ELATION PROFESSIONAL FRESNEL 8 CW 350W Warm White LED 8 Inch Fresnel User Manual

June 13, 2024
ELATION PROFESSIONAL

ELATION PROFESSIONAL logo FRESNEL 8 CW
User Manual

FRESNEL 8 CW 350W Warm White LED 8 Inch Fresnel

©2023 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non- ELATION brands and product names are trademarks or registered trademarks of their respective companies.

ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.

Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040 323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands +31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu
Elation Professional Mexico | AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000 +52 728-282-7070

DOCUMENT VERSION

https://qrs.ly/23cbwjh

Due to additional product features and/or enhancements, an updated version of this document may be available online. Please scan the QR Code with your mobile device or visit www.elationlighting.com for the latest revision/update of this manual, before installation and/or programming.

Date| Document Version| Software Version| DMX Channel Mode| Notes
---|---|---|---|---
03/02/19| 1.0| 1.02| 1 / 2 / 3 / 4 / 5 Ch| Initial release
10/02/20| 1.1| N/C| No Change| Updated box contents, specs, and refresh frequency
05/28/21| 1.2| N/C| No Change| Added standalone instructions to System Menu
06/15/23| 1.3| N/C| No Change| Updated General Info, Installation Guidelines, System Menu, Dimmer Curves, Specifications; added Accessory Installation, Software Updates

GENERAL INFORMATION

INTRODUCTION
This fixture has been designed to perform reliably for years when the information in this manual is followed. Please read and understand all the instructions and guidelines carefully and thoroughly before operating this unit. This manual contains important  information regarding safety, installation, use, and maintenance. This unit is intended for use by trained professionals only, and is not suitable for private use.

UNPACKING
Every device has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton is damaged, carefully inspect the device for damage, and be sure all accessories necessary to install and operate the device have arrived intact. In the event that damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not return this device to your dealer without first contacting customer support. Please do not discard the shipping carton in the trash. Please recycle whenever possible.

BOX CONTENTS
Barn Door (x1)
Gel Frame (x1)
Power Cable (x1)
Barn Door Safety Cable – USA Only (x1)

CUSTOMER SUPPORT
Contact ELATION Service for any product related service and support needs.
Also visit forums.elationlighting.com with questions, comments, or suggestions.

ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST 323-582-3322 | Fax 323-832-9142 | support@elationlighting.com

ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET +31 45 546 85 63 | Fax +31 45 546 85 96 | support@elationlighting.eu

REPLACEMENT PARTS please visit parts.elationlighting.com

IMPORTANT NOTICE! THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF, AS DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/ OR REPAIRS.

LIMITED WARRANTY (USA ONLY)

A. Elation Professional hereby warrants, to the original purchaser, Elation Professional products to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
B. For warranty service, send the product only to the Elation Professional factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional shall have no liability what so ever for loss and/or or damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which Elation Professional concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professional factory unless prior written authorization was issued to purchaser by Elation Professional; if the product is damaged because not properly maintained as set forth in the product instructions, guidelines and/ or user manual.
D. This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Elation Professional will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional. All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that effect.
E. Elation Professional reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product.
G. This warranty is the only written warranty applicable to Elation Professional products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.

WARRANTY RETURNS
All returned service items whether under warranty or not, must be freight pre- paid and accompanied by a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper and included in the shipping container. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. Items returned without an R.A. number clearly marked on the outside of the package will be refused and returned at customer’s expense. You may obtain an R.A. number by contacting customer support.

SAFETY GUIDELINES

This fixture is a sophisticated piece of electronic equipment. To guarantee smooth operation, it is important to follow all instructions and guidelines in this manual. Elation Professional is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufacturer’s warranty and increase the risk of damage and/or personal injury.

**** PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED.
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY

REPAIRS YOURSELF, AS DOING SO WILL VOID YOUR
MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS DEVICE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
| DO NOT PLUG THIS UNIT INTO A DIMMER PACK!
NEVER OPERATE THIS UNIT WITH THE CASING REMOVED!
DISCONNECT POWER BEFORE PERFORMING MAINTENANCE!
NEVER TOUCH DURING OPERATION, AS FIXTURE SURFACES MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
| NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
RETINA INJURY RISK – MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
| FOR USE IN INDOOR OR DRY LOCATIONS ONLY!
DO NOT EXPOSE TO RAIN AND/OR MOISTURE!

