HARVIA WHP500 Extension For Chimney User Manual

June 13, 2024
HARVIA

HARVIA logo WHP500, WHP1000

WHP500 Extension For Chimney

May only be installed with steel chimney WHP1500! HARVIA WHP500 Extension
For Chimney - Assembly

Harvia Finland Oy, PL 12, 40951 Muurame, Finland
16
0809-CPD-0548
EN 1856-1
Steel Chimney
Multi-wall
T600 – N1 – D – VmL20070 – G100
Compressive strength
Maximum load: 5,0 m of chimney elements
Flow resistance
NPD
Thermal resistance
NPD
Sootfire resistance: Yes
Flexural strength
Tensile strength: 5,0 m
Non-vertical installations: not allowed.
Wind load:
Free standing height: 2,0 m above last support.
Maximum spacing of lateral supports:
3.0 m
Freeze thaw resistance: Yes
NPD = no performance determined

Declaration of Preformance

DoPWHP

Product type| Harvia Steel Chimney (WHP1S00, WHP1000, WHPS00, WHP1500M, WHP1000M, WHPSOOM)| Harvia
PL 12 (Teollisuustie 1—7)
40951 Muurame
Finland
---|---|---
Intended use| Harvia Steel Chimney is a system chimney of modular construction. It is intended for removal offlue gas in solid fuel run heating appliances. Harvia Steel Chimney can have a total length of 5.0 metres at maximum.
The product conforms to the following standards| Harvia Steel Chimney WHP fulfils the requirements set for metal chimneys by the standard EN 1856-1. Products are tested in accordance to the methods described in the standard EN 1859.
Notified body (identification number)| VTT, PL 1000, 02044 VTT, Finland (0809)
Declared performance

Essential characteristic| Performance| Harmonised technical specification
Compressive strength – maximum load| 5,0 m of chimney elements| EN 1856.1
Flow resistance| NPD
Thermal resistance| NPD
Sootfire resistance| Yes
Flexural strength
– tensile strength
– non-vertical installations| 5,0 m
not allowed
Wind load
– free standing height| 2,0 m above last support
Maximum spacing of lateral supports| 3,0 m
Freeze thaw resistance| Yes
Temperature class
(max. nominal chimney gas temperature of fireplace 600 t)| T600
Pressure class (N1: low pressure chimney)| Ni
Condensate (condensation) resistance rating
(D: dry operating conditions, chimney gas temperature is above water condensation level)| D
Corrosion resistance
(Vm-L20: based on the material rating A151304)
(070: thickness of smoke pipe walling)| VmL20070
Sootfire resistance (G: sootfire resistant) and distance to combustible material (in millimetres)| G100

NPD = no performance determined/NPD = Keine Leistung bestimmt

Muurame, Finland, 01.04.2016
Teemu Harvia
Technical Director/Technische Leiter