Introduction

Please read all the user manual before operating the machine, and place the manual where the user can refer to it at all time. The manual includes how to install and operate the machine under safe conditions and explain all the labels printed on the machine. If you encounter any problem, contact your local Antari dealer for assistant immediately.

Safety Information

DANGER If the danger is not avoided, it will cause death or serious injury
WARNING If the warning is not heeded, it can cause death or serious injury.
CAUTION If the precaution is not taken, it may cause minor or moderate

injury.

DANGER

  • Must connect the machine to the correct rated voltage or it might lead to an electrical shock or a burn and may cause serious consequences.
  • Must connect the machine to a protected circuit and ensure it is properly grounded to avoid the risk of electrocution. For grounding instruction, please refer to Appendix I on page 15.
  • Do not operate the machine with a bundled power cord, it could lead to a fire hazard.
  • When operating the machine, do not point at people, animals, or fire.

WARNING

  • Please operate the machine on a flat, level hard and well ventilated surface area, reserve at least 50cm space around the machine and make sure there is no flammable gas or material nearby.
  • Do not disassemble, repair or modify the machine, it may cause damages, malfunction, risk of electrical shock or result in fire.
  • The machine can only be operated by adults or professionals, is not intended for use by person with reduced physical sensory, mental capabilities, or lack of experience and knowledge including children.
  • Do not leave the machine running unattended, make sure all powers are off when leaving.
  • Children should be supervised to ensure that they do not play with the machine.
  • Do not use the machine upside down or tilt it, it might cause damages or malfunction.
  • Please store the fluid inside in a well ventilated area without direct sunlight and keep out of reach of children. In case of eye contact or accidentally swallow the fluid, please seek medical attention immediately.

** CAUTION**

  • Keep the machine dry at all time. The machine is not waterproof, do not expose the machine to water, rain or moisture environment.
  • Please make sure the power outlet is not damaged or loose before plug in the power cord.
  • If the power cord is damaged, it must be replaced by Antari or its local dealers, otherwise the warranty will be void.
  • Before transporting the machine, please make sure the fluid is drained and tank is empty. (Recommend using original package)
  • The machine is for indoor use only.
  • Do not operate the machine in any area with unstable voltage.
  • If you experience strange sound or malfunction, turn off the power and unplug the power cord immediately and contact your local Antari dealer for assistant.
  • Do not contact any moving part.
  • Only use accessories recommended or sold by Antari.
  • Please make sure the power is off when not using the machine and unplug the power cord if not intend to use for a long period of time.
  • To disconnect, turn all controls to the off position, then remove plug from outlet.
  • Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
  • Unplug from outlet before servicing or cleaning.
  • Do not operate the machine with a damaged cord or plug, or after the machine malfunctions or is dropped or damaged in any manner. Return machine to the nearest authorized service facility for examination, repair, or electrical or mechanical adjustment.
  • To ensure the lifespan of the machine, please only use the fluid manufactured by Antari, do not use other fluid or additive, otherwise it may cause malfunction.

Before operating the machine, please read all warning labels on the machine, description as below;
Top Cover Printing
USE DEALER RECOMMENEDED HAZE LIQUID ONLY!
DO NOT OPEN CASE RISK OF ELECTRIC SHOCK
WARNING!
PLEASE USE RECOMMENED, NON-FLAMMABLE FLUID ONLY. MAKE SURE THT THE LIQUID LEVEL DOES NOT EXCEED THE MARK AS MACHINE PERFORMANCE MAY SUFFER
Rear Cover Printing
WARNING!
DISCONNECT POWER BEFORE CHANGING FUSE.
USE ONLY WITH ADULT SUPERVISION.
DO NOT OPERATE WITHOUT LIQUID.
FOR INDOOR USE ONLY. KEEP DRY.
NO USER SERVICEABLE PARTS INSIDE.
MAX. FLUID LEVEL
MAKE SURE THAT THE LIQUID LEVEL DOES NOT EXCEED THIS MARK.

Package Contents & Inspection

Immediately upon receiving the machine, carefully unpack the carton, check the content to ensure it is the correct model and all parts are included. If any part appears to be damaged or missing during transportation, please contact your local dealer and return in original package for inspection.
3.1 Package Contents
1 x HZ-350 Haze Machine
1 x IEC Connector (Power)
1 x W-1 Wireless Transmitter
1 x User Manual or scan QR Code on the Machine
3.2 Optional Accessories

Item Code Description
HC-1 Timer Cable Remote

Machine Details

Antari HZ-350 Haze Machine - Machine Detail

01. Fog Nozzle 06. Wireless Receiver
02. Handle 07. XLR 5-Pin DMX
03. Tank Cap 08. Remote Input
04. Fan 09. Power Switch
05. LCD Display 10. IEC Connector (Power)

Technical Label Information

Please read the technical label information on the back of the machine before operating it.

Antari HZ-350 Haze Machine - QR Cord

1. Model Name| 5. Breaker/Fuse
2. Input Voltage| 6. QR CODE for User Manual
3. Frequency| 7. Serial No.
4. Rated Power| 1

Haze Fluid

CAUTION
Always turn off the power before filling the fluid tank. Do not add flammable liquid to the fluid tank. If fluid gets inside the machine, please contact your local Antari dealer for assistant.

  • Only the haze fluid manufactured by Antari can be used, do not mix or dilute the haze fluid. Due to improper storage or using other fluid might cause malfunction.
  • The machine is tested and calibrated with the specific haze fluid to get the best performance.
  • Please empty the fluid in the tank before switching to another fluid to avoid mixing.
  • The warranty on your haze machine will be void if you use haze fluid not manufactured by Antari.

Setting and Manual Operation

WARNING
Machine falling off might cause serious injury, please make sure it is secure and firm on the overhead.
Step 1. Place the machine on a flat, level hard and well ventilated surface area and reserve at least 50cm open  space around the machine, and make sure there is no flammable gas or material nearby;
Step 2. Fill with Antari approved haze fluid;
Step 3. Connect the machine to the power outlet. Please read the technical label on the back of the machine and make sure the power outlet is the correspond to the rated voltage for the machine;
Step 4. Turn on the machine, once the machine is ready for operation, the LCD display will show “Ready To Haze”;
Step 5. To start hazing, press [TIMER] once and to stop hazing, press [STOP], this will run based on “interval” & “duration” setting in the main menu;
Step 6. To start hazing, you can also press [ON] button once and to stop hazing, press [STOP];
Step 7. To turn off the machine, please make sure the machine is not operating then turn of the power. If you will not use the machine a long period of time, please remove the power cord.

Control Settings

HZ-350 Haze Machine can be operated in the following modes. The machine can only accept 1 type of signal at a time. When using different control modes at the same time, the machine will work according to built-in control priority:

  • Manual
  • Timer
  • DMX512
  • Wireless
  • Cable Remote

8.1 Control Panel Description

Antari HZ-350 Haze Machine - Control Panel
HZ-350 Haze Machine can be operated with the onboard digital control interface.

Button Operating Method Action
Menu Press To enter setting menu
Up Press Increase value
Down Press Decrease value
TIMER Press 1. Press to start hazing according to the set time

2. Press “stop” to stop hazing
ON| Press| 1. Press to start hazing
2. Press “stop” to stop hazing
Stop| Press| 1. Press once to choose function in set menu
2. Leave setting menu
3. Stop hazing

8.2 Menu Options Description

Options Description
Interval Set Interval between 5-200 sec
Duration Set Duration between5-200 sec
DMX512 Add.001 001-512
Wireless On On (“W” Showed) / Off (“W” not show) “Ready to Haze Sceen”
Quick Start On / Off

DMX Connection

9.1 DMX Connector Pin Assignment
The machine has a XLR 5-Pin for DMX connection. The diagram below indicates pin assignment information.

| There is a protection cap on DMX IN, please remove it with your finger before operation.
Antari HZ-350 Haze Machine - DMX Connector 1
---|---
Pin| Function**
1| Ground
2| Data-
3| Data+
4| N/A
5| N/A

9.2 DMX Channel Function

DMX Value Function
0~10 Off
11~255 On

W-1 Wireless Transmitter (Standard)

