat stages, and then the furnace as auxiliary heat.
Furnace Locked Out Above – Select the outside temperature above which the furnace or supplemental electric heat will not run when matched with a heat pump. The default is disabled and the temperature can be adjusted between 0-55°F.
Heat Pump Locked Out Below – Selects the outside temperature below which the Heat Pump will not operate and your system will rely exclusively on the furnace or auxiliary heat source. This should be determined by evaluating the regions Heat Pump Balance point. If a non-communicating outdoor unit is paired with a Econet enabled furnace an OAT sensor (RXGY-J02) or the Econet internet sensor option must be used to lock out the heat pump when only furnace operation is desired.

Note: A difference of two degrees will be enforced between the furnace and heat pump. Lockout temperatures will be based off the outdoor temperature sensor connected to the outdoor unit and NOT off the temperature provided under weather. In some  instances internet connections may be intermittent and an OAT sensor would be the most valid option.

Thermostat Settings

Go to Menu > Settings > Installer (tap and hold) > Thermostat.

Thermostat Brand – The EcoNet Smart Thermostat will automatically populate when the system starts up by reading the equipment’s model data card.
Aux. Heat Hold Off Time – This setting is designed to keep the auxiliary heat off for a duration of time determined by the user. The time periods are:

  • Auto: The thermostat will energize Aux Heat once the temperature has reached 1 full degree beyond the heat set point. Also if the heating system is not maintaining the set point using the heat pump alone.
  • 1-60 min: The number of minutes the system will keep the Aux Heat from coming on even when the space temperature goes beyond 1 degree.

Filter Check Hour – The time of day when the EcoNet Smart Thermostat will check the air filter status.

Anticipator – Gives the user the ability to accurately control the system from overshooting in the Heating and the lag of delivering conditioned air in the cooling mode. When set to 0 the system will use the factory default and recommended rate of equipment cycling to maintain comfort. Increasing the number will slow down the system, causing longer cycles. Reducing the number will make the system react quicker, shortening the equipment cycle.

Air Handler Settings

Go to Menu > Settings > Installer (tap and hold) > Air Handler.

Electric Heater Size – If electric strip heaters are installed in the air handler you will need to select the appropriate size.
Electric   Heat Airflow Select – Four choices available. Refer to air handler installation instructions for air flow settings.

See pages 28-29 for the G Input and AUX Input details. These settings are the same for both furnace and air handler.

Caring for your Thermostat

Cleaning
You can clean your thermostat screen by lightly spraying water on the provided lens cloth or a clean microfiber cloth. Wipe the surface of the screen with the dampened cloth. It is recommended you first lock the screen (Menu > Settings > Basic > Screen Lock set to ‘Yes’)
Note: Never spray any liquids directly onto your EcoNet Smart Thermostat.

Rebooting
You can reboot your EcoNet Smart Thermostat by cycling power to the thermostat. Rebooting will not alter programming, settings or configuration options.

Resetting the Thermostat

At some point during the life of your EcoNet Smart Thermostat you may want to quickly restore it to the default state. First, enter the Installer Settings menu by selecting Menu > Settings, then tap and hold on “Installer” on the bottom right of the screen for five seconds. Once in the Installer menu, tap Defaults, view the warning and tap Enter to restore all settings to factory default.

Note: This will reset all settings including a programmed schedule, date and time to factory default settings.

How do I connect a ventilator (HRV or ERV) to an EcoNet HVAC system?
One must use the ventilator’s wall control in the traditional manner, except only wire the ventilator control to the G terminal of the furnace (do not wire to the Y or W terminals). In the EcoNet furnace setup menu, change the G Input Fan Control to a fan speed that is desirable to run with the ventilator. The EcoNet system monitors the furnace G terminal, and will turn on the fan when requested by the G terminal signal (when it is not heating or cooling).

Regulatory and Warranty Information

FCC Compliance Statement
Compliance Notice – This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

—Reorient or relocate the receiving antenna
—Increase the separation between the equipment and receiver
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
—Consult the dealer or an experienced radio/TV technician for help

This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Change or modifications that are not expressly approved by the manufacturer could void the user’s authority to operate the equipment.

RF Exposure Information
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 8 inches during normal operation.

Industry Canada (IC) Compliance Notice
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the interference-causing equipment standard entitled: “Digital Apparatus,” ICES-003 of the Canadian Department of Communications.
This device complies with Industry Canada license-exempt RSS standard(s).

Operation is subject to the following conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

This Class B digital device complies with Canadian ICES-003.

EcoNet Logo In keeping with its policy of continued progress and product
improvement, Ruud reserves the right to make changes without notice.
Printed in the U.S.A. • 9/22 Form No. M22-1025NA-REV 1

Documents / Resources

| EcoNet UETST800SYS Smart Thermostat [pdf] User Guide
UETST800SYS Smart Thermostat, UETST800SYS, Smart Thermostat, Thermostat
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals