SEALEY ARD01.V2 On-Gun Digital Pressure Regulator Gauge Instructions
- June 4, 2024
- SEALEY
Table of Contents
ON-GUN DIGITAL PRESSURE REGULATOR/ GAUGE
MODEL NO: ARD01.V2
ARD01.V2 On-Gun Digital Pressure Regulator Gauge
Thank you for purchasing a Sealey product. Manufactured to a high standard,
this product will, if used according to these instructions, and properly
maintained, give you years of trouble-free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE
OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE
FOR FUTURE USE.
Refer to instructions
SAFETY
WARNING! Ensure Health & Safety, local authority, and general workshop
practice regulations are adhered to when using this equipment.
WARNING! Disconnect the equipment from the air supply before changing
accessories, servicing or performing any maintenance.
Keep the equipment clean and maintain it in good condition (use an authorized
service agent).
Replace or repair damaged parts. Use genuine parts only. Unauthorized parts
may be dangerous and will invalidate the warranty.
WARNING! Ensure that the correct air pressure is maintained and not
exceeded.
Keep air hoses away from heat, oil, and sharp edges. Check hoses for wear
before each use and ensure that all connections are secure.
DO NOT direct air from the air hose at yourself, others, or animals.
DO NOT operate air tools when tired or under the influence of drugs,
alcohol or intoxicating medication.
Drain the compressor air tank and the filter bowl daily. Water in the airline
will damage your equipment.
When work is complete ensure that the air supply is turned off.
INTRODUCTION
On/Off button with adjustable auto-off function for extended battery life. Small and compact with a composite body. Pressure can be displayed in psi, bar, kg/cm² or a.
SPECIFICATION
Model no.: ……………………………………………………. ARD01.V2
Maximum Pressure: ……..160psi/11bar/11.25kg/cm2 /1100kPa
Maximum Flow: …………………………………….. 20cfm @ 100psi
OPERATION
4.1. SETTINGS
NOTE: Unless set otherwise, the gauge automatically shuts off after 60
seconds. To increase this time, see section 4.3.
4.1.1. Press the on/off button once to switch the gauge on or off.
4.1.2. Additionally, the on/off button may be used to alter the three function
settings.
4.2. CHANGING THE FUNCTION SETTING
4.2.1. Ensure that the gauge is not under pressure.
4.2.2. With the gauge switched on, hold the On button for about 3 seconds
until the display shows ‘—’ then release the button.
4.2.3. The display will cycle between 0,1, 2, and E.
[-0-] mode resets the gauge to zero.
[-1-] mode resets the automatic shut-off mode.
[-2-] mode resets the pressure units.
[-E-] resetting is completed when “END” shows in the display.
4.2.4. Press the button to enter one of the modes.
4.3. RESET TO ZERO
4.3.1. Ensure that the gauge is not under pressure.
4.3.2. Select mode 0 and the display will show 00-.
4.3.5. Press the button again and the display will show 000.
4.3.6. Press the button again within 3 seconds and the gauge will reset to
zero.
4.3.7. ‘End’ will display for 2 seconds and the unit will switch off
automatically.
4.4. AUTOMATIC SHUT-OFF MODE
4.4.1. The default automatic shut-off time is 60 seconds.
4.4.2. To change the automatic shut-off time, select mode 1 as per
instructions as at 4.2.2 and 4.2.3.
4.4.3. The display will cycle between 30, 60 120, and 180 seconds.
4.4.4. Press the button to select the required automatic shut-off time.
4.4.5. The selected time will flash 3 times and ‘end’ will display before the
unit switches off.
4.5. PRESSURE UNIT SELECTION MODE
4.5.1. The default pressure unit setting is psi.
4.5.2. To change the pressure units, select mode 2 as at 4.2.2. and 4.2.3.
4.5.3. After selecting mode 2 a dash will appear at the bottom of the display,
corresponding to the units displayed (psi, bar, kg/cm2 or kPa).
4.5.4. When the screen corresponds to the required setting, press the button
to select.
4.5.5. The selected unit will flash 3 times. After showing ‘End’ , the unit
will switch off.
5.1. Mount the regulator/gauge in a convenient location in the air inlet
circuit, ensuring that all connections are tight.
5.2. To adjust the pressure, turn the adjusting knob clockwise to reduce and
anticlockwise to increase.
BATTERY REPLACEMENT
NOTE: The replacement battery is a CR2032 3V button cell.
6.1. Lay the unit face down on a flat, dry surface and carefully remove the 4
crosshead screws holding the unit together.
6.2. Carefully lift the rear off the unit, taking care to NOT disturb the
screen arrangement in the front section.
6.3. Slide the battery out from under the spring restraint and replace it with
a clean fully charged battery.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories, and packaging should be sorted, taken to a recycling center, and
disposed of in a manner that is compatible with the environment. When the
product becomes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers and dispose of the product and
fluids according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the
EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the
product is no longer required, it must be disposed of in an environmentally
protective way. Contact your local solid waste authority for recycling
information.
BATTERY REMOVAL
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd
are required to inform potential purchasers of products containing batteries
(as defined within these regulations), that they are registered with Valpak’s
registered compliance scheme. Jack Sealey Ltd Batteries Producer Registration
Number (BPRN) is BPRN00705.
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications, and component parts without
prior notice. Please note that other versions of this product are available.
If you require documentation for alternative versions, please email or call
our technical team on technical@sealey.co.uk
or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: The guarantee is 12 months from the purchase date, proof of which is
required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk.
IP32 7AR
01284 757500
01284 703534
**sales@sealey.co.uk
****www.sealey.co.uk
© Jack Sealey Limited
Original Language Version
ARD01.V2 Issue 2 07/07/21**
Documents / Resources
|
SEALEY ARD01.V2 On-Gun Digital Pressure Regulator
Gauge
[pdf] Instructions
ARD01.V2, On-Gun Digital Pressure Regulator Gauge, ARD01.V2 On-Gun Digital
Pressure Regulator Gauge, Digital Pressure Regulator Gauge, Pressure Regulator
Gauge, Regulator Gauge, Gauge
---|---
|
SEALEY ARD01.V2 On Gun Digital Pressure Regulator
Gauge
[pdf] Instruction Manual
ARD01.V2 On Gun Digital Pressure Regulator Gauge, ARD01.V2, On Gun Digital
Pressure Regulator Gauge, Digital Pressure Regulator Gauge, Pressure Regulator
Gauge, Regulator Gauge, Gauge
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>