Waykar A019E-8K 9,000 BTU Portable Air Conditioner User Manual
- June 13, 2024
- waykar
Table of Contents
- FOR CUSTOMERS
- REQUESTING CUSTOMER SERVICE
- BEFORE FIRST USE:
- Important Safety Instructions
- Explanation of Symbol displayed on the unit
- Features and Components
- Control Setting
- Protection function
- Installation and adjustment
- Drainage Instructions
- Troubleshooting
- Technical Parameter
- Special Notes
- Warranty & Contactus
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Portable Air Conditioner
Please read this manual carefully before using the product
USER MANUAL
FOR CUSTOMERS
Thank you for purchasing our portable air conditioner.
Waykar has been committed to developing powerful and easy-to-use products to
bring more convenience to your life. We highly recommend you to keep this user
manual for future reference in case of unexpected problems.
Please read this user manual carefully to ensure proper use the portable air
conditioner. This portable air conditioner 1s perfect for adjusting the
temperature in bedrooms, basements, offices, storages and so on.
Waykar portable air conditioner adjust the temperature efficiently, creating a
more healthy and comfortable environment for you and your family.
REQUESTING CUSTOMER SERVICE
If there are any problems of the product, please contact Waykar Customer Service at support@waykar.com with your Purchase Order ID. We’ll help you solve the problems as soon as possible.
BEFORE FIRST USE:
To protect the product from any internal damages, please keep the product in
the upright position throughout its journey.
Please take out the product and leave it standing in the upright position for
24 HOURS before plugging it in.
Important Safety Instructions
1. General Safety Instructions
- The air conditioner is only suitable for indoor and 1s not suitable for other applications.
- Follow local grid interconnection rules while installing the air conditioner and ensure that it is properly grounded. If you have any question on electrical installation, follow the instructions of the manufacturer, and if necessary, ask a professional electrician to install it.
- Place the machine in a flat and dry place and keep a distance of above 50cm between the machine and the surrounding objects or walls.
- After the air conditioner is installed, ensure that the power plug 1s intact and firmly plugged into the power outlet, and place the power cord orderly to prevent someone from being tripped or pulling out the plug.
- Do not put any object into the air inlet and outlet of the air conditioner. Keep the air inlet and outlet free from obstructions.
- When installing the drainage pipes, make sure that the drainage pipes are connected correctly and that they are not deformed or bent.
- While adjusting the upper and lower wind-guide strips of the air outlet, pluck it with hands gently to avoid damaging wind-guide strips.
- When moving the machine, make sure that it 1s in an upright position.
- The machine should stay away from gasoline, flammable gas, stoves and other heat sources.
- Don’t disassemble, overhaul and modify the machine arbitrarily, otherwise it will cause a machine malfunction or even bring harm to persons and properties. To avoid danger, if a machine failure occurs, ask the manufacturers or professionals to repair it.
- Do not install and use the air conditioner in the bathroom or other humid environments.
- Do not pull the plug to turn off the machine.
- Do not place cups or other objects on the body to prevent water or other liquids from spilling into the air conditioner.
- Do not use insecticide sprays or other flammable substances near the air conditioner.
- Do not wipe or wash the air conditioner with chemical solvents such as gasoline and alcohol. When you need to clean the air conditioner, you must turn off the power supply, and clean it with a half-wet soft cloth. If the machine is really dirty, scrub with a mild detergent.
- The appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and maintenance shall not be made by children without supervision.
- If the supply cord is damaged,it must be replaced by the manufacturers,its service agents or similarly qualified persons 1n order to avoid a hazard.
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- The appliance shall be installed in accordance with national wiring regulations.
- Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
2. Special Safety Instructions for Using Flammable Refrigerant
-
Transport of equipment containing flammable refrigerants
Compliance with the transport regulations -
Marking of equipment using signs
Compliance with local regulations -
Disposal of equipment using flammable refrigerants
Compliance with national regulations -
Storage of equipment/appliances
The storage of equipment should be 1n accordance with the manufacturer’s instructions. -
Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
6.Information on servicing
6.1 Checks to the area
- Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised.
