argo AIM08EMX Domestic Air To Water Heat Pump User Manual
- June 13, 2024
- argo
Table of Contents
AIM08EMX Domestic Air To Water Heat Pump
CONTROL PANEL’S USER MANUAL EN MANUALE D’USO PANNELLO DI CONTROLLO IT MODE
D’EMPLOI DU PANNEAU DE CONTROLE FR
Control panel for air to water Inverter heat pump Pannello di controllo per
pompa di calore Inverter aria / acqua Panneau de contrôle pour pompe à chaleur
Inverter air / eau
37.4254.086.09 10/2021
EN CONTENTS
1 – Presentation of control elements ……………………………………………………………………………….. 2 2 –
Operation………………………………………………………………………………………………………………… 3 3 – Settings
………………………………………………………………………………………………………………….. 5 4 – Graphs
………………………………………………………………………………………………………………….. 11
1 – PRESENTATION OF CONTROL ELEMENTS
CONTROL PANEL
BUTTONS BUTTON ON/OFF – BACK TO THE PREVIOUS MENU
BUTTON UP BUTTON DOWN SET SETTINGS BUTTON
DISPLAY – MAIN SCREEN WITH UNIT SWITCHED ON
ON: HEAT PUMP IN OPERATION OFF: HEAT PUMP STOPPED BLINKING: HEAT PUMP IS
STARTING
RETURN WATER TEMPERATURE
ON: PUMP IN OPERATION OFF: PUMP STOPPED
35 . 0°C [35 . 0°C]
ON: BACKUP HEATING ACTIVE OFF: BACKUP HEATING NOT ACTIVE
RETURN WATER SETPOINT
ON: “ECO” OPERATION ACTIVE OFF: “ECO” OPERATION NOT ACTIVE
2
2 – OPERATION
EN
2.1 – SWITCHING THE UNIT ON/OFF
· When the unit is powered, the following screen appears:
– – – – – – –
· To turn on the unit, press and hold the button sequentially:
for 3 seconds. The following two screens will appear
UNIT MODEL
model r 01 D I SPLAY r 01
DISPLAY OR REMOTE
SOFTWARE VERSION OF THE UNIT
SOFTWARE VERSION OF THE DISPLAY
· Then the main screen will appear:
35 . 0°C [35 . 0°C]
3
EN
· To turn off the unit, press and hold the button sequentially:
for 3 seconds. The following two screens will appear
– – – – – – –
NOTE: Once the unit has been switched off, the water pump may continue to
operate in order to prevent frost in the pipes.
2.2 – SETPOINT MODIFICATION (RETURN WATER TO THE UNIT)
If the fixed setpoint has been selected (P05 = 1, see parameter list), you can
set the setpoint manually. To change the setpoint, press the buttons or until
the desired setpoint is displayed in the second line.
2.3 – KEYBOARD LOCKED / UNLOCKED
To lock the keyboard so that it is not possible to accidentally press the
buttons, press the buttons and simultaneously for 3 seconds. The following
screen will appear:
KEYBOARD LOCKED
Repeat the same operation to unlock the keyboard. The following screen will
appear:
KEYBOARD UNLOCKED
2.4 – DEFROST
During the defrost cycles of the unit, the following screen will appear:
35 . 0°C DEFROST
The first line will display the return water temperature. 4
3 – SETTINGS
EN
3.1 – USER PARAMETERS SETTING – LEVEL 1
· Press the SET button once to enter the menu level 1 (see table):
Name Pump Speed selection
Water ow Sensors reading Working mode selection Error List Language selection
Description
Notes
Select the water pump speed and Once desired speed has been se-
read back the corresponding water ow
lected, press button the selection
to confirm
Water ow level bar
List of main sensors reading
RWT, SWT, OAT, Water Flow, Pump Speed
HEAT: heating mode selected COOL: cooling mode selected
Selection available only if P14 = 1 See parameter P04
List of last 10 errors
Hold button for 5 seconds to delete the list (possible only if P07 = 1)
0= French 1= English 2= Italian
See parameter P08
· Utilise buttons or to select the desired parameter. · Press SET to visualise
or modify the selected parameter. · Press SET to confirm any changes.
· Press the button to return to the previous menu.
3.2 – AUTHORIZED SERVICE CENTER PARAMETERS SETTING – LEVEL 2
· Press and hold SET button for 3 seconds to enter the menu level 2 (see table
on the next page). · The parameter for the setting of the pump mode will be
displayed. · Press SET to modify the pump mode (see P03) or press buttons or
to enter the parameter list (the list
is accessible only by password). · Enter the password and confirm with the SET
button. · Press buttons or to scroll through the parameters. · Press SET to
visualise the selected parameter. · Press and hold SET button for 3 seconds to
modify the parameter. The parameter value will blink to indicate
the change in progress. · Press buttons or to change the parameter value.
· Press SET to confirm or to cancel.
· Press the button to return to the previous menu.
LEGEND OF ACRONYMS (CONTAINED IN THE PARAMETER TABLES)
DHW: DOMESTIC HOT WATER RWT: RETURN WATER TEMPERATURE SWT: SUPPLY WATER
TEMPERATURE OAT: OUTDOOR AIR TEMPERATURE ICT1: OUTLET (HEAT) / INLET (COOL)
HEAT EXCHANGER (PLATE-TYPE) ICT2: INLET (HEAT) / OUTLET (COOL) HEAT EXCHANGER
(PLATE-TYPE) OCT: OUTDOOR COIL TEMPERATURE CDT: COMPRESSOR DISCHARGE
TEMPERATURE CTST: COMPRESSOR TOP SHELL TEMPERATURE ICP: CONDENSING PRESSURE
(HEAT) / EVAPORATING PRESSURE (COOL) C/E: CONDENSING TEMPERATURE (HEAT) /
EVAPORATING TEMPERATURE (COOL)
5
3.2.1 – SETTING OF GENERAL PARAMETERS
EN
6
Num. Description
Unit Floor
Default value
Range
Fan coils Radiators Min. Max.
Increment
Value description
Notes
– Sensors reading
Read only
RWT – SWT – OAT – C/E – ICT1 – ICT2 – OCT CDT – CTST – ICP Water ow Pump speed Fan speed
List of all the sensors’ values
P02 On-Off hysteresis °C 1.5
1.5
1.5
0.5
10
0.5 Hysteresis of heat pump restart on the return See graph “ON/OFF HYSTERESIS” water temperature
P03 Water pump mode
–
Auto (0) Auto (0) Auto (0) Auto (0) ON (1) 1
AUTO= Auto mode ON= Water pump always ON
P04 Working mode –
Heat (0) Heat (0) Heat (0) Heat (0) Cool (1) 1
HEAT= heating mode selected COOL= cooling mode selected
Selection available only if P14 = 1
P05 Setpoint mode –
0
0
0
0
1
1
0= Automatic setpoint (climatic curve)
In 2-zones application, if auto mode is selected
1= Fixed setpoint (user selection)
the warmest (heating mode) or the coldest (cooling
mode) setpoint is selected
P06 Secondary water –
0
0
0
0
1
1
0= Unit pump only
pump
1= Secondary pump installed (primary/second-
ary circuit)
P07 Error list reset
–
0
0
0
0
1
1
0= Error list reset forbidden
enable
1= Error list reset allowed
If P07 = 1 go to the error list and hold the button
for 5 seconds to clear the list
P08 Language
–
English (1) English (1) English (1) 0
2
1
0= French
1= English
2= Italian
P09 Backup heating –
0
0
0
0
3
1
0= Backup heating disabled
Values 2 and 3 are valid only for units equipped
mode
1= External backup heating enabled
with backup heating
2= Internal backup heating enabled
3= External + Internal backup heating enabled
P10 Backup heating Min. 20
20
20
5
120
1
Time of heat pump functioning before backup Valid only if P40 < OAT < P12
delay
heating activation
See graph “OPERATING RANGE OF HEAT PUMP/
BACKUP HEATING”
P11 Boost mode
–
0
0
0
0
1
1
0= Boost mode disabled
1= Boost mode activated
If P11 = 1, backup heating (according to P09) will be immediately activated up to the setpoint, then P11 is automatically reset to 0
P12 Backup heating °C 0
0
0
P40
+35
1
Heating mode:
threshold
OAT > P12: backup heating disabled
OAT < P12: backup heating enabled
See graph “OPERATING RANGE OF HEAT PUMP/ BACKUP HEATING”
P13 DHW valve delay Sec. 15
15
15
15
300
5
Time to move the DHW valve from one posi-
tion to the other
EN
7
Num. Description
P14 Working mode selection
P20 Alarm contact function
Unit Floor
–
0
–
0
P21 DHW contact
–
0
function
P22 Secondary setpoint
°C 50
P23 Maximum DHW h
5
production time
P30 Minimum heating Min. 60 time of the system
P31 Antifreeze func- °C 1 tion threshold
P32 Antifreeze threshold (P31) hysteresis
P33 Minimum water ow
°C 1 m3/h 0,3
P40 Heat pump threshold
°C -20
P41 Defrost
–
0
P50 Factory default –
0
reset
P51 Maximum heat °C 58 pump setpoint
P52 Return water
°C 15
minimum tempe-
rature
Default value
Fan coils Radiators
0
0
0
0
0
0
Range Min. Max. 01 06
01
Increase 1 1
1
Value description
0= Working mode selected by thermostat 1= Working mode selected with P04
0= Alarm 1= Defrost 2= Alarm or defrost 3= DHW 4= Alarm or DHW 5= Defrost or
DHW 6= Alarm o defrost or DHW
0= DHW 1= Secondary setpoint
50
50
5
5
60
60
1
1
1
1
20 58 0,5 1 24 1 10 120 5
-20 +35 1
15
0,5
Setpoint used if P21 = 1 and DHW contact is closed
Minimum system heating time after DHW production
If OAT < P31, antifreeze function is activated in order to avoid water
freezing in the pipings. Hysteresis on P31
0,4
0,4
-20
-20
0
0
0
0
58
58
15
15
0,3 4,0 0,1 -20 P12 1
01
1
01
1
20 58 0,5
5 20 1
Minimum water ow threshold
Heating mode: OAT < P40: heat pump disabled OAT > P40: heat pump enabled
If P41 is set to 1 and unit is running in heating mode, a defrost will start.
At the end of defrost cycle P41 is automatically reset to 0
If P50 is set to 1, all parameters will be reset to the default value. After
the reset has been done, P50 is automatically reset to 0
Maximum setpoint for the heat pump. If calculated setpoint is > P51, heat pump
will stop when P51 is reached and setpoint can only be reached with backup
heating (if enabled).
Heating mode: RWT < P52: heat pump disabled and backup heating activated. RWT
P52: heat pump enabled.
Notes
If P21= 0, when DHW contact is closed the unit will automatically manage the
DHW production. If P21 = 1, when DHW contact is closed the unit will use the
secondary setpoint P22 (heating only).
Valid if there is a system request See graph “ANTIFREEZE FUNCTION” See graph
“ANTIFREEZE FUNCTION” If water ow drops below P33, water ow error will appear
and the unit will stop See graph “OPERATING RANGE OF HEAT PUMP/BACKUP HEATING”
See graph “RETURN WATER MINIMUM TEMPERATURE PROTECTION”
EN
8
Num. Description P53 Special command
P60 Eco mode power limit
P61 Eco mode enable
P62 DHW mode
Unit
Floor
Default value Fan coils Radiators
Range Min. Max.
Increase
Value description
–
0
0
0
0 999 1
0= Special command desabled 1= Air purge function activation
% 75
75
75
30 100 1
–
1
1
1
–
0
0
0
01
1
02
1
0= Eco mode command disabled 1= Eco mode command enabled
0= ECO 1= AUTO 2= FAST
Notes
ECO: maximum efficiency FAST: maximum yield AUTO: ECO if ON/OFF contact is
open
FAST if ON/OFF contact is closed
9
Num. P101 P105 P106 P120 P121 P123 P130 P131
P132
P150
P151 P152 P160 P161
Description
Unit
Plant type
–
(single zone or zone 1)
Maximum climatic
°C
curve setpoint
(single zone or zone 1)
Minimum climatic
°C
curve setpoint
(single zone or zone 1)
Temperature for maxi- °C mum setpoint (single zone or zone 1)
Temperature for mini- °C mum setpoint (single zone or zone 1)
Cooling setpoint
°C
(single zone or zone 1)
Calculated setpoint °C (single zone or zone 1)
Lowest cooling
°C
setpoint with 0-10V
control
(single zone or zone 1)
Highest cooling
°C
setpoint with 0-10V
control
(single zone or zone 1)
0-10V signal function (single zone or zone 1)
Maximum 0-10V
°C
setpoint shift
Manual setpoint shift °C
Mixing valve delay
sec
Mixing valve control type
Floor
35 20 -7 17 23
23
30
0
5 0 60 0
Default value
Range
Fan coils Radiators Min. Max.
0
0
2
45
50
30 55
35
40
20 40
-7
-7
-20 P121
17
17
P120 +35
12
–
10 30
Read only
12
–
10 P132
30
–
P131 30
0
0
0
4
5
5
0
0
60
60
0
0
1
10
0
10
30 300
0
1
Increase 1 0,5 0,5 0,5 0,5 0,5
0,5
0,5
1
0,5 0,5 5 1
Value description 0= Under oor 1= Fan coil 2= Low temperature radiators
0= Disabled 1= Thermal load 2= Setpoint command 3= Thermal load on outdoor
unit 4= Setpoint command on outdoor unit
0 = 230 Vac control (2 or 3 points) 1 = 0-10V control
Notes
When P101 is changed, P105 / P106 / P120 / P121 P123 are reset to the
corresponding default value.
Only for heating mode See graph “CLIMATIC CURVE”
See graph “CLIMATIC CURVE”
Set to the minimum expected regional temperature See graph “CLIMATIC CURVE”
If P121 < P120, P120 is automatically set to P121 See graph “CLIMATIC CURVE”
In cooling mode the setpoint is fixed and it corresponds to P123
Active only if P150 = 1, it corresponds to a signal of 10V See graph “0-10V
CONTROL”
Active only if P150 = 1, it corresponds to a signal of 0V. If P132 < P131,
P132 is automatically set to P131 See graph “0-10V CONTROL”
If P150 = 3 or 4, 0-10V signal is read on outdoor unit only and signals on
zone 1 and 2 will be ignored See graph “0-10V CONTROL”
Active only in heating mode and if P150 = 1. It represents the shift on the
setpoint with a signal of 10V. (See graph “0-10V CONTROL”) Climatic curve
manual setpoint shift in heating mode
EN
· To set the single zone or zone 1 use parameters from P101 to P161 (see table).
3.2.2 – SETTING OF SINGLE ZONE OR ZONE 1
10
Num. Description
P201 Plant type (zone 2)
Unit Floor
–
P205 Maximum climatic curve °C 35 setpoint (zone 2)
P206 Minimum climatic curve setpoint (zone 2)
°C 20
P220 Temperature for maximum °C -7 setpoint (zone 2)
P221 Temperature for minimum °C 17 setpoint (zone 2)
P223 Cooling setpoint (zone 2)
°C 23
P230 Calculated setpoint (zone 2)
°C
–
P231 Lowest cooling setpoint with 0-10V control (zone 2)
°C 23
P232 Highest cooling setpoint °C 30 with 0-10V control (zone 2)
P250 0-10V signal function (zone 2)
–
0
P251 Maximum 0-10V setpoint °C 5 shift
P252 P260 P261
Manual setpoint shift Mixing valve delay Mixing valve control type
°C 0
sec 60
–
0
Default value Fan coils Radiators
0
Range
Min. Max.
0
2
45
50
30 55
Increase
Value description
1
0 = Under oor
1 = Fan coil
2 = Low temperature radiators
0,5
35
40
20
40
0,5
Notes
When P201 is changed, P205 / P206 / P220 / P221 P223 are reset to the
corresponding default value.
Only for heating mode See graph “CLIMATIC CURVE” See graph “CLIMATIC CURVE”
-7
-7
-20 P221 0,5
17
17
P220 +35 0,5
12
–
10
30
0,5
–
–
Read only
Set to the minimum expected regional temperature See graph “CLIMATIC CURVE”
If P221 < P220, P220 is automatically set to P221 See graph “CLIMATIC CURVE”
In cooling mode the setpoint is fixed and it corresponds to P223
12
–
10 P232 0,5
Active only if P250 = 1, it corresponds to a signal of 10V. See graph “0-10V CONTROL”
30
–
P231 30
0,5
Active only if P250 = 1, it corresponds to a signal of 0V. If P232 < P231, P232 is automatically set to P231 See graph “0-10V CONTROL”
0
0
0
2
1
0 = Disabled
1 = Thermal load
2 = Setpoint command
If P250 = 3 or 4, 0-10V signal is read on outdoor unit only and signals on zone 1 and 2 will be ignored. See graph “0-10V CONTROL”
5
5
1
10
0,5
Active only in heating mode and if P250 = 1. It represents the shift on the setpoint with a signal of 10V. (See graph “0-10V CONTROL”)
0
0
0
10
0,5
Climatic curve manual setpoint shift in heating mode
60
60
30 300 5
0
0
0
1
1
0 = 230 Vac control (2 or 3 points)
1 = 0-10V control
· To set zone 2 use parameters from P201 to P261.
EN
3.2.3 – SETTING OF ZONE 2
4 – GRAPHS
4.1 – ON/OFF HYSTERESIS
HEATING OPERATION
P02
Heat pump ON
Heat pump OFF
P130 (setpoint)
Return water temperature
COOLING OPERATION
P02 Heat pump ON
Heat pump OFF
P130 (setpoint)
4.2 – OPERATING RANGE OF HEAT PUMP/BACKUP HEATING
EN
Return water temperature
Backup heating only
Heat pump +
backup heating
Heat pump only
P40
P12
– 20°C
0°C
Outdoor air temperature
NOTE The operation of the heat pump is prevented if the outside temperature is below the stop threshold (parameter 40). Only the backup heating is authorized.
4.3 – CLIMATIC CURVE (HEATING MODE)
Return water setpoint
P105
Y
P106 P120
P130 (setpoint)
X
P121
Outdoor air temperature
4.4 – ANTIFREEZE FUNCTION
P32 Atifreeze function activated
P31
Atifreeze function not activated
Outdoor air temperature
If the antifreeze function is active:
Unit in forced function for water heating
Unit in normal operation
5°C
15°C
Return water temperature (RWT)
11
EN
4.5 – 0-10V CONTROL
Return water setpoint
Thermal load (P150 = 1)
P105
Y+Z
P130 (setpoint)
Z = P151 * (0-10V)%
Y
P106
P120
X
P121
Example: P151 = 5°C 0-10V signal = 6V = 60% Z = 5°C * 60% = 3°C
Outdoor air temperature
Setpoint command (P150 = 2)
Return water setpoint
P105
Y
P106 0V
Return water setpoint
P132
Y
P131 0V
HEATING
P130 (setpoint)
X
10V
COOLING
P130 (setpoint)
X
10V
0-10V 0-10V
NOTE: The graphs referring to the parameters of zone 1 are the same for zone 2 with the corresponding parameters.
12
EN
4.6 – RETURN WATER MINIMUM TEMPERATURE PROTECTION
Heat pump disabled and activation of backup heating
2°C
Heat pump
enabled
P52
Default: 15°C
Return water temperature (RWT)
NOTE
A water temperature safety (system return) prevents the heat pump from
operating if the temperature is lower than the heating authorization threshold
with the heat pump (parameter 52). In this case, only the electric backup
heating is authorized to raise the water temperature and allow the heat pump
to operate, at any external temperature. If the backup heating is not
installed (P09 = 0) this protection is not active. For this reason, the heat
pump stops and the display will show the writing: RWT < P52
13