W-1 Wireless Transmitter is a standard accessory for HZ-350 Hazer Machine and it’s ready to use.
10.1 W-1 Wireless Transmitter

  • Battery:27A 12V
  • Effective Range:The effective range is approximately 50m, depends on actual condition, it may vary.
  • W-1 wireless transmitter has 2 buttons, each function as follow:
Button Function
[A] Start
[B] Stop

10.2 Pairing
Each receiver can pair up to 5 transmitters, please follow the steps below to pair;
Step 1. Turn on the power, “Wireless Setup” will show on the display for 15 seconds. Within this time period, press button A on the W-1 transmitter to pair with the machine. When screen shows “Wireless Setup OK”, means it’s paired;
Step 2. Please repeat Step 1 to pair multiple transmitters;
*If exceed 15 seconds, turn the power off and on again.

HC-1 Cable Remote (Optional)

Antari HZ-350 Haze Machine - Cable RemoteHC-1 Timer Cable Remote is an optional accessory for HZ-350 Haze Machine, please see instruction below;

Button/Knob Function
DURATION [KNOB] Adjust Duration
INTERVAL [KNOB] Adjust Interval
POWER [RED BUTTON] Power On / Off
HAZE [GREEN BUTTON] Fogging On / Off
TIMER ON/OFF [YELLOW BUTTON] Timer Mode On / Off

** If you encounter any problem, please contact your local Antari dealer for assistant.

Technical Specifications

HZ-350

Input Voltage| US Model : AC 100-120V, 50/60Hz 3.5A
EU Model : AC 220-240V, 50/60Hz 2.0A
Rated Power| 390W
Fluid Consumption| 0.8 ml/min (100% output)
Operating Time| 52 hrs (100% output)
Fluid Tank Capacity| 2.5 Liters (0.66 gallon)
Compatible Fluid| Antari HZL Haze Fluid
Ambient Temp. Range| 0°C – 40°C (32°F – 104°F)
Control Methods| Manual、Timer、DMX512、Wireless (Standard)、Cable Remote (Optional)
Interface| XLR 5-Pin (DMX)、IEC (Power)
DMX Channels| 1 Channel
Included Accessories| W-1 Wireless Transmitter
Optional Accessories| HC-1 Timer Cable Remote
Dimension| L 492 W 273 H 315 mm (L 19.37 W 10.75 H 12.40 inch)
Weight| 14.2 kg (31.31 lbs.)

Warranty Disclaimer

We guarantee the merchandise manufactured by us to be free from defect in material and workmanship for a period of one year. Our obligation and liability under this warranty shall be restricted to repair or replacement at our factory or local authorized dealer. We assume no liability of the products that are improperly used or used for any purpose other than that for which they are specially designed. This warranty shall not apply to any merchandise which has been repaired, altered or assembled outside our factory in any way so as in our judgment to affect its performance, nor which has been subjected to misuse, negligence, or accident nor to any merchandise operated contrary to our printed instructions. We will not allow or be liable of any loss or any damages of any kind in connection with the use, sale, or repair of any merchandise purchased from us.

Machine Dimension

Antari HZ-350 Haze Machine - Dimension

Appendix I Grounding Instruction

This appliance must be grounded. In the event of malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
DANGER – Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipmentgrounding conductor. If repair or replacement of the cord or plug is necessary, do not connect the equipmentgrounding conductor to a live terminal. Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This appliance is for use on a nominal 120 V circuit, and has a grounding plug that looks like the plug illustrated in sketch A in Figure. A temporary adaptor, which looks like the adaptor illustrated in sketches B and C, may be used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet can be installed by a qualified electrician. The green colored rigid ear, lug, and the like, extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by the metal screw.

Antari HZ-350 Haze Machine - connectionAntari
Logo C08HZ3506

Documents / Resources

| Antari HZ-350 Haze Machine [pdf] User Manual
HZ-350, HZ-350 Haze Machine, Haze Machine, Machine
---|---
| Antari HZ-350 Haze Machine [pdf] User Manual
HZ-350 Haze Machine, HZ-350, Haze Machine, Machine

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals