TRANE A801X060BM4SC RunTru Central Air Conditioner and Gas Furnace Split System Owner’s Manual
- June 13, 2024
- Trane
Table of Contents
Submittal
Upflow / Downflow / Horizontal Left/Right
Single Stage Non-condensing Gas Fired Furnace
60,000 BTUH
Upflow, Downflow, Horizontal Right/Left
A801X060BM4SC
Note:: Graphics in this document are for representation only. Actual
model may differ in appearance.
Note:: Models may have a “T” in the 12th digit designating they meet
California less than 40 ng/J (NOx) emissions requirements.
Outline Drawing
Table 1. 17.5” Width Cabinet
Product Specifications
MODEL | A801X060BM4SC (a) |
---|---|
Type | Upflow / Horizontal / |
Downflow
RATINGS (b)|
Input BTUH| 60,000
Capacity BTUH (ICS) (c)| 48,700
Temp. Rise (Min.- Max.) °F| 30 – 60
AFUE – Rating (c)| 80
Return Air Temp. (Min. – Max.) °F| 55°F – 80°F
BLOWER DRIVE| DIRECT
Diameter – Width (in.)| 11 X 8
No. Used| 1
Speeds (No.) (d)| CTM – 9
CFM vs. in. w.g.| See Fan Performance Table
Motor HP| 3/4
R.P.M.| 1050
Volts/ Ph / Hz| 120 / 1 / 60
FLA| 9.
COMBUSTION FAN – Type| PSC
Drive – No. Speeds| Direct – 1
Motor RPM| 3300
Volts/Ph/Hz| 120 / 1 / 60
FLA| 0.30
Inducer Orifice| 1.40
FILTER- Furnished?| No
Type Recommended| High Velocity
Hi Vel. (No.-Size-Thk.)| 1 – 16 X 25 – 1 in.
VENT PIPE DIAMETER – Min. (in.) (e)| 4 Round
HEAT EXCHANGER – Type| Aluminized Steel
Gauge (Fired)| 20 – 19
ORIFICES – Main|
Nat. Gas Qty. – Drill Size| 3 – 45
L.P. Gas Qty. – Drill Size| 3 – 56
GAS VALVE| Redundant – Single Stage
PILOT SAFETY DEVICE – Type| 120 V SiNiIgniter
BURNERS-QTY| 3
POWER CONN. – V/Ph/HZ CO| 120 / 1 / 60
Ampacity (Amps)| 12.0
Max. Overcurrent Protection (Amps)| 15
PIPE CONN. SIZE (IN.)| 1/2
DIMENSIONS| H x W x D
Uncrated (in.)| 34 x 17.5 x 28.75
Crated (in.)| 35.5 x 19.5 x 30.87
WEIGHT|
Shipping (Lbs.)/Net (Lbs.)| 132/ 124
(a) Central Furnace heating designs are certified to ANSI Z21.47 – latest
edition.
(b) For U.S. applications, above input ratings (BTUH) are up to 2,000 feet,
derate 4% per 10,000 feet for elevations above 2,000 feet above sea level.
(c) Based on U.S. government standard tests.
(d) 9 Speed constant torque ECM Blower Motor.
(e) Refer to the Installer’s Guide.
(f) The above wiring specifications are in accordance with National Electric
Code, however, installations must comply with local codes.
Airflow Table
Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.)
Model| Tap| Static| 0.1| 0.3| 0.5| 0.7|
0.9
A801X060BM4SC| 1| SCFM| 596| 287| | |
Watts| 38| 42| | |
2| SCFM| 851| 667| 483| 299| 115
Watts| 70| 81| 92| 102| 113
3| SCFM| 1142| 1018| 893| 769| 644
Watts| 141| 156| 172| 187| 203
4| SCFM| 1196| 1079| 961| 844| 726
Watts| 160| 176| 192| 208| 224
5| SCFM| 1362| 1258| 1154| 1050| 946
Watts| 220| 239| 257| 276| 294
6| SCFM| 1416| 1319| 1221| 1124| 1026
Watts| 250| 269| 288| 307| 327
7| SCFM| 1495| 1402| 1309| 1216| 1123
Watts| 287| 307| 327| 347| 367
8| SCFM| 1574| 1487| 1401| 1314| 1228
Watts| 337| 357| 378| 399| 420
9| SCFM| 1983| 1899| 1815| 1730| 1646
Watts| 659| 670| 680| 691| 701
CFM Versus Temperature Rise
Table 2. A801X
Model | CFM Versus Temperature Rise |
---|---|
400 | 500 |
1800 | 1900 |
A801X060BM4SC |
General Features
NATURAL GAS MODELS
Central Heating furnace designs are certified by Intertek for both natural
and L.P. gas. Limit setting and rating data were established and approved
under standard rating conditions using American National Standards Institute
standards.
SAFE OPERATION
The Integrated System Control is a solid state device which continuously
monitors for presence of flame when the system is in the heating mode of
operation.
Dual solenoid combination gas valve and regulator provide additional safety.
QUICK HEATING
Durable, cycle tested, heavy gauge tubular aluminized steel heat exchanger
quickly transfers heat to provide warm conditioned air to the structure. Low
energy power vent blower, to increase efficiency and provide a discharge of
gas fumes to the outside.
BURNERS
Multiport, Inshot burners will give years of quiet and efficient service. All
models can be converted to LL..PP.. gas with LP conversion kit.
INTEGRATED SYSTEM CONTROL
Exclusively designed operational program provides total control of furnace
limit sensors, blowers, gas valve, flame control and includes self diagnostics
for ease of service.
ENERGY EFFICIENT OPERATION
Air-Tite™ cabinet design is certified to <1.4% air leakage per ASHRAE 193
“Method of Test for Determining the Airtightness of HVAC Equipment.”
AIR DELIVERY
The 9 speed constant torque blower motor has sufficient airflow for most
heating and cooling requirements and will switch from heating to cooling
speeds on demand from room thermostat.
STYLING
Heavy gauge steel and” wrap–around” cabinet construction is used for strength.
Every orientation has at least two venting options. There are no knockouts on
cabinet.
FFEEAATTUURREESS AANNDD GGEENNEERRAALL OOPPEERRAATTIIOONN
The furnace utilizes a Silicon Nitride Hot Surface Ignition system, which
eliminates the waste of a constant burning pilot. The integrated system
control lights the main burners upon a demand for heat from the room
thermostat. Complete front service access.
a. Low energy power venter
b. Vent proving pressure switches.
Features and Benefits
80% AFUE on A801X FURNACE MODELS
Lowers utility bills
ELECTRICALLY EFFICIENT
Efficient airflow design reduces electrical energy use
34 INCH TALL
Lighter, easier to move and fit into tight spaces like short basements or
tight closets Works great with larger, high-efficiency coils No knockouts
4-WAY MULTI-POISE
8 SKU’s — Upflow / Downflow / Horizontal Left / Horizontal Right
Added application flexibility and reduction in specification errors
AIRFLOW
At least 400 CFM/ton at 0.5 in. H20 external static pressure
REGULATORY
All models are air tight; 1.4% or less air leakage as per ASHRAE 193 Open
vestibule design provides a full 34” high open vestibule for ease of
installation and service
DIMENSIONS
Width is industry standard: 17.5”
Depth remains approximately 28”
Cabinet is compatible with industry standard coils, as well as, other
accessories
INTEGRATED FURNACE CONTROL
Setup / Status / Diagnostics / Digital Display
No dip switches
Last six errors stored
All Molex connections; no spade terminals
Low voltage labeled above and below
Rain shield over IFC keeps condensate off the control
TUBULAR ALUMINIZED STEEL HEAT EXCHANGER 9 SPEED CONSTANT TORQUE BLOWER
MOTOR
Greater range of operation
Higher efficiency versus a standard PSC blower motor
Taps are electronically selectable at the IFC
FOUR-WAY MULTI-POISE (UPFLOW, DOWNFLOW, HORIZONTAL LEFT AND RIGHT)
Easier to specify
Shipped ready to install (no conversion kits required)
Every model has at least two venting options
About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy efficient indoor
environments for residential applications. For more information, please visit
www.trane.com or
www.americanstandardair.com.
The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.
A801X060BM4-SUB-3B-EN 31 Mar 2023
Supersedes A801X060BM4-SUB-3A-EN (July 2021)
©2023
Documents / Resources
|
TRANE A801X060BM4SC RunTru Central Air Conditioner and Gas Furnace Split
System
[pdf] Owner's Manual
A801X060BM4SC RunTru Central Air Conditioner and Gas Furnace Split System,
A801X060BM4SC, RunTru Central Air Conditioner and Gas Furnace Split System,
Conditioner and Gas Furnace Split System, Furnace Split System, Split System
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>