- For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
6.2 Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the
risk of a flammable gas or vapour being present while the work is being
performed.
6.3 General work area
- All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Avoid working in enclosed compartments.
- The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
6-4 Checking for presence of refrigerant
- Before and during work, the area should be inspected by suitable refrigerant detectors to ensure that technicians are aware of potential flammable environments.
- Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, 1.e. non-sparking, adequately sealed or intrinsically safe.
6-5 Presence of fire extinguisher
- If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand.
- Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
6-6 No ignition sources
- No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion.
- All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space.
- Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.
6-7 Ventilated area
- Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work.
- A degree of ventilation shall continue during the period that the work is carried out.
- The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
6-8 Checks to the refrigeration equipment
- Where electrical components are being changed, they shall be fit for the purpose and to the correct specification.
- Manufacturer’s maintenance and service guidelines should be followed at all times. If in doubt, ask the manufacturer’s technical department for assistance.
- The following checks shall be applied to installations using flammable refrigerants:
— The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
— The ventilation machinery and outlets are operating adequately and are not obstructed;
— If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
– Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
– Refrigeration pipes or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components,unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.
6-9 Checks to electrical devices
- Repair and maintenance of the electrical components shall include initial safety checks and component inspection procedures.
- If there is a fault that could compromise safety, power should not be connected to the circuit until it has been satisfactorily addressed.
- If the fault cannot be corrected immediately but it is necessary to continue to operate, an adequate temporary solution shall be used.
- This shall be reported to the owner of the equipment so all parties are advised.
- Initial safety checks shall include:
– That capacitors are discharged: this shall be done in a safe manner to avoid sparking;
– That there no live electrical components and wiring are exposed while charging, recovering or purging the system;
– That there is continuity of earth bonding.
7. Repairs to sealed components
- During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc.
- If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
- Particular attention shall be paid to the following to ensure that by working on electrical components, the casing 1s not altered in such a way that the level of protection is affected.
- This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.
- Ensure that the apparatus is mounted securely.
- Ensure that the seals or sealing materials have not degraded such that they serve the purpose of preventing the ingress of flammable atmospheres.
- Replacement parts shall be in accordance with the manufacturer’s specifications.
NOTE:
The use of silicon sealant may inhibit the effectiveness of some types of
leak detection equipment. [ntrinsically safe components do not have to be
isolated prior to working on them.
8. Repair to intrinsically safe components
- Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in using.
- Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating.
- Replace components only with parts specified by the manufacturer.
- Other parts may result in the ignition of refrigerant in the atmosphere from a leak.
9. Cabling
- Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration,sharp edges or any other adverse environmental effects.
- The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
10. Detection of flammable refrigerants
- Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks.
- A halide torch (or any other detector using a naked flame) shall not be used.
11. Leak detection methods
- The following leak detection methods are deemed acceptable for systems containing flammable refrigerants:
—Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.)
—Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used.
—Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed.
— Leak detection fluids are suitable for using with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work.
— Ifa leak is suspected, all naked flames shall be removed/ extinguished.
— Ifa leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak.
— Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.
12. Removal and evacuation
-
When breaking into the refrigerant circuit to make repairs or for any other purpose, the conventional procedures shall be used. However, for flammable refrigerants it is important that the best practice is followed since flammability is a consideration.
Opening of the refrigeration systems shall not be done by brazing. -
The following procedure shall be adhered to:
— Remove refrigerant;
— Purge the circuit with inert gas;
— Evacuate;
— Purge again with inert gas;
— Open the circuit by cutting or brazing. -
The refrigerant charge shall be recovered into the correct recovery cylinders.
-
The system shall be “flushed” with OFN to render the unit safe.
-
This process may need to be repeated several times.
-
Compressed air or oxygen shall not be used for this task.
-
Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum.
-
This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place.
-
This operation is absolutely vital if brazing operations on the pipe-work are to take place.
-
Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
13. Charging procedures
-
In addition to conventional charging procedures, the following requirements shall be followed:
— Ensure that contamination of different refrigerants does not occur when using charging equipment.
— Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them.
— Cylinders shall be kept upright.
— Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
— Label the system when charging is complete (if not already).
— Extreme care shall be taken not to overfill the refrigeration system. -
Prior to recharging the system it shall be pressure tested with OFN.
-
The system shall be leak tested on completion of charging but prior to commissioning.
-
A follow up leak test shall be carried out prior to leaving the site.
14. Decommissioning
- Before carrying out this procedure, it 1s essential that the technician is completely familiar with the equipment and all its detail.
- It is recommended good practice that all refrigerants are recovered safely.
- Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.
a) Become familiar with the equipment and its operation.
b) Isolate system electrically.
c) Before attempting the procedure ensure that:
— Mechanical handling equipment is available, if required, for handling
refrigerant cylinders;
— All personal protective equipment is available and used correctly;
— The recovery process 1s supervised at all times by a competent person;
— Recovery equipment and cylinders conform to the appropriate standards.
d) Pump down refrigerant system, if possible.
e) Ifa vacuum 1s not possible, make a manifold so that refrigerant can be
removed from various parts of the system.
f ) Make sure that cylinder is situated on the scales before recovery takes
place.
g) Start the recovery machine and operate in accordance with manufacturer’s
instructions.
h) Do not overfill cylinders (No more than 80 % volume liquid charge).
I) Do not exceed the maximum working pressure of the cylinder, even
temporarily.
j ) When the cylinders have been filled correctly and the process completed,
make sure that the cylinders and the equipment are removed from site promptly
and all isolation valves on the equipment are closed off.
k) Recovered refrigerant shall not be charged into another refrigeration
system unless it has been cleaned and checked.
15. Labelling
- Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant.
- The label shall be dated and signed.
- Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.
16. Recovery
- When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.
- When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed.
- Ensure that the correct number of cylinders for holding the total system charge is available.
- All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (1.e. special cylinders for the recovery of refrigerant).
- Cylinders shall be completed with pressure relief valve and associated shut-off valves in good working order.
- Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
- The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants.
- In addition, a set of calibrated weighing scales shall be available and in good working order.
- Hoses shall be completed with leak-free disconnect couplings and in good condition.
- Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release.
- Consult manufacturer if in doubt.
- The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged.
- Do not mix refrigerants in recovery units and especially not in cylinders.
- If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant.
- The evacuation process shall be carried out prior to returning the compressor to the suppliers.
- Only electric heating to the compressor body shall be employed to accelerate this process.
- When oil is drained from a system, it shall be carried out safely.
- This appliance 1s not intended for using by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
- When moving or relocating the air conditioner,consult experienced service technicians for disconnection and reinstallation of the unit.
- Do not place any other electrical products or household belongings under the unit.Condensation dripping from the unit might get them wet,and may cause damage or malfunction of your property.
- To keep ventilation openings clear of obstruction.
- The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
- The appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance )and ignition sources(for example operating electric heater).
- Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification.
- Servicing shall only be performed as recommended by the equipment manufacturer.
- Maintenance and repair requiring the assistance of other skilled personnel shall be carried out by the person competent in the use of flammable refrigerants.
- The pipe-work shall be complianced with national gas regulations.
- The maximum refrigerant charge amount is 0.45kg.
- The installation of pipe-work shall be kept to minimum.
- If the refrigerant is flammable the portable air conditioner equipment shall have red, Pantone® Matching System (PMS) #185 marked service ports, pipes, hoses, and other devices through which the refrigerant is serviced. This colour shall be present at all service ports and where service puncturing or otherwise creating an opening from the refrigerant circuit to the atmosphere might be expected (e.g., process tubes). The colour mark shall extend at least 25 mm (1 inch) from the refrigerant servicing point and shall be replaced if removed.
Caution, risk of fire
WARNING
- Do not use means to accelerate the defrosting process or to clean than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Do not pierce or burn the machine.
- Be aware that refrigerants may not contain an odour.
Explanation of Symbol displayed on the unit
Caution, risk of fire| WARNING| This symbol shows that this appliance
uses a flammable refrigerant.
If the flammable refrigerant is leaked and exposed to an external ignition
source,there is arisk of fire.
---|---|---
| CAUTION| This symbol shows that the operation manual should be read
carefully.
| CAUTION| This symbol shows that a service personnel should be
handling this equipment with reference to the installation manual.
**| CAUTION**| This symbol shows that information 1s available such as
the operating manual or installation manual.
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and
Interruption) power cord that is required by UL. This power supply cord
contains state-of-the-art electronics that sense leakage current. If the cord
is damaged and leakage occurs, power will be disconnected from the unit.
The test and reset buttons on the LCDI Plug are used to check if the plug is
functioning properly.
ATTENTION: Test LCDI before each use.
To test the plug:
- Plug power cord into a grounded 3 prong outlet.
- Press RESET (on some units a green light will turn on).
- Press the TEST button, the circuit should trip and cut all power to the air conditioner(on some units green light may turn off).
- Press the RESET button for using. You will hear a click and the A/C 1s ready for using.
- The power supply cord must be replaced if it fails to trip when the TEST button is pressed and the unit fails to reset.
NOTES:
- Do not use this device to turn the unit on or off.
- Always make sure the reset button is pushed in for correct operation.
WARNING:
- The power supply cord must be replaced if it fails to reset when either the test button is pushed, or it cannot be reset.
- If power supply cord is damaged, it cannot be repaired. It must be replaced by one obtained from the product manufacturer.
WARNING — RISK OF FIRE
It is important the plug fits tightly into the wall outlet.
If the plug does not fit securely and appears loose, it should not be used.
Have a licensed electrician replace the receptacle.
Features and Components
Features
- Brand new appearance, compact structure, smooth line, simple and generous shape.
- Functions of refrigeration, dehumidification, air supply and continuous drainage
- Outdoor interface is set high to facility assembly and keep the smooth flow of the heat pipe.
- Beautiful and fashionable LED display control panel.
- Air filtration capability.
- Timing switch function.
- Protection function of automatically restarting the compressor after three minutes, a variety of other protection functions.
- Temperature operation range: 7-35°C.
Components
- Adjustable slide bar
- Slide bai connector
- Exhaust hose
- Exhaust pipe joint
- Drain pipe
Assemble the connector:
Insert the window slider connector into the hole and push the connector left to fix it onto the kit. Then lock the connector by supplied screw.
Control Setting
Operation Interface
- Power Key
- Mode Selection Key Fan
- Sleep Key
- DownKey
- UpKey
- Fan Speed Selection Key
- Timer Key LED Display
When the machine is powered on for the first time, the buzzer will play power
sound, and then the machine will get into standby status.
Power Key:
Press the key to turn on and turn off the machine. In the case of power on,
press the key to turn off the machine; in the case of power off, press the key
to turn on the machine.
Mode Selection Key:
In the case of power on, press the key to switch between cooling — fan —
dehumidifying mode.
Sleep Mode:
In the cooling Mode,Press Sleep Key to turn on the sleep mode,then the unit
will work on Energy-Saving and quiet type.
Up Key and Down Key:
Press the two keys to change the setting temperature or setting time, operate
as follows:
While setting temperature, press up key or down key to select the required
temperature (not available in fan or dehumidifying mode).
While setting time, press up key or down key to select the required time.
Wind Speed Selection Key:
- In cooling and fan mode, press the key to select high,low wind speed operation. But limited by anti-cold conditions, under certain conditions, it may not run according to the set wind speed.
- In dehumidifying mode, pressing the key is invalid, and the fan will forcibly choose low wind speed operation.
Timing Key:
In the case of power on, press the key to close timing; in the case of power
off, press the key to open timing.
Press the key, when the timing symbol flashes, press UP and DOWN key to select
the required timing value.
Timing values can be set in 1-24 hours and the timing value is adjusted up or
down by one hour.
Protection function
-
Frost Protection Function:
In cooling, dehumidifying or economic power saving mode, if the temperature of the exhaust pipe is too low, the machine will automatically enter protection status; if the temperature of the exhaust pipe rises to a certain temperature, it can automatically revert to normal operation. -
Overflow Protection Function:
When water in the water pan exceeds the warning level, the machine will automatically sound an alarm, and the “FULL” indicator light will flash. At this point, you need to move the drainage pipe connecting the machine or the water outlet to sewer or other drainage area to empty the water (details see Drainage Instructions at the end of this chapter). After the water is emptied, the machine will automatically return to the original state. -
Automatic Defrosting (only in heating model):
The machine has automatic defrosting function.Defrosting can be achieved through four – way valve reversing. -
Protection Function of the Compressor
To increase the service life of the compressor, it has a 3-minute delay booting protection function after the compressor is turned off.
Installation and adjustment
Installation
Warning:
Before using the portable air conditioner, keep it upright for at least two
hours.
The air conditioner can be easily moved in the room. In the moving process,
ensure that the air conditioner is in the upright position and should be
placed on a flat surface. Do not install and use in the bathroom or other
humid environments.
- Install the heat pipe assembly (as shown in Fig.1) 1) Take out the outer connector assembly and the exhaust pipe assembly, and remove the plastic bags.
- Insert the heat pipe assembly (the end of the exhaust joint) into the back panel vent slot (push to the left) and complete the assembly (as shown in figure 1).
- Installation of window sealing plate components
- Half open the window, and mount the window sealing plate assembly to the window (as shown in Fig.2 and Fig.3).Components can be placed in horizontal and vertical direction.
- Pull various components of the window sealing plate assembly open, adjust their opening distance to bring both ends of the assembly into contact with the window frame, and fix various components of the assembly.1.2 Install the window sealing plate assembly.
- Install the body
- Move the machine with installed heat pipe and fittings before the window, and the distance between the body and walls or other objects shall be least 50 cm (as shown in Fig.4).
- Elongate the exhaust pipe and snap the flat end of the exhaust pipe joints into the hole of the window sealing plate assembly (as shown in Fig.5 and Fig.6).
Notes:
- The flat end of the exhaust pipe joints must be snapped into place.
- The pipe cannot be distorted nor has substantial turning(greater than 3).Keep the ventilation of the exhaust pipe not blocked.
Important Notice:
The length of the exhaust hose shall be 280~1,500mm, and this length is based
on the specifications of the air conditioner .Do not use extension tubes or
replace it with other different hoses, or this may cause a malfunction.
Exhaust host must be not blocked; otherwise it may cause overheating.
Drainage Instructions
This machine has two drainage methods: manual drainage and continuous drainage.
-
Manual drainage:
1)When the machine stops after the water is full, turn off the machine power and unplug the power plug.
Notes: Please move the machine carefully to avoid overflow of water from the bottom tray inside the body.
2)Place the water container under the water outlet at the back of the body.
3)Unscrew the drainage cover and unplug the water plug, the water will automatically flow into the water container.
Notes:
1)Keep the drainage cover and the water plug properly.
2)During drainage, the body can be tilted slightly backwards.
3)If the water container cannot hold all the water, before the water container 1s full, stuff the water outlet with the water plug as soon as possible to prevent water from flowing to the floor or the carpet.
4)When the water is discharged, stuff the water plug, and tighten the drainage cover. -
Continuous drainage (Optional) (only applicable to dehumidifying mode) as shown in figure:
- Unscrew the drainage cover and unplug the water plug.
- Set the drainage pipe into the water outlet.
- Connect the drainage pipe to the bucket.
Maintenance & Unit Storage
Maintenance
Cleaning: Before cleaning and maintenance, turn off the machine and
unplug the plug.
-
Clean the surface
Clean with surface of machine with a wet soft cloth. Don t use chemicals,such as benzene,alcohol,gasoline,etc,otherwise,the surface of the air conditioner will be damaged or even the whole machine will be damaged. -
Clean the filter screen
If the filter screen is clogged with dust, and the effectiveness of the air conditioner is reduced, be sure to clean the filter screen once every two weeks. -
Clean the upper filter screen
- Unscrew one screw fixed by EVA filter net and back shell with screwdriver,and take out EVA filter net.
- Put the EVA filter screen into warm water with neutral detergent(about 40°C /104°F )and dry it in the shade after rinsing clean.
Unit Storage
- Unscrew the drainage cover, unplug the water plug, and discharge the water from the water pan to other water containers or directly tilt the body to discharge the water into other containers.
- Turn on the machine, adjust it to low-wind ventilation mode, and maintain this state until the drainage pipe becomes dry, so as to keep the inside of the body ina dry state and prevent it from mildewing.
- Turn off the machine, unplug the power plug, and wrap the power cord around the wrapping post; install the water plug and the drainage cover.
- Remove the exhaust pipe and keep it properly.
- Cover the air conditioner with a plastic bag. Put the air conditioner in a dry place, keep it out of the reach of children, and take dust control measures.
Note:Ensure that the body 1s placed 1n a dry place and Keep all machine components properly.
Troubleshooting
Do not repair or disassemble the air conditioning by yourself. Unqualified repair will lead to failure of the warranty card, and may cause damage to users or their properties.
Problems | Reasons | Solutions |
---|
The air conditioner
does not work| There is no electricity.| Tum it on after connecting it to a
socket with electricity.
The overflow indicator displays “FL”.| Discharge the water inside.
The ambient temperature is too low or too high.| Recommend to use the machine
in at the temperature of 7-35°C (44-95° F).
In cooling mode, the room
temperature is lower than the set temperature; in heating mode, the room
temperature is higher than the set temperature.| Change the set temperature.
In dehumidification mode, the ambient temperature is low.| The machine is
placed in a room with an ambient temperature of greater than 17 °C (62 ° F).
The cooling effect is not good| There is direct sunlight.| Pull the Curtain.
Doors or windows are open; there arc a lot of people; or in cooling mode,
there are other sources of heat.| Close doors and windows, and add new air
conditioner.
The filter screen is dirty.| Clean or replace the filter screen.
The air inlet or outlet is blocked.| Clear obstructions.
Big noise| The air conditioner is not placed on a flat surface.| Put the air
conditioner on a flat and hard place (to reduce noise).
Compressor does not v. o r k| Overheat protection starts.| Wait for 3 minutes
until the
temperature is lowered, and then restart the machine.
---|---|---
Displays “El”| The room temperature sensor is abnormal.| Check the room
temperature sensor and related circuitry.
Displays “Er| The pipe temperature sensor is abnormal.| Check the pipe
temperature sensor and related circuitry.
Note: If problems not listed in the table occur or recommended solutions do not work, please contact the professional service organization.
Technical Parameter
Schematic diagram for air conditioner
The specific technical parameters of the machine shall be subject to the
nameplate on the product.![Waykar A019E-8K 9,000 BTU Portable Air Conditioner
- assembly 7](https://manuals.plus/wp-content/uploads/2023/10/Waykar-A019E-
8K-9000-BTU-Portable-Air-Conditioner-assembly-7.jpg) Treatment: Don’t put
the abandoned machine with other unsorted waste together. Such waste shall be
placed separately for other special use.
Fuse parameters of the machine
Type: 5TE or 5ET or 5H or 5H-Serie(s) or 5N or 524 or 50CT
Voltage: 250V
Current: 3.15A
Model | A019E-8K |
---|---|
Power Supply | 115V∼ 60Hz,1PH |
Cooling Capacity(*) | 9000 Btu/h |
Total Input Current(Cooling) | 8.8A |
SACCO | 6000 Btu/h |
CEER(^) | 6.6 |
Max. Operating Pressure(High side) | 3.72 Mpa (540psig) |
Max. Operating Pressure(Low side) | 2.07 Mpa (300psig) |
Maximum Allowable Pressure | 4.00 Mpa (580psig) |
Refrigerant/Charge | R32,270g (9.52oz) |
Fan Motor FLA | 1.35A |
Motor Compressor (RLA/LRA) | 6A5A/37A |
WARNING
This product can expose you to chemicals including Styrene and its
compounds, which are known to the State of California to cause cancer and
birth defects or other reproductive harm. For more information, please visit:
www.P65Warning.ca.gov.
Special Notes
- When using the machine, please do not put it on a soft or uneven ground to prevent vibration and movement.
- Do not insert any thin rods or hard items into the machine to prevent malfunctions and dangers.
- When using the machine, please keep it away from any heating furnaces, electric kettles and other heating sources.
- When using the machine, please close doors and windows for the optimal temperature adjust effect.
- Please do not put any objects around the machine. The product function will be affected.
- Please unplug the machine from the power source if you do not use it for a long time.
- When cleaning the product, please use wet cloth to wipe gently. Do not spray water on it directly
- Please do not put any objects on the product.
- Please clean the filter every two weeks. Do not use hot water above 104°F, alcohol, gasoline or toluene.
- When using the hose to drain continuously, please place the hose horizontally and make sure it is even and not winded.
- After cleaning the filter, please do not dry it under direct sunlight to prevent it from deforming.
- Before moving or carrying the machine around, please empty the water tank first.
Warranty & Contactus
Warranty
Waykar offers a 12-month warranty to all of our products together with the
original proof of purchase when a defect occured, including those newly
purchased and unused, from Waykar or through an authorized reseller, wholly or
substantially, or as aresult of faulty manufacturing parts, or workmanship
during the Warranty Period.
The warranty does not apply if damage 1s caused by other factors, including
but without limitation of:
(a) Normal wear and tear;
(b) Abuse, mishandling, accident or failure to follow operating instructions;
(c) Exposure to liquid or infiltration of foreign particles;
(d) Servicing or modification of the product other than by Waykar.
There are our general terms for the warranty service, but we always encourage
our customers to contact us if any issues, regardless of warranty terms.
If you are experiencing an issue with Waykar product, you can reach out to us
at support@waykar.com, we will dedicate our
efforts to resolve it for you.
Extend Your Warranty by 1 Year
Register your product at www.waykar.com to extend
your 1-year warranty by an additional year.
“Please fill out all required fields and include your Order ID, Date of
Purchased ifapplicable.
Customer Support
If you have any questions or concerns about our product, please feel free to
contact our expert support team. Waykar customer service 1s ready to help.
Waykar Office
210 Henson Road Bldg A, Blacksburg, SC 29702 USA
Email: support@waykar.com
Live Chat: www.waykar.com
Support Hours
24 Hours available
*Please have your Order Number ready before contacting customer support.
For FAQs and more information please visit:
www.waykar.com
@ Waykar
@ Waykar @ Waykar @ Waykarhttps://www.waykar.com/
(Scan the QR Code for Live Chat)
We are expecting to see our products fulfill your life and hear your voice.
Your satisfaction means a lot to us.
Please tag us if you share a snap on your social media.
www.waykar.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>