  • DO NOT TOUCH the fixture housing during operation.
  • Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before servicing.
  • DO NOT shake fixture and avoid brute force when installing and/or operating fixture.
  • DO NOT operate fixture if the power cord is frayed, crimped, damaged, and/or if any of the power cord connectors are damaged and do not insert into the fixture securely with ease.
  • NEVER force a power cord connector into the fixture. If the power cord or any of its connectors are damaged, replace it immediately with a new one of the same rating.
  • DO NOT block any air ventilation slots.
  • All fan and air inlets must remain clean and never blocked.
  • Allow approx. 6” (15cm) between fixture and other devices or a wall for proper cooling.
  • When installing fixture in a suspended environment, always use mounting hardware that is no less than M10 x 25 mm, and always install fixture with an appropriately rated safety cable.
  • Always disconnect fixture from main power source before performing any type of service and/or cleaning procedure.
  • Only handle the power cord by the plug end, and never pull out the plug by tugging the wire portion of the cord.
  • During the initial operation of this fixture, a light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time.
  • Consistent operational breaks will ensure fixture will function properly for many years.
  • ONLY use the original packaging and materials to transport the fixture for service.

MAINTENANCE GUIDELINES

CLEANING
DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!

Frequent cleaning is recommended to ensure proper function, optimized light output, and an extended life. The frequency of cleaning depends on the environment in which the fixture operates: damp, smoky, or particularly dirty environments can cause greater accumulation of dirt on the fixture’s optics. Clean periodically with a soft cloth to avoid dirt/debris accumulation.

NEVER use alcohol, solvents, or ammonia-based cleaners.
MAINTENANCE
Regular inspections are recommended to ensure proper function and extended life. There are no user serviceable parts inside this fixture. Please refer all service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from an authorized Elation dealer.
Please refer to the following points during routine inspections:

  • A detailed electrical check by an approved electrical engineer every three months, to make sure the circuit contacts are in good condition and prevent overheating.
  • Be sure all screws and fasteners are securely tightened at all times. Loose screws may fall out during normal operation, resulting in damage or injury as larger parts could fall.
  • Check for any deformations on the housing, color lenses, rigging hardware, and rigging points (ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter into the fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person(s).
  • Electric power supply cables must not show any damage, material fatigue, or sediments.

NEVER remove the ground prong from the power cable.

FIXTURE OVERVIEW

ELATION PROFESSIONAL FRESNEL 8 CW 350W Warm White LED 8 Inch Fresnel -
FIXTURE OVERVIEW

1. 3pin DMX In
2. 5pin DMX In
3. 5pin DMX Out
4. 3pin DMX Out
5. Power In| 6. Power Out
7. USB Software Update Port
8. OLED Control Menu Display
9. Mode Button
10. Up Button| 11. Down Button
12. Enter Button
13. Manual Dimming Control
14. Manual Zoom Control
15. Fuse
---|---|---

INSTALLATION INSTRUCTIONS

FLAMMABLE MATERIAL WARNING
Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyrotechnics.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or installations.
USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE. CHECK SILK SCREEN FOR MAX AMPS.
DO NOT PERFORM THE INSTALLATION YOURSELF IF YOU ARE NOT QUALIFIED TO DO SO!

Fixture MUST be installed following all local, national, and country commercial electrical and construction codes and regulations.
Before rigging/mounting a single fixture or multiple fixtures to any metal truss/structure or placing the fixture(s) on any surface, a professional equipment installer MUST be consulted to determine if the metal truss/structure or surface is properly certified to safely hold the combined weight of the fixture(s), clamps, cables, and accessories.
Ambient operating temperature range is 14°F to 113°F (-10°C to 45°C). Do not operate this fixture when ambient temperature falls outside of this range.
Fixture(s) should be installed away from walking paths, seating areas, or areas where unauthorized personnel might reach the fixture by hand.
NEVER stand directly below the fixture(s) when rigging, removing, or servicing.
Overhead fixture installation must always be secured with a secondary safety attachment, such as an appropriately rated safety cable that can support at least 10 times the weight of the fixture.
Allow approximately 15 minutes for the fixture to cool down before serving.

CLAMP INSTALLATION
The fixture features an adjustable mounting yoke and safety cable rigging point, as shown in the illustration below. When mounting this fixture to a truss, always secure an appropriately rated mounting clamp (not included) to the yoke using an M10 screw, and attach a SAFETY CABLE to the designated rigging point.ELATION PROFESSIONAL FRESNEL 8 CW 350W Warm White LED 8 Inch
Fresnel - CLAMP INSTALLATION

ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THAT THE FIXTURE WILL NOT FALL IF THE CLAMP FAILS.

RIGGING
Overhead rigging requires extensive experience, calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the fixture itself, among other skills. If you lack these qualifications, do not attempt to perform the installation yourself, as improper installation can result in bodily injury. The fixture is fully operational in the specific mounting positions illustrated below.ELATION PROFESSIONAL FRESNEL 8 CW 350W Warm White LED 8 Inch Fresnel -
RIGGING

ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THAT THE FIXTURE WILL NOT FALL IF THE CLAMP FAILS.

ACCESSORY INSTALLATION

GEL FRAME AND BARNDOOR
The fixture has 2 slots on the front, which can be used for the installation of the Gel Frame and Barn Door. The first, smaller slot is for the Gel Frame, and the second, larger slot is for the Barn Door. The fixture also has a top lock that secures these accessories in place. Please note that the Barn Door requires its own, separate safety cable, which is included.ELATION
PROFESSIONAL FRESNEL 8 CW 350W Warm White LED 8 Inch Fresnel -
ACCESSORY

  1. Lift the lock on top of fixture and insert the Gel Frame into the first slot (closest to the lens of the fixture).
  2. Insert the Barn Door into the second slot.
  3. Lower the lock on top of the fixture to secure both the Gel Frame and Barn Door in place.
  4. Secure the included mini SAFETY CABLE to the Barn Door and top lock.

SYSTEM MENU

The fixture features an easy to navigate system menu. The control panel (see image below) is located on the back of the fixture and provides access to the main system menu where all necessary system adjustments are made. During normal operation, pressing MODE button once will access the fixture’s main menu. Once in the main menu, you can navigate through the different functions and access the sub-menus with the UP and DOWN buttons. Once you reach a field that requires adjusting, press the ENTER button to activate that field, then use the UP and DOWN buttons to adjust the field. Pressing the ENTER button once more will confirm your setting. You may exit the main menu at any time without making any adjustments by pressing the MODE button.
Note: To access the LCD Menu Control Display when locked, press and hold the MODE button for 3 seconds. The LCD Menu Control Display will shut OFF automatically about 1 minute of inactivity.

STANDALONE
Press the MODE button to access the fixture’s main menu. Use the UP and DOWN buttons to navigate to DMX Settings and press the ENTER button. Navigate to No DMX Status and press the ENTER button. Navigate to Standalone and press the ENTER button.

SOFTWARE UPDATES
The unit’s control panel also includes a USB service port that can be used to perform software updates to the unit, using either a USB stick or a C-Loader II software updater device. Please refer to the Software Updates section of this manual for detailed information.

ELATION KL Fresnel 8 CW System Menu

Supports Software Versions: 1.02
ADDRESS| Set DMX Address| 001 – xxx| Set DMX address settings
USERMODE| User Mode| Dimmer| Set DMX channel mode
Dimmer 16bit
3CH
Standard
Extended
FUNCTION| Status| Lost DMX| Hold / Black| Function if DMX signal lost or interrupted
LCD Set| Display| On / Off| Turns screen off after 30sec of inactivity; only operates when DMX is connected
Key Lock| On / Off| Lock control panel keys
Flash| On / Off| Display flahes when DMX not connected
Invert| On / Off| Flip screen display orientation
Temp C/F| C / F| Temperature display units
Dim Mode| Standard| Set dimmer mode
Stage
TV
Architec
Theatre
Stage 2
0s, 0.1s, 0.2s, 0.3s, 0.4s, 0.5s, 0.6s, 0.7s, 0.8s, 0.9s, 1.0s, 1.5s, 2.0s, 3.0s, 4.0s, 5.0s, 6.0s, 7.0s, 8.0s, 9.0s, 10.0s
Disp Set| Addr| Select info to display on screen
Disp Ch
Sec
Fan Set| LED Fan| Auto| Set LED fan speed
High
Low
Dim Curve| Linear| Set dimmer curve mode
Square
Inv Square
S-Curve
Frequen| 900Hz, 1000Hz, 1100Hz, 1200Hz, 1300Hz, 1400Hz, 1500Hz, 2500Hz, 4000Hz, 5000Hz, 10KHz, 15KHz, 20KHz, 25KHz| Set LED refresh frequency
CONTINUED ON NEXT PAGE

SYSTEM MENU

FUNCTION (continued)| USB Data| On / Off| Software update port; contact Elation Service for guidance
---|---|---|---
Primary SW| On / Off| Set unit to primary mode
DFSE| On / Off| Restore factory settings
INFO| Time Info| Current| xxx hours| Fixture run time from power ON
Total| xxx hours| Fixture total run time
Last| xxx hours| Fixture run time since last cleared
Clear Password = 050| On / Off| Reset fixture last run time
Temp Info| LED Temp| xxx C / F| Current LED temperature
Err Info| Error Record 1 ~ 10| Display last 10 error messages
Model Inf| KL F8 CW| Display model name
Software| Software| Vx.xx| Software version
TEST| Reset M| Zoom| Reset zoom motors
Man Ctrl| Dimmer| 000 – 255| Manual control functions
Strobe| 000 – 255
Zoom| 000 – 255
Calibrat| Password = 050| Calibration

DIMMER CURVE MODES

Select desired DIMMER MODE (Standard, Stage, TV, Architectural, Theatre, Stage2).![ELATION PROFESSIONAL FRESNEL 8 CW 350W Warm White LED 8 Inch Fresnel

Dimming Curve Ramp Effect 0 sec Fade Time 1 sec Fade Time
Rise Time (ms) Down Time (ms) Rise Time (ms)

(ms)**
Standard (default)| 0| 0| 0| 0
Stage| 780| 1100| 1540| 1660
TV| 1180| 1520| 1860| 1940
Architectural| 1380| 1730| 2040| 2120
Theatre| 1580| 1940| 2230| 2280
Stage 2| 0| 1100| 0| 1660

ELATION PROFESSIONAL FRESNEL 8 CW 350W Warm White LED 8 Inch Fresnel -
Dimming Curve

MANUAL DIMMING AND ZOOM CONTROL

FEATURE IS DISABLED WHEN DMX INPUT CABLE IS CONNECTED TO FIXTURE! TO USE DIMMING AND ZOOM KNOBS, DISCONNECT DMX CABLE IF CONNECTED.
Follow steps below to enable manual DIMMING and ZOOM control knobs.

  1. Access fixture system menu navigating to Test menu then access ManCtrl sub menu.
    MAIN MENU| SUB MENU| OPTIONS / VALUES| DESCRIPTION
    ---|---|---|---
    Test| Reset M| Zoom| Reset Zoom Motor
    Man Ctrl| Dimmer| Manual Control Func- tions
    Zoom
    Strobe
    Calibrat| Password = 050| Calibrate

NOTE: To access the LCD Menu Control Display when locked/OFF, press and hold the MODE button for 3 seconds.

  1. Select the Strobe menu, then set to a value of 255 (LED On). Exit back out to the fixture system menu.
  2. Unlock the DIMMING knob by pushing down once on the knob, rotate the knob to adjust dimming to the desired level, and push down on the knob once again to lock it. Repeat this process each time a dimming adjustment is needed.
  3. Unlock the ZOOM knob by pushing down once on the knob, rotate the knob to adjust zoom to the desired level, and push down on the knob once again to lock it. Repeat this process each time a zoom adjustment is needed.

LCD DISPLAYELATION PROFESSIONAL FRESNEL 8 CW 350W Warm White LED 8 Inch
Fresnel - LCD DISPLAY

DMX CHANNEL FUNCTIONS AND VALUES

ELATION KL Fresnel 8 CW – DMX Traits

Supports Software Versions: 1.02
CHANNEL| | | DMX VALUES| FUNCTION
Dimmer| Dimmer 16bit| 3Ch| Std| Ext
1| 1| 1| 1| 1| 000 – 255| Dimmer Intensity, 0% to 100%
| 2| | 2| 2| 000 – 255| Dimmer Intensity Fine
| | 2| 3| 3| | Shutter / Strobe
000 – 031| LED Off
032 – 063| LED On
064 – 095| Strobe Effect, slow to fast
096 – 127| LED On
128 – 159| Pulse Effect, slow to fast
160 – 191| LED On
192 – 223| Random Strobe Effect, slow to fast
224 – 255| LED On
2| 3| 3| 4| 4| 000 – 255| Motorized Zoom, small to large
| | | 5| 5| 000 – 255| Motorized Zoom Fine
| | | 6| 6| | Dimmer Modes / Dimmer Delay Times
000 – 020| Standard
021 – 040| Stage
041 – 060| TV
061 – 080| Architectural
081 – 100| Theatre
101 – 120| Stage 2
121| Delay Time 0.0s
122| Delay Time 0.1s
123| Delay Time 0.2s
124| Delay Time 0.3s
125| Delay Time 0.4s
126| Delay Time 0.5s
127| Delay Time 0.6s
128| Delay Time 0.7s
129| Delay Time 0.8s
130| Delay Time 0.9s
131| Delay Time 1.0s
132| Delay Time 1.5s
133| Delay Time 2.0s
134| Delay Time 3.0s
135| Delay Time 4.0s
136| Delay Time 5.0s
137| Delay Time 6.0s
138| Delay Time 7.0s
CONTINUED ON NEXT PAGE

DMX CHANNEL FUNCTIONS AND VALUES

CHANNEL DMX VALUES FUNCTION
Dimmer Dimmer 16bit 3CH
6
139 Delay Time 8.0s
140 Delay Time 9.0s
141 Delay Time 10.0s
142 – 255 Default

for 5sec to set LED refresh rate
000 – 100| Idle
101 – 105| 900 Hz
106 – 110| 1000 Hz
111 – 115| 1100 Hz
116 – 120| 1200 Hz
121 – 125| 1300 Hz
126 – 130| 1400 Hz
131 – 135| 1500 Hz
136 – 140| 2500 Hz
141 – 145| 4000 Hz
146 – 150| 5000 Hz
151 – 155| 10 KHz
156 – 160| 15 KHz
161 – 165| 20 KHz
166 – 170| 25 KHz
171 – 200| Idle
201 – 210| Dimmer Curve Linear (default)
211 – 220| Dimmer Curve Square
221 – 230| Dimmer Curve Inverse Square
231 – 240| Dimmer Curve S-Curve
241 – 255| Idle

SOFTWARE UPDATES

A USB FLASH DRIVE CAN BE USED TO UPDATE THE FIXTURE TO THE LATEST SOFTWARE.
Using a USB Flash Drive loaded with the latest software, insert it into the USB Service Port, then navigate to FUNCTION > USB DATA, and toggle this setting to ON. Contact Elation service for additional instructions, or to obtain a copy of the latest software.
AN ELATION C-LOADER II CAN ALSO BE USED TO UPDATE THE FIXTURE TO THE LATEST SOFTWARE. To order this device, please contact Elation Support for further details.
ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST
323-582-3322 | Fax 323-832-9142 | support@elationlighting.com
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET
+31 45 546 85 63 | Fax +31 45 546 85 96 | support@elationlighting.eu

SPECIFICATIONS

SOURCE
350W Cool White LED Engine, 5,600K, 97CRI
50,000 Hour Average LED Life
May vary depending on several factors including but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control and Dimming.
PHOTOMETRIC DATA
up to 14,000 Total Lumen Output
16,762 LUX 1,557 FC @ 9.8’ (3m) (Min. Zoom)
1462 LUX 136 FC @ 9.8’ (3m) (Max. Zoom)
Zoom Range 11° – 56°
Beam Angle 11° – 56.2°
Field Angle 17.9° – 77°
EFFECTS
Motorized Zoom
Electronic Dimmer and Strobe
Variable 16-bit Dimming Modes and Curves
COLOR
5,600K Cool White LED
CONTROL / CONNECTIONS
Manual and DMX Controlled Dimmer, Shutter and Zoom
Dimmer and Zoom Rotary Dials
(5) DMX Channel Modes (2 / 3 / 3 / 6 / 7)
4 Button Control Panel LCD Menu Display
RDM (Remote Device Management)
3/5pin DMX and IP65 Locking Power In/Out Connection
With Wired Digital Communication Network
SIZE / WEIGHT
Length: 17.5” (445mm)
Width: 12.89” (327.5mm)
Vertical Height: 17.95” (456mm)
Weight: 28.0 lbs. (12.7kg)
ELECTRICAL / THERMAL
AC 100-240V – 50/60Hz
430W Max Power Consumption
5°F to 113°F (-15°C to 45°C)
Power Linking: 3Pcs @ 110V / 6Pcs @ 240V
INCLUDED ITEMS
Gel Frame and Rotating Barn Doors
IP65 Locking Power Cable
APPROVALS / RATINGS
CE | cETLus | IP20

DIMENSIONAL DRAWINGS

ELATION PROFESSIONAL FRESNEL 8 CW 350W Warm White LED 8 Inch Fresnel -
DIMENSIONAL DRAWINGS

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device uses and can radiate radio frequency energy and, if not installed and used in accordance with the included instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following methods:

  • Reorient or relocate the device.
  • Increase the separation between the device and the receiver.
  • Connect the device and the radio receiver to electrical outlets on two separate circuits.
  • Consult the dealer or an experienced radio/TV technician for help.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ELATION PROFESSIONAL User Manuals

Related Manuals