MYSON Unisenza Plus Thermostat Instruction Manual

June 13, 2024
MYSON

MYSON Unisenza Plus Thermostat

MYSON-Unisenza-Plus-Thermostat-product

Product Information

  • Product Name: Unisenza Plus – Thermostat
  • Features:
    • Heating, cooling & hot water control
    • Smart, app connectivity
    • Battery powered
    • Geolocation
    • 5-year guarantee
  • Technical Data:
    • Wireless Technology: Zigbee 3.0
    • Control Outputs: Two channels (programmable room temperature control and timer control for domestic hot water on/off)

Product Usage Instructions

  1. Safety Warnings:
    • Read and understand the hazard signs, prohibition signs, and mandatory signs used in the manual.
    • This manual is mandatory reading for all personnel involved in the installation, maintenance, and use of the equipment.
    • Contact the Manufacturer if any points in the manual are unclear or difficult to understand.
  2. Intended Use:
    • The Unisenza Plus Thermostat is a wireless room thermostat with Zigbee 3.0.
    • It offers two channels of control outputs through Zigbee wireless communications.
    • The first channel can be used for programmable room-temperature controls.
    • The second channel is designed for timer control of domestic hot water on/off.
  3. Safety Regulations:
    • Thoroughly inspect the product before installation or use.
    • Ensure that all the information in the manual matches the purchased equipment.
    • Contact the Manufacturer if any differences are identified.
    • Read the manual carefully before installation, use, and maintenance of the product.
    • All installation, assembly, electrical connections, and maintenance should be done by qualified personnel or technicians complying with legal requirements.

Precaution

SAFETY WARNINGS

Pictograms used in this manual
To make reading clearer and more enjoyable, three types of symbols have been used in this manual to convey to the reader the meaning or importance of the information provided:

  • Hazard signs. Triangular framed shape. Indicate prescriptions relating to present or possible dangers
  • Prohibition signs. Circular, barred frame. Indicate prescriptions relating to actions that must be avoided.
  • Mandatory signs. Full circle. Indicate information that is important to read and comply with.

Purpose of the manual
The purpose of this manual is to guide the qualified installer the installation, maintenance and proper and safe use of the equipment.
For this reason, it is mandatory for all personnel involved in the installation, maintenance and use of the equipment to read this manual.

Contact the Manufacturer if any points are unclear or difficult to understand.

This manual contains information regarding:

  • Technical specifications of the equipment;
  • Installation and connection instructions.

Intended use
The Unisenza Plus Thermostat is a wireless room thermostat with Zigbee 3.0. It offers two channels control outputs through the Zigbee wireless communications. The first channel can be used for programmable room temperature controls and the second channel is designed for a timer control of domestic hot water on/off.

Its features are:

  • Large LCD display with backlight
  • Have pairing features with compatible Unisenza Plus Receiver and Unisenza PLUS
  • Electronic Thermostatic Head
  • Support Heating, Cooling and Domestic Hot Water timer control (S-Plan, Y-Plan)
  • modes include Schedule, Manual, Temporary override, Boost, Holiday and Off with frost protection
  • 7-day, 5/2-day or single-day programming options
  • Optimum start/stop control strategies for energy efficiency
  • Selectable TPI or Span control algorithm
  • 2xAA batteries operated (batteries included)
  • Two-time channels for independent control of Heating/Cooling and/or Hot Water
  • Zigbee and App controlled

Safety regulations
Before proceeding with any installation or use, it is necessary to thoroughly inspect the product. Make sure that all the information contained in this manual correspond exactly to the purchased equipment. In the event that differences are identified, it is necessary to contact the Manufacturer in order to obtain the assistance and specific technical information necessary to operate.

Read this manual carefully before the installation, use, and maintenance of the product and keep it for any further future consultation by the various operators.

  • All installation, assembly, electrical connections to the mains, and ordinary/ extraordinary maintenance must be performed only by qualified personnel or technicians complying with the legal requirements.
  • Installation, use or maintenance other than those specified in the manual may cause damage, injury or death, invalidate the warranty and relieve the Manufacturer of all liability.
  • Disconnect the equipment from the mains before installing or maintaining it.
  • Do not install the equipment outdoors. The product has been designed to be installed indoors, protected from bad weather, in places where the temperature is between 0 and +50 °C.
  • At the end of the installation, it is necessary to instruct the user in the correct use of the equipment.

