KLARSTEIN 10032842 Laurel 90 Wall Cooker Hood User Manual

June 13, 2024
Klarstein

klarstein-logo

KLARSTEIN 10032842 Laurel 90 Wall Cooker Hood

Product Information

The product is a range hood, also known as a Dunstabzugshaube, Campana extractora, Hotte aspirante, Cappa aspirante, or Afzuigkap. It is manufactured by Laurel and has the following article numbers: 10032842, 10033767, 10033768, 10033769. The range hood operates on a power supply of 220-240 V ~ 50/60 Hz.

Product Usage Instructions

Safety Instructions

Before installation, it is important to read and follow the safety instructions provided in the user manual.

Installation

  1. Prepare the installation by gathering the necessary tools and materials.
  2. Use 4 mm x 30 mm screws to attach the bracket.
  3. Refer to the dimensions provided for proper installation.
  4. Install the chimney according to the instructions.
  5. Attach the one-way valve to the air outlet of the range hood and connect the exhaust hose to the one-way valve.
  6. If desired, install an activated carbon filter (not included).

Button Functions
Refer to the user manual for detailed information on the functions of each button on the range hood.

Cleaning and Care
Regularly clean the grease filters and replace them if necessary. Follow the instructions provided in the user manual for proper cleaning procedures. Additionally, refer to the manual for instructions on replacing the lamp.

Troubleshooting
If any issues occur with the range hood, consult the troubleshooting section in the user manual for guidance on identifying and resolving common problems.

Product Data Sheet
The product complies with Regulation (EU) No. 65/2014 and includes information on energy efficiency, airflow, noise emissions, and power consumption. Refer to the data sheet for specific values related to the article numbers mentioned.

Notes on Environmental Protection
Follow the provided notes on environmental protection to minimize the environmental impact of the product’s use.

Disposal Considerations

When disposing of the product, follow the instructions provided in the user manual to ensure proper disposal methods are followed.
Minimize waste generation whenever possible.

Manufacturer & Importer (UK)
The product is manufactured and imported by Chal-Tec Fulfillment GmbH, located at Norddeutschlandstr. 3, 47475 Kamp-Lintfort.

Dear Customer,
Congratulations on purchasing this device. Please read the following instructions carefully and follow them to prevent possible damages. We assume no liability for damage caused by disregard of the instructions and improper use. Scan the QR code to get access to the latest user manual and more product information.

TECHNICAL DATA

Item number 10032842, 10033767,10033768,10033769
Power supply 220-240 V ~ 50/60 Hz

Note: You can purchase an activated carbon filter separately for this cooker hood under item number 10032844. Please visit our website: www.klarstein.co.uk

SAFETY INSTRUCTIONS

  • Thank you for purchasing this cooker hood. Please read the instruction manual carefully before you use the cooker hood, and keep it in a safe place.
  • The installation work must be carried out by a qualified electrician or competent person. Before you use the cooker hood, make sure that the voltage (V) and the frequency (Hz) indicated on the cooker hood are exactly the same as the voltage and the frequency in your home.
  • The manufacturer and the agent will not bear any responsibility for the damage caused by inappropriate installation and usage.
  • Children under the age of 8 must not use the cooker hood.
  • The appliance is not intended for commercial use, but only for household and similar environments.
  • The cooker hood and its filter mesh should be cleaned regularly in order to keep it in good working order.
  • Before cleaning, switch the power off at the main supply.
  • Clean the cooker hood according to the instruction manual and keep the cooker hood from the danger of burning.
  • Prohibit putting the cooker hood by fire.
  • If the appliance does not function normally, contact the manufacturer or a specialist company.
  • This device may be only used by children 8 years old or older and persons with limited physical, sensory and mental capabilities and/or lack of experience and knowledge, provided that they have been instructed in use of the device by a responsible person who understands the associated risks.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • If the range hood is used at the same time as appliances burning gas or other fuels, the room must be adequately ventilated.
  • Do not flambé under the range hood. Accessible parts may become hot when used with cooking appliances.

Important hints on installation

  • The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
  • Regulations concerning the discharge of air have to be fulfilled.
Important notes about the extraction mode

WARNING

Risk of poisoning from exhaust gases sucked back. Never operate the device in extraction mode simultaneously with an open flue appliance when there is not adequate airflow guaranteed.
Open flue combustion equipment (for example, gas, oil, wood or coal-fired heaters, tankless water heaters, water heaters) pulls combustion air from the room and runs it through an exhaust pipe or chimney to the outside. In the extraction mode, indoor air is removed from the kitchen and the adjacent rooms – without sufficient air intake this creates a vacuum. Toxic gases from the chimney or extraction flue can thereby be sucked back into the living spaces.

  • Always ensure that a sufficient supply of fresh air is guaranteed and that the air can circulate.
  • An air supply/extractor box alone does not ensure compliance with the limit value.
    Safe operation is only possible when the negative pressure in the room where the appliance is located does not exceed 4 Pa (0.04 mbar). This can be achieved when the air required for combustion can flow through openings that are not closable, for example in doors, windows, in conjunction with an air supply/extractor box or through other technical measures. In any case, consult a qualified chimney sweep who can assess the entire ventilation of your house and propose appropriate measures for adequate ventilation.
    If the hood is used exclusively in the recirculation mode, unrestricted operation is possible.

Important note on disassembly of the device

  • Disassembly is similar to installation/assembly in reverse order.
  • Take a second person to help you during disassembly to avoid injuries.

INSTALLATION

Preparation
If you have an outlet to the outside, your cooker hood can be connected as below picture by means of an extraction duct (enamel, aluminium, flexible pipe or inflammable material with an interior diameter of 150mm)

  • Before installation, turn the unit off and unplug it from the outlet.
  • The cooker hood should be placed at a distance of 65~75cm above the cooking plane for best effect.

Installation (Vent outside)

Note: When the range hood and appliance supplied with energy other than electricity are simultaneously in operation, the negative pressure in the room must be not exceed 4 Pa (4 x 10-5 Bar).

KLARSTEIN-10032842-Laurel-90-Wall-Cooker-Hood-2

KLARSTEIN-10032842-Laurel-90-Wall-Cooker-Hood-3

Dimensions

KLARSTEIN-10032842-Laurel-90-Wall-Cooker-Hood-4

KLARSTEIN-10032842-Laurel-90-Wall-Cooker-Hood-5

Chimney installation

Put the upper chimney into lower chimney. Then pulling out the upper chimney upwards. Adjust to reach the height required. Measure the appropriate height and dill 2×8 mm holes to accommodate the plate. Screw and tighten the upper wall with 2 screws provided.

There are 2 methods for installation the chimney cover (see below pic for reference).

KLARSTEIN-10032842-Laurel-90-Wall-Cooker-Hood-7

  1. After drilled the 2 holes and fixed the hook, hang the chimney cover by matching the both side lock (Pic1).
  2. After drilled the 2 holes and fixed the hook, install the chimney cover by locking with 2 screws in both side holes (Pic2).
Installation (Vent inside)

If you do not have an outlet to the outside, exhaust pipe is not required and the installation is similar to the one show in section “Installation (Vent outside)”.

Installing the Carbon Filter

Note: You can purchase an activated carbon filter separately for this cooker hood under item number 10032844. Please visit our website: www.klarstein.co.uk

1 2
Activated carbon filter can be used to trap odours. In order to install the

activated carbon filter, the grease filter should be detached first. Press the lock and pull it downward.
3
| Plug the activated carbon filter into the unit and turn it in clockwise direction. Repeat the same on the other side.

Make sure the filter is securely locked. Otherwise, it would loosen and cause dangerous. When activated carbon filter attached, the suction power will be lower.

BUTTON FUNCTIONS

Note: On working condition, the display would off if 2 minutes without pressing, press again, the key lights on.

