MYSON Unisenza Plus Electronic Thermostatic Head User Manual
- June 13, 2024
- MYSON
Table of Contents
Unisenza Plus Electronic Thermostatic Head
Product Information
Product Name | Unisenza Plus – Electronic Thermostatic Head |
---|---|
Features | Smart, app connectivity |
Battery powered
Geo location
Guarantee| 5 years
Product Usage Instructions
-
Ensure that all personnel involved in the installation,
maintenance, and use of the equipment read the user manual. -
If any points in the manual are unclear or difficult to
understand, contact the Manufacturer for assistance. -
Inspect the product thoroughly before installation or use.
Contact the Manufacturer if any differences are identified. -
Read the manual carefully before installation, use, and
maintenance of the product. Keep it for future reference. -
All installation, assembly, electrical connections to the
mains, and ordinary/extraordinary maintenance must be performed
only by qualified personnel or technicians complying with the legal
requirements. -
The Unisenza Plus Electronic Thermostatic Head is intended for
use as an electronic thermostatic radiator valve (TRV) controller
with wireless communication function in a hydronic heating
system. -
This product is designed to replace an existing passive head on
the standard TRV. -
It utilizes ZigBee 3.0 wireless technology for easy integration
with a smart heating solution for individual radiator
controls.
Installation and user manual
Unisenza Plus – Electronic Thermostatic Head
EN
Smart, app connectivity
Battery powered
Geo location
5 year guarantee
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
Release First release
2
Date August 2023
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
Index
EN
1 Safety warnings ………………………………………………………………………………………………………4 Pictograms used in
this manual………………………………………………………………………………….4 Purpose of the
manual…………………………………………………………………………………………………4 Intended
use…………………………………………………………………………………………………………………..4 Safety
regulations…………………………………………………………………………………………………………5
2 Technical data ………………………………………………………………………………………………………….6 Unisenza Plus
Electronic Thermostatic Head………………………………………………………….6
3 Dimensions……………………………………………………………………………………………………………… 7 4 Pack
contents………………………………………………………………………………………………………….. 7 5 Overview
………………………………………………………………………………………………………………….8
Unisenza Plus Electronic Thermostatic Head………………………………………………………….8 Display
icons………………………………………………………………………………………………………………….8 Button
usage………………………………………………………………………………………………………………….9 6 Download the APP
………………………………………………………………………………………………… 10 7 Nameplate
…………………………………………………………………………………………………………….. 10 8 Installation
…………………………………………………………………………………………………………….. 11 Recommendations for a correct
installation ………………………………………………………….. 11 Heating system
compatibility……………………………………………………………………………………. 11 Inserting the batteries
……………………………………………………………………………………………….. 12 Installation on standard
valve………………………………………………………………………………….. 13 Installation on Danfoss RA valve
…………………………………………………………………………….. 14 9 Use
……………………………………………………………………………………………………………………….. 15 Main screen
operation……………………………………………………………………………………………….. 15 Power
up………………………………………………………………………………………………………………………. 15 Joining to Unisenza Plus
Gateway………………………………………………………………………….. 16 Valve calibration
…………………………………………………………………………………………………………. 18 Pairing with other Unisenza Plus
device (optional) ……………………………………………… 19 Change operation
mode…………………………………………………………………………………………….. 21 Change set point in Manual mode
………………………………………………………………………….. 22 Temporarily change set point in Schedule
mode ………………………………………………… 22 Off mode with frost protection
………………………………………………………………………………… 23 Window open mode
………………………………………………………………………………………………….. 23 Valve protection
…………………………………………………………………………………………………………. 23 Alert / Error
code……………………………………………………………………………………………………….. 23 10
Maintenance…………………………………………………………………………………………………………. 24 Low
battery…………………………………………………………………………………………………………………. 24 Over-the-air (OTA)
software update operation …………………………………………………….. 24 Factory reset
………………………………………………………………………………………………………………. 24 Cleaning
………………………………………………………………………………………………………………………. 25 11 Manual download and
updates ……………………………………………………………………………. 26 12 Disposal at the end of life
…………………………………………………………………………………….. 26
3
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
1 SAFETY WARNINGS
Pictograms used in this manual To make reading clearer and more enjoyable, three types of symbols have been used in this manual to convey to the reader the meaning or importance of the information provided:
Hazard signs. Triangular framed shape. Indicate prescriptions relating to
present or possible dangers.
Prohibition signs. Circular, barred frame. Indicate prescriptions relating to
actions that must be avoided.
Mandatory signs. Full circle. Indicate information that is important to read
and comply with.
Purpose of the manual The purpose of this manual is to guide the qualified
installer the installation, maintenance and proper and safe use of the
equipment.
For this reason, it is mandatory for all personnel involved in the
installation, maintenance and use of the equipment to read this manual.
Contact the Manufacturer if any points are unclear or difficult to understand.
This manual contains information regarding: · Technical specifications of the
equipment; · Installation and connection instructions.
Intended use The Unisenza Plus Electronic Thermostatic Head is an electronic
thermostatic radiator valve (TRV) controller with wireless communication
function for the replacement of an existing passive head on the standard TRV
in a hydronic heating system. It has the latest ZigBee 3.0 wireless technology
for easy integration with a smart heating solution for individual radiator
controls.
Its features are: · Built-in dual thermal sensors for accurate temperature
control · LCD display with backlight · With button for quick set point
adjustment · Support schedule program
4
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
· Modulating control algorithm optimizes the energy efficiency and comfort · Open window detection function for energy savings
EN
· Support standard M30 x 1.5 mm valve connection with optional adaptor to support RA
valve types
· 2xAA batteries operated
Safety regulations Before proceeding with any installation or use, it is necessary to thoroughly inspect the product. Make sure that all the information contained in this manual correspond exactly to the purchased equipment. In the event that differences are identified, it is necessary to contact the Manufacturer in order to obtain the assistance and specific technical information necessary to operate.
Read this manual carefully before the installation, use and maintenance of the
product and keep it for any further future consultation by the various
operators.
All installation, assembly, electrical connections to the mains and ordinary/
extraordinary maintenance must be performed only by qualified personnel or
technicians complying with the legal requirements.
Installation, use or maintenance other than those specified in the manual may
cause damage, injury or death, invalidate the warranty and relieve the
Manufacturer of all liability.
Disconnect the equipment from the mains before installing or maintaining it.
Do not install the equipment outdoors. The product has been designed to be
installed indoors, protected from bad weather, in places where the temperature
is between 0 and +50 °C.
At the end of the installation it is necessary to instruct the user in the
correct use of the equipment.
5
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
2 TECHNICAL DATA
Unisenza Plus Electronic Thermostatic Head
Temperature Scale Temperature display range Temperature display resolution Temperature setting range Temperature setting resolution Temperature measurement accuracy Valve connection Stroke travel Firmware update Wireless Communication Power Supply Operating environment Operating temperature Storage temperature Operating/Storage humidity Dimensions Ingress protection rating Regulation Environmental requirement
°C or °F 0°C – 40°C (32°F – 104°F) 0.5°C (1°F) 5°C – 35°C (41°F – 95°F) 0.5°C (1°F) +/-1°C @ 15-25°C, +/-1.5°C other range M30 x 1.5 mm or M28 x 1.5 mm versions available 4.0 mm Over the air firmware update capability ZigBee 3.0, 2.4GHz 2 x AA-sized Alkaline Batteries Indoor, residential & commercial 0°C 50°C -10°C 60°C 10-95% RH, non-condensing 58(W) x 58(D) x 96(H) mm IP20 CE, UKCA RoHS compliance
The Unisenza Plus Electronic Thermostatic Head complies with the following
European directives:
· RED directive 2014/53/EU · ROHS directive 2011/65/EU · REACH (EC 1907/2006)
The Unisenza Plus Electronic Thermostatic Head complies with the relevant UK
Statutory Instruments: · Electrical Equipment (Safety) Regulations 2016 ·
Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment
Regulations 2012 (SI 2012/3032) · REACH ETC. (Amendment etc.) Regulations 2020
– SVHC
6
3 DIMENSIONS Ø 58
95
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
4 PACK CONTENTS
a
b
c
AA AA
a. Unisenza Plus Electronic Thermostatic Head b. 2 x AA-sized Alkaline Batteries c. RA Adapter
7
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
5 OVERVIEW
Unisenza Plus Electronic Thermostatic Head
1 2 3 4
5
6
1. Display LCD
Button
Button
Button
5. Battery compartment
6. Securing ring
Display icons
Icon
Meaning
Antenna
Pairing status
Heating On Schedule mode
Description
On: the device is joined to a Unisenza Plus network Flashing: the device is
searching for a Unisenza Plus network
On: the device pairs with a room thermostat or a receiver Flashing: the device
is in a pairing process
On: the device demands for Heat and the valve is opened by the Electronic
Thermostatic Head actuator Flashing: the actuator motor is moving to adjust
the valve opening
Schedule mode is running
Off mode Battery icon Digits
Device is in Off mode, frost protection will be running. Shows the battery level Showing set point * or other information
Key lock
Key is locked
Alert
It is shown with an error code tell what system fault
° C ° F
Temperature unit
Temperature unit in Celsius or Fahrenheit
(*) Display of room temperature option can be provided in the advanced settings on the App.
8
Button usage
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
When LCD backlight is Off Turn on the LCD backlight
Press any buttons
When LCD backlight is On
Change mode (Off -> Manual > Schedule)
Increase set point
Decrease set point
Fast increase set point
Fast decrease set point
Key lock or unlock
Confirm set point Join network (if no network is joined before) Initiate
pairing menu (if already joined a network) Factory reset
Press
Press
Press
Press and hold
Press and hold
Press and hold
and
Press , or wait for 3 seconds timout after a new set point is set
Press and hold
Press and hold
Press and hold
more than 10 seconds
No buttons can be used when the Extremely low battery icon appears.
9
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
6 DOWNLOAD THE APP
The management of the Unisenza Plus Electronic Thermostatic Head is also
possible through a dedicated APP that allows its configuration and the
management of the devices you will pair.
In order to download the APP, you need to connect to the STORE of your device
used for configuration and install the Unisenza Plus.
Or, again using the device, you can directly access the installation page
using the following QR codes, again depending on the operating system.
7 NAMEPLATE
A
Inside the battery housing of the Unisenza Plus Electronic Thermostatic Head
there is a sticker (A) which indicates the device data.
QR code availability for future feature.
10
AA AA AA
+ +
8 INSTALLATION
Recommendations for a correct installation
50°C 0°C
+ +
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
Heating system compatibility
The Unisenza Plus Electronic Thermostatic Head is compatible with the majority
of thermostatic radiator valves.
When mounting the Unisenza Plus Electronic Thermostatic Head on the Danfoss RA valve, please use the RA adapter as shown in below picture.
11
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
Inserting the batteries
The Unisenza Plus Electronic Thermostatic Head, to work, requires 2 AA alkaline batteries (included in the package).
Use only and exclusively the batteries indicated by the manufacturer in the table in the “Technical data” chapter.
When installing the batteries, observe the correct polarity indicated in the battery housing. Reversing the polarity runs the risk of damaging the electronic regulator.
To insert the batteries proceed as shown.
2 1
+ +
LR6/AA
AA AA
+ +
AA AA
AA/LR6
3
A1,l5kaVloinlte
4
5
+ +
LR6/AA
AA/LR6
NEW!