TECHNICAL DATA

Unisenza Plus Thermostat

Temperature Scale °C or °F
Temperature Display Range 0°C – 45°C
Temperature Display Resolution 0.1°C o 0.5°C
Temperature Setting Range 5°C – 37°C
Temperature Setting Resolution 0.5°C
Temperature Measurement Accuracy +/-0.5°C @ 0-40°C, +/-1.0°C other range
Firmware update Over-the-air firmware update capability
Wireless Communication Zigbee 3.0, 2.4GHz
Transmission Power Zigbee: max 10 dBm
Power Supply 2 x AA-sized Alkaline Batteries
Operating Environment Indoor, residential & commercial
Operating Temperature 0°C – 50°C
Storage Temperature -20°C – 60°C
Operating/Storage Humidity 5-95% RH, non-condensing
Dimensions 119(W) x 97(D) x 28(H) mm
Ingress Protection Rating IP30
Regulation CE, UKCA
Environmental Requirement RoHS compliance

The Unisenza Plus Thermostat complies with the following European directives:

  • RED directive 2014/53/EU
  • ROHS directive 2011/65/EU
  • REACH (EC 1907/2006)

The Unisenza Plus Thermostat complies with the relevant UK Statutory Instruments:

  • Electrical Equipment (Safety) Regulations 2016
  • Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment
  • Regulations 2012 (SI 2012/3032)
  • REACH ETC. (Amendment etc.) Regulations 2020 – SVHC

DIMENSIONS

PACK CONTENTS

MYSON-Unisenza-Plus-Thermostat-fig-5

  • Wall mount bracket
  • Unisenza Plus Thermostat
  • 2 x AA-sized Alkaline Batteries
  • Plate fixing screw
  • Fixing wall plug for plate fixing

OVERVIEW

Unisenza Plus Thermostat

  1. Display LCD
  2. Operation mode button
  3. Boost button
  4. Confirm button
  5. Button +
  6. Button –
  7. Menu / Back button
  8. Battery compartment

Button usage

Button Function

Menu / Back button

| In the Main screen: press to go to the menu.

In Menu: press to go back to the main screen or previous menu, and press and hold to go to the main screen without saving the settings at any time.

Button –| Decrease parameter value / Move on the menu in down direction.
Button +| Increase parameters value / Move on the menu in up direction.
Buttons + and –| Long press Up and Down buttons for 4 sec – lock or unlock the thermostat.


Confirm button

| Confirm Value / Go to next menu / Save settings.

In the menu: press and hold for 4 sec to go back to the main screen with save the settings at any time.

Boost button| Activate/Deactivate Boost (For Heating Only) with max. +9 hr Boost.
Operation mode button| Switch between Permanent Hold and Schedule.

Display iconsMYSON-Unisenza-Plus-Thermostat-fig-8

When OpenTherm is detected

APPLICATIONS

Room Thermostat
The Unisenza Plus Thermostat can be used for the following system types through the integration with HVAC equipment or controllers on a wireless Unisenza Plus network with compatible clusters and attributes, such as Unisenza Plus Receiver.

  • Central heating On/Off controls or OpenTherm
  • Dual channels On/Off controls for central heating and domestic hot water timer
  • Heat/Cool On/Off Control

Room control unit for Electronic Thermostatic Head
The device can also be used as the master room control unit when paired with a Unisenza PLUS Electronic Thermostatic Head. In such use case, the Unisenza Plus Thermostat is used as the room temperature sensor and setpoint interface for the paired Unisenza PLUS Electronic Thermostatic Head. A maximum of six Unisenza PLUS Electronic Thermostatic Heads can be paired to one room control unit.

DOWNLOAD THE APP

The management of the Unisenza Plus Thermostat is also possible through a dedicated APP that allows its configuration and the management of the devices you will pair. In order to download the APP, you need to connect to the STORE of your device used for configuration and install the Unisenza Plus. Or, again using the device, you can directly access the installation page using the following QR codes, again depending on the operating system.

NAMEPLATE

  • At the rear of the Unisenza Plus Thermostat there is a sticker (A) which indicates the device data.
  • QR code availability for future feature

INSTALLATION

Recommendations for a correct installationMYSON-Unisenza-Plus-Thermostat-
fig-13

Fixing the bracket to the wall

  • When fastening, be very careful not to use too much force when tightening the supplied screws.
  • During assembly, if any problems arise, contact the Manufacturer and request assistance.

Inserting the batteries

The Unisenza Plus Thermostat, to work, requires 2 AA alkaline batteries (included in the package). When installing the batteries, observe the correct polarity indicated in the battery housing. Reversing the polarity runs the risk of damaging the electronic regulator

To insert the batteries proceed as shown.

Fixing the thermostat to the bracket

  • When fastening, be very careful not to use too much force when tightening the supplied screws.
  • During assembly, if any problems arise, contact the Manufacturer and request assistance.

USE

Main screen operation
The LCD backlight is Off during stand by in normal operation. Press any key to turn on the LCD backlight before performing other user operations as described below. The LCD backlight will be turned off automatically when no key pressed for 15 seconds.

Power up
The ignition of the Unisenza Plus Thermostat takes place by inserting the batteries in their housing, which has already been seen in the previous chapters.

Below what appears on the display.MYSON-Unisenza-Plus-Thermostat-
fig-17

If “YES” was chosen at the “CONNECT” request, remember to activate the association mode in the Unisenza Plus Gateway, to do this consult the Gateway manual. If “NO” has been chosen, it will be possible to pair the device at a later time by accessing the menu: ADMIN SETTING-> CONNECTION-> NETWORK-> JOIN. It is also possible to associate the thermostat from the APP using the “ADD NEW DEVICE” function. If “YES” was chosen at the “PAIR” request, remember to activate the association mode in the device we want to associate, to do this consult the relative manual. If “NO” has been chosen, it will be possible to associate the device at a later time by accessing the menu: ADMIN SETTING-> CONNECT-> ASSOCIATION-> ADD. It is also possible to associate the thermostat from the APP by entering the thermostat settings menu.

Pairing to Unisenza Plus Gateway

With APP

  • The association between the Unisenza Plus Thermostat and the Unisenza Plus Gateway can be done through the system management APP.
  • To proceed with the association you need to have already installed and configured the Gateway.MYSON-Unisenza-Plus-Thermostat-fig-19MYSON-Unisenza-Plus-Thermostat-fig-20

If you want to associate a Unisenza Plus Thermostat that was previously associated with another Gateway, it is necessary to perform a reset to the factory settings of the electronic regulator before making the new association.

Without APP

  • The association between the Unisenza Plus Thermostat and the Unisenza Plus Gateway can also be made directly between the two devices.
  • To proceed with the association you need to have already installed and configured the Gateway.MYSON-Unisenza-Plus-Thermostat-fig-21MYSON-Unisenza-Plus-Thermostat-fig-22

Without APP
The association between the Unisenza Plus Thermostat and the Unisenza Plus Gateway can also be made directly between the two devices. To proceed with the association you need to have already installed and configured the Gateway.

Pairing with other Unisenza Plus devices (optional)

After the Unisenza Plus Thermostat joins a Unisenza Plus network, it can be paired with a Unisenza Plus Receiver or Unisenza Plus Electronic Thermostatic Head.
When pair with a receiver, the Unisenza Plus Thermostat heat demand will be passed to the receiver to interlock the boiler or the zone valve.

When the room thermostat is paired with a Unisenza Plus Electronic Thermostatic Head, the boiler interlock with the Unisenza Plus Receiver for the heat demand can be done via the thermostat. The thermostat will become a remote control to the Unisenza Plus Electronic Thermostatic Head. The room temperature measured by the thermostat will be used by the Unisenza Plus Electronic Thermostatic Head. The Unisenza Plus Electronic Thermostatic Head displays , and the set point and mode control will follow the settings on the room thermostat.

A maximum of six Unisenza Plus Electronic Thermostatic Heads can be paired with a room thermostat. A maximum of total sixteen Unisenza Plus Electronic Thermostatic Heads or Unisenza Plus Thermostats can be paired with Unisenza Plus Receiver.

Pair device using App

Pair device using the local interfaceMYSON-Unisenza-Plus-Thermostat-
fig-26

Changeset point

  • The icon flashes when Optimum Start/Stop is active or Valve Protection operates.

Change operation mode

Press the Operation Mode button to switch between Schedule/Temporary override and Permanent Hold mode.

The temporary scheduling mode overrides the scheduling set point temperature and will remain active until the next scheduling time slot arrives. Subsequently, the temperature will be the one established according to the planning on the APP.

Boost – Setpoint

  • This mode allows you to temporarily change the set point of a schedule for a certain period of time.
  • To activate the Boost mode, proceed as follows:
  • Once the operating period established for the Boost mode has elapsed, the device will automatically return to operating with the last mode that was previously selected.

Change system mode (Heating &Cooling)MYSON-Unisenza-Plus-Thermostat-
fig-32

Schedule setting

Schedule for different mode (HEATING, COOLING and HOT WATER) can be defined separately here. Three scheduled programs are available (7 DAY / SINGLE / 5+2 DAY).MYSON-Unisenza-Plus-Thermostat-fig-33MYSON-
Unisenza-Plus-Thermostat-fig-34

  • Repeat above procedure to set up to 6th time slot.
  • Press Menu/Back button to return to main screen.

For hot water On/OffMYSON-Unisenza-Plus-Thermostat-
fig-35

  • Repeat the above procedure to set up to 3rd time slot.
  • Press the Menu/Back button to return to the main screen.

Key lock
Lock the keypad

User setting

TIMEDATE

| Time| 12hr or 24hr display format
---|---|---
Clock| Set hour and minute
Date| Set year, month and day
Dst| Daylight saving time on or off
Time disp| Display time on the device or not
Week display| Weekday display by number or by word format
Temp unit|  | Select the temperature display unit in celsius or Fahrenheit
Tr calib|  | Temperature calibration (up to +/- 2.5 °C)

Optimize

|

Start

| Set optimum start On or Off. When Optimum Start is On, the thermostat may turn On HEATING earlier to achieve the set temperature at the time defined in the schedule

Stop

| Set optimum stop On or Off. When Optimum Stop is On, the thermostat may turn Off HEATING earlier to achieve the set temperature at the time defined in the schedule
Frost sp|  | Define Frost Protection set point

Reset

| Reboot| Perform a power cycle reset (all settings are kept unchanged)

User

| Reset user settings, SYS MODE and schedule back to default value. It returns to USER SET- TINGS screen after reset.

Press the Menu/Back button to return to the main screen.

Admin setting

Temp disp|  | Select temperature display interval at 0.5°C(1°F) or 0.1°C (0.2°F).
---|---|---

Vlv prot

|  | Select valve protection mode On or Off. If the relay is not turned On for a week, the thermostat will turn On the heat- ing to move the actuators for less than 3 minutes time, to avoid the valve getting stuck or jamming.

Control

Select which control algorithm mode is used for room temperature control

| TPI ugh| (available when SYS MODE is “HEAT”): algorithm designed for underfloor heating (for heating systems with high inertia).
TPI rad| (available when SYS MODE is “HEAT”): algorithm designed for radiator heating.

TPI elec

| (available when SYS MODE is “HEAT”): an algorithm for electric heating (for heating systems that heat up quickly an cool down quickly).
Span ¼° c (span ½° f)| Permanent deviation of temperature in P Mode.
Span ½° c (span 1° f)| Permanent deviation of temperature in P Mode.

Min sp

| Heat| Set minimum HEATING set point (5°C to 35°C).
Cool| Set minimum COOLING set point (5°C to 35°C).

Max sp

| Heat| Set maximum HEATING set point (5.5°C to 37°C).
Cool| Set maximum COOLING set point (5.5°C to 37°C).

Connect

| Network Join| Join the thermostat to the gateway.
---|---|---
Network Unjoin| Disconnect the thermostat from the gateway.
Network Identify| Identify which gateway is connected.
Pair State| Show the number of paired devices.
Pair Identify| Select the EU-ID (display the last 6 digits) of a Unisenza Plus device to identify.
Pair Add| Pair a Unisenza Plus device to the thermostat.
Pair Remove| Select EU-ID (display the last 6 digit) of a Unisenza Plus device to unpair.

Pin code

for access to the ADMIN SET

menu

| Disable| Disable the PIN code.

Enable

| Enable the PIN code, and then SET a 4-digit PIN code.

In case the PIN code is forgotten, power reset the thermostat. Then within 2 minutes from power on, use the manufacturer PIN code 0682 to access the ADMIN SET menu to set a new PIN code.

DEV info

| Battery| Display battery level in percentage.

RF range

| Display the value of RSSI (Received Signal Strength Indicator) between the thermostat and gateway. If the wireless connection is lost, a lost link message is displayed.
Version| Display the software version of this thermostat

Sys type

| Heat only|

Select one of the system type below.

Heat + Dhw
Heat + Cool

Reset

|

Admin

| Reset settings in the ADMIN SET menu (Joined network and paired Unisenza Plus device information is maintained).