CLEANING AND CARE

Monthly Cleaning for Grease Filter
Clean the filter every month can prevent any risk of fire. The filter collects grease, smoke and dust, so the filter is directly affecting the efficiency of the cooker hood. If not cleaned, the grease residue (potential flammable) will saturate on the filter. Clean it with household cleaning detergent.

Annual Cleaning for Activated Filter
Apply solely to unit that installed as a recirculation unit (not vented to the outside).
This filter traps odours and must be replaced at least once a year depending on how frequent the cooker hood used.

Replacing Bulbs

  • Switch the unit off and unplug the appliance.
  • Remove the lamp cover by unscrewing the 2 screws.
  • Unscrew the incandescent bulb. Replace with the same type and rated bulb.

TROUBLESHOOTING

Fault Cause Solution
Light on, but fan does not work The fan blade is jammed. Switch of the unit

and repair by qualified service personnel only.
The motor is damaged.
Both light and fan do not work| light bulb burn.| Replace the bulb with correct rating.
Power cord looses.| Plug in to the power supply again.
Serious Vibration of the unit| The fan blade is damaged.| Switch of the unit and repair by qualified service personnel only.
The fan motor is not fixed tightly.
The unit is not hung

properly on the bracket.

| Take down the unit and check whether the bracket is in proper location.
Suction performance not good| Too long distance between the unit and the cooking plane| Readjust the distance to 65-75 cm

PRODUCT DATA SHEET

Information according to Regulation (EU) No. 65/2014
Measurement and calculation methods according to EN 61591:1997+A1:2006+A2:20 11+A11:2014+A12:2015

Item number 10032842, 10033767, 10033768, 10033769
Description Symbol
Annual Energy Consumption AEChood
Energy Efficiency class  
Fluid Dynamic Efficiency FDEhood
Fluid Dynamic Efficiency class  
Lighting Efficiency LEhood
Lighting Efficiency class  
Grease Filtering Efficiency GFEhood
Grease Filtering Efficiency class  

air flow at minimum and maximum speed in normal use, intensive or boost excluded|  | 191,07 / 347,74| m³/h
air flow at intensive or boost setting|  | –| m³/h
airborne acoustical A-weighted sound power emissions at minimum and maximum speed available in normal use|  | 54 / 64| dB
airborne acoustical A-weighted sound power emissions at intensive or boost setting|  | –| dB
power consumption in off mode| Po| 0| W
power consumption in standby

mode

| Ps| –| W
Contact details| Chal-Tec GmbH, Wallstraße 16, 10179, Berlin, Germany

NOTES ON ENVIRONMENTAL PROTECTION

  • During cooking, make sure that there is sufficient air supply so that the cooker hood can operate efficiently and with low operating noise.
  • Adjust the fan speed to the amount of steam produced during cooking. Use the intensive mode only when necessary. The lower the fan speed, the less energy is consumed.
  • If large amounts of steam are produced during cooking, select a higher fan speed in good time. If the cooking steam has already dispersed in the kitchen, the cooker hood must be operated longer.
  • Switch off the cooker hood when you no longer need it.
  • Switch off the lighting when you no longer need it.
  • Clean the filter at regular intervals and replace it if necessary to increase the effectiveness of the ventilation system and prevent fire hazards.
  • Always put the lid on when cooking to reduce cooking steam and condensation.

DISPOSAL CONSIDERATIONS
If there is a legal regulation for the disposal of electrical and electronic devices in your country, this symbol on the product or on the packaging indicates that this product must not be disposed of with household waste. Instead, it must be taken to a collection point for the recycling of electrical and electronic equipment. By disposing of it in accordance with the rules, you are protecting the environment and the health of your fellow human beings from negative consequences. For information about the recycling and disposal of this product,please contact your local authority or your household waste disposal service.

MANUFACTURER & IMPORTER (UK)
Manufacturer:
Chal-Tec GmbH, Wallstrasse 16, 10179 Berlin, Germany.
Importer for Great Britain:
Berlin Brands Group UK Limited
PO Box 42
272 Kensington High Street
London, W8 6ND
United Kingdom

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals