tgs CROWN CF52374-L-ES-SS 52 Inch Indoor LED Ceiling Fan Installation Guide

June 13, 2024
tgs

tgs CROWN CF52374-L-ES-SS 52 Inch Indoor LED Ceiling Fan

CROWN -CF52374-L-ES-SS -52 -Inch -Indoor -LED -Ceiling -Fan -PRODUCT
IMAGE

Product Information

Product Name: CROWNTM 52-INCH INDOOR LED CEILING FAN

Features:

  • 4 Blades
  • Pull Chain for controlling fan speed and light
  • LED Module for energy-efficient lighting

Dimensions:

  • Overall Size: 52 inches
  • Mounting Bracket: 5-1/4 inches x 2 inches x 10-1/2 inches
  • Support Rod: 15-3/4 inches

Product Usage Instructions

Step 1: Fan Assembly

  1. Place washers for blade screws on each blade screw.
  2. Attach the blades to the fan motor using the blade screws and washers. Use the center band to secure the blades.

Install Mounting Bracket

  1. Loosen the two canopy mounting screws on the downside face of the mounting bracket.
  2. Install the mounting bracket onto the electrical junction box in the ceiling using the provided machine screws, washers, and lock washers.
  3. Ensure the mounting bracket is centered over the electrical junction box and securely attached.
  4. Pull the electrical wires in the junction box down and through the mounting bracket.

Loosen the two canopy mounting screws on the downside face of the mounting bracket. Back them out about half way. This will allow for easier installation of the ceiling canopy later .

Install the mounting bracket onto the electrical junction box in the ceiling using two machine screws, two washers and two lock washers .

The mounting bracket has slotted holes to enable it to move sideways for proper alignment. Make sure the mounting bracket is centered over the electrical junction box and that it is securely attached .

NO MOVEMENT SHOULD OCCUR BETWEEN THE MOUNTING BRACKET AND THE ELECTRICAL JUNCTION BOX.
Pull the electrical wires in the junction box down and through the mounting bracket.

Hanging the Fan Body

  1. Take note of the half ball on the end of the support rod, which has a grooved side.
  2. Place the half ball in the center of the mounting bracket, aligning the keyway pin on the ball with the keyway on the bracket.
  3. Turn the fan left and right slightly to ensure it is seated properly on the bracket with the keyway pin in place.
  4. Trim the lead wires, leaving about six inches of each wire extending from the support rod.

Notice the half ball on the end of the support rod is grooved down one side.

CROWN -CF52374-L-ES-SS -52 -Inch -Indoor -LED -Ceiling -Fan -FIG
\(10\)
This Keyway fits over the small keyway pin on the inside of the mounting bracket and keeps the ceiling fan from spinning on the mounting bracket. Using your step ladder, lift the fan and place the half ball in the center of the mounting bracket with the keyway pin inserted into the keyway on the ball. Turn the fan left and right slightly to make sure it is seated on the bracket with the keyway pin in the keyway .

Trim the lead wires, leaving about six inches of each wire extending from the support rod.

Making the Electrical Connections **

**

Follow the instructions below to operate the ceiling fan using the pull chain(s) and switches:

  1. Attach the GREEN wire (connected to the half ball) to the GROUND wire in the junction box. The GROUND wire is usually a bare copper wire without plastic insulation or covered in green plastic insulation.
  2. Make additional electrical connections as per your specific wiring setup and local electrical codes.

To operate your ceiling fan with the pull chain(s) and switches mounted on your fan, follow the instruction below.

Attach the GREEN wire (connected to the half ball) to the GROUND wire in the junction box. The GROUND wire is usually a bare copper wire without plastic insulation. It could also be covered in green plastic insulation. Attach the BLACK wire and BLUE wire from the ceiling fan to the BLACK wire in the junction box. Attach the WHITE wire from the ceiling fan to the WHITE wire in the junction box.
Fold the connected wires

and push them up inside the electrical junction box with the BLACK and BLUE wires to one side and the WHITE and GREEN to the other side. Make sure the wire nuts do not come loose during this operation.

Installing Ceiling Canopy onto Mounting Bracket
Secure the ceiling canopy onto the mounting bracket using canopy mounting screws.

Installing Glass Shade
The LED module is pre-installed on the mounting plate. Place glass cover on bottom motor plate and rotate until secure .

N ote: If you are not familiar with electrical codes and wiring procedures, it is recommended to have a qualified electrician install the ceiling fan.

Hardware Package Included

Hardward Package                                  Quantity

  • S1. Blade Screws & Washers             13
  • S2. Machine Screws                             2
  • S3. Machine Screws                             2
  • 54. Wood Screws                                  2
  • S5. Washers                                           2
  • S 6. Lock Washers                                2
  • S7. Star Washers                                  2
  • S 8. Wire Nuts                                     3
  • S9. Paper Washers                             13
  • S10. Balance Kit                                   1

Fan Parts Included

Quantity

  1. Mounting Bracket                   1
  2. Support Rod & Cotter Pin    1
  3. Canopy                                     1
  4. Coupler Cover                         1
  5. Fan Motor Assambly             1
  6. Glass                                         1
  7. Fan Blade                                4

Exploded View

CROWN -CF52374-L-ES-SS -52 -Inch -Indoor -LED -Ceiling -Fan -FIG
\(22\)

Safety Instructions

READ ALL SAFETY INFORMATION AND INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN INSTALLING THE FAN. IF YOU ARE NOT FAMILIAR WITH NATIONAL AND LOCAL ELECTRICAL CODES AND BASIC ELECTRICAL WIRING PROCEDURES WE RECOMMEND THAT YOU HAVE A QUALIFIED ELECTRICIAN INSTALL YOUR NEW CEILING FAN. SAVE INSTRUCTIONS.

  • Avoid the risk of electrical shock be sure to shut off power at main fuse or circuit breaker box before installing or servicing fixture.
  • Make sure that all wiring conforms to national and local electrical codes. If you are in question obtain a copy of codes and wire the fan accordingly. Never leave bare wire uncovered, use wire nuts to cap all connections. Plastic electrical tape not recommended.
  • Basic requirements for a ceiling fan installed with lights are 120V AC-60Hz on a grounded circuit with a 15 amp breaker or fuse. Make sure that your electrical system and choice of location meet these requirements.
  • If the location where you plan to install your fan does not already have an electrical outlet, hire a licensed electrician to run wiring and install an outlet box designed for ceiling fans or heavy fixtures. Outlet box should be able to support a minimum moving weight of 50 pounds and marked “Acceptable for Fan Support” (Plastic outlet boxes not recommended for ceiling fan installation).
  • If you plan to use an existing electrical location check to make sure that the outlet box is not PLASTIC, that it is securely attached and able to support at least 50 pounds of moving weight marked “Acceptable for Fan Support”. If you have any questions, outlet boxes and support systems for ceiling fans are available at most hardware and do-it-yourself centers. In most cases your Truly Green Solutions dealer will have all the necessary products for the proper and safe installation of your ceiling fan.
  • The location you choose should have a minimum clearance of 20 inches from any wall to the blade tip at any point in its rotation and a minimum of 7 feet from blade level to floor and 10 inches from the blades to the ceiling.
  • This ceiling fan was not designed for installation in any location where it might be exposed to moisture or high humidity. Installation in this type of location could be UNSAFE, will most likely damage the fan and its finish…and will VOID YOUR WARRANTY.
  • Every effort has been made to provide you with proper instructions for the safe installation of this ceiling fan. Y ou could however, encounter situations or problems not covered in this manual. Should this occur, please refer to a do-it-yourself wiring handbook or hire a qualified electrician to install your fan.
  • Lubrication of your new ceiling fan is not necessary. The ball bearings have been adequately charged with grease and permanently sealed at the factory so that, under normal conditions, further attention is not necessary.
  • NOTE: The safeguards provided by these safety instructions and by any separate installation instructions are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and care are factors which can not be built into this product. These factors must be supplied by the person(s) installing, caring for and operating fan.

Warning:

  • To reduce the risk of fire, electrical shock, or personal injury, mount this fan to an outlet box marked “Acceptable for Fan Support of 22.7 kg (50 lbs )” or less and use Mounting Screws provided with the outlet box. CAUTION: Install the primary mounting means and use only the hardware provided with the fan.
  • To reduce the risk of personal injury take care not to bend the blade brackets when installing the brackets, balancing the blades or cleaning the fan. Be careful not to insert foreign objects in between rotating fan blades.
  • To reduce the risk of fire or electrial shock, do not use this fan with any solid-state speed control device.
  • The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and careful attention to detail are factors which cannot be built into this product. These factors must be supplied by the person or persons installing, caring for, and operating the unit.

Installation Instructions

Remove the screws from coupler cover and lift the coupler cover and set aside. Remove the screws from top plate located on the motor yoke. Lift top plate and set aside.
Time Saver: Washers for blade screws can be set on each blade screw prior to installing blades. Locate 12 pcs blade attachment screws and washers in the hardware pack. Slide a blade through the center band and align holes. Insert 3 pieces blade screws and washers with fingers. Tighten securely with a phillips screwdriver. Repeat for the remaining blades. Reattach top plate to motor yoke and install it by aligning the key slot holes on the motor yoke using previously removed screws.
Note: The reverse switch must be set in the rectangular hole labeled on the top plate.
Note: If you are using an extended support rod, (longer than the one supplied with your fan) remove the half ball from the support assembly and attach it to the extended support rod at this point. Make sure to retighten the set screw and insert the safety pin Back off (loosen) the set screws (2) in the support rod coupler until the inside of the channel is clear of the screw tip. Remove and save the safety pin and washer on the end of the support rod assembly. Slide the ceiling canopy onto the support rod, followed by the support rod coupler cover .

Feed the electrical wires from the fan housing through the support rod. Thread the support rod into the support rod coupler until the safety pin can be inserted through the hole in both the rod and coupler. Insert the safety pin through the hole in the support rod coupler and support rod then attack. washer into safety pin and the retaining clip on the other side. Tighten both set screws and safety screw on the support rod coupler.

Operation

The pull chain located on the switch housing controls the speed of your fan. When the fan is OFF, pull the chain once for HIGH speed, twice for MEDIUM speed, three times for LOW speed and a fourth time to turn it off again. Turn fan completely off before moving the reverse switch. Set reverse switch to recirculate air depending on the season: LEFT position in summer (1), RIGHT position in winter (2). IMPORTANT: If the reverse switch is set in the (3) middle position the fan will not operate. Attach the pull chain extensions supplied or custom pull chains (sold separately) to ends of the pull chains.

CROWN -CF52374-L-ES-SS -52 -Inch -Indoor -LED -Ceiling -Fan -FIG
\(17\)

CROWN -CF52374-L-ES-SS -52 -Inch -Indoor -LED -Ceiling -Fan -FIG
\(18\)

Maintenance:
Your fan requires very little maintenance. Cleaning of the housing should be done with a damp soft cloth (NO CLEANING AGENTS). On the blades, use a duster or dry cloth because any moisture could cause the blades to warp.
Conforms To D.O.E. EPACT Regulation

Troubleshooting Guide

If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly, installation, or wiring. In some cases these installation errors may be mistaken for defects. If you experience any faults please check this troubleshooting guide.CROWN -CF52374-L-ES-SS -52 -Inch -Indoor -LED
-Ceiling -Fan -FIG \(19\) CROWN
-CF52374-L-ES-SS -52 -Inch -Indoor -LED -Ceiling -Fan -FIG
\(20\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals