HEALTHCARE LIGHTING HNLS13 Pathfinder Night or Step Light Instruction Manual
- June 13, 2024
- HEALTHCARE LIGHTING
Table of Contents
HEALTHCARE LIGHTING HNLS13 Pathfinder Night or Step Light
Product Information
Important Safety Instructions
- Disconnect or turn off power before installation or servicing.
- Verify that supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL approved recognized wire connectors.
- Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
- Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
- Do not exceed maximum wattage marked on luminaire label. Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
- Keep combustible and other materials that can burn, away from lamp/lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
- Never connect components under load. Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
- Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire must be checked for compatibility with the luminaire prior to installation.
- LED fixtures must be powered directly off a switched circuit.
- Do not restrict fixture ventilation. Allow for some volume of airspace around fixture.
- Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
- Do not exceed fixture’s maximum ambient temperature.
- Only use fixture in its intended location.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
Contact Information
- HealthCare Lighting
- One Lithonia Way, Conyers, GA 30012
- Phone: 800-315-4963
- Website:www.acuitybrands.com
LED IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING RISK OF ELECTRIC SHOCK
- Disconnect or turn off power before installation or servicing.
- Verify that supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL approved recognized wire connectors.
CAUTION RISK OF INJURY
- Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
WARNING RISK OF BURN
- Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
- Do not exceed maximum wattage marked on luminaire label.
- Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION RISK OF FIRE
- Keep combustible and other materials that can burn, away from lamp/lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
CAUTION: RISK OF PRODUCT DAMAGE
- Never connect components under load.
- Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
- Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire must be checked for compatibility with the luminaire prior to installation. LED fixtures must be powered directly off a switched circuit.
- Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
- Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
- Only use fixture in its intended location.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
- Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
- Always ensure that the electrical distribution system is up to NEC (and any applicable local code) requirements.
- Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void warranty.
FCC
Choose either Part 15 OR Part 18 and move to Page 3 Installation Instructions under Delivery. Lithonia Outdoor will always use Part 15. All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference
- This device must accept any interference received, including interference that may cause undesired operation
This device complies with Part 18 of the FCC Rules but may cause interference
with cordless and cell phones, radios, televisions, and other electronic
devices. To correct the problem, move the device away from the luminaire or
plug into a different outlet. This product may cause interference to radio
equipment and should not be installed near maritime safety communications
equipment or other critical navigation or communications equipment operating
between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties. For
a complete listing of product Terms and Conditions, please visit
www.acuitybrands.com.
Our Brands Indoor/Outdoor|
Indoor Lighting| Outdoor Lighting| Controls| Daylighting
---|---|---|---|---
Lithonia Lighting| Aculux| American Electric Lighting| DARK TO LIGHT|
SunOptics
Carandini| Gotham| Antique Street Lamps| LC&D|
Holophane| Indy| Hydrel| ROAM|
RELOC| Juno| Tersen| Sensor Switch|
Light Concepts| Mark Architectural Lighting| | Synergy|
| Peerless| | |
| Renaissance Lighting| | |
| Winona Lighting| | |
OVERVIEW
- The HNLS13 3” is designed to mount to a standard junction box mounted flush to the wall surface. The Steel City 72171 is recommended.
- The HNLS13 6” is designed to mount to a standard junction box mounted flush to the wall surface. The Steel City 4G4D is recommended.
- The HNLS13 9” (shown below) is designed to mount to a standard junction box mounted flush to the wall surface. The Steel City H4BD is recommended.
- The HNLS13 12” is designed to mount to a standard junction box mounted flush to the wall surface. The Steel City H6BD is recommended.
Installation Steps:
- Refer to the wiring diagrams on the other side of this sheet to determine appropriate connections for the project.
- Attach mounting plate (B) to junction box with screws (by others).
- Connect supply wires to driver input wires (A) per wiring diagram.
- Remove and discard nuts holding screws (D) to LED unit and faceplate (C). Do not separate LED unit from faceplate.
- Apply silicone sealant to gasket on back of faceplate.
- Set LED unit (B) in box and align holes in faceplate to holes in box. Attach LED unit and faceplate to mounting plate with screws (D).
- Thread screws (D) through faceplate and LED unit securing fixture to junction box.
Maintenance & Cleaning
No regular maintenance is required. The LED module & driver are non- serviceable components with a 50,000 hours operating life to 70% initial output. At 100,000 hours light output will be approximately 50% of initial. Clean the fixture with a soft cloth moistened with mild soap and water.
Wiring
POWER SUPPLY / DIMMING
- This model is available with Dimming drivers in both 120V and 277V input versions.
- Dimming drivers require a 0-10V fluorescent-type dimming control.
- For non-dimming installations, cap the purple and pink wires.
- Read all instructions before installation. Do not make live connections!
NON-DIMMING INSTALLATIONS
- Connect STEP WHITE wire to power NEUTRAL.
- Connect STEP BLACK wire to power HOT.
- Connect STEP GREEN wire to power GROUND.
DIMMING INSTALLATIONS
- The integral dimming driver is designed to the 0-10V IC dimming specification 60929 and is compatible with common 0-10V dimmers and dimming systems.
- Do NOT connect line voltage to dimming input wires.
- Connect STEP WHITE wire to power NEUTRAL.
- Connect STEP BLACK wire to power HOT.
- Connect STEP VIOLET wire to POSITIVE INPUT of Dimming Control.
- Connect STEP PINK wire to NEGATIVE INPUT of Dimming Control.
- HealthCare Lighting One Lithonia Way, Conyers, GA 30012 Phone: 800-315-4963 www.acuitybrands.com
Documents / Resources
|
HEALTHCARE LIGHTING HNLS13 Pathfinder Night or Step
Light
[pdf] Instruction Manual
HNLS13 Pathfinder Night or Step Light, HNLS13, Pathfinder Night or Step Light,
Night or Step Light, Step Light
---|---
|
HEALTHCARE LIGHTING HNLS13 Pathfinder Night or Step
Light
[pdf] Instruction Manual
HNLS13 Pathfinder Night or Step Light, HNLS13, Pathfinder Night or Step Light,
Night or Step Light, Step Light, Light
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>