Antari S-600 Yeti High Output Snow Machine User Manual

June 4, 2024
Antari

Antari S-600 Yeti High Output Snow Machine

Introduction

Please read this user manual carefully before operating the machine.
Please put this manual in a place where you can refer to it at any time.
If you encountered any problems, please contact your local Antari dealer for advice and assistance.

Safety Information

| CAUTION!
Please read the following safety information carefully before operating the machine.
This information includes important safeguards about installation, usage and maintenance. Pay attention to all warning labels and instructions in this manual and printed on the machine.
---|---
| DANGER!
Electrical shock
Always connect the machine to correct voltage. It will lead to electrical shock or burned and may cause serious consequences if connecting to incorrect or improper voltage.
| WARNING!
Risk of electrocution
Always connect the machine to a protected circuit and ensure it is properly grounded to avoid risk of electrocution.

※ Damage caused by the disregard of this user manual are not subject to warranty. Antari and its dealer will not accept liability for any resulting defects or problems.

Installation
  • Keep this device dry. This machine is not waterproof. Do not expose the machine to water splashes.
  • Place the machine on a flat surface. Installed in a well ventilated area. Provide at least 50 cm space around the machine.
  • Make sure there are no flammable materials close to the machine while operating. Never add flammable liquid of any kind to the machine.
  • Before connecting the machine to power, always check the voltage indicate on the machine matches to your local AC voltage. Do not use the machine if AC power voltage does not match.
  • If the supply cord is damaged, it must be replaced by a special cord or assembly available from your local Antari dealer for replacement.
  • No user serviceable and modifiable parts inside. Never try to repair this product, an unauthorized technician may lead the machine to damage or malfunction.
  • This product is for indoor use only! Do not expose to rain or moisture. If fluid is spilled, disconnect AC power and clean with a damp cloth. If fluid is spilled onto electronic parts, immediately unplug the machine and contact your local Antari dealer for advice.
  • Pay attention to all warning labels and instructions on the machine before operation
Operation
  • Do not operate the machine with bundled power cables. It could be a fire hazard.
  • Do not operate the machine in an area with unstable voltage. This may burn out internal components and cause machine fail to work.
  • Do not use the machine against human, animal or flame. Make sure there are no flammable materials close to the machine.
  • For adult use only. The machine is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge. Never leave the machine running unattended.
  • Children being supervised not to play with the machine.
  • If you hear a strange sound or experience machine fails to work, stop use it immediately. Turn off and unplug the machine, and contact your local Antari dealer for service.
  • Turn off and unplug the machine while it’s not in use.
  • Make sure the machine is turned off before unplug it.
  • Do not use the machine upside down or tilt it. It may damage the machine and make it malfunction.
  • Before transporting the machine, make sure the fluid tank is completely drained.
  • Snow fluid may present health risks if swallowed. Do not drink snow fluid. Store it securely. In case of eye contact or if fluid is swallowed immediately look for medical advice.
  • Be sure to unplug the machine before filling snow fluid.
  • If the machine fails to work, unplug the machine and stop operation immediately. Contact your local Antari dealer for help.
Grounding Instruction

This appliance must be grounded in the event of malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

DANGER – Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment- grounding conductor. If repair or replacement of the cord or plug is necessary, do not connect the equipment-grounding conductor to a live terminal. Check with a qualified electrician or servicemen if the grounding instructions are not completely understood, or if in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.

This appliance is for use on a nominal 120V circuit and has a grounding plug that looks like the plug illustrated in sketch A in Figure 73.1. A temporary adaptor, which looks like the adaptor illustrated in sketches B and C, may be used to connect this plug to a 2 pole receptacle as shown in sketch B if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet can be installed by a qualified electrician. The green colored rigid ear, lug, and the like, extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover.
Whenever the adaptor is used, it must be held in place by the metal screw.

