TRANE A952V080CU5SAC RunTru Central Air Conditioner And Gas Furnace Split System Owner’s Manual

June 13, 2024
Trane

TRANE A952V080CU5SAC RunTru Central Air Conditioner And Gas Furnace Split

System

TRANE-A952V080CU5SAC-RunTru-Central-Air-Conditioner-And-Gas-Furnace-Split-
System-product

Product Information

  • Product Name: Upflow/Horizontal Left/Right Two-Stage Condensing Gas-Fired Furnace

  • Model: A952V080CU5SAC/D

  • Type: Upflow / Horizontal

  • Ratings:

    • 1st Stage Input BTUH: 52,000
    • 1st Stage Capacity BTUH (ICS): 50,600
    • 2nd Stage Input BTUH: 80,000
    • 2nd Stage Capacity BTUH (ICS): 77,750
    • AFUE (%): 96.0
  • Blower Drive:

    • Diameter – Width (in.): DIRECT 11 X 10
    • No. Used Speeds: 1 Variable
    • CFM vs. in. w.g.: See Fan Performance Table 1
    • Motor HP R.P.M. Volts / Ph / Hz: Variable, 120 / 1 / 60
    • FLA: 10.5 / 10
  • Combustion Fan:

    • Type: PSC
    • Drive – No. Speeds: Direct – 2
    • Motor RPM: 3300/2600
    • Volts/Ph/Hz: 120 / 1 / 60
  • Filter – Furnished?: No

  • Vent Outlet Diameter – Min. (in.): 2 Round

  • Inlet Air Diameter – Min. (in.): 2 Round

  • Gas Valve: Redundant – Two Stage

  • Burners – Type – Qty: Inshot – 4

  • Power Connection: 120 / 1 / 60, Ampacity: 13.9 / 13.3, Max.
    Overcurrent Protection: 15

  • Pipe Connection Size (in.): 1/2

  • Dimensions:

    • Uncrated (in.): HxWxD 34 x 21 x 28-3/4
    • Created (in.): 35-1/2 x 23 x 30-7/8
  • Weight:

    • Shipping (Lbs.)/Net (Lbs.): 149/139

Product Usage Instructions

  1. Ensure the furnace is installed in an up-flow or horizontal position according to your requirements.
  2. Connect the appropriate gas supply to the furnace, using the specified pipe connection size of 1/2 inch.
  3. If using natural gas, install four main orifices with a drill size of 45. If using propane gas, install four main orifices with a drill size of 56.
  4. Make sure the vent outlet diameter is a minimum of 2 inches round.
  5. Connect the inlet air with a minimum diameter of 2 inches round.
  6. Ensure the power connection is made according to the specified voltage, phase, and frequency (120 / 1 / 60).
  7. Provide proper overcurrent protection with a maximum amperage of 15 amps.
  8. Refer to the provided airflow tables for heating and cooling settings.
  9. Make sure to comply with local codes and regulations during installation.

Outline Drawing

TRANE-A952V080CU5SAC-RunTru-Central-Air-Conditioner-And-Gas-Furnace-Split-
System-fig-1

Product Specification

Model| A952V080CU5SAC/D

(a) , (b)

---|---
Type| Upflow / Horizontal
RATINGS (c)|
1st Stage Input BTUH| 52,000
1st Stage Capacity BTUH (ICS)| 50,600
2nd Stage Input BTUH| 80,000
2nd Stage Capacity BTUH (ICS) (d)| 77,750
1st Stage Temp. Rise (Min. – Max.) °F| 30 – 60
2nd Stage Temp. Rise (Min. – Max.) °F| 35 – 65
AFUE (%) (d)| 96.0
Return Air Temp. (Min. – Max.) °F| 45°F – 80°F
BLOWER DRIVE| DIRECT
Diameter – Width (in.)| 11 X 10
No. Used| 1
Speeds (No.)| Variable
CFM vs. in. w.g.| See Fan Performance Table
Motor HP| 1
R.P.M.| Variable
Volts / Ph / Hz| 120 / 1 / 60
FLA| 10.5 / 10
COMBUSTION FAN Type| PSC
Drive – No. Speeds| Direct – 2
Motor RPM| 3300/2600
Volts/Ph/Hz| 120 / 1 / 60
FLA| 0.66
Inducer Orifice| 0.88
FILTER – Furnished?| No
Type Recommended| High Velocity
Hi Vel. (No.-Size-Thk.)| 1 – 20 X 25 – 1 in.
VENT OUTLET DIAMETER MIN.

(in.) (e)

| 2 Round
INLET AIR DIAMETER -MIN.

(in.) (e)

| 2 Round
---|---
HEAT EXCHANGER Type|
Fired| 409 Stainless Steel
Unfired| 29-4C Stainless Steel
Gauge (Fired)| 20
ORIFICES Main|
Nat. Gas (Qty. – Drill Size)| 4 – 45
Propane Gas (Qty. – Drill Size)| 4 – 56
GAS VALVE| Redundant – Two Stage
PILOT SAFETY DEVICE Type| 120 V SiNi Igniter
BURNERS TYPE – QTY| Inshot – 4
POWER CONN. V/Ph/HZ (f)| 120 / 1 / 60
Ampacity (Amps)| 13.9 / 13.3
Max. Overcurrent Protection (Amps)| 15
PIPE CONN. SIZE (IN.)| 1/2
DIMENSIONS| H x W x D
Uncrated (in.)| 34 x 21 x 28-3/4
Created (in.)| 35-1/2 x 23 x 30-7/8
WEIGHT|
Shipping (Lbs.)/Net (Lbs.)| 149/139

  • Meets Energy Star
  • Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 – latest edition.
  • For U.S. Applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above-input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
  • Based on U.S. government standard tests.
  • Refer to the Vent Length Table in the Installer’s Guide.
  • The above wiring specifications are in accordance with the National Electrical Code; however, installations must comply with local codes.

Heating and Cooling Airflow

Table 1. A952V080CU5SAC Heating Airflow

A952V080CU5SAC Furnace Heating Airflow (CFM), Temp. Rise (°F), and Power (Watts) vs. External Static Pressure with

Filter (iwc)


| 1st Stage Capacity = 50,600

2nd Stage Capacity = 77,750

Heating| Airflow

Setting

| Target

Airflow

| | External Static Pressure
0.1| 0.3| 0.5| 0.7| 0.9





Heating 1st Stage

| ****

Low

| ****

857

| CFM| 837| 870| 902| 934| 967
Temp. Rise| 55| 53| 51| 50| 48
Watts| 65| 112| 160| 208| 256


Medium Low (a)

| ****

1044

| CFM| 997| 1015| 1033| 1050| 1068
Temp. Rise| 46| 45| 45| 44| 43
Watts| 102| 155| 209| 263| 316


Medium

| ****

1123

| CFM| 1067| 1094| 1121| 1148| 1175
Temp. Rise| 43| 42| 41| 40| 39
Watts| 123| 180| 236| 293| 350


High

| ****

1498

| CFM| 1420| 1416| 1411| 1407| 1402
Temp. Rise| 32| 33| 33| 33| 34
Watts| 238| 320| 402| 485| 567





Heating 2nd Stage

| ****

Low

| ****

1190

| CFM| 1129| 1148| 1168| 1188| 1208
Temp. Rise| 63| 62| 61| 60| 59
Watts| 127| 195| 263| 331| 399


Medium Low (a)

| ****

1450

| CFM| 1387| 1395| 1404| 1412| 1420
Temp. Rise| 52| 51| 51| 51| 51
Watts| 248| 310| 372| 434| 496


Medium

| ****

1560

| CFM| 1484| 1498| 1512| 1525| 1539
Temp. Rise| 48| 48| 47| 47| 47
Watts| 281| 358| 435| 512| 589


High

| ****

2080

| CFM| 1954| 1956| 1959| 1961| 1964
Temp. Rise| 37| 37| 37| 37| 37
Watts| 597| 732| 866| 1001| 1135

  • (a) Factory Setting.

Table 2. A952V080CU5SAD Heating Airflow

A952V080CU5SAD Furnace Heating Airflow (CFM), Temp. Rise (°F), and Power (Watts) vs. External Static Pressure with

Filter (iwc)


| 1st Stage Capacity = 50,600

2nd Stage Capacity = 77,750

Heating| Airflow

Setting

| Target

Airflow

| | External Static Pressure
0.1| 0.3| 0.5| 0.7| 0.9





Heating 1st Stage

| ****

Low

| ****

857

| CFM| 838| 821| 804| 788| 771
Temp. Rise| 56| 57| 57| 58| 59
Watts| 68| 109| 151| 192| 234


Medium Low (a)

| ****

1044

| CFM| 967| 993| 1019| 1045| 1070
Temp. Rise| 48| 47| 46| 45| 44
Watts| 91| 145| 198| 252| 306


Medium

| ****

1123

| CFM| 1060| 1058| 1056| 1053| 1051
Temp. Rise| 44| 44| 44| 43| 43
Watts| 108| 165| 222| 279| 335


High

| ****

1224

| CFM| 1266| 1171| 1075| 980| 884
Temp. Rise| 36| 40| 43| 46| 50
Watts| 134| 194| 253| 313| 373





Heating 2nd Stage

| ****

Low

| ****

1190

| CFM| 1114| 1127| 1141| 1154| 1167
Temp. Rise| 64| 63| 62| 62| 61
Watts| 127| 188| 250| 312| 373


Medium Low (a)

| ****

1450

| CFM| 1359| 1378| 1396| 1414| 1432
Temp. Rise| 52| 52| 51| 50| 49
Watts| 216| 291| 365| 439| 514


Medium

| ****

1560

| CFM| 1466| 1474| 1482| 1490| 1497
Temp. Rise| 48| 48| 48| 48| 48
Watts| 263| 344| 426| 507| 588


High

| ****

1700

| CFM| 1774| 1731| 1689| 1647| 1605
Temp. Rise| 40| 41| 42| 43| 44
Watts| 356| 437| 518| 600| 681

  • (a) Factory Setting.

Table 3. A952V080CU5SAC/D Cooling Airflow

A952V080CU5SAC/D Furnace Cooling Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter (iwc)


Cooling

| Unit Outdoor| Airflow

Setting (CFM/ton)

| | External Static Pressure
| 0.1| 0.3| 0.5| 0.7| 0.9








Cooling

| ****







3.0 Ton

| Cooling 450

CFM/Ton

| CFM| 1335| 1347| 1356| 1362| 1366
Watts| 182| 241| 303| 366| 431
Cooling 420

CFM/Ton

| CFM| 1246| 1259| 1267| 1273| 1277
Watts| 152| 208| 266| 326| 387
Cooling 400

CFM/Ton

| CFM| 1188| 1200| 1208| 1214| 1217
Watts| 134| 188| 243| 301| 360
Cooling 370

CFM/Ton

| CFM| 1100| 1111| 1118| 1123| 1125
Watts| 110| 160| 212| 266| 322
Cooling 350

CFM/Ton

| CFM| 1041| 1052| 1058| 1061| 1063
Watts| 96| 143| 193| 245| 299
Cooling 330

CFM/Ton

| CFM| 983| 993| 997| 999| 1000
Watts| 83| 128| 176| 225| 277
Cooling 310

CFM/Ton

| CFM| 925| 933| 936| 937| 936
Watts| 72| 114| 159| 207| 257
Cooling 290

CFM/Ton

| CFM| 867| 873| 874| 873| 871
Watts| 61| 101| 144| 190| 239








Cooling

| ****







3.5 Ton

| Cooling 450

CFM/Ton

| CFM| 1557| 1568| 1576| 1581| 1585
Watts| 273| 342| 413| 486| 559
Cooling 420

CFM/Ton

| CFM| 1453| 1465| 1473| 1480| 1483
Watts| 228| 292| 359| 427| 496
Cooling 400

CFM/Ton

| CFM| 1384| 1396| 1405| 1411| 1415
Watts| 200| 262| 325| 391| 457
Cooling 370

CFM/Ton

| CFM| 1281| 1293| 1302| 1308| 1312
Watts| 163| 221| 280| 341| 404
Cooling 350

CFM/Ton

| CFM| 1212| 1224| 1233| 1239| 1242
Watts| 142| 196| 253| 311| 371
Cooling 330

CFM/Ton

| CFM| 1144| 1155| 1163| 1168| 1171
Watts| 122| 173| 227| 283| 341
Cooling 310

CFM/Ton

| CFM| 1076| 1086| 1093| 1097| 1099
Watts| 104| 153| 204| 257| 312
Cooling 290

CFM/Ton

| CFM| 1007| 1017| 1023| 1025| 1026
Watts| 88| 134| 183| 233| 286








Cooling

| ****







4.0 Ton

| Cooling 450

CFM/Ton

| CFM| 1782| 1789| 1794| 1797| 1798
Watts| 392| 471| 551| 632| 715
Cooling 420

CFM/Ton

| CFM| 1662| 1671| 1678| 1682| 1685
Watts| 325| 399| 474| 550| 628
Cooling 400

CFM/Ton

| CFM| 1582| 1592| 1600| 1606| 1609
Watts| 285| 355| 427| 500| 575
Cooling 370

CFM/Ton

| CFM| 1463| 1474| 1483| 1489| 1493
Watts| 232| 297| 364| 432| 502
Cooling 350

CFM/Ton

| CFM| 1384| 1396| 1405| 1411| 1415
Watts| 200| 262| 325| 391| 457
Cooling 330

CFM/Ton

| CFM| 1305| 1317| 1327| 1333| 1337
Watts| 172| 230| 290| 352| 416
Cooling 310

CFM/Ton

| CFM| 1227| 1239| 1248| 1254| 1257
Watts| 146| 201| 258| 317| 378
Cooling 290

CFM/Ton

| CFM| 1149| 1160| 1168| 1173| 1176
Watts| 123| 175| 229| 285| 343








Cooling

| ****







4.5 Ton

| Cooling 450

CFM/Ton

| CFM| 2008| 2011| 2012| 2011| 2008
Watts| 542| 630| 719| 811| 903
Cooling 420

CFM/Ton

| CFM| 1872| 1878| 1881| 1883| 1882
Watts| 448| 530| 614| 700| 786
Cooling 400

CFM/Ton

| CFM| 1782| 1789| 1794| 1797| 1798
Watts| 392| 471| 551| 632| 715
Cooling 370

CFM/Ton

| CFM| 1647| 1656| 1663| 1668| 1670
Watts| 318| 390| 465| 541| 618
Cooling 350

CFM/Ton

| CFM| 1557| 1568| 1576| 1581| 1585
Watts| 273| 342| 413| 486| 559
Cooling 330

CFM/Ton

| CFM| 1468| 1479| 1488| 1494| 1498
Watts| 234| 299| 366| 435| 505
Cooling 310

CFM/Ton

| CFM| 1379| 1391| 1400| 1407| 1410
Watts| 198| 260| 323| 388| 455
Cooling 290

CFM/Ton

| CFM| 1291| 1303| 1312| 1318| 1322
Watts| 167| 224| 284| 346| 409








Cooling

| ****







5.0 Ton (a)

| Cooling 450

CFM/Ton

| CFM| 2235| 2233| 2230| 2224| 2216
---|---|---|---|---|---|---|---|---
Watts| 726| 824| 923| 1023| 1125
Cooling 420

CFM/Ton

| CFM| 2084| 2085| 2084| 2082| 2078
Watts| 599| 690| 783| 877| 973
Cooling 400

CFM/Ton

| CFM| 1983| 1986| 1988| 1988| 1985
Watts| 524| 611| 699| 789| 880
Cooling 370

CFM/Ton

| CFM| 1832| 1838| 1843| 1845| 1845
Watts| 423| 503| 586| 669| 754
Cooling 350

CFM/Ton (a)

| CFM| 1732| 1740| 1746| 1749| 1751
Watts| 363| 440| 518| 597| 678
Cooling 330

CFM/Ton

| CFM| 1632| 1641| 1649| 1654| 1656
Watts| 310| 382| 456| 531| 608
Cooling 310

CFM/Ton

| CFM| 1533| 1543| 1551| 1557| 1561
Watts| 262| 330| 400| 471| 544
Cooling 290

CFM/Ton

| CFM| 1434| 1445| 1454| 1460| 1464
Watts| 219| 283| 349| 416| 485

  • (a) Factory Setting.

General Features

  • NATURAL GAS MODELS
    Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.

  • SAFE OPERATION
    The Integrated System Control is a solid-state device that continuously monitors for the presence of flame when the system is in the heating mode of operation. A dual solenoid combination gas valve and regulator provide additional safety.

  • QUICK HEATING
    Durable, cycle tested, heavy gauge tubular stainless steel primary heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside.

  • BURNERS
    Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas with an LP conversion kit.

  • INTEGRATED SYSTEM CONTROL
    An exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valves, and flame control and includes self- diagnostics for ease of service. Also contains dry contacts for EAC and HUM.

  • ENERGY-EFFICIENT OPERATION
    The furnace is certified by the manufacturer to leak 1.4% or less of nominal air conditioning CFM delivered when pressurized to a .5″ water column with all inlets, outlets, and drains sealed.

  • AIR DELIVERY
    The variable-speed blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from the room thermostat.

  • SECONDARY HEAT EXCHANGER
    The furnace has a special type 29-4C™ stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost.

  • STYLING
    Heavy gauge steel and “wrap-around” cabinet construction are used for strength. Every orientation has at least two venting options. There are no knockouts on the cabinet.

  • FEATURES AND GENERAL OPERATION
    The furnace utilizes a Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon demand for heat from the room thermostat. Complete front service access.

    • Low-energy power venter
    • Vent proving pressure switches.

Features and Benefits

  • 96.0% AFUE ACROSS ALL MODELS

    • Meets utility rebates
    • Lowers utility bills
  • ELECTRICALLY EFFICIENT
    Efficient airflow design reduces electrical energy use

  • 34 INCH TALL

    • Lighter, easier to move, and fit into tight spaces like short basements or tight closets
    • Works great with larger, high-efficiency coils
    • No knockouts
  • 3–WAY MULTI-POISE / DEDICATED DOWNFLOW

    • 6 SKU’s —Upflow / Horizontal Left / Horizontal Right
    • 5 SKU’s —Downflow
    • Added application flexibility and reduction in specification errors
  • AIRFLOW
    At least 400 CFM/ton at 0.5 in. H20 external static pressure; set airflow options down to 290 CFM/ton

  • REGULATORY

    • All models are air-tight; 1.4% or less air leakage as per ASHRAE 193
    • Open vestibule design provides a full 34” high open vestibule
  • DIMENSIONS

    • Width is industry standard: 21”
    • Depth remains approximately 28”
    • The cabinet will be compatible with industry-standard coils, as well as, other accessories
  • INTEGRATED FURNACE CONTROL

    • Setup/Status/Diagnostics/Digital Display
    • No dip switches
    • The last six errors stored
    • Dry contact EAC and HUM connections
    • All Molex connections; no spade terminals
    • Low voltage labeled above and below
    • Rain shield over IFC keeps condensate off the control
  • TUBULAR STAINLESS STEEL PRIMARY HEAT EXCHANGER 29–4C STAINLESS STEEL SECONDARY HEAT EXCHANGER

    • Stainless steel is a more durable, corrosive-resistant material than aluminized steel
    • Integrated rail system for easy access if required
    • Reduces or eliminates the need for baffles
  • VARIABLE SPEED BLOWER MOTOR

    • Increased efficiency
    • Improved home comfort
  • THREE–WAY MULTI-POISE (UPFLOW, HORIZONTAL LEFT AND RIGHT) PLUS DEDICATED DOWNFLOW

    • Easier to specify
    • Shipped ready to install (no kits required)
    • Every model has at least two venting options
    • When horizontally, the trap extends only about 2”
    • Barbed fitting on the trap at the hose connection and on the cabinet transition for the hose has barbed fitting and clamps at both ends for leak resistance.
    • Vent table improvements including longer vent lengths; 2” pipe can be used up to 100K

About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy-efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com.

The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.

  • A952V080CU5-SUB-2B-EN 18 Feb 2022
  • Supersedes A952V080CU5-SUB-2A-EN (June 2021)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Trane User Manuals