Recharge Performer
LED PAR Bar with Tripod
Item ref: 151.546UK
User Manual
Please read through this manual thoroughly before use, any damage caused by misuse of product will not be covered by warranty.
Ideal for performers, this complete portable lighting set comprising 4 RGBW PAR lights is powered from a rechargeable T-bar with an internal lithium battery that provides up to 6 hours use without the need for additional power. Easily controlled via DMX, infra-red remote control or internal auto and sound-activated programs selectable from the rear control panel. Each lighting fixture is angle-adjustable to distribute colour washes around the room. Supplied with 2.3m telescopic tripod stand and carry bags making it ideal for transporting to venues and events where power isn’t readily available.
In the box:
Your Recharge Performer should arrive with you in a single carton in good condition. The carton should contain: 1 x T-bar with 4 RGBW PAR cans attached, 1 x 2.3m Tripod Stand, 1 x Remote Control, 1 x UK 3m IEC mains lead, 1 x T-Bar Carry Bag, 1 x Tripod Stand Carry Bag and 1 x user manual.
Warning:
To prevent risk of fire or electric shock, do not expose the unit to rain or damp environments. In the event of a spillage, disconnect the mains and allow the unit to dry out naturally. Qualified personnel should then check the unit before continuing use.
Please do not open cover, contains high voltage. This product is not serviceable or repairable by the end user. Please refer to qualified personnel for service and repair.
Placement:
- Open the included tripod stand legs onto the floor ensuring the thumbscrews are tightened and it’s set down on a flat stable surface away from walkways or where it can be easily knocked over.
- Attach the T-Bar to the top of the stand and tighten the thumbscrew ensuring its secure.
- Keep the unit away from damp or dusty environments.
- Ensure adequate air-flow around the fixture housings.
- Ensure adequate access to controls and connections.
- Do not aim LED or laser output directly into line of sight, as this can result in eye injury.
Cleaning:
- Use a soft cloth with a neutral detergent to clean the casing as required.
- Use a vacuum cleaner to clear ventilation grilles of any dust or debris build-ups.
- Do not use strong solvents for cleaning the unit.
Rear panel and controls:
- Power switch
- IEC input (110-240 Vac, 50/60 Hz)
- Earth screw (do not remove)
- DMX input
- DMX output
- Control panel
- LED display
- Microphone
- Battery charge status
Manual control menu:
Press the “ MENU ” button to enter the settings menu.
Press “ UP ” and “ DOWN ” buttons to navigate through various setting
functions.
Press “ ENTER ” button to confirm the desired setting.
Sequence Number | Display | Sub-Menu | Function/Action |
---|---|---|---|
1 | d001 – d512 | 001 – 512 | DMX address setting |
2 | IP.01 – IP.64 | 001 -512 | IP mode |
3 | A1.01 | A1.01 – A1.18 | Static Colour. Select one of 18 colour options |
4 | A2.01 | A2.01 – A2.32 | Colour Jump. A2.01 (slowest) A2.32 (fastest) |
5 | A3.01 | A3.01 – A3.19 | Multi Colour. Different Colour selection available |
6 | A4.01 | A4.01 – A4.04 | Sound to Light Function |
7 | A5.01 | A5.01 – A5.32 | Strobe Function A5.01(slowest) A5.32 (fastest) |
8 | r000 – r255 | Adjust red colour intensity. r000 (off) r252 (brightest) | |
9 | G000 – G255 | Adjust green colour intensity. G000 (off) G252 (brightest) | |
10 | b000 – b255 | Adjust blue colour intensity. b000 (off) b252 (brightest) | |
11 | u000 – u252 | Adjust white colour intensity. u000 (off) u252 (brightest) |
DMX mode:
The Recharge Performer can be controlled by DMX signal, simply connect the DMX signal source to the DMX input on the unit via a balanced XLR lead. Extra fixtures can be controlled by the same DMX signal by looping through the DMX out on the unit. To enter DMX mode, select A001 from the menu and confirm the correct start address by using the “ UP ” and “ DOWN ” buttons and “ ENTER “. The A on the LED display will begin to flash once it’s received the DMX signal from the controller. This unit has 8 DMX channels as indicated in the tables below:
8 Channel:
Channel | Value | Function |
---|---|---|
1 | 0 -10 | Macro A1 |
11 – 50 | Macro A2 | |
51 – 100 | Macro A3 | |
101 – 150 | Macro A4 | |
201 – 255 | Macro A5 | |
210 – 255 | Red + Green + Blue | |
2 | 0 – 255 | Macro Colour |
3 | 0 – 255 | Speed Adjustment |
4 | 0 – 255 | Master Dimmer |
5 | 0 – 255 | Red Dimmer |
6 | 0 – 255 | Green Dimmer |
7 | 0 – 255 | Blue Dimmer |
8 | 0 – 255 | White Dimmer |
Remote control:
- Blackout on/off
- Colour jump change
- Strobe mode
- Speed adjust -/+
- DMX Channel -/+
- Running effect -/+
- Colour adjust -/+
- Sound active mode
- Colour gradual change
- All lights on
Specifications:
Power supply | 100-240Vac, 50/60Hz |
---|---|
Battery | 12V 7200maH lithium rechargeable battery |
Battery life | Up to 6 hours |
Fuse rating | F3A |
Effects | 4x RGBW LED PAR |
Modes | Auto, sound, master/slave, DMX512 |
DMX channels | 8CH |
Dimensions: stand | 900 x 130 x 130mm (collapsed) |
Height adjustment | 1.8 to 2.3m |
Weight: stand | 1.3kg |
Dimensions: effects bar | 740 x 210 x 150mm |
Weight: effects bar | 3.7kg |
Troubleshooting:
No power | Check unit has sufficient charge if using without power source |
---|
Check mains voltage is correct and outlet is switched on
Check IEC lead and fuse (if fuse continually blows, refer to your dealer)
No light output| Check control panel mode settings
Check DIN connections for each fixture
Unresponsive to DMX| Check that unit is in DMX mode and ensure the “d” on the
DMX address flashes to confirm it’s receiving a DMX signal
Check DMX controller is not set to black out
Check DMX controller is on correct fixture/page
Check master dimmer value
Check correct DMX address is set
Check DMX connection and leads
Overheating/ cutting out| Ensure adequate ventilation and unit is not too
close to a heat source
This product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life. The goods must be disposed of according to your local council guidelines.
Errors and omissions excepted.
Copyright© 2023 AVSL Group Ltd, Unit 2 Bridgewater Park,
Taylor Road, Trafford Park, Manchester. M41 7JQ.
AVSL (Europe) Ltd, Unit 3D North Point House,
North Point Bus. Park, New Mallow Road, Cork, Ireland.
151.546UK User Manual
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>