Package Items

Immediately upon receiving the machine, carefully unpack the carton, check the content to ensure that all parts are present and have been received in good condition. If any parts appear damaged or mishandled from shipping, notify the shipper immediately and retain the packing material for inspection.

Standard Package

1 x S-600 Snow Machine
1 x PowerCon True 1 Power Cord
1 x User Manual or scan QR code on technical label
1 x 5M Fluid Tank Feed Tube with Filter
1 x W-2 Wireless Transmitter (Receiver has been installed onto the machine)
1 x Hanging Bracket

Optional Accessories
Item Code Description
WTR-90 W-2 & W-DMX Receiver & W-DMX-PCB
SC-4 Cable Remote
S-600-BH 5-Liter Bottle Holder

Product Overview

01. Control Panel 06. Wireless Receiver Antenna
02. Fluid Tube Connection 07. SC-4 Remote Connector
03. Main Power Switch 08. Output Nozzle
04. True 1 PowerCon Connector 09. Hanging Bracket
05. XLR 5-Pin DMX Connector 10. Technical Label

Technical Label Information

Read the information on the technical label before operation.
Technical label is attached on one side of control panel.

  1. Model Name
  2. Input Voltage
  3. Frequency
  4. Rated Power
  5. Breaker
  6. QR CODE for User Manual
  7. Serial No.

Snow Fluid

| CAUTION!
Always disconnect from the mains before filling the machine. Never add flammable liquids. If fluid gets inside the machine, please contact your local Antari dealer for service.
---|---

Only use Antari SL-N, SL-AN, SL-H, SL-C, SL-UV fluid for the S-600 Snow Machine. The machine is tested and calibrated with this liquid to get the best output performance. Warranty will be void if any other type of liquid is used, improper use of liquid may lead to machine failure and malfunction.

Setting Up

| CAUTION!
Risk of injury caused by falling objects.
Make sure installation location, fastening connecting and rigging hardware can hold at least 10 times the weight of the machine.
Make sure that the machine is installed securely and cannot fall down.
It will cause severe injuries if the machine falling down.
---|---

Step 1. Place the machine on a flat surface and in a suitably large area with at least 50 cm open space around the machine.
Step 2. Connect the 5M fluid tube to S-600 and put the filter into the tank. Please do not bend the fluid tube and fill the fluid tank with Antari snow fluid.

Step 3. Connect the machine to a suitably rated power supply. To determine the power requirement for the machine, refer to the label on the back of the machine.
Step 4. Turn on the machine, press the [VOLUME]/[DOWN] button on the control panel to start making snow. To stop making snow, press the [STOP] /[■] button
Step 5. To turn off the machine, press the [STOP] /[■] button and put the power switch to the OFF position.

※ Notice:
The motor of S-600 continues running for about 5 seconds after [STOP] /[■] button is pressed. Please turn off the main power after motor stops running.

Operation

S-600 Yeti snow machine can be operated in the following modes. The machine can accept 1 kind of signal at 1 time. When using different control modes at the same time, the machine will work according to built-in control priority

  • Manual: operation via control panel
  • Timer: operation via control panel
  • DMX 512
  • SC-4 Wired Remote (Optional)
  • Wireless DMX (Optional)
  • W-2 Wireless Transmitter

Priority: Wireless DMX (Optional) > DMX512 > W-2 Wireless Transmitter > SC-4 Wired Remote (Optional) > Manual

Please see the following pages for instructions on your choice of operation.

Control Panel Operation

The machine can be operated in manual or timer modes with the onboard digital control interface

Button Function
[MENU] Scroll through setting menu
▲[UP]/[TIMER] Increase setting value/Activate Timer function
▼[DOWN]/[VOLUME] Decrease setting value/Activate Volume function
■ [STOP] Deactivate Timer/Volume function

Confirm/Leave Setting Menu

Control Menu
Menu Item Description
DMX DMX512 Add: XXX DMX-512 Address: 1-510 (S-600 occupies 3 control

channels.)
LinkMode Wired| Link Mode:Wired / Wireless
W-DMX Unlink?| W-DMX Linking:Linking cancelled
Manual| Interval XXX min| Set interval time at timer mode from 5 to 240 minutes
Duration XXX min| Set duration time at timer mode from 5 to 240 minutes
Volume Out XXX%| Set output volume at volume mode from 0 to 100%
Blower XXX%| Set blower output from 0 to 100% to adjust snowflake size. The smaller output, the bigger snowflake.
Fan Speed XXX%| Set fan speed from 0 to 100%
Info| W-DMX —| W-DMX ok| W-DMX Transmitter assigned, DMX signal received.
No DMX| W-DMX transmitter assigned, No DMX signal
TX Lost| W-DMX link lost or linking to transmitter
Unassign| W-DMX Transmitter not assigned
| UID 1ED8 06020001| Product UID Code
Run Time 0000000H| Accumulated Snowing time:0 – 9999999 hour
Setting| W.Remote Pair| Wireless Transmitter:Pair / Unpair
Run Last Set    Off| Run the last setting:On / Off
KeySound Set    On| Keypad Sound:On / Off
Backlite AlwaysOn| Screen Backlite: On /Off / AlwaysOn
Default Proceed?| Reset to factory settings

Machine Status Message

Screen Description
S-600 v1.0 Software Version
AC Input AC-XXX Input Voltage
Ready To Snow Machine is ready to make snow.
Remote Out XXX% SC-4 wired remote operating (only shows when SC-4 is

connected)
Volume Out XXX%| Running at volume mode
Interval XXX min| Running at timer mode, Interval time
Duration XXX min| Running at timer mode, Duration time
DMX-512 Add: XXX| Current DMX 512 channel
Priming 100%| Activate pump at maximum output
Wrong Voltage!| Wrong input voltage

DMX Connection

DMX Connector Pin Assignment

The machine provides a 5-pin XLR connector for DMX connection. The diagram below indicates pin assignment information.

| Pin| Function
---|---|---
1| Ground
2| Data-
3| Data+
4| N/A
5| N/A

DMX Channel Function
Channel Mode DMX Value Function
Channel 1 Snow Output Volume 0-5 Snow off
6-255 Snow Output 0-100%
Channel 2 Blower Output 0-5 Blower off
6-255 Blower Output 0-100%
Channel 3 Fan Output 0-5 Fan Off
6-255 Fan Output 0-100%

RDM

The S-600 snow machine Yeti is RDM enabled, allowing control system to configure, monitor and manage. See below table for supported RDM parameters.

GET Allowed| SET Allowed| Category| RDM Parameter ID’s (Slot 21-22)| Value| Required
---|---|---|---|---|---
| | | | |
| | Network Management| DISC_UNIQUE_BRANCH| 0x0001| O
| | DISC_MUTE| 0x0002| O
| | DISC_UN_MUTE| 0x0003| O
| | | | |
O| | RDM Information| QUEUED_MESSAGE| 0x0020|
O| | SUPPORTED_PARAMETERS| 0x0050| O
O| | PARAMETER_DESCRIPTION| 0x0051| O
| | | | |
O| | Product Information| DEVICE_INFO| 0x0060| O
O| | PRODUCT_DETAIL_ID_LIST| 0x0070|
O| | DEVICE_MODEL_DESCRIPTION| 0x0080|
O| | MANUFACTURER_LABEL| 0x0081|
O| O| DEVICE_LABEL| 0x0082|
O| | SOFTWARE_VERSION_LABEL| 0x00C0| O
| | | | |
O| O| DMX512 Setup| DMX_PERSONALITY| 0x00E0|
O| | DMX_PERSONALITY_DESCRIPTION| 0x00E1|
O| O| DMX_START_ADDRESS| 0x00F0| O
O| | SLOT_INFO| (0x0120)|
O| | SLOT_DESCRIPTION| (0x0121)|
O| | DEFAULT_SLOT_VALUE| (0x0122)|
| | | | |
O| | Sensors| SENSOR_DEFINITION| 0x0200|
O| O| SENSOR_VALUE| 0x0201|
| | | | |
O| | | DEVICE_HOURS| 0x0400| O
O| O| Control| IDENTIFY_DEVICE| 0x1000| O

Wireless Control Operation

S-600 is equipped with W-2 wireless control function as a standard. Receiver attached onto S-600 before shipped from factory.

W-2 Wireless Transmitter

  • Battery:27A 12V
  • Effective distance:In a free open space, the effective distance is about 50 meters, actual usage depends on obstacle level; the effective distance varies.
  • W-2 Wireless remote control system equipped with 4 buttons to activate, deactivate, adjust snow, motor and fan output level.
Button Function
[A] Press Once:activate output

Keep pressing for 2 seconds:turn off S-600
[B]| Adjust snow output level
Range: 0/20/40/60/80/100%
[C]| Adjust motor output level
Range: 0/20/40/60/80/100%
[D]| Adjust fan output level
Range: 0/20/40/60/80/100%

W-2 Wireless Receiver

S-600 is equipped with W-2 wireless control function as a standard. Transmitter is included in package.
Receiver attached onto S-600 before shipped from factory.

Registering a Transmitter
  • Transmitter can be paired or deleted from the receiver.
  • Each receiver can pair up to 5 transmitters.
  • Follow below steps to pair or delete transmitter.

Step 1. Press [MENU] button and select [Setting]. Screw the menu until [W.Remote] shows on display.

UP: Pair
DOWN:Unpair

Step 2A. Press [UP / ▲] button to select [Pair] to pair a new transmitter. Press [STOP / ■] button, and press any button on the W-2 transmitter to finish pairing.
Step 2B. Press [DOWN / ▼] button to select [Unpair] to delete an existing transmitter.

Wireless DMX Operation (Optional)

WTR-90 (Optional)

WTR-90 includes a 2 in 1 (W-DMX & W-2) receiver and a W-DMX-PCB.

Installation Steps

Step 1. Release unscrew the receiver, and replace it by the 2 in 1 receiver (W-DMXW2R). Connect it to the cable shown as below photo and then screw it the panel.

Step 2. Connect the receiver’s cable with W-DMX-PCB and then install the W-DMX-PCB onto the main PCB circled in red below

※ Please make sure the W-DMX-PCB pins are firmly installed attached with S-600 main PCB.

SC-4 Wired Remote Operation (Optional)

Wired remote control SC-4 enables to control the machine from a remote location. With three push buttons and 3 rotary knobs to activate/deactivate, priming and snow, motor and fan output level adjustment.

Button/Knob Function
[SNOW VOLUME] Knob Adjust snow output level 0-100%
[BLOWER SPEED] Knob Adjust motor output level 0-100% to adjust snowflake

size.
[FAN SPEED] Knob| Adjust fan output level 0-100%
[TIMER] Button| Activate Timer Setting
Interval and duration time is set on control panel. Output level is controlled by rotary knob on SC-4.
[POWER] Button| Turn On/Off SC-4 remote
[MANUAL] Button| Max snow, motor and fan output level.

※IMPORTANT NOTE:

  1. Press [POWER] button to activate SC-4 remote.
  2. With first time operation, a new tank of fluid or refill the fluid may not pump properly due to airlock in the pipeline, use [MANUAL] button to activate pump, motor and fan at maximum output to push the air out of the pipeline.

S-600-BH / 5-liter bottle holder (Optional)

Optional S-600-BH / 5-liter bottle holder is available to meet the needs of different occasions. Follow below steps to install the bottle holder.

Step 1. Release the T shaped handle on S-600.
Step 2. Install S-600-BH to the machine.
Step 3. Screw the T shaped handle back to S-600 tightly to complete the installation.