1,5VOLT ALKALINE
12
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
Installation on standard valve
EN
To mount the Unisenza Plus Electronic Thermostatic Head on a standard valve proceed as shown.
1
2
During assembly, be very careful not to use too much force in tightening the
various components.
During assembly, if any problems arise, contact the Manufacturer and request
assistance.
13
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
Installation on Danfoss RA valve
To mount the Unisenza Plus Electronic Thermostatic Head on a Danfoss RA valve proceed as shown.
2 1
4 3
During assembly, be very careful not to use too much force in tightening the
various components. During assembly, if any problems arise, contact the
Manufacturer and request assistance.
14
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
9 USE
EN
Main screen operation
The LCD backlight is Off during stand by in normal operation. Press any key to turn on the LCD backlight before performing other user operations as descried below. The LCD backlight will be turned off automatically when no key press for 15 seconds.
When at extremely low battery,
is displayed and flashes. All buttons input is not allowed and the
LCD backlight will not turn On. Therefore, below operations cannot be done.
Power up
The ignition of the Unisenza Plus Electronic Thermostatic Head takes place by
inserting the batteries in their housing, which has already been seen in the
previous chapters. Below what appears on the display.
1 Display power up
° C ° F
2 Firmware version installed
° C
° C
° C
° F
° F
° F
3 Preparation for installation
° C ° F
° C
° F
The device is ready for
installation.
15
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
Joining to Unisenza Plus Gateway
With APP
The association between the Unisenza Plus Electronic Thermostatic Head and the Unisenza Plus Gateway can be done through the system management APP.
To proceed with the association you need to have already installed and configured the Gateway.
1
2
Unisenza Plus Gateway
Instruction Manual
4
Cloud WiFi ZigBee
° C
° C
° F
° F
° ° CF
° ° CF
3
3 SEC
Cloud WiFi ZigBee
° C ° F
If you want to associate a Unisenza Plus Electronic Thermostatic Head that was previously associated with another Gateway, it is necessary to perform a reset to the factory settings of the electronic regulator before making the new association.
16
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
Without APP
EN
The association between the Unisenza Plus Electronic Thermostatic Head and the Unisenza Plus Gateway can also be made directly between the two devices.
To proceed with the association you need to have already installed and configured the Gateway.
1
Unisenza Plus Gateway
Instruction Manual
UP
2
3 SEC
Cloud WiFi ZigBee
3
Cloud WiFi
ZigBee
Cloud WiFi ZigBee
5
Cloud WiFi ZigBee
° C
° C
° F
° F
° ° CF
° ° CF
4
3 SEC
Cloud WiFi ZigBee
° C ° F
If you want to associate a Unisenza Plus Electronic Thermostatic Head that was previously associated with another Gateway, it is necessary to perform a reset to the factory settings of the electronic regulator before making the new association.
17
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
Valve calibration
When the Unisenza Plus Electronic Thermostatic Head is firstly installed to the radiator valve, follow below step to perform the valve adaptation.
To carry out the procedure, proceed as indicated in the following images.
Start calibration
° C
° C
° F
° F
x1
Set point set
° C
° C
° F
° F
° C
° F
Temperature set
° C ° F
During the calibration operation you will hear the sound of the actuator motor moving the valve.
If an error occurs during the adaptation process, the LCD display will show the error code A03. To carry out the procedure again, it is necessary to perform a Power Reset by removing and reinstalling the batteries.
18
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
Pairing with other Unisenza Plus device (optional)
EN
After the Unisenza Plus Electronic Thermostatic Head joined a ZigBee network, it can be paired with a Unisenza Plus Receiver or Unisenza Plus Thermostat.
MENU
BOOST
– MAIN AUTO ON OFF
– AUX –
When pair with a receiver, the Unisenza Plus Electronic Thermostatic Head heat demand will be passed to the receiver to interlock the boiler or the zone valve.
When pair with a room thermostat, the thermostat will become a remote control to the Unisenza Plus Electronic Thermostatic Head. The room temperature measured by the thermostat will be used by the Unisenza Plus Electronic Thermostatic Head.
The Unisenza Plus Electronic Thermostatic Head displays will follow the settings on the room thermostat.
, and the set point and mode control
A maximum of 6 Unisenza Plus Electronic Thermostatic Head can be paired with a room thermostat.
When the Unisenza Plus Electronic Thermostatic Head is paired with a room thermostat, the boiler interlock with the Unisenza Plus Receiver for the heat demand can be done via the thermostat.
A maximum of total 16 Unisenza Plus Electronic Thermostatic Head or Unisenza Plus Thermostat can be paired with Unisenza Plus Receiver.
Pair and unpair device using App
1
Cloud WiFi ZigBee
2
3
19
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
4
5
6
Pair device using the Unisenza Plus Electronic Thermostatic Head local interface
1
2
3
° C
° C
° C
° F
° F
° F
3 SEC
4
5
° C ° F
PAIRING MINUTES
MENU
BOOST
– MAIN AUTO ON OFF
– AUX –
6
Unisenza Plus Receiver
Instruction Manual
OR
Unisenza Plus Thermostat
Instruction Manual
° C ° F
MENU
BOOST
– MAIN AUTO ON OFF
– AUX –
20
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
Unpair device using the Unisenza Plus Electronic Thermostatic Head local interface
EN
1
2
3
° C
° C
° F
° C
° F
° F
3 SEC
MENU
BOOST
– MAIN AUTO ON OFF
– AUX –
x3
4
5
6
° C ° F
° C ° F
° C ° F
MENU
BOOST
– MAIN AUTO ON OFF
– AUX –
Change operation mode
The Unisenza Plus Electronic Thermostatic Head has three operating modes.
Press to change one of the following operation mode. During mode change, the
LCD displays and flashes the mode indication.
Icon
Mode
Schedule mode
Off mode
Manual mode
Explanation
The device operates according to the schedule defined in the App.
The device is turned Off with frost protection active.
The device operates according to the manual input of set point
After selected the operation mode, press or wait for 3 seconds timeout to confirm new mode is changed. The Unisenza Plus Electronic Thermostatic Head display then returns to normal.
21
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
Change set point in Manual mode
1
2
° C ° F
° C ° F
3
° C ° F
4
° C ° F
Temporarily change set point in Schedule mode
1
° C ° F
2
° C ° F
3
° C ° F
This new set point replaces the planning set point temperature and will remain active until the next planning time slot arrives. Subsequently the temperature will be the one established according to the planning on the APP.
The
icon is displayed continuously when temporarily change to set point.
22
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
Off mode with frost protection
EN
When change to Off mode, the icon is displayed and the frost protection is active. The Unisenza Plus Electronic Thermostatic Head actuator will open and close the valve occasionally when the room temperature drops below 5° C in order to avoid the pipe from freezing.
Window open mode
The Unisenza Plus Electronic Thermostatic Head can detect a sudden drop of
room temperature, which is possibly caused by the opening of windows nearby.
In this situation, the heating system may not be able to maintain the room
temperature and thus it should be turned Off to save energy. When the Unisenza
Plus Electronic Thermostatic Head operates (except for in Off mode) and it
detects a sudden drop of temperature, the device enters Window Open mode. In
this mode, the LCD display shows and the actuator will move to close the
valve. This mode ends when the room temperature increases or this mode runs
for 30 minutes.
This mode can also be ended manually by pressing to change back to normal
operation.
Valve protection
If the valve is not opened or closed for a long time may cause scale deposits
that may block the valve from moving. The Unisenza Plus Electronic
Thermostatic Head has a protection function to fully open or close the valve
automatically once every 14 days if no valve movement is detected.
Alert / Error code
When there is fault or alert, the LCD displays
icon and the error code (with prefix ” “, eg. )
on the display.
When more than one alert, the error code is shown one by one. This alert screen and the current
operation screen is displayed alternatively.
Error code
Description Lost link with Gateway.
Lost link with any paired device, either the thermostat or the receiver. Adaptation error.
23
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
10 MAINTENANCE
Low battery
When the Unisenza Plus Electronic Thermostatic Head detects low battery,
is displayed. Bat-
tery should be replaced as soon as possible.
When battery is at extremely low level,
is displayed and flashes.
All buttons input is not available and the actuator motor adjusts the valve at fully open position.
Replace with new batteries and go through the calibration process to resume normal operations.
Over-the-air (OTA) software update operation
The Unisenza Plus Electronic Thermostatic Head upgrades its software
automatically when there is a newer version software available from the
server.
A valid connection to the gateway and the Internet is needed to allow the
Unisenza Plus Electronic Thermostatic Head to download the new software image.
All device functionality is maintained during the download and the update
process, until the device restarts to update the new software. During the
update process, the LCD displays the status on the digit with animation. A
full digit ” ” is displayed after finishing the update.
All settings and paired devices information are retained after the update.
Factory reset
The Unisenza Plus Electronic Thermostatic Head can be factory reset, all
settings including valve calibration, joined Unisenza Plus network and paired
Unisenza Plus device information is reset to factory default.
To restore the device to factory settings, carry out the following operations:
1
° C ° F
2
° C ° F
3
Set up Unisenza Plus Electronic Thermostatic Head again.
10 sec
24
Cleaning
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
SAPONE NEUTRO
e 1000 ml
NSAEPUOTRNOE
25
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
11 MANUAL DOWNLOAD AND UPDATES
Due to the requirement for continuous improvement, we constantly update the
user manuals of our systems. We therefore invite you to periodically check
whether the manual in your possession is always the latest written version. To
do this, you can connect to the following internet address:
https://www.purmogroup.com/support
or by scan the QR code displayed below.
12 DISPOSAL AT THE END OF LIFE
Pursuant to art. 13 of Decree-Law No. 49 of 2014 “Implementation of the WEEE
Directive 2012/19/EU on waste electrical and electronic equipment”. The mark
of the crossed-out bin with a bar specifies that the product was placed on the
market after 13 August 2005 and that at the end of its useful life it must not
be collected with other waste but must be disposed of separately. All the
appliances are made of recyclable metal materials (stainless steel, iron,
aluminium, galvanized sheet metal, copper, etc.) in a percentage greater than
90% by weight. Make the equipment unusable for disposal by removing the power
cable and any compartment or cavity closing device (if any). It is necessary
to pay attention to the management of this product at the end of its life by
reducing any negative impacts on the environment and improving the efficiency
of the use of resources, applying the principles of “polluter pays”,
prevention, preparation for reuse, recycling and recovery. Please note that
the illegal or incorrect disposal of the product entails the application of
the penalties provided for by current legislation.
Information on disposal in Italy In Italy WEEE equipment must be delivered to:
collection centres (also called waste separation areas or platforms) the
Dealer where you buy new equipment, who is required to accept it free of
charge (“one on one” collection).
Information on disposal in European Union countries The EU WEEE equipment
directive has been adopted differently by each country, therefore if you want
to dispose of this equipment we suggest you contact the local authorities or
the dealer to ask for the correct method of disposal.
26
Unisenza Plus – Electronic Thermostatic Head Installation and user manual
EN
27
UNISENZA PLUS – Electronic Thermostatic Head manual EN
22006M1810CO1EN00
A PURMO GROUP BRAND Bulevardi 46 P.O. Box 115 FI-00121 Helsinki Finland
www.purmogroup.com
Every care has been taken in the creation of this document. No part of this
document may be reproduced without the express written consent of Purmo Group.
Purmo Group accepts no responsibility for any inaccuracies or consequences
arising from the use or misuse of the information contained herein.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>