Factory

| Reset everything back to the status same as the thermostat first unboxed. It displays “RESETTING” during the process and then reboots with default settings to finish the factory reset process.

Language setting

Protection
High temperature limiting
If the room temperature exceeds 41°C, all heating outputs will be turned off.
Temperature sensing error
If there is any sensor error on room temperature measurement, the thermostat will notify all related output devices to turn Off.

Error code display
An error code will be displayed on the text bar when error is detected. When single error is detected, the error code is displayed directly on the text bar. When multiple errors are detected, text bar displays XX ERRORS while XX is the total number of error detected. Press the Confirm button to display the first error code, then press “Up” or “Down” to view another error code.

Once the error is solved, the error code disappears accordingly. The error code description is as below.

Error Code Error Description
ERROR 001 Lost link with the Unisenza Plus Gateway
ERROR 003 – 014 Pair Unisenza Plus device fail
ERROR 10X Lost link with the Xth paired Unisenza Plus device
ERROR 201 Lost link with Domestic Hot Water channel of the Unisenza

Plus Receiver
ERROR 301| OT Boiler Fault Code – Service Request
ERROR 302| OT Boiler Fault Code – Lockout-reset
ERROR 303| OT Boiler Fault Code – Low water pressure
ERROR 304| OT Boiler Fault Code – Gas/flame fault
ERROR 305| OT Boiler Fault Code – Air pressure fault
ERROR 305| OT Boiler Fault Code – Exceeding max. water temperature
ERROR 40X| OT OEM Fault Code – Please check with your OT boiler instruction for error code meaning

MAINTENANCE

Low battery

  • When the Unisenza Plus Thermostat detects low battery, is displayed. The battery should be replaced as soon as possible.
  • Replace with new batteries and go through the adaptation process to resume normal operations.

Over-the-air (OTA) software update operation.
The Unisenza Plus Thermostat upgrades its software automatically when there is a newer version of the software available from the server.
A valid connection to the gateway and the Internet is needed to allow the Unisenza Plus Thermostat to download the new software image. All device functionality is maintained during the download and the update process until the device restarts to update the new software. During the update process, the LCD displays the status on the digit with animation. A full digit “ ” is displayed after finishing the update.

All settings and paired device information are retained after the update.

Cleaning

MANUAL DOWNLOAD AND UPDATES

  • Due to the requirement for continuous improvement, we constantly update the user manuals of our systems.
  • We therefore invite you to periodically check whether the manual in your possession is always the latest written version.
  • To do this, you can connect to the following internet address:
  • https://www.purmogroup.com/support or by scan the QR code displayed below.

DISPOSAL AT THE END OF LIFE

Pursuant to art. 13 of Decree-Law No. 49 of 2014 “Implementation of the WEEE Directive 2012/19/EU on waste electrical and electronic equipment”. The mark of the crossed-out bin with a bar specifies that the product was placed on the market after 13 August 2005 and that at the end of its useful life it must not be collected with other waste but must be disposed of separately. All the appliances are made of recyclable metal materials (stainless steel, iron, aluminium, galvanized sheet metal, copper, etc.) in a percentage greater than 90% by weight. Make the equipment unusable for disposal by removing the power cable and any compartment or cavity closing device (if any). It is necessary to pay attention to the management of this product at the end of its life by reducing any negative impacts on the environment and improving the efficiency of the use of resources, applying the principles of “polluter pays”, prevention, preparation for reuse, recycling and recovery. Please note that the illegal or incorrect disposal of the product entails the application of the penalties provided for by current legislation.

Information on disposal in Italy
In Italy WEEE equipment must be delivered to: collection centres (also called waste separation areas or platforms) the Dealer where you buy new equipment, who is required to accept it free of charge (“one on one” collection).

Information on disposal in European Union countries

The EU WEEE equipment directive has been adopted differently by each country, therefore if you want to dispose of this equipment we suggest you contact the local authorities or the dealer to ask for the correct method of disposal.

  • A PURMO GROUP BRAND
  • Bulevardi 46
  • P.O. Box 115
  • FI-00121 Helsinki
  • Finland
  • www.purmogroup.com.

Every care has been taken in the creation of this document. No part of this document may be reproduced without the express written consent of Purmo Group. Purmo Group accepts no responsibility for any inaccuracies or consequences arising from the use or misuse of the information contained herein.