Service and Maintenance

| DANGER!
Disconnect from mains before starting maintenance operation!
---|---

  • Do not allow the machine to become contaminated.
  • Remove dust from air vents with air compressor, vacuum or a soft brush.
  • Only use a damp cloth to clean the casing.
  • It is recommended to run the machine on a monthly basis in order to achieve best performance and output condition.
  • Excessive dust, liquid and dirt built up will degrade performance and cause overheating.
  • Before storing away after operation, pump pure water through the system for at least 1 to 2 minutes.
    This will help clean out the remaining snow fluid and prevent pump from malfunction on next usage.

Technical Specifications

S-600


Input voltage| US model : AC 100-120V, 50/60Hz 10A
EU model : AC 220-240V, 50/60Hz 5A
Rated power| 1200W
Fluid consumption| 400 ml/min
Compatible fluid| Antari SL-N Snow Foam Fluid
Antari SL-AN Premium Snow Foam Fluid
Antari SL-H Super Dry Snow Foam Fluid
Antari SL-C Anti-Freezing Snow Foam Fluid
Antari SL-UV UV Snow Foam Fluid
Ambient temp/ range| 5°C – 40°C (41°F – 104°F)
Control| Manual, Timer,DMX 512, Wireless
Wireless DMX (Optional)
DMX channels| 3 channels
Connection| Neutrik Powercon (Power)
XLR 5-pin (DMX)


Included accessories

| W-2 Wireless Radio Transmitter
5-Meter Fluid Tube with Filter Hanging Bracket


Optional accessories

| WTR-90 Wireless DMX SC-4 Cable Remote
S-600-BH Bottle Holder (For 5-Liter Bottle. Bottle is not included)
Dimension| L 461.2 W 596 H 629.6 mm
(L 18.16 W 23.47 H 24.79 inch)
Weight| 24 kg (52.9 lbs)

Machine Dimension

Exploded diagram

AC-120V

SPARE PARTS OF S-600

1| S-600-M| Air blower| 11| S-600-PCBC| Control P.C board
2| C040039B0| Rocker switch / Power| 12| S-600-PCB| Main P.C board
3| C04312621| Power socket (Inlet)| 13| C01007010| Socket head cap screw
4| S-600-PCBD5| P.C board DMX 5Pin| 14| C02025000| Handle
5| W-2RA| Wireless Receiver| 15| S-600-PC| Power cord & Plug
6| C045E2900| Control inlet socket| 16| W-2A| Wireless transmitter
7| C00013610| Fluid tube connector| 17| FT-P-6-4A-5M| Fluid tube with filter / 5M
8| S-600-P| Pump (Group)| 18| SC-4| Wired remote controller (Optional)
9| S60000100| Steel| 19| S-600-BH| Bottle holder (Optional)
10| C02000700| Acrylic| | |

AC-230V

SPARE PARTS OF S-600

1| S-600E-M| Air blower| 11| S-600-PCBC| Control P.C board
2| C040039A0| Rocker switch / Power| 12| S-600-PCB| Main P.C board
3| C04312621| Power socket (Inlet)| 13| C01007010| Socket head cap screw
4| S-600-PCBD5| P.C board DMX 5Pin| 14| C02025000| Handle
5| W-2RE| Wireless Receiver| 15| S-600-PC| Power cord & Plug
6| C045E2900| Control inlet socket| 16| W-2E| Wireless transmitter
7| C00013610| Fluid tube connector| 17| FT-P-6-4A-5M| Fluid tube with filter / 5M
8| S-600-P| Pump (Group)| 18| SC-4| Wired remote controller (Optional)
9| S60000100| Steel| 19| S-600-BH| Bottle holder (Optional)
10| C02000700| Acrylic| | |

© 2021 Antari Lighting and Effects Ltd.
www.antari.com