HEALTHCARE LIGHTING POPS HPS9 Wall Sconce Instruction Manual
- June 13, 2024
- HEALTHCARE LIGHTING
Table of Contents
HEALTHCARE LIGHTING POPS HPS9 Wall Sconce
Product Information
- Product Name: Healthcare Lighting HPS9
- Revision: B
- Model Number: I-HPS9
- Revision Date: 10/11/2021
- Manufacturer: HealthCare Lighting
- Address: One Lithonia Way, Conyers, GA 30012
- Phone: 800-315-4963
- Website: www.acuitybrands.com
Product Usage Instructions
- Before installation or servicing, disconnect or turn off power to the luminaire to avoid the risk of electric shock.
- Verify the supply voltage by comparing it with the information provided on the luminaire label.
- Follow the National Electrical Code (NEC) and any applicable local code requirements for all electrical and grounded connections.
- All wiring connections should be capped with UL-approved recognized wire connectors.
- Wear gloves and safety glasses when handling the luminaire, installing, servicing, or performing maintenance.
- Avoid direct eye exposure to the light source when it is on.
- Allow the lamp/fixture to cool before handling and do not touch the enclosure or light source.
- Do not exceed the maximum wattage marked on the luminaire label.
- Follow all manufacturer’s warnings, recommendations, and restrictions for driver type, burning position, mounting locations/methods, replacement, and recycling.
- Keep combustible and other materials that can burn away from the lamp/lens.
- Do not operate the luminaire in close proximity to persons, combustible materials, or substances affected by heat or drying.
- Never connect components under load and avoid mounting or supporting the fixtures in a way that can damage wire insulation.
- Ensure compatibility of controls for dimming, auto-sensing, or remote control with the luminaire before installation.
- LED fixtures must be powered directly off a switched circuit.
- Ensure proper ventilation by not restricting the fixture’s airflow.
- Avoid covering LED fixtures with insulation, foam, or other materials that prevent convection or conduction cooling.
- Do not exceed the fixture’s maximum ambient temperature.
- Use the fixture only in its intended location.
- LED products are polarity-sensitive, so ensure proper polarity before installation.
- Electrostatic Discharge (ESD) can damage LED fixtures, so wear personal grounding equipment during installation or servicing.
- Avoid touching individual electrical components to prevent ESD, shorten lamp life, or alter performance.
- In case of service requirement, contact an ABL representative immediately and stop using the unit.
- Always read the fixture’s complete installation instructions prior to installation for any additional fixture-specific guidelines.
LED IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance on this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by a person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. The frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to the user. The refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water, and wiped dry. Should the optical assembly become dirty on the inside, wipe the refractor/lens and clean in the above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise that are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC SHOCK
- Disconnect or turn off power before installation or servicing.
- Verify that the supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL-approved recognized wire connectors.
WARNING
RISK OF BURN
- Allow lamp/fixture to cool before handling. Do not touch the enclosure or light source.
- Do not exceed the maximum wattage marked on the luminaire label.
- Follow all manufacturer’s warnings, recommendations, and restrictions for driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION
RISK OF INJURY
- Wear gloves and safety glasses at all times when removing luminaire from cartons, installing, servicing, or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
CAUTION
RISK OF FIRE
- Keep combustible and other materials that can burn, away from lamp/lens.
- Do not operate in close proximity to persons, combustible materials, or substances affected by heat or drying.
CAUTION: RISK OF PRODUCT DAMAGE
- Never connect components under load.
- Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
- Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire must be checked for compatibility with the luminaire prior to installation. LED fixtures must be powered directly off a switched circuit.
- Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around the fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
- Unless individual product specifications deem otherwise: Do not exceed fixtures’ maximum ambient temperature.
- Only use the fixture in its intended location.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- Some components inside the fixture may not be serviceable. In the unlikely event, that your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
- Always read the fixture’s complete installation instructions prior to installation for any additional fixture-specific warnings.
- Always ensure that the electrical distribution system is up to NEC (and any applicable local code) requirements.
- Verify that the power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void the warranty.
Choose either Part 15 OR Part 18 and move to Page 3 Installation Instructions under Delivery. Lithonia Outdoor will always use Part 15. All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference
- This device must accept any interference received, including interference that may cause undesired operation
This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other electronic devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communications equipment operating between 0.45 and 30MHz.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.
Our Brands
Indoor/Outdoor
- Lithonia Lighting
- Carandini
- Holophane
- RELOC
- Light Concepts
- Indoor Lighting
- Aculux
- Gotham
- Indy
- Juno
- Mark Architectural Lighting Peerless
- Renaissance Lighting
- Winona Lighting
Outdoor Lighting
- American Electric Lighting
- Antique Street Lamps
- Hydrel
- Tersen
Controls
- DARK TO LIGHT
- LC&D
- ROAM
- Sensor Switch
- Synergy
Daylighting
- SunOptics
The HPS9 is designed to mount to a 2-1/8” deep switch box, flush mounted to the wall surface.
Do not install this luminaire outdoors unless equipped with the ‘WL’ Wet Location option!
Installation Steps
-
Refer to the wiring diagrams on the next page to determine the appropriate connections for the project.
-
Connect supply wires to driver input wires (A) per wiring diagram.
-
Attach mounting plate (B) to the switch box so that driver (A) is located within the box.
-
Connect polarized plug (D) from luminaire to socket on driver (A).
-
Align threaded studs (E) with sockets (C) on the mounting plate.
-
Feed wiring through the hole in the mounting plate while firmly pressing the luminaire so that threaded studs snap in sockets.
Wet Label: Ensure the Gasket (F) is pressed firmly against the wall. Use silicone sealant between the luminaire and the wall to make the switch box watertight. -
Thread acrylic diffuser (I) onto fitter (H) being careful to avoid touching the LED module. Do not over-tighten.
Wet Label: Ensure the O-Ring Gasket is seated in the fitter before threading on the diffuser. Do not over-tighten.
Maintenance & Cleaning
No regular maintenance is required. The LED module & driver are non- serviceable components with a 50,000 hours operating life to 70% initial output. At 100,000 hours light output will be approximately 50% of initial. Clean the fixture with a soft cloth moistened with mild soap and water.
Wiring
POWER SUPPLY/DIMMING
this model is available with Dimming drivers in both 120V and 277V input
versions. Dimming drivers require a 0-10V fluorescent-type dimming control.
For non-dimming installations, cap the purple and pink wires.
NON-DIMMING INSTALLATIONS
- Connect the WHITE wire to power NEUTRAL.
- Connect the BLACK wire to power HOT
- Connect the GREEN wire to power GROUND.
- Read all instructions before installation.
- Do not make live connections!
DIMMING INSTALLATIONS
- The integral dimming driver is designed to the 0-10V IC dimming specification 60929 and is compatible with common 0-10V dimmers and dimming systems. Do NOT connect line voltage to dimming input wires.
- Connect the WHITE wire to power NEUTRAL.
- Connect the BLACK wire to power HOT.
- Connect VIOLET wire to POSITIVE INPUT of Dimming Control.
- Connect PINK wire to NEGATIVE INPUT of Dimming Control.
HealthCare Lighting One Lithonia Way, Conyers, GA 30012 Phone: 800-315-4963 www.acuitybrands.com.
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA