SIEMENS OCT200.KNBA KNX IoT to BACnet IP Gateway Instruction Manual
- June 13, 2024
- SIEMENS
Table of Contents
SIEMENS OCT200.KNBA KNX IoT to BACnet IP Gateway
Product Information
- Product Name: KNX IoT to BACnet IP gateway
- Model: OCT200.KNBA
- Manufacturer: Siemens Smart Infrastructure
- Features
- Bridge between BACnet IP and KNX IoT mesh network
- Wireless communication via KNX IoT over Thread
- Supports BACnet IP over Ethernet connection
- Mains-powered by AC 100-240V (with external power adapter)
- Commissioning and configuration via web UI over WLAN using PC or smartphone
- LED indication of power and network connection state
Use
Wireless communication via KNX IoT over Thread exchanges data with sensors and
tools over a wireless Thread network.
Typical application:
- Commercial office building
- Public infrastructure
Functions
- 2 push buttons reset the device to factory settings, switch on/off WLAN or join Thread network
- The LED indicate:
- Power status, WLAN connection, Thread connection
- Device restart
- Factory reset
- Operation state
- Commissioning and configuration via web UI using PC or smartphone
- BACnet IP over Ethernet
- IPv4 and DHCP client
- Factory-assigned MAC address
- BACnet IP setting and data server
- Time synchronization from BACnet client
Mechanical design
Gateway is designed for wall mounting and ceiling mounting.
The device has 2 parts:
- Plastic housing with electronic components (A)
- Mounting plate (B)
Operation
Type summary
Product number| SSN NO.| Operating voltage|
Description
---|---|---|---
OCT200.KNBA| S55812-Y102| DC 12 V| KNX IoT to BACnet IP gateway
Delivery
When ordering, specify name and product number, e.g.: KNX IoT to BACnet IP
gateway OCT200.KNBA.
Name | Quantity |
---|---|
OCT200.KNBA | 1 |
Power adapter | 1 |
Mounting plate | 1 |
Mounting instructions | 1 |
Set of screws and plastic insert | 1 |
Equipment combinations
Type of units | Product number | SSN NO. |
---|---|---|
Thread room sensor | QAA2890/WI QFA2890/WI QPA2892/WI | S55720-S550 S55720-S551 |
S55720-S552
Thread mesh extender| OCT100.R| S55812-Y101
Product Documentation
Title | Document ID |
---|---|
Mounting instruction | A6V13434940 |
Operation manual | A6V12905642 |
CE declarations | A5W00299442A |
RCM | A5W00299447A |
UKCA | A5W00299443A |
Environmental product declaration | A5W00284134A |
Related documents such as environmental declarations, CE declarations, etc., can be downloaded from the following Internet address: www.siemens.com/bt/download
Safety
CAUTION National safety regulations
Failure to comply with national safety regulations may result in personal
injury and property damage.
- Observe national provisions and comply with the appropriate safety regulations.
NOTICE-Radio frequency energy
Interference to radio communications
- Install and use equipment in accordance with installation guide.
- Read all regulatory compliance information.
Mounting
- The device is designed for wall mounting and ceiling mounting.
- Do not install the device on a horizontal surface.
- Install power supply above ceiling tiles.
- Install on inside wall (not an outside wall!) of the room to be air conditioned; not in recesses, behind curtains, above or close to heat sources or shelves and not on walls where a chimney is located. Do not expose the unit to spot lights or direct sunlight.
- Install the gateway in the occupied space about 2.2 m above the floor and at least 20 cm from the next wall.
Mounting instructions
Mounting instructions are enclosed in the package.
Colors and patterns
In the following table:
- Short press (<2 s) means short press the push button.
- Middle press (5…20 s) means middle press the push button.
- Long press (≥20 s) means long press the push button.
LED A
LED color| Device status| LED pattern| Push button
operation
---|---|---|---
Off| Unpowered device or device is switched off.| Off| N/A
Green| Start up (e.g. device is powered on)| Fast flashing (100 ms on / 100 ms
off)| N/A
Normal (connected)| On
Firmware downloading
Firmware installation| Fast flashing (100 ms on / 100 ms off)
Orange| Factory reset| Fast flashing (100 ms on / 100 ms off)| Long press
button A to start factory reset
Red| Hardware error| Fast flashing (100 ms on / 100 ms off)| N/A
Green| Confirm key press| Flashing (¹/₄ s on / ⁷/₄ s off) until button
pressing stops| Middle press button A
LED B
LED color| Device status| LED pattern| Push button
operation
---|---|---|---
Off| LAN/WLAN is not connected or switched off.| Off| N/A
Green| WLAN access is switched on.| On for 3 s| Middle press button A
Device joins Thread network.| Fast flashing (100 ms on / 100 ms off)| N/A
Orange| WLAN access is switched off.| On for 3 s| Middle press button A
LED C
LED color| Device status| LED pattern| Push button
operation
---|---|---|---
Orange| Thread initial status (Device is not defined or joined a network.)|
On| N/A
Green| Commissioning mode| Fast flashing (100 ms on / 100 ms off)| N/A
In operation| On
Joining| Flashing (¹/₄ s on / ⁷/₄ s off)| Short press button B ****
Red| Connection lost| Flashing (¹/₄ s on / ⁷/₄ s off)| N/A
Maintenance
The device is designed for maintenance-free operation. This symbol or any other national label indicate that the product, its packaging, and, where applicable, any batteries may not be disposed of as domestic waste. Delete all personal data and dispose of the item(s) at separate collection and recycling facilities in accordance with local and national legislation. For additional details, refer to Siemens information on disposal.
Regulatory compliance information
FCC Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation
FCC Caution: Changes or modifications not expressly approved by Siemens Switzerland Ltd. could void user authority to operate the equipment. United States representative https://new.siemens.com/us/en/products/buildingtechnologies/home.html
IC Statement
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
Radiofrequency radiation exposure statement
This equipment complies with FCC and IC radiation exposure limits set forth
for an uncontrolled environment. This equipment should be installed and
operated with a minimum distance of 20 cm between the radiator and your body.
This transmitter must not be co-located or operated in conjunction with any
other antenna or transmitter.
United Kingdom conformity assessed
Contact for regulatory topics: (GB) Siemens plc, Sir William Siemens House,
Princess Road, Manchester, M20 2UR Radio equipment directive
Simplified EU Declaration of Conformity
Hereby, Siemens Switzerland Ltd declares that the radio equipment type
OCT200.KNBA is in compliance with Directive 2014/53/EU. The full text of the
EU declaration of conformity is available at the following internet address:
https://siemens.com/bt/download.
Warranty
Technical data on specific applications are valid only together with Siemens products listed under “Equipment combinations”. Siemens rejects any and all warranties in the event that third-party products are used.
Technical data
Power adapter
Input characteristics
Rated input voltage| AC 100…240 V
Operation range| AC 90…264 V
Rated input frequency| 50…60 Hz
Input current| Max. 0.8 A at AC 100/240 V input & load 1 A
Standby power consumption| ≤ 0.1 W at AC 240 V input & no load
Output characteristics
Rated output voltage| DC 12 V
Representative current| 1 A
Output voltage range| DC 11.4……… V
Turn on delay time| Max. 3 seconds at AC 100 V & max. load
Cable length
Length of prefabricated connecting cable| 1.5 m
OCT200.KNBA
Power supply
Operating voltage| DC 12 V
Power consumption| Max. 12 W
Radio communication
Frequency range| 2.4…2.4835 GHz
Maximum transmission power(for EU)| 11.33 dBm (Thread)/19.27 dBm (WLAN)
Thread range| ≤ 100 m, depending on application and building
WLAN range| ≤ 100 m, depending on application, mobile device, and building
Thread protocol| IEEE 802.15.4
WLAN protocol| IEEE 802.11.b/g/n
Interface
Ethernet Type
Cable
Interface type
Bit rates
| RJ45
CAT 5 or CAT 5e, non-shielding
100BASE-TX, IEEE 802.3 compatible
10/100 Mbps, auto-sensing
Ambient conditions and protection classification
Protection degree of housing| IP30 according to EN60529
Protection class
Power adapter
OCT200.KNBA
|
II
III
Environmental conditions
Storage
Climatic conditions
Temperature
Humidity
Transport
Climatic conditions
Temperature
Humidity
Operation
Climatic conditions
Temperature (housing with electronics)
Humidity
|
-25…+70 °C
5…95 % r. h. (non-condensing)
-25…+70 °C
5…95 % r. h. (non-condensing)
0…50 °C
5…95 % r. h. (non-condensing)
Standards, directives and approvals
Product standard| EN 62368-1, EN 301489-1, EN 301489-17 EN 300328, EN IEC62311
Electromagnetic compatibility (Applications)| For use in residential, commerce
and light- industrial environments
EU conformity (CE)| A5W00299442A )
RCM conformity| A5W00299447A )
UKCA conformity| A5W00299443A )
RoHS| Directive 2011/65/EU restriction of the use of certain hazardous
substances in electronic equipment
Environmental compatibility| The product environmental declaration
(A5W00284134A ) contains data on environmentally compatible product design
and assessments (RoHS compliance, materials composition, packaging,
environmental benefit, disposal).
General
Materials and colors| ABS, RAL9003
Packaging| Corrugated cardboard
Weight including package| Approx. 447 g
Dimensions
Issued by Siemens Switzerland Ltd Smart Infrastructure Global Headquarters
Theilerstrasse 1a CH-6300 Zug
+41 58 724 2424
www.siemens.com/buildingtechnologies
© Siemens Switzerland Ltd, 2023
Technical specifications and availability subject to change without notice.
References
- Smart Information Delivery
- Building technology - Siemens Global
- Building Technologies - Siemens USA
- Smart Information Delivery
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>