argo V 1221 PORTABLE AIR CONDITIONERS (LOCAL) Instruction Manual

June 4, 2024
argo

argo logo PORTABLE AIR CONDITIONER (LOCAL)

FUTUR

OPERATING INSTRUCTIONS

Read the instructions carefully before operating the appliance or carrying out maintenance work. Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or damage. Store these instructions in a safe place for future reference

Flammable Warning Icon| The appliance is filled with flammable gas R290
---|---
| Before installing and using the appliance, read the owner’s manual.
| Before installing the appliance, read the installation manual
| For any repairs you need, contact the nearest authorized Service Centre and strictly follow the manufacturer’s Service Manual

The Refrigerant R290

  • To realize the function of the air conditioner unit, a special refrigerant circulates in the system. The refrigerant is the fluoride R290 = 3 GWP (Global warming potential).  This refrigerant is flammable and odorous. It can lead to explosions under certain conditions, however, the flammability of this refrigerant is very low and it can be ignited only by fire.
  • Compared to other common refrigerants, R290 is a non-polluting refrigerant with no harm to the ozonosphere and no effect on the greenhouse effect. R290 has very good thermodynamic features which lead to really high energy efficiency. The units, therefore, need less filling

Warning:
Do not try to accelerate the defrosting process or clean the appliance in different ways other than those recommended by the manufacturer. Should repair be necessary,  contact your nearest authorized Service Centre. Any repairs carried out by unqualified personnel may be dangerous. The appliance has to be stored in a room that doesn’t have any continuously operating ignition sources. (for example open flames, an operating gas appliance, or an operating electric heater.) Do not pierce or burn.
The appliance has to be installed, used, and stored in a room with a floor area larger than 15 m2.
For repairs,  strictly follow the manufacturer’s instructions only for appliances filled with  R290  flammable gas.  Be

argo V 1221 PORTABLE AIR CONDITIONERS \(LOCAL\) -
Sambly

GENERAL OPERATING AND SAFETY INSTRUCTIONS

  • This appliance is a local air conditioner designed for domestic use.

  • Only use this air-conditioner as described in this manual.

  • Ensure that the required voltage and frequency (220-240V/50 Hz) match the available power source.

  • Fuse style T3.15AH250V, the electricity passing through the fuse cannot be above 3.15A.

  • Children shall not play with the appliance.

  • Cleaning and user maintenance shall not be made by children without supervision.

  • Ensure that the electricity system is able to deliver the operating current required by the air conditioner, in addition to that normally absorbed by other appliances  (household appliances, lighting the system, etc.). Please refer to the maximum power input data indicated on the air conditioner’s data plate.

  • Connection to the electricity grid must take place in accordance with current installation standards.

  • Ensure that the automatic switches and system protection valves are able to withstand a start-up current of 6A (normally for less than 1 second).

  • The system socket must always be fitted with an efficient earth connection.

  • Make sure that the plug is fully inserted. Do not use multiple adapters. Do not touch the plug with wet hands. Make sure that the plug is clean.

  • Do not use the plug as a means by which to start/stop the air conditioner: use the ON/OFF button on the remote control or on the control panel.

  • Do not install the air conditioner in rooms where it may receive water splashes (e.g. laundry rooms).

  • This air conditioner can be used by children of 8 years of age or older, and by persons with reduced physical, sensory and mental abilities or who lack the necessary know-how and experience to operate it, under the supervision or instruction of a person responsible for their safety, so that they are fully aware of the attendant risks.

  • Before moving or cleaning the device, ensure that it is unplugged from the socket.

  • Do not move the air conditioner while it is operating; first, turn the appliance off,  check for any condensate build-up and empty it if necessary.

  • To turn the appliance off, set the remote control to OFF and remove the plug from the socket. Pull on the lug only. Do not pull the cord.

  • Do not use the appliance if the cord or plug is damaged. If the power supply wire is damaged, it must be replaced by the manufacturer or its technical assistance service or in any case by a person with similar qualifications, in order to prevent any risk.

  • The appliance must be installed in accordance with national wiring regulations.

  • Keep the unit away from fire, possible fire sources, and inflammable or explosive objects.

  • Do not leave the unit unattended while it’s operating, turn the unit off and unplug it.

  • If a drainage hose is used, the ambient temperature must be lower than 0°C. It can cause water leakage to the air conditioner.

  • Do not splash or pour water on the air conditioner
    PRECAUTION!

  • Do not insert any objects into the air conditioner: this is very dangerous as the fan turns at high speed.

  • Ensure that air circulates freely around the unit. Do not cover the air intake and delivery grilles with drapes or any other means.

WARNING!

  • The air conditioner must be positioned at least 50 cm from the wall or any other obstacles, on a flat and stable surface so as to avoid water leaks.
  • The air conditioner is fitted with a system for protecting the compressor from overload. This means that the compressor only starts 3 minutes after its previous stoppage.
  • Please wait at least 3 minutes before starting the unit. This helps prevent the compressor from being damaged.

WARNING!
In the event of an anomaly, switch the appliance off and unplug it from the socket. Do not dismantle or attempt to repair or modify the product. In the event of a malfunction,  contact the service center directly.

WARNING!

  • Do not expose the air conditioner to direct sunlight, as the color of the materials may change; moreover, the appliance may overheat causing the protection mechanism to intervene and switch the appliance off.
  • Do not use insecticides, oils, detergents, or spray paints near the appliance; do not use aggressive chemical detergents to clean the casing: this may damage the finish and color.
  • Close all open windows to maximize air conditioning efficiency.

The manufacturer will not be held liable if safety and accident prevention rules are not observed.

DESCRIPTION OF THE APPLIANCE

argo V 1221 PORTABLE AIR CONDITIONERS \(LOCAL\) -
DESCRIPTION

  1. CONTROL PANEL AND FUNCTION BUTTONS WITHOUT REMOTE CONTROL
  2. HORIZONTAL FINS AND AIR INTAKE
  3. VERTICAL FINS AND AIR INTAKE
  4. WHEELS
  5. AIR FILTER
  6. AIR EXPULSION HOSE END FITTING| 7) AIR EXPULSION HOSE
  7. JOINT
  8. END FITTING FOR WINDOW
  9. WINDOW ACCESSORY
  10. CORD CABLE CLAMP
  11. REMOTE CONTROL
    ---|---

Min/max operating limits (internal temperature)
Cooling: 16 °C DB / 35 °C DB
Dehumidification: 16 °C DB / 35 °C DB
Cooling mode room temperature adjustment range: 16 °C DB / 30 °C DB

PRE-OPERATING CHECKS AND OPERATIONS

The following space must be maintained to ensure the operating efficiency of the portable air conditioner.

APPLIANCE START-UP

Open the packaging and remove the box from above. Remove the product and the other elements supplied (illustrated in the box below)

|
---|---
LCD remote control| Type AAA batteries for the remote control
|
Round fitting for window (1) to be positioned between the end of the tube and the  end fitting for the window (in the packing it’s the same fitting installed on porthole kit (A)| End fitting for window, supplied into two parts to be joined with 2  flaps that fit together (2)
|
Flat fitting for positioning
between the air discharge
outlet and the hose| Hose
|
Clamp| Cord winder
|
Drain hose| Screws
|
Window unit kit (3 pcs) A+B+C| Round fitting for a window unit, to be positioned between the end of the  tube and the window unit (A)
|
Window unit (B)| Cap (C )

Position the product vertically on a flat and stable surface, as close as possible to a window and at least 50 cm from the walls or other nearby obstacles.

INSTALLATION OF CORD WINDER HOOKS

Install the cord winder hooks to the back of the unit using the screws, as shown in the figure.
The hooks must be positioned facing upwards and downwards.

USE WITH END FITTING FOR WINDOW
Connect the flat fitting to the hose, extend the hose as far as necessary for reaching the outside, and connects to the back of the air conditioner.
Connect the round window fitting (1) to the end of the hose then the end fitting for the window (2), previously obtained by joining parts A and B argo V 1221 PORTABLE AIR CONDITIONERS \(LOCAL\) - joining
parts

When the appliance is not being used, wind the power cord around the hooks.
Wind the cord around the hook.
Next, slide the flat fitting downwards into the grooves (A) and secure it with the hook (B).
The upward-facing side of the flat fitting is marked “TOP”.

argo V 1221 PORTABLE AIR CONDITIONERS \(LOCAL\) - upward
facing

Open the windows and lock one of the two leaves with the handle.
Place the end fitting against the fixed leaf of the window, and draw the other leaf towards it.argo V 1221 PORTABLE AIR CONDITIONERS \(LOCAL\) - windows
and lock

USE WITH WINDOW UNIT KIT

  1. To make the hole in the glass it is advisable to take the porthole kit accessory to the glazier

  2. Insert the window unit into the window.

  3. Insert the round fitting onto the flexible pipe.argo V 1221 PORTABLE AIR CONDITIONERS \(LOCAL\) - flexible pipe

  4. Insert the round fitting into the retractable flexible pipe and insert the latter with its round fitting into the window unit without the plug.

  5. Insert the flat fitting onto the hose

  6. Slide the flat fitting downwards into the grooves (A) and secure it with the hook (B).
    The upward-facing side of the flat fitting is marked “TOP”.argo V 1221
PORTABLE AIR CONDITIONERS \(LOCAL\) - flat fitting1

  7. The outlet must be between 40 cm and 130 cm above the ground. Avoid tight curves or bends in the flexible hose.argo V 1221 PORTABLE AIR CONDITIONERS \(LOCAL\) - tight curves

  8. If the air conditioner is not used for prolonged periods, disconnect the pipe and plug the window unit.

Connect the power cord to a suitable electric socket (220–240 V). Insert the supplied batteries into the remote control and make sure the poles match. Select the desired operating mode from the remote control.

HOW TO USE THE APPLIANCE

This appliance can be used for cooling, dehumidifying, and ventilating.
When switching between modes, the fan continues to rotate but the compressor stops: the compressor will start after 3 minutes. This delay protects the compressor from potential damage.

argo V 1221 PORTABLE AIR CONDITIONERS \(LOCAL\) -
APPLIANCE

THE DISCHARGE TUBE MUST ALWAYS BE CONNECTED to the appliance: the only exception is when the appliance is used solely for dehumidification, in which case it is advisable to let the appliance discharge directly into the environment for maximum efficiency (consult the “Dehumidification Mode” paragraph). Regularly clean the air filters beneath the easily removable rear grille to keep the air conditioner working efficiently.

OPERATING MODES

COOLING MODE (COOL)

  • The first time it is turned on, the air conditioner operates in ventilation
  •  Press the MODE button to select Cool mode
  •  The “Cool” LED on the control panel will turn on.
  •  The temperature can be adjusted to between 16 °C and 30 °C.
  •  In this mode, whenever the ON/OFF button is pressed, the unit switches off, the appliance saves the temperature setting and, when switched back on again, retains this setting.
  • In this mode, the fan speed can be adjusted and the Timer and SLEEP functions can be set.
  • For more silent operation, run the fan at low speed.
  • Under cooling mode, when the set point is reached, turns off, and the internal fan motor (the upper one) keeps operation continuously at the set fan speed; the external fan  motor (the lower one) continues the operation at a low fan speed

DEHUMIDIFICATION MODE (DRY)

  • Press the MODE button to select Dry.
  • The temperature is controlled by the PCB and cannot be regulated.
  • In this mode, whenever the ON/OFF button is pressed, the unit switches off, the appliance saves the settings and, when switched back on again, retains them.
  • The fan speed is set to low and cannot be adjusted.

NOTE
The air conditioner does not cool the room when it is used as a dehumidifier.
When the appliance is used as a dehumidifier, the flexible hose must not be connected.
For maximum dehumidification efficiency, leave the rear discharge attachment- free to discharge directly into the environment.
The dehumidification mode is recommended during autumn and winter.
If used in summer, it is best to leave the flexible hose attached so that the hot air can be discharged towards the outside rather than into the room.
During dehumidification, continuous drainage should be implemented (consult the next chapter, “CONDENSATE ELIMINATION”).

VENTILATION MODE (FAN ONLY)

  • Press the MODE button to select Fan and wait until the relative icon appears.
  • In this mode, the fan speed can be adjusted.
  • The temperature cannot be adjusted.

HOW TO ELIMINATE CONDENSATE

This appliance automatically vaporizes condensate in the cooling mode.
When the air conditioner operates in cooling mode, there is no need to drain condensate continuously; only in certain weather conditions with very humid air may it occur that water deposits inside the unit. When its inner tank is full, the air conditioner beeps 8 times and the message “H8” appears on the display to signal that the tank is full and stop the appliance’s operation.

INSTALLATION OF THE DRAINAGE HOSE

  1. Remove the rubber plug at the back of the unit (1)argo V 1221 PORTABLE AIR CONDITIONERS \(LOCAL\) - DRAINAGE HOSE
  2. Mount the clamp (2) onto the back of the unit, to the right of the drainage opening (1), using a screw (3).argo V 1221 PORTABLE AIR CONDITIONERS \(LOCAL\) - drainage opening
  3. Screw the drainage hose (4) onto the drainage opening then secure it with the clip (2).

1. Insert the cap onto the other end of the drainage hose (1), secure it with the clip (2) then insert it into the clamp (5).

Cooling

When the unit operates in the cooling mode, ensure that the rubber cap closing the drainage opening on the back of the appliance is properly positioned.
To empty the container, switch the air conditioner off and unplug the cord.
Remove the cap from the rear drainage opening and place its end over a normal drain. Ensure that the tube is not twisted or bent. The tube must slope downwards. Re-close the drainage opening with the cap, insert it into the clamp and resume use of the air conditioner.

Dehumidification

WARNING!
When using the air conditioner in dehumidification mode, we recommend always ensuring continuous drainage, in order to maximize dehumidification efficiency.
Use the drainage outlet on the appliance. The water can be drained into a drain by simply connecting a tube with a 14 mm internal diameter (not supplied).

  1. Remove the cap by turning it anticlockwise then remove the plug.
  2. Screw the connection tube provided turning it clockwise.
  3. Next, insert the drainage tube into the connection tube.
  4. Avoid bends in the drainage tube

argo V 1221 PORTABLE AIR CONDITIONERS \(LOCAL\) - drainage
tube

REMOTE CONTROL OPERATION

Insert the batteries into the remote control, while respecting the indicated polarities.
Only use type AAA 1.5V batteries.
Remove the batteries if the remote control is not used for a month or longer.
Do not attempt to recharge the batteries. Replace all batteries at the same time.
Do not throw the batteries into the fire: they may explode.

INFORMATION FOR CORRECT DISPOSAL OF THE BATTERIES PURSUANT TO THE EUROPEAN DIRECTIVE
2006/66/EC and amendments Directive 56/2013/EC
Replace the batteries when depleted. At the end of their working life, batteries must be disposed of separately from unsorted waste. They must be delivered to appropriate separated waste disposal plants or to dealers that provide a similar service. Separate waste disposal of batteries prevents potential negative effects on the environment and human health resulting from inadequate disposal, and also allows the materials from which it is made to be recovered and recycled in order to achieve significant savings in terms of energy and resources. The separate disposal obligation is underlined by the crossed-out dustbin symbol appearing on the battery. Illegal disposal of the product by the user is subject to administrative penalties as per current regulations.

FOR OPTIMUM OPERATION OF THE REMOTE CONTROL, ADDRESS THE TRANSMITTER HEAD TOWARDS THE RECEIVER LOCATED ON THE AIR CONDITIONER.
To operate the remote control, press the ON / OFF button on the handset. The icon on the remote control display will flash once and you will hear a sound signal indicating that the signal has been sent to the air conditioner.
In off mode, the set temperature and set timer will be displayed on the remote control.

argo V 1221 PORTABLE AIR CONDITIONERS \(LOCAL\) - Signal
receiver

  1. ON/ OFF BUTTON
  2. MODE BUTTON
  3. TEMPERATURE AND TIMER ADJUSTMENT BUTTONS
  4. FAN BUTTON – VENTILATION SPEED
  5. SWING BUTTON
  6. SLEEP BUTTON (only on the remote control)
  7. TIMER BUTTON

argo V 1221 PORTABLE AIR CONDITIONERS \(LOCAL\) - REMOTE
CONTROL1

A. Cooling
B. Dehumidification
C. Ventilation
D. Temperature setting
E. Timer setting
F. Speed setting| G. Lock
H. Sleep mode setting
I. Swing on/off
L. Signal transmission
N. T-OFF off timer
M. T-ON on a timer
---|---

argo V 1221 PORTABLE AIR CONDITIONERS \(LOCAL\) - Signal receiver
1

( 1) ON/OFF BUTTON
Press this button to switch the unit on or off.
When switched on, the appliance will start functioning based on its last settings (save function).

(2) MODE SELECTION BUTTON (MODE)
Press this button to select the various operating modes, according to the following sequence:

In the COOL mode, the display lights up. In the DRY and FAN modes, the display does not light up.
(3) TEMPERATURE + – AND TIMER ADJUSTMENT BUTTONS
The temperature can be adjusted to between 16 °C and 30 °C.
Increase temperature (+):

  1. Allows for adjusting the desired temperature in cooling (COOL) mode.
  2. Whenever the(+) button is pressed, the set temperature increases by 1 °C.
    Decrease temperature (- ):
  3. Allows for adjusting the desired temperature in cooling (COOL) mode.
  4. Whenever the ( – ) button is pressed, the set temperature decreases by 1 °C.
    The same button allows for setting the TIMER.

(4) FAN SPEED ADJUSTMENT BUTTON
Press this button when the appliance is switched on for adjusting the ventilation speed in cooling mode (AUTO), to low (Low), medium (Med), or high (High).

The fan speed cannot be adjusted in DRY mode and is fixed to low speed.
(5) SWING BUTTON: Press this button, and the horizontal louver of the air conditioner will swing up&down automatically at the maximum angle.
(6) SLEEP BUTTON (only on the remote control)
Press this button to activate the Sleep function, which automatically adapts the temperature to changes in body and room temperature throughout the night, so as to optimize comfort when sleeping and minimize consumption.
In cooling mode, the temperature increases by 1 °C in an hour then by 2 °C in two hours, and remains in this setting for the whole period. The Sleep function is not available in the ventilation, dehumidification, and auto modes. The indicator light turns on the display of the remote control whenever the Sleep function is set.

(6) TIMER BUTTON (on both the remote control and portable unit) Press and hold this button for 1 second to set the timer.
1)Timer-on (automatic switch-on)
When the appliance is off, this button is used to set a delay after which the unit will switch on.
Remote control: Press TIMER. The T-ON and H icons will light up on the remote control. Press the + and – buttons within 5 seconds to set the delay. The T-ON icon will remain on to indicate that the TIMER has been set.
Portable unit: Press TIMER. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm.

2)Timer-off (automatic switch-off)
When the appliance is running in COOL mode, set a delay after which the unit will switch off.
Remote control: Press TIMER. The T-OFF and H icons will light up. Press the + and – buttons within 5 seconds to set the delay. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm. The T-OFF icon will remain lit to indicate that the switch-off TIMER is running.
Portable unit: Press TIMER. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm.
Resetting the timer: If a TIMER has been set, press TIMER to display the delay. Press TIMER again to cancel the setting.

(8) TEMPERATURE AND ERROR DISPLAY

Problem Cause Solution
H8 Tank full of water. Empty the tank.

If the problem persists, contact a service center.
F1| Room temperature sensor failure.| Contact a service center.
F2| Failure of temperature sensor on the evaporator.| Contact a service center.
F0| Refrigerant leakage. The air conditioner is out of order.| Contact a service center.
H3| Overload protection device on the compressor.| The room temperature exceeds the appliance’s operating range (beyond 35°) or there is too much humidity. Wait for the temperature to drop below 35 °C.

Check if the evaporator and compressor are obstructed by objects. If they are, remove the objects, disconnect the unit then restore the power supply.
Clear the obstructed ventilation grilles. If the problem persists, contact a service center.

E8| Overload protection.
F4| The external temperature sensor has short-circuited.| Contact the service center.

The temperature and error display lights up only in the COOL mode. In the DRY and FAN modes, the display does not light up.

SAFETY FUNCTIONS

REMOTE CONTROL LOCK
Simultaneously press “+” and “-” to lock the remote control.
The “Lock” icon will light up on the remote control, and the latter will not respond to commands.
SWITCHING BETWEEN °C AND °F.
Press the “-” and “MODE” buttons simultaneously to switch between °C and °F.
LIGHT FUNCTION
Press the “+” and “FAN” buttons simultaneously for 3 seconds to set the activation/ deactivation of the lamp.

CARE AND MAINTENANCE

WARNING!
Prior to carrying out any cleaning or maintenance, unplug the unit from the power socket.

  1. Cleaning the air filters
    The air filter must be checked at least once every two weeks of operation. Operating with dirty or clogged filters will decrease the effectiveness of the air conditioner and can cause serious problems. To remove the filter, release the rear grille then slide out the filter by gently pulling it sideways. argo V 1221 PORTABLE AIR CONDITIONERS \(LOCAL\) - air
filtersUse a vacuum cleaner to remove any dust. Should this not be sufficient, wash the filter with lukewarm water and neutral detergent (if necessary), rinse it with cold water then leave it to dry naturally before putting it back in place. After putting the filter back in place, close the grille, and resume use of the air conditioner.

  2.   Cleaning the casing.
    Use a soft damp cloth to clean the outer surface of the air conditioner.
    Do not use excessively hot water, solvents, petrol or other aggressive chemical compounds, talcum powder, and brushes: they may damage the surface or color of the casing.
    Remove any stains using warm water with a little neutral detergent.
    Do not pour water onto the air conditioner to clean it: this may damage the internal components or cause a short circuit.

  3. Storage.
    When you do not envisage using the air conditioner for a long time, clean the filters before storing them away. Keep the appliance in a vertical position at all times. Do not  place any heavy objects on the top and, if possible, protect the air conditioner with a plastic sheet.

  4. Transport.
    Preferably keep the air conditioner in the vertical position when transporting it.
    Should this not be possible, rest it on its right-hand side; when it reaches its destination, immediately put the appliance in the vertical position and wait at least 4 hours before using it in the cooling mode.

  5. For complete safety, regularly check the condition of the power cord; should it be damaged through use, contact the Service Centre to replace it.

TIPS FOR MAXIMISING COMFORT AND MINIMISING CONSUMPTION

CHECK that

  • the unit’s extraction and delivery grilles are always unobstructed;
  • the air filters are always clean: a dirty filter will decrease the passage of air and thus reduce the unit performance;
  • the doors and windows are closed, to avoid infiltration of unconditioned air;
  • the flexible hose is correctly positioned, without folds or sharp bends;
  • the room temperature is above 18 ºC for the cooling mode, and above 10 ºC for the dehumidification mode.

REGULATION (EU) No. 517/2014 – F-GAS
The unit contains R290, a natural greenhouse gas with global warming potential (GWP) = 3 – Kg. 0,18 = 0,00054
Tons CO2 Equiv.
Do not release R290 into the atmosphere.

INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH THE EUROPEAN DIRECTIVE 2012/19/EU
This appliance may not be scrapped with domestic waste at the end of its life cycle. We call your attention to the crucial role played by the consumer in the re-use, recycling, and other forms of recovery of such waste.
The appliance must be scrapped by a sorted waste disposal center or by returning it to the retailer (no charge is levied for this service), when you purchase a new equivalent appliance.
Sorted disposal of electric and electronic equipment prevents the negative effects on the environment and human health resulting from improper scrapping, and also allows the materials from which it is made to be recovered and recycled, with significant savings in terms of energy and resources.
The sorted disposal requirement is indicated by the crossed waste bin label affixed to the appliance.

Specialist’s Manual
Aptitude requirement for maintenance man (repairs. should be done only by specialists).
a) Any person who is involved with working on or breaking into a refrigerant circuit should hold a currently valid certificate from an industry-accredited assessment authority,  which authorizes their competence to handle refrigerants safely in accordance with an industry-recognized assessment specifìcation.
b) Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of a person competent in the use of flammable refrigerants.
Safety preparation work
The maximum refrigerant charge amount is shown in the following table (Note: Please refer to the nameplate for the charging quantity of R290)

Room area (m2) 4 11 15
Maximum charge (kg) <0.152 0.225 0.304

table a – Maximum charge (kg)

Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

  • Work procedure
    Work shall be undertaken under a controlled procedure so as to minimize the risk of flammable gas or vapor being present while the work is being performed.

  • General work area
    AII maintenance staff and others working in the local area shall be instructed on the nature of the work being carried out.
    Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.

  • Checking for the presence of refrigerant
    The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially toxic or flammable atmospheres.  Ensure that the leak detection equipment being used is suitable for use with all applicable refrigerants, i.e. non-sparking, adequately sealed, or intrinsically safe.

  • The presence of a fire extinguisher
    if any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

  • No ignition sources
    No person carrying out work in relation to a refrigeration system that involves exposing any pipe work shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. AII possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removal, and disposal, during which refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.

  • Ventilated area
    Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting
    any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation
    should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

  • Checks to the refrigeration equipment
    Where electrical components are being changed, they shall be fit for the purpose and the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt, consult the manufacturer’s technical department for assistance.
    The following checks shall be applied to installations using flammable refrigerants:
    —The actual refrigerant charge is in accordance with the room size within which the refrigerant-containing parts are installed;
    —The ventilation machinery and outlets are operating adequately and are not obstructed;
    —lf an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
    —Marking of the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
    —Refrigeration pipes or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant- containing components unless the components are constructed of materials that are inherently resistant to being corroded or are suitably protected against being so corroded.

  • Checks to electrical devices
    Repair and maintenance of electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise the safety,  then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
    Initial safety checks shall include:
    —That capacitor is discharged: this shall be done in a safe manner to avoid the possibility of sparking;
    —That no live electrical components and wiring are exposed while charging, recovering, or purging the system;
    —That there is continuity of earth bonding.

  • Repairs to sealed components
    During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. if it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
    Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, an excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.

  • Ensure that the apparatus is mounted securely.

  • Ensure that seals or sealing materials have not degraded to the point that they no longer serve the purpose of preventing the ingress of flammable atmospheres.  Replacement parts shall be in accordance with the manufacturer’s specifications.
    NOTE: The use of silicon sealant can inhibit the effectiveness of some types of leak detection equipment. intrinsically safe components do not have to be isolated prior to working on them.
    Repair to intrinsically safe components
    Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed
    the permissible voltage and currently permitted for the equipment in use.
    intrinsically safe components are the only types that can be worked on while living in the presence of a flammable atmosphere. The test apparatus shall beat the correct rating.
    Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak

Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges, or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.
Leak detection methods
The following leak detection methods are deemed acceptable for all refrigerant systems.
Electronic leak detectors may be used to detect refrigerant leaks but, in the case of flammable refrigerants, the sensitivity may not be adequate, or may need re-calibration.
(Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used.
Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed, and the appropriate percentage of gas (25 % maximum) is confirmed.
Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/extinguished.
If leakage of refrigerant is found which requires brazing, all of the refrigerants shall be recovered from the system, or isolated (by means of shut-off valves) in a part of the system remote from the leak. For appliances containing flammable refrigerants, oxygen-free nitrogen (OFN) shall then be purged through the system both before and during
the brazing process.
Removal and evacuation

When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used. However, for flammable refrigerants, it is important that best practice is followed since flammability is a consideration. The following procedure shall be adhered to:

  • remove refrigerant;
  • purge the circuit with inert gas; evacuate;
  • purge again with inert gas;
  • open the circuit by cutting or brazing.

The refrigerant charge shall be recovered into the correct recovery cylinders.
For appliances containing flammable refrigerants, the system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times.  compressed air or oxygen shall not be used for purging refrigerant systems.
For appliances containing flammable refrigerants, flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to the atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipe-work are to take place.
Ensure that the outlet for the vacuum pump is not close to any ignition sources and that ventilation is available.

Charging procedures
In addition to conventional charging procedures, the following requirements shall be followed.
– Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
– Cylinders shall be kept upright.
– Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
– Label the system when charging is complete (if not already).
– Extreme care shall be taken not to overfill the refrigeration system.
Prior to recharging the system, it shall be pressure-tested with the appropriate purging gas.
The system shall be leak-tested on completion of charging but prior to commissioning. A follow-up leak test shall be carried out prior to leaving the site.
Decommissioning
Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. it is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. it is essential that electrical power is available before the task is commenced.
a. Become familiar with the equipment and its operation.
b. Isolate system electrically.
c. Before attempting the procedure, ensure that:
• mechanical handling equipment is available, if required, for handling refrigerant cylinders;
• all personal protective equipment is available and being used correctly;
• the recovery process is supervised at all times by a competent person;
• recovery equipment and cylinders conform to the appropriate standards.
d. Pump down the refrigerant system, if possible.
e. If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system
f. Make sure that the cylinder is situated on the scales before recovery takes place.
g. Start the recovery machine and operate in accordance with the manufacturer’s instructions
h. Do not overfill cylinders. (No more than 80 % volume liquid charge).
i. Do not exceed the maximum working pressure of the cylinder, even temporarily.
j. When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from the site promptly and all isolation valves on the equipment are closed off.
k. Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked
Labeling
Equipment shall be labeled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. For appliances containing flammable refrigerants, ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.
Recovery
When removing refrigerants from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed.
Ensure that the correct number of cylinders for holding the total system charge is available. AII cylinders to be used are designated for the recovered refrigerant and labeled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with a pressure-relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of all appropriate refrigerants including, when applicable, flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained, and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult the manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant waste transfer note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
LF compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.

argo logoimprove your life
www.argoclima.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

argo User Manuals

Related Manuals