smartwares 887106 Smoke Alarm Device User Manual

June 13, 2024
smartwares

smartwares 887106 Smoke Alarm Device

smartwares 887106 Smoke Alarm Device

GENERAL INFORMATION

Thank you for purchasing this Smartwares smoke alarm device! Please read these instructions carefully before using the smoke alarm device. Retain this information in a safe and easily accessible place for future use and maintenance. If you have any questions or if you are looking for additional information about your smoke alarm device, please visit our website www.smartwares.eu.

  • Make/model number: RM520
  • Description: Smoke alarm device based on the photocell principle, which means that the alarm monitors the air for smoke caused by fire. This apparatus contains a lithium battery with a lifetime of 10 years.
  • Function: Smoke alarm device intended to alert the persons present near a fire/fire smoke, to give them time to react properly to the danger
  • Scope of application: Smoke alarm device for buildings with residential function and leisure accommodating vehicles.

IMPORTANT:

  • Caution: The alarm is designed in order to detect smoke; it cannot prevent a fire!
  • Caution: Using a smoke alarm is part of your fire protection, just as fire extinguishers, emergency ladders, ropes, but also your choice in the use of building materials for renovation. Always ensure that there is an evacuation plan and discuss this with your children. Ensure that each room can be left without opening the door, e.g. by the window. If there is any question as to the cause of an alarm, it should be assumed that the alarm is due to an actual fire and the dwelling evacuated immediately.
  • Warning: Smoke alarm devices must be replaced no later than 10 years after initial activation. Fill out the activation date on the rating label on the product and mark the replacement date in your calendar.

INITIAL ACTIVATION

Before mounting this smoke alarm device, it is important to activate and test the apparatus. The detector will be activated by removing the red activation pin (see image 1). To test the device, press and hold the test button (see image 2) until an alarm signal sounds and the red LED flashes rapidly, then release. At the same time, the smoke alarm device will go into alarm silence/hush mode. After 9 minutes the smoke alarm will automatically reset to normal mode. If the alarm If the alarm signal does not sound after pressing the test button, the smoke alarm device is not working properly and the advice of Smartwares should be sought.

Initial Activation
Initial Activation

MOUNTING

To mount the smoke alarm device, fix the base plate with the screws supplied and gently tighten the alarm onto the base plate (see image 3). Pay close attention to below siting recommendations to guarantee optimal performance of your smoke alarm device. After installing the smoke alarm device, always test its functionality by using the test button (see image 2).

Mounting

Important:

  • WARNING: To prevent injury, this apparatus must be securely attached to the ceiling in accordance with the installation instructions.
  • Smoke alarm devices should be installed in such a way that they can be reached unimpeded by the fire smoke, so that fires can be detected reliably in the development phase.
  • Requirements for smoke alarm devices vary from state to state and from region to region. Always check the relevant requirements in your area with your local authorities!

Where to mount a smoke alarm device?

  • Centered at ceiling of the room
  • Max height: 6m
  • Min 0,5 m distance to walls/ barriers:
  • Small rooms with width <1m: Centered at the ceiling
  • Corridors with max width 3m: max 15m distance between 2 smoke alarm devices. Max. 7.5m to front side and smoke alarm devices at edges/crossings of corridors.
  • Galleries: If length and width of the gallery are >2m and gallery area is >16m2, additional smoke alarm device required below gallery
  • In roof slopes: If >20°, minimal 0,5m and maximal 1m to roof top. If ≤20°, consider as flat ceiling. In partial roof slopes: if flat ceiling ≤1m width, consider as roof slope. If flat ceiling is >1m wide, consider as flat ceiling.
  • Ceiling joists (or similar): If height ≤0,2m, installation at ceiling or on joist. If height > 0,2m and separated area > 36m2 => additional smoke alarm devices in between.

Where not to mount your smoke alarm device?

  • Close to air conditioning/ventilation systems;
  • Locations where the ventilation can be impeded items such curtains etc.;
  • In rooms where temperature can reach below -10°C and above 40°C.
  • In damp spaces/kitchens/bathrooms, because steam can cause false alarms. Please visit our website for alarms that are suitable for usage in these rooms;
  • Closer than 50 cm to light sources/electrical sources;
  • Locations that are difficult to reach and impede the accessibility of the test button, battery replacement and maintenance.

ALARM SILENCE / HUSH MODE

When the smoke alarm device gives an alarm, please verify the cause of the alarm first. If required, the smoke alarm device can be placed into hush mode by pressing the test/hush button. During hush mode the LED will flash every 10 seconds to indicate the smoke alarm device is in hush mode. Please remove the smoke or cause of the alarm and after 9 minutes the smoke alarm will automatically reset to normal mode. If the cause of the alarm is still present the smoke alarm device will give an alarm again. If during hush mode the smoke that caused the alarm increases, the smoke alarm device will also sound the alarm.

Note: Dense smoke will override the hush mode and sound a continuous alarm.
Caution: Before using the alarm silence (hush mode), identify the source of the smoke and make sure the situation is safe.

EMPTY BATTERY SIGNAL / END OF LIFE

When the battery is running low, the smoke alarm will indicate this with a repetitive beep and flash. This indicator sounds continually with intervals of 40 seconds for at least 30 days.

This smoke alarm is equipped with a non-replaceable battery. When this warning occurs, replace the device as soon as possible.
We highly recommend you to replace the smoke alarm on a fixed date, to ensure timely replacement. Please register for free reminders at smartreminder.eu.

The acoustic low battery warning signal can be silenced for 10 hours by pressing the test button. The smoke alarm is still functioning and able to detect smoke when it is in this mode

ALARM MEMORY

When the smoke alarm device has given an alarm, it will go into alarm memory. The green LED will flash 3 times for 43 seconds. If you are not at home, this function will remind the user that the smoke alarm device has given alarm. The green LED will automatically stop flashing after 24 hours or can be stopped manually by pressing the test/hush button.

MAINTENANCE

Testing: We highly recommend you to test the functionality of your smoke alarm device every month to check if the smoke alarm is functioning correctly and to ensure the full lifetime of the battery. Press and hold the test button until the user friendly short alarm signal sounds. The signal stops once the button is released. If the alarm signal does not sound after pressing the test button, the smoke alarm device is not working properly and the advice of Smartwares should be sought.

Warning: Do not use an open flame to test your smoke alarm device, this could damage the apparatus or ignite combustible materials and start a fire.

Cleaning: For optimal performance, the smoke alarm device must be dusted once a month and vacuumed every six months. Do not touch the inside of the smoke alarm device with the nozzle of the vacuum cleaner. Always test the functionality of the apparatus after cleaning by pressing the test button. Please register for free reminders at smartreminder.eu

TROUBLE SHOOTING

  • False alarm may be caused by: welding and cutting operations, soldering and other hot work, sawing and grinding, dust due to construction work or cleaning, water vapor, cooking fumes, extreme electromagnetic effects, temperature fluctuations, which lead to the condensation of the humidity in the smoke alarm.
  • Dust is the most common cause of false alarms/failing alarm, therefore always clean the smoke alarm as described in paragraph ‘maintenance’ if you experience any issues. If this does not solve the problem, the advice of Smartwares should be sought.
  • Smartwares can never be made liable for loss and/or damage of whatever nature, including incidental and/or consequential loss, arising from the fact that the signal from the smoke alarm did not sound during smoke or fire. Smartwares can never be made liable for loss and/or damage of whatever nature, including incidental and/or consequential loss, arising from the fact that the signal from the smoke alarm did not sound during smoke or fire.

TECHNICAL DATA

  • Smoke sensor: Optical
  • Battery type: 3V DC Lithium
  • Battery replaceable: No
  • Battery lifetime: 10 years
  • Lifetime device: 10 years
  • Operating temperature: -10° – + 40 °C
  • Operating humidity: ≤95%RH (no condensation)
  • Alarm volume: >85dB (A) at 3m
  • Mounting type: Ceiling
  • Detection area: Max 40m2
  • Hush function: Yes
  • Installation in camping car: Yes
    For indoor use only.
    Please read manual before use, and store it carefully for future use and maintenance
Condition LED Sound
Normal operation Red LED flashes every 344 seconds None
Testing Red LED flashes rapidly Quick beeps
Alarm Red LED flashes rapidly Quick beeps
Hush mode Red LED flashes every 10 seconds None
Low battery indication Flashes every 40 seconds 1 short beep every 43

seconds
Alarm Memory| Green LED flashes every 43 seconds| None
End of life| None| 3 short beeps every 43 seconds

INTENDED USE: FIRE SAFETY

ESSENTIAL CHARACTERISTICS: PASSED

  • Nominal activation conditions/ Sensitivity, Response delay (response time) and Performance under fire condition
  • Operational reliability
  • Tolerance to supply voltage
  • Durability of operational reliability and response delay, temperature resistance
  • Durability of operational reliability, vibration resistance
  • Durability of operational reliability, humidity resistance
  • Durability of operational reliability, corrosion resistance
  • Durability of operational reliability, electrical stability

Mounting
Fire Safety

CUSTOMERS SUPPORT

2831 RM520-004CPR 19
Fire Safety EN14604:2005/AC:2008

Symbols

smartwares’ Europe
Jules Verneweg 87 5015 BH Tilburg The Netherlands
www.smartwares